Rebuild 19mm & 25mm Sensors

Similar documents
ph or ORP Transmitter

Chin Strap, Sealed Pull Pins and Swing Catch for Fiberglass Helmets. Contents

4.2 - PUMP MAINTENANCE MODELS: AC, AS, WC, WS

MOTOR & BULK HEAD. A Manual for Repair and Maintenance Technicians

35 mw HeNe Laser Ballast Resistor Insulation Upgrade Instructions

Installation Instructions 8115F 8115SF

3 Emergency Breakaway Coupling

Installation Instructions Road King Classic Saddlebag Bezels

Pressure Balance Shower Only Dual Control (Volume & Temperature) Ceramic Disc Cartridge Platinum Shower Trim Kit

GENUINE PARTS INSTALLATION INSTRUCTIONS

YALE FIGURE 500 & 500R CLOSURE OPERATION AND MAINTENANCE INSTRUCTIONS

7878 K940. Checkpoint Antenna. Kit Instructions. Issue B

H8508 Impact Wrench SERVICE MANUAL. Model (Serial Code FWN) Model (Serial Code FWP)

3.2.3 Rear Door Window and Quarter Window Carrier Assembly

Maintenance & Parts list for:

TYPE 3740/3740D WET/DRY RUNNING CARTRIDGE SPLIT SEAL

INSTALLATION INSTRUCTIONS for DALTON LED SERIES

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extension Sections. Reliable Connections

WARNING: Wear safety goggles at all times when the engine is running and cooling

MIL-STD B (SH) UPDATE

just below the screen. Data collection will begin, and a graph will show your data being plotted in real time.

Ribcage Installation. Part 2 - Assembly. Back-Bone V1.06

MODEL H " BYRD SHELIX CUTTERHEAD INSTRUCTIONS

Auto-Spreader Spreader HS10K Hydraulic Flange Spreader

OTECO INC. MODEL ,000 PSI 4-1/16 PORT DM GATE VALVE MAINTENANCE MANUAL

MUELLER. Improved, Centurion Series, Modern Improved, and 107. Fire Hydrants. Inserting Extention Sections. Reliable Connections

POWERNAIL CO. Seal Kit Replacement Guide. Seal Kit for all Pneumatic Nailers: # A (Includes 1 of each seal for a pneumatic rebuild)

Repair Instructions. Replacing a La Z Time Mechanism Side Subassembly. Remove the Back(s): Remove the Mechanism Assembly: CAUTION.

INSTALLATION INSTRUCTIONS

TYPE 3740XL EXTRA LARGE WET RUNNING CARTRIDGE SPLIT SEAL

Snap Tabs, Chin Strap, Swing Catch, Sealed Pull Pins Stainless Steel. Contents

General Safety and Maintenance Manual

Repair Instructions. Durametallic PSS III. Experience In Motion. Split Seal

Important Notices. Manway Lockout Point

Midwest RDH Handpiece Repair Procedure

Water Line and Water Line Assembly Gasket

OPERATION AND MAINTENANCE FOR MODEL MRV050A REVERSIBLE

FIXTURE INSTALLATION GUIDE Model T21T (Low Voltage Pendant Set 120V)

4.4 PUMP MAINTENANCE MODELS: DB, DC, DF, DG, DJ, DL

SECTION side windows round corners

MaxiMist SprayMate Pro HVLP TANNING SYSTEM

Dynamic Nanospray Probe (NSI-1) Installation Guide

COBRA SERIES CONVERTER

Side and rear window, assembly overview

Conductivity Transmitter

WARNING Indicates a hazardous situation which, if not avoided, could result in death or serious injury. WARNING. Ranger XP Door Kit

LPK1550 Hydraulic Crimping Tool 15-ton

SUPER PRO GUN & SUPER PRO GUN II

Hawko LED Flex & Accessories Installation Instructions

ARROW SAW PRECISE CUT 8000 RPM WITH DUST COLLECTING ATTACHMENT INSTRUCTION BOOK MODEL NO

1.0 Tool Components and Operation Instructions

Mechanical Frappe Press

TECHNICAL INSTRUCTIONS

MODEL T " SPIRAL CUTTERHEAD INSTALLATION INSTRUCTIONS

MODEL T27451/T " & 20" SPIRAL CUTTERHEAD INSTRUCTIONS

Volvo 240/260 New Face Overlay Installation Models By Dave Barton

#4500 BULLET SIZER & LUBRICATOR

DO35 MAINTENANCE INSTRUCTIONS

TOYOTA TACOMA LED BED LIGHTS Preparation

Keypad Lock Retrofit Kit for Follett REF Undercounter Refrigerator P/N

MaxiMist Pro Series Spray Gun

EmagiKit. Privacy Pod Plus. Quiet. Easy. Affordable. INSTRUCTIONS ASSEMBLY

A socket contact support (supplied separately) must be installed onto the locator assembly.

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Inventory (Figure 2)

General Safety and Maintenance Manual

Installation Instructions

Application Tooling Specification Sheet

Repair Manual MK40A-MK45A-MK50A MK55A-MK60A-MK65A. Ref Rev.C General Pump is a Member of The Interpump Group

Be sure any accessory used will fit with the soft upper doors before installing. Not all accessories will be compatible.

ALLORA SWING PANEL INSTALLATION INSTRUCTIONS

Bath Accessory Installation

SAM. Model: STV-C65 LCD Mobile Visualized Stand Instruction Manual. Weight Capacity: 1251bs / 56.7kg Suits LCD Flat Panel Display: 42"-55" Page 20

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

C-1116LMA - Automatic Stapler w/ Long Mag

Sea Doo Spark Engine Access Kit

OWNER S MANUAL. Safety. Please read this owner s manual before use and keep it at hand for reference. Warranty

H6400, H6400C1 & VSD6400 REVERSIBLE DRILLS

Measuring and Controlling Unit Multronic OC

Maintenance Information

INSTALLATION & OPERATING INSTRUCTIONS. REDCO LETTUCE KING I and LETTUCE KING IV

Cable Cutter Square. 25 Tape Measure. Chalk Line Level Loctite 242 Blue

Flat Sample Holder Part Number

3M Impact Protection Profile Installation System Instructions

ITEM NO. PART NO DESCRIPTION QTY.

ELECTRIC TOOL CORPORATION

Installation Manual Porter Road, Sarasota FL fax

INSTALLATION INSTRUCTIONS

SawStop. T-GlideTM. Fence System- Professional Series II OWNER S MANUAL

PRODUCT: LOKI INSTALLATION INSTRUCTIONS. Product is covered by U.S. patents. For more information visit

High Speed Air Turbine Handpiece

Signal Mirror Installation Instructions Honda Odyssey

Band-Master ATS Nano Pneumatic Banding Tool Operating Instructions

Quick Fit Installation Guide Retractable Screen - Double Door

OPTISENS PH 8390 Technical Datasheet

Fuel - Defuel Valve. Model Maintenance & Repair Manual. SM61499 Issued: February 1996 Applicable additional manuals: NONE

Application Tooling Specification Sheet

TNC SERIES General... 4 Interface... 5 Characteristics...6-7

IMPORTANT WARRANTY & INSTALLATION INSTRUCTIONS ATTACHED

OWNER S MANUAL CONTENTS. The only table saw fence with Automatic Positioning Control TM

Transcription:

Instruction Manual QUICK GUIDE Changing the Membrane Chapter 3 Polarizing Chapter 4 Replacement Parts Chapter 5 OxyProbe Rebuild 19mm & 25mm Sensors Doc No. L2553 12/2000 OxyProbe is a registered trademark of Broadley Technologies 19 Thomas, Irvine, California 92618 USA Call Toll-Free: 877.246.7900 (USA & Canada) Phone: 949.452.1112 Fax: 949.452.1115 E-Mail: sales@broadleytech.com

Table of Contents Chapter 1: Getting Started...1-1 Chapter 2: Replacing the Anode/Cathode Assembly...2-1 Chapter 3: Replacing the Membrane Cartridge...3-1 Chapter 4: Polarizing the Sensor...4-1 Chapter 5: Parts and Accessories...5-1 List of Figures 1 Exploded View of 19 mm D.O. Sensor...5-8 2 Exploded View of 25 x 70 mm D.O. Sensor...5-10 3 Exploded View of 25 x 150 mm D.O. Sensor...5-12 i

Chapter 1: Getting Started Procedures Checklist You ll need the following items in order to rebuild an OxyProbe dissolved oxygen D.O. sensor. See Chapter 5 for ordering information. Cathode Removal Tool New Anode/Cathode Assembly New O-rings Internal (4 and a conical gasket) External (1) Membrane Cartridge D.O. Electrolyte Solution These items are also necessary, but not provided by Broadley-James Corporation Desiccant Screwdriver (straight edge) Teflon Tape Cleaning Brush RTV Adhesive (Optional) Before getting into the procedures consider the problems to be encountered with each component. STAINLESS STEEL COMPONENTS: These parts require a good visual inspection for general condition and cleaning. A couple of brushes and some warm soapy water will generally take care of any problems. O-RINGS: O-rings separate the media from the sensor s internal components. O-rings should be inspected and changed as often as possible. stainless steel reinforced silicone layer. A microscopic hole or tear can lead to erroneous readings. CATHODE: The cathode is the platinum wire centered inside a precision ground glass surface where oxygen is reduced. Any coating, chips, or cracks on the glass surface will impair the sensor performance. The glass tip can be cleaned, but any physical damage may necessitate replacement. ANODE: This is the silver element that surrounds the glass cathode body. It will become discolored with use, but proper cleaning will restore it to new condition. However, improper cleaning may damage it. Harsh cleaning methods may alter the anode s geometry thereby changing the sensor output. TEMPERATURE COMPENSATOR: Temperature compensators (TC) measure the solution s temperature and change the transmitter s response accordingly. TC s progressively age after repeated sterilization cycles. Since the membrane s ability to diffuse gas is temperature dependent, a TC working improperly due to age abuse or poor calibration, can cause a significant measurement error. CABLES: The D.O. sensor s output is in nanoamps (na). A working sensor has an output of 30 to 90 na at 100% saturation. Any corroded connectors, nicked cables, or loose/contacts can lead to errors. Regular visual inspection is necessary. MEMBRANE: The membrane is perhaps the most critical component. It is made of gas permeable PTFE with a thicker 1-1

Chapter 2: Replacing the Anode/Cathode Assembly STEP 1 Remove the nosepiece and membrane cartridge. STEP 3 Remove the three screws and lift the sensor connector. STEP 2 Remove conical gasket and o-rings. 2-1

STEP 4 Using a razor blade, remove adhesive and disconnect the black anode/cathode connection Adhesive STEP 5 A Remove o-ring. C STEP 6 Empty desiccant from the sensor, noting the color and condition. Blue indicates possible moisture intrusion. B 2-2

STEP 7 Using the cathode removal tool (P/N AM-9213), unscrew the cathode retainer ring. STEP 8 Remove the anode/cathode assembly by using a turning/twisting motion while pulling it free from the body. 2-3

STEP 9 With the OxyProbe completely disassembled, clean all internal and external threads. It will take a few minutes, a couple of brushes, and hot soapy water. CATHODE RETAINER RING A B C RETAINER RING THREADS INTERNAL THREADS SOCKET SENSOR BODY D E F MIDDLE SLEEVE SEAL SLEEVE THREADS REAR SLEEVE SEAL G REAR SEAL FOR CONNECTOR FLANGE 2-4

STEP 10 Install the new anode/cathode assembly by pushing down and turning it clockwise. FLANGE O-RING WARNING: Inserting the anode/cathode assembly without turning it can scar the o-rings as they pass the internal threads. 2-5

STEP 11 Install the second o-ring. O-RING EPDM AS-011 STEP 12 Wrap the retainer ring with Teflon tape, and install by hand. 2-6

Tighten the retainer nut to a hard stop. The nut should be flush with the top of the sensor body, or slightly recessed from the top. CAUTION: Do not over tighten! Hand-tight and flush with the housing is adequate! STEP 13 Tighten the retainer nut into place using the cathode removal tool. CAUTION: Use care when placing the tool on the cathode. Do not tap or bump the glass with the tool! 2-7

STEP 14 Install silicone o-ring. STEP 15 Attach the mini-connector by matching wire colors. WHITE RED BROWN BLACK WHITE RED BROWN BLACK ENLARGED VIEW OF MINI-CONNECTOR STEP 16 Secure the mini connector with a small dollop of RTV adhesive (optional). NOTE: Allow to cure for 3 5 minutes before proceeding to the next step. SIDE VIEW OF MINI-CONNECTOR WITH ADHESIVE 2-8

STEP 17 Add desiccant to the sensor. Fill about 3/4 of sensor body. Allow space for the connector and wires. 2-9

STEP 18 Push the mini-connector into the sensor body while seating the connector flange onto the back of the o-ring. STEP 19 Install the connector screws. 2-10

STEP 20 Replace the o-rings on the rear and middle sleeve seals. Also age the conical gasket to seal the back of the cartridge. CONICAL GASKET SILICONE SIZE AS-014 Sensor is now rebuilt and ready for membrane cartridge installation. 2-11

Chapter 3: Replacing Membrane Cartridge STEP 21 CAUTION: WEAR SAFETY GLASSES DURING THIS PROCEDURE While holding the membrane cartridge upright (opening up) in one hand, carefully add the electrolyte from the bottle into the cartridge until it is approximately 75% full. Remove any large air bubbles by tapping on the side of the membrane cartridge. Try not to spill the electrolyte. Cartridge Opening Refill Spout Membrane Cartridge Assembly Membrane Surface Electrolyte 25 ml Bottle 3-1

STEP 22 Grip the filled membrane cartridge, by the thumb and forefinger slots in one hand, while holding the sensor in the other as shown. STEP 23 While compressing the membrane cartridge with the thumb and forefinger, slide the cartridge over the anode/ cathode assembly until the cartridge seats against the conical gasket. Release the pressure from the thumb and forefinger. Rinse the lower portion of the subassembly with DI water to remove any excess electrolyte and blot dry with a clean tissue. The sensor body subassembly with membrane cartridge in place is now ready for the installation of the stainless steel sensor sleeve. 3-2

STEP 24 Slide the stainless steel sensor sleeve over the membrane cartridge, being careful not to nick the o-rings. Be certain the threads of the sleeve and sensor body are free of any dirt or debris. Flush Fit Thread the stainless steel sensor sleeve onto the sensor body in the direction shown by the arrow. Be certain that the sleeve is flush with the sensor body so that no o-rings are visible. Do not overtighten. Hand tight is all that is necessary. The sensor is ready to be polarized. 3-3

Chapter 4: Polarizing the Sensor When the polarizer is attached to a dissolved oxygen sensor (as shown below) the internal battery circuit is completed. A polarization voltage of 675mV is applied between the anode and the cathode of the D.O. sensor. The sensor s current is initially very high as oxygen is depleted from the internal electrolyte solution, but then falls off exponentially and settles down to a steady state after a few hours. Since this polarization period is relatively long the sensor should be connected to a powered transmitter or polarizing unit when not in use. Owing to the very small current flowing through the sensor under these conditions, its life will not be shortened. If for any reason the sensor is disconnected (or the transmitter power switched off) for an extended period, the sensor must be repolarized before it is ready for further use. During the polarization period, the sensor current will fall off, even in an oxygen-free solution. For this reason an excessive zero current may indicate incomplete polarization. Insert the OxyProbe polarizing unit (P/N AM-9221)into the 4-pin connector of the sensor. Take care to align the pins first. OXYPROBE OXYPROBE Twist-lock the connector of the polarizing unit clockwise, in the direction of the arrow. 4-1

OXYPROBE OxyProbe Rebuild Instructions Chapter 5: Parts and Accessories Electrolyte, 25mL Bottle OXYPROBE Membrane Cartridge 14.0 x 1.0 mm -015 O-Ring Set for housing Conical Gasket Membrane Cartridges for 19 mm and 25 mm D.O. Sensors -014-014 KA2501 Single Cartridge Kit Single Membrane Cartridge Kit for 19mm & 25mm OxyProbes, includes 1ea. membrane cartridge, 1 ea. 25 ml bottle of electrolyte, 1 set of internal Si Rubber O-rings & 1 ea. Conical Gasket. Use O-ring sizes as follows: OxyProbe Rebuilds: 1 ea. 14.0 x 1.0 mm, - 014, & - 015 Other Rebuilds: 2 ea. - 014, & 1 ea. - 015 OXYPROBE OXYPROBE OXYPROBE OXYPROBE Four Cartridge Kit 14.0 x 1.0 mm -015-014 -014 14.0 x 1.0 mm -015 14.0 x 1.0 mm -015-014 -014-014 KA2504 Membrane Cartridge Kit for 19mm & 25mm OxyProbes, includes 4 ea. membrane cartridges, 1 ea. 25 ml bottle of electrolyte, 4 sets of internal Silicone O-rings & 4 ea. Conical Gaskets. 14.0 x 1.0 mm -015-014 -014 Use O-Ring Sizes for each sensor as follows: OxyProbe Rebuilds: 1 ea. 14.0 x 1.0 mm, - 014, & - 015 Other Rebuilds: 2 ea. - 014, & 1 ea. - 015-014 25 Piece Cartridge Pack OXYPROBE OXYPROBE OXYPROBE OXYPROBE x 5 25 pcs. KA2525 Membrane Cartridge Kit for 19mm and 25mm OxyProbes, includes 25 ea. membrane cartidges only, bulk packed. O-rings, gaskets, and electrolyte must be ordered separately. 5-1

Accessories AS-3140-C30-0025 AS-3140-C30-0250 D.O. Electrolyte Solution, 25 ml Bottle with Pour Spout Approx. 10 cartridge refills D.O. Electrolyte Solution, 250 ml Bottle with Pour Spout Approx. 100 cartridge refills 14,0X1-015 -014 AG-9206-10 Internal o-ring Kit, Silicone, for 19 mm and 25 mm D.O. Sensors, with Conical Gasket, 10 sets O-ring sizes: 14 x 1.0, -014, -015 AG-SR15-10 O-ring Kit, Silicone, External for D400 Series 25 mm sensors, pack of 10 O-Ring Size: R15 AG-S016-10 O-ring Kit, Silicone, External for D200 Series 19 mm sensors, pack of 10 O-Ring Size: -016 AG-E117-04 O-ring Kit, EPDM, External o-ring for 25 mm B.Braun Biotech sensors, pack of 4 AG-SF25-10 O-ring Kit, Silicone, Oversized o-ring for 25 mm housings and D.O. sensors, pack of 10 AM-9211 Conical Gasket Kit, Silicone, 4 pcs. 5-2

Replacement Parts OxyProbe CT25 CATHODE ASSEMBLY CT25-PT-050MP CT25-PT-130MP CT25-PT-200MP CT25-PT-300MP CT25-PT-400MP 70 mm Sensor 150 mm Sensor 220 mm Sensor 320 mm Sensor 420 mm Sensor AM-9213 Cathode Removal Tool, Dual Purpose for use with D200 (19 mm) & D400 (25 mm) series OxyProbe sensors AM-9212 Sensors Dust Cap 4-Pin Connector, Moisture Proof. For use with OxyProbes and all conventional D.O. Sensors. AM-9219 Dust Cap for Cable Plug, Moisture Proof. For use with OxyProbe Cables and All Conventional D.O. Sensor Cables. AM-9210 Retainer Nut, 316L SS, for use with CT25 Cathode Assembly 5-3

Replacement Parts AM-9202 4-Pin Connector for D400 Series 25 mm AM-9203 4-Pin Connector for D200 Series 19 mm AM-9204 AM-9266 Right Angle assembly for 25 mm Sensors Right Angle assembly for 19 mm Sensors AM-9386 Extended Right Angle assembly with hole for 25mm Sensors AM-9205 AM-9263 Screw, 316L SS and O-ring kit for use with 25 mm 4-pin connector O-ring size: -014, EPR Screw, 316L SS and O-ring kit for use with 19 mm 4-pin connector O-ring size: 10.4 x 1.0, EPDM 5-4

Accessories AM-9200 Retainer Ring, 316L stainless steel, for 25mm D.O. Sensors AM-9201 Retainer Ring, 316L stainless steel, for 19mm D200 Sensors E-1807-AAM-DZ 115VAC powered polarizing unit to keep up to four (4) OxyProbe sensors conditioned between uses. Also has a self test terminal. AM-9221 Battery-powered OxyProbe Polarizing Unit For keeping OxyProbe sensors conditioned between uses AM-9222 OxyProbe Simulator For troubleshooting and verifying installations, cables, and transmitters 5-5

See next pages for an exploded view and itemized parts list for the 19 mm and 25 mm OxyProbe D.O. Sensors 5-6

Figure 1 19 mm Sensor D200/D205 OxyProbe Assembly See next page for & 1 Model D200 2 3 4 8 Model D205 Note: Complete right angle assembly available as part number AM-9266 9 10 15 6 required 16 17 18 11 12 5 6 7 13 14 5-7

D200 & D205 OxyProbe Sensor Assembly ITEMIZED PART NUMBERS and DESCRIPTIONS ITEM 1 2 3 4a 4b 4c 4d 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PART NUMBER AM-9230 AM-9203 AM-9316 AM-9341 AM-9342 AM-9343 AM-9344 AM-9345 AM-9231 AM-9231 CT25-PT-130MP AM-9307 AM-9210 AM-9233 AM-9234 AM-9239 AM-9236 AM-9230 AM-9347 AM-9315 AM-9348 DESCRIPTION M2.5 x 0.45 x 1/4 Stainless Steel Screw, set of 3 4-Pin Connector, glass to metal seal with micro cable disconnect O-ring, EPDM, size: 10.4x1.0 Sensor Body, 316L stainless steel, for B = 150 mm D200/205 sensors Sensor Body, 316L stainless steel, for B = 220 mm D200/205 sensors Sensor Body, 316L stainless steel, for B = 320 mm D200/205 sensors Sensor Body, 316L stainless steel, for B = 420 mm D200/205 sensors O-ring, Silicone, size: AS-016 O-ring, Silicone, size: AS-014 O-ring, Silicone, size: AS-014 *Anode/Cathode w/ dual EPDM, AS-011 O-rings for B = 150 mm D200/205 O-ring, EPDM, size: AS-011 (included with item #7) Retainer Nut, 316L SS for CT25 Anode/Cathode assembly Conical Gasket, silicone Membrane Cartridge for D200 and D400 Series sensors Sensor Sleeve, 316L SS, D200 / D205 sensors O-ring, Silicone, size: AS-015 M2.5 x 0.45 x 1/4 Stainless Steel Screw, set of 3 (2 sets required) 4-Pin Connector with micro cable disconnect O-ring, EPDM, size: AS-014 Right Angle Adapter *Other lengths available for longer sensors 5-8

Figure 2 25 mm x 70 mm Sensor D400-B070 & D405-B070 OxyProbe Assembly See Itemized List for & Model D400 1 2 3 REQUIRED 3 7 4 8 9 5 6 10 11 MODEL D405 Note: Complete right angle assembly available as part number AM-9204 15 6 REQUIRED 12 16 17 18 13 14 5-9

D400-B070 & D405-B070 OxyProbe Sensor Assembly ITEMIZED PART NUMBERS and DESCRIPTIONS ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PART NUMBER AM-9230 AM-9202 AM-9315 AM-9232 AM-9231 AM-9231 CT25-PT-050MP AM-9307 AM-9210 AM-9233 AM-9234 AM-9235 AM-9237 AM-9236 AM-9230 AM-9349 AM-9315 AM-9238 DESCRIPTION M2.5 x 0.45 x 1/4 Stainless Steel Screw, set of 3 4-Pin Connector, glass to metal seal with micro cable disconnect O-ring, EPDM, size: AS-014 Sensor Body, 316L SS, 70 mm length D400/405 sensors O-ring, Silicone, size: AS-014 O-ring, Silicone, size: AS-014 *Anode/Cathode w/ dual EPDM, AS-011 O-rings for B = 70 mm D400/405 O-ring, EPDM, size: AS-011 (included with item #7) Retainer Ring Nut, 316L SS for CT25 Anode/Cathode assembly Conical Gasket, silicone Membrane Cartridge for D200 and D400 Series sensors Sensor Sleeve, 316L SS, for B = 70 mm D400 / D405 sensors O-ring, Silicone, size: AS-209 O-ring, Silicone, size: AS-015 M2.5 x 0.45 x 1/4 Stainless Steel Screw, set of 3 (2 sets required) 4-Pin Connector with micro cable disconnect O-ring, EPDM, size: AS-014 Right Angle Adapter for D405 Sensors *Other lengths available for longer sensors 5-10

Figure 3 25 mm x 150 mm Sensor D400-B150 & D405-B150 OxyProbe Assembly See Itemized List for & 1 3 REQUIRED Model D400 2 3 4 MODEL D405 Note: Complete right angle assembly available as part number AM-9204 15 6 Required 8 16 17 18 5 6 7 9 10 11 12 13 14 5-11

D400-B150 & D405-B150 OxyProbe Sensor Assembly ITEMIZED PART NUMBERS and DESCRIPTIONS ITEM 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 PART NUMBER AM-9230 AM-9202 AM-9315 AM-9346 AM-9237 AM-9231 AM-9231 CT25-PT-130MP AM-9307 AM-9210 AM-9233 AM-9234 AM-9239 AM-9236 AM-9230 AM-9349 AM-9315 AM-9238 DESCRIPTION M2.5 x 0.45 x 1/4 Stainless Steel Screw, set of 3 4-Pin Connector, glass to metal seal with micro cable disconnect O-ring, EPDM, size: AS-014 Sensor Body, 316L SS, B = 150 mm D400/405 sensors O-ring, Silicone, size: AS-209 O-ring, Silicone, size: AS-014 O-ring, Silicone, size: AS-014 *Anode/Cathode w/ dual EPDM, AS-011 O-rings for B = 150 mm D400/405 O-ring, EPDM, size: AS-011 (included with item #8) Retainer Nut, 316L SS for CT25 Anode/Cathode assembly Conical Gasket, silicone Membrane Cartridge for D200 and D400 Series sensors Sensor Sleeve, 316L SS, for B = 150 mm D400 / D405 sensors O-ring, Silicone, size: AS- 015 M2.5 x 0.45 x 1/4 Stainless Steel Screw, set of 3 (2 sets required) 4-Pin Connector, with micro cable disconnect O-ring, EPDM, size: AS-014 Right Angle Adapter for D405 sensors * Other lengths available for longer sensors 5-12

Appendix A: Technical Specifications Operating Conditions ATING CONDITIONS Ambient Temperature -20 C to +60 C Relative Humidity 0 90% Measure ME Display Range Display Resolution Repeatability 0 14 ph (Can measure down to -3 ph) -1500 mv 1500 mv -20 C to 200 C (- 4 F 392 F) 0.01 ph / 0.1 ph (adjustable) 1 mv 0.1 C ±0.02 ph ±1 mv ±0.2 C Temperature Sensor Pt 100 / Pt 1000 Automatic Temperature -20 to 200 C Compensation Range -4 to 395 F Temperature Compensation Nernst Range Ultrapure water Other tables Electrode Type Cable Length Sensor Inputs Input Impedance Impedance Measurement - glass (with or without preamplifier) - antimony - redox - programmable (slope + Uiso + phiso) 0 to 25 m (high impedance) 0 to 100 m (low impedance) Differential Measurement > 10 12 Ω Glass: 5MΩ... 1GΩ Reference: 100Ω... 1MΩ A-1