MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors for Cellpack separable connectors

Similar documents
KEVA B Indoor voltage sensor

MEDIUM VOLTAGE PRODUCTS. KEVA C Indoor voltage sensors

Medium Voltage Products. KECA 80 C85 Indoor current sensor

KEVCY 24 RE1; KEVCY 24 RF1 Indoor combined sensor; Indoor voltage sensor

MEDIUM VOLTAGE PRODUCT. TJP 6.1, TJP 6.2 Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TJP 5.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. TPE 6x.xx Indoor supporting current transformers

MEDIUM VOLTAGE PRODUCT. TJP 7.x Indoor voltage transformers

MEDIUM VOLTAGE PRODUCT. KOKM Cable current instrument transformers Instruction for Installation, use and maintenance

MEDIUM VOLTAGE PRODUCT. PARAMETERS GUIDE How to specify the indoor instrument transformers correctly

PRODUCT FOR HIGH VOLTAGE APPLICATION. Current transformers for Gasinsulated. Instructions for installation, use and maintenance

Products for High Voltage Application. AT35, AT38, AT41 Indoor current transformer for oil-immersed power transformers

AT Current Instrument Transformer Instructions for installation, use and maintenance

RTU560. Multimeter 560CVD03. Power Measuring Display. Characteristics. Application. Data Sheet Multimeter 560CVD03

Three-phase monitoring relays CM-PFE and CM-PFE.2

Instrument transformers for indoor applications. Product overview. Instrument transformers for indoor applications.

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Digital Indicator DS 96/48 PK

Multimeter 500CVD21 RTU500 series

Sensor Technology. Applications for medium voltage

Modem 1200 baud 500FSD10 EDS500 series - FSK modems

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Three-phase monitoring relay CM-PFS

Three-phase monitoring relay CM-PVE

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

C1901 Single Pen Circular Chart Recorder. C1901 a rugged, reliable recorder for all single channel recording applications

ChuteMaster Microwave-blocked chute detection and point level instrument

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Liquid level monitoring relay CM-ENS.2x

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-SDS.22

Three-phase monitoring relay

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Digital Indicator DS 96/24

ABB MEASUREMENT & ANALYTICS DATA SHEET. Ultrasonic level LST400 Open channel flow transmitter

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Transformers connected via a cable Overvoltage protection

The Polytransformer. The Multivoltage Substation Power Transformer

Three-phase monitoring relay CM-PBE

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

KINAX SR 719 Programmable Transmitter for Position Feedback

CEC VIBRATION TRANSMITTER

Pluggable interface relays CR-U Universal relays

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

LST400 Ultrasonic level / open channel flow transmitter

T 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

All-or-nothing relay RH(M) 1000 in plug-in case and case for top-hat rail or wall mounting

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

Power transformers. Shunt reactors Proven history for future success

Smart Termination TECHNICAL SPECIFICATIONS CURRENT VOLTAGE INSTRUMENTRANSFORMER

REF42plus HMI Cutting Tool Operating Guide

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Selection of MO surge arresters Overvoltage protection

1-830 SERIES DISPLACEMENT TRANSMITTER

Capacitive level meters CLM 40 INSTRUCTIONS MANUAL. průmyslová elektronika

ABB MEASUREMENT & ANALYTICS. TALYS ASP500 series Flexible analyzer for real-time control of chemical processes

P2 H2 NAMEPLATE 6 HOLES M8-10 M SCREW S1 1S2 1S3 X1 X2 X3 PARALLEL HIGH RATIO

Online data sheet UE43-3AR3D2 UE43-3AR SAFETY RELAYS

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

LST100 Ultrasonic level transmitter for upstream oil and gas

TD 1000 PLUS. Secondary Injection Relay Test Set. Designed for testing relays and transducers

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

HAWK5000 Operators Manual

SensyTemp TSBA (BA R) Resistance thermometer for building automation, machine construction and environmental engineering

World-Class Accuracy & Measurement Range (40 Conventional Models)

Online data sheet UE48-3OS2D2 UE48-3OS SAFETY RELAYS

Online data sheet UE48-2OS2D2 UE48-2OS SAFETY RELAYS

RING CORE CURRENT TRANSFORMERS FOR LOW VOLTAGE TYPE AOS USER MANUAL

Electronic Products and Relays Selection Table Signal Converters CC-Range

Current / residual current and voltage transformers. Current / residual current and voltage transformers

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Time relay RXKA 1. (xx jpg) RXKA 1

Current and voltage measuring relays RXIK 1, RXEEB 1 and RXIB 24

Technical Description. Wireless Proximity Switches Antenna WAT100

Power supply CP-D 12/2.1

Modem 9600 baud 500FSD11 EDS500 series - FSK modems

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

50-SDMS-01 SPECIFICATIONS FOR

N. TEST TEST DESCRIPTION

PUV3402 LED multiwave photometer A new approach to online process photometry

Transformer and generator time-overexcitation relay and protection assemblies RXLK 2H and RALK

Current and Voltage (potential) Instrument transformers Instruction for installation, use and maintenance

Transcription:

MEDIUM VOLTAGE PRODUCTS KEVA C Indoor voltage sensors for Cellpack separable connectors

2 KEVA C INDOOR VOLTAGE SENSORS FOR CELLPACK SEPARABLE CONNECTORS 01 Resistive divider principle 02 IED and sensor Parameters for Application Rated primary voltage of application Sensor Parameters Value up to 24 kv Value U P U s = R 2 U p Rated primary voltage, U pn 22/ 3 kv R 1 + R 2 Highest voltage for equipment, U m 24 kv Rated power frequency withstand voltage Rated lightning impulse withstand voltage Rated transformation ratio, K n for voltage measurement Voltage accuracy class Length of cable 50 kv 125 kv 10 000:1 0.5/3P 2.2; 5 m 01 U S In all cases, the transmitted output signal reproduces the actual waveform of the primary voltage signal. Sensor principles Electronic Instrument Transformers (Sensors) offer an alternative way of making the voltage measurement needed for the protection and monitoring of medium voltage power systems. Sensors based on alternative principles have been introduced as successors to conventional instrument transformers in order to significantly reduce size, increase safety, and to provide greater rating standardization and a wider functionality range. These well known principles can only be fully utilized in combination with versatile electronic relays. Sensor characteristics Construction of ABB s voltage sensors is done without the use of a ferromagnetic core. This fact results in several important benefits for the user and the application. The main benefit is that the behavior of the sensor is not influenced by non-linearity and width of hysteresis curve, which results in a highly accurate and linear response over a wide dynamic range of measured quantities. A linear and highly accurate sensor characteristic in the full operating range enables the combination of metering and protection classes in one device. Protection and control IEDs (Intelligent Electronic Devices) Protection and control IEDs incorporate the functions of a traditional relay, as well as allow new additional functions. The information transmitted from the sensors to the IED is very accurate, providing the possibility of versatile relay functionality. However, the IED must be able to operate with sufficient accuracy at a sensor s low input signal level. Modern IEDs (such as ABB s 615 series relays) are designed for such sensor use. Modern digital apparatuses (microprocessor based relays) allow protection and measurement functions to be combined. They fully support voltage sensing realized by the single sensor with double the accuracy class designation (e.g.: voltage sensing with combined accuracy class 0.5/3P). Voltage sensor Voltage measurement in KEVA C sensors is based on the resistive divider principle. The output voltage is directly proportional to the input voltage: 02

3 03 KEVA C application 04 Combined accuracy class Differences between Sensors and Instrument Transformers There are some noticeable differences between Sensors and conventional Instrument Transformers: Linearity Due to the absence of a ferromagnetic core the sensor has a linear response over a very wide primary voltage range. Example of voltage measurement range for metering accuracy class 0.5 and protection accuracy class 3P: The accuracy limits are described on the graph below. 03 ε[%] +6% +3% Protection accuracy limit class 3P Sensor variants +0.5% Metering accuracy limit class 0.5 Sensor type designation Metal coated (conductive surface) Picture Sensor linear characteristic 0.02*U pn 0.8*U pn U pn 1.2*U pn 1.9*U pn -0.5% U p KEVA 24 C10 KEVA 24 C25-3% -6% KEVA 24 C10c KEVA 24 C25c Tab. 1. Sensor design variants (with and without conductive surface) Sensor type designation KEVA 24 C10 KEVA 24 C10c KEVA 24 C25 KEVA 24 C25c Cable connector Manufacturer Cellpack Cellpack Type CTS-S 630A 24kV CTS 630A 24kV CTKS 630A 24kV Tab. 2. Sensor variants and use in cable connectors Connecting screw for sensor M16 M16 Note: For use in alternative cable connectors please contact ABB. 04 Rated parameters Because the sensors are highly linear within a very wide range of voltages, the same single sensor can be used for the va rious rated voltages associated with each specific application up to the specified maximum voltage for equipment. There is no need to specify other parameters such as burden etc. since they are standard over the defined range. To achieve the correct function of the protection and control IED, the selected rated voltage as well as the rated transformation ratio, must be properly set into the IED. Correction factors The amplitude and phase error of a voltage sensor is, in practice, constant and independent of the primary voltage. Due to this fact it is an inherent and constant property of each sensor and it is not considered as unpredictable and influenced error. Hence, it can be easily corrected in the IED by using appropriate correction factors, stated se parately for every sensor.

4 KEVA C INDOOR VOLTAGE SENSORS FOR CELLPACK SEPARABLE CONNECTORS 05 Example of a sensor label 06 Connector RJ-45 Values of the correction factors for the amplitude and phase error of a voltage sensor are mentioned on the sensor label (for more information please refer to Instructions for installation, use and maintenance) and should be uploaded without any modification into the IED before the sensors are put into operation (please check available correction in the IED manual). To achieve required accuracy classes it is recommended to use both correction factors (Cfs): amplitude correction factor (au) and phase error correction factor (pu) of a voltage sensor. Connector adapters To provide connectivity between a sensor with a RJ-45 cable connector and IEDs with Twin-BNC connectors a group of adapters were designed. To provide connectivity between current and voltage sensors with RJ-45 cable connectors and IEDs with RJ-45 connector the coupling adapter was designed. The use of connector or coupling adapters has no influence on the current and/or voltage signal and accuracy of the sensor with the cable. For more information about connector adapters and coupling adapter refer to Doc. No. 1VLC000710 - Sensor accessories. Standards IEC 60044-7 (1999-12) Instrument transformers - Part 7: Electronic voltage transformers Highest voltage for equipment and test voltages Highest voltage for equipment, U m : 24 kv Rated power frequency test voltage: 50 kv Rated lightning impulse test voltage: 125 kv 05 Secondary cables The sensor is equipped with a cable for connection with the IED. The cable connector is type RJ-45. The sensor accuracy classes are verified up to the connector, i.e. considering also its secondary cable. These cables are intended to be connected directly to the IED, and subsequently neither burden calculation nor secondary wiring is needed. Every sensor is therefore accuracy tested when equipped with its own cable and connector. Voltage sensor, rated values Rated primary voltage, U pn : 22/ 3 kv Rated frequency, f r : 50/60 Hz Accuracy class: 0.5/3P Rated burden, R br : 10 MΩ Rated transformation ratio, K n : 10 000:1 Rated voltage factor, k u : 1.9/8h Temperature category Operation: Transport and storage: Cable Length: Connector: Grounding wire length: -25 C/+80 C -40 C/+80 C 2.2; 5 m RJ-45 (CAT-6) 0.5 m 06

5 Sensor type Supported type of cable connector Sensor ordering data Manufacturer KEVA 24 C10 Cellpack CTS-S 630A 24kV 1VL5400061V0101 (2.2 m) Type 1VL5400061V0103 (5 m) KEVA 24 C10c 1VL5400061V0201 (2.2 m) KEVA 24 C25 Cellpack CTS 630A 24kV CTKS 630A 24kV 1VL5400061V0203 (5 m) 1VL5400079V0101 (2.2 m) 1VL5400079V0103 (5 m) KEVA 24 C25c 1VL5400079V0201 (2.2 m) 1VL5400079V0203 (5 m) Tab. 3. Sensor overview. Note: For use in alternative cable connectors please contact ABB.

6 KEVA C INDOOR VOLTAGE SENSORS FOR CELLPACK SEPARABLE CONNECTORS Dimensional Drawings KEVA C KEVA 24 C10 and KEVA 24 C10c Outline drawing number: 2RKA015654 Weight: 0.85 kg

7 KEVA 24 C25 and KEVA 24 C25c Outline drawing number: 2RKA019522 Weight: 0.85 kg

CONTACT US ABB s.r.o. EPMV Brno Videnska 117, 619 00 Brno, Czech Republic Tel.: +420 547 152 082 +420 547 152 614 Fax: +420 547 152 626 E-mail: info.ejf@cz.abb.com www.abb.com NOTE We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents - in whole or in parts - is forbidden without prior written consent of ABB. Copyright 2017 ABB All rights reserved 1VLC000724 Rev.-, en 2017.09.12