FAULT PROTECTION OF A LOOP TYPE LOW VOLTAGE DC BUS BASED MICROGRIDS

Similar documents
Fault Detection and Isolation of a Loop Type Low Voltage DC Bus Microgrid

Faults Detection and Isolation in Demand Side of Direct Current Microgrid

TRANSFORMERLESS THREE LEVEL DIODE CLAMPED INVERTER FOR SINGLE PHASE GRID CONNECTED PHOTOVOLTAIC SYSTEM

VERY HIGH VOLTAGE BOOST CONVERTER BASED ON BOOT STRAP CAPACITORS AND BOOST INDUCTORS USED FOR PHOTOVOLTAIC APPLICATION USING MPPT

ACTIVE POWER ELECTRONIC TRANSFORMER A STANDARD BUILDING BLOCK FOR SMART GRID

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

Renewable Energy Integrated High Step-Up Interleaved Boost Converter for DC Microgrid Applications

Grid-Tied Interleaved Flyback Inverter for Photo Voltaic Application

Internal DC Short-Circuit Fault Analysis and Protection for VSI of Wind Power Generation Systems

Modelling and Simulation of High Step up Dc-Dc Converter for Micro Grid Application

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 01, 2016 ISSN (online):

Active Power Sharing and Frequency Control of Multiple Distributed Generators in A Microgrid

INTERLINE UNIFIED POWER QUALITY CONDITIONER: DESIGN AND SIMULATION

Fuzzy Logic Based MPPT for Wind Energy System with Power Factor Correction

FUZZY CONTROL OF SHOOT THROUGH TIME OF SINGLE STAGE BOOST INVERTER WITH COUPLED INDUCTOR FED BY A FUEL CELL

EMERGING distributed generation technologies make it

Simulation of Single Phase Grid Connected Photo Voltaic System Based On PWM Control Of Switched Boost Inverter For DC Nanogrid Applications

A Solar Powered Water Pumping System with Efficient Storage and Energy Management

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

A BRIDGELESS CUK CONVERTER BASED INDUCTION MOTOR DRIVE FOR PFC APPLICATIONS

State of Charge (SOC)-Based Active Power Sharing Method for Distributed Generations in an Islanded Microgrid

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

An Advanced Power Conditioning Unit for Power Management in Grid Connected PV Systems

Modeling and simulation for PV, Fuel cell Based MICROGRID under Unbalanced Loading Conditions

Enhancement of Fault Current and Overvoltage by Active Type superconducting fault current limiter (SFCL) in Renewable Distributed Generation (DG)

Voltage Support and Reactive Power Control in Micro-grid using DG

STUDY OF CIRCULATING CURRENT PHENOMENA IN MULTIPLE PARALLEL INVERTERS OPERATING IN MICROGRID

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

SIMULATION OF MULTI CONVERTER BASED UNIFIED POWER-QUALITY (MC-UPQC) CONDITIONING SYSTEM ON VOLTAGE STABILITY OF RADIAL DISTRIBUTION SYSTEMS

A New Network Proposal for Fault-Tolerant HVDC Transmission Systems

A Fuzzy Controlled High Voltage Boosting Converter Based On Boost Inductors and Capacitors

Coordinated Control Strategy of Solar Photovoltaic Generators with MPPT and Battery Storage in Micro Grids

IOSR Journal of Electrical and Electronics Engineering (IOSR-JEEE) e-issn: ,p-ISSN: , PP

Single Phase Bidirectional PWM Converter for Microgrid System

Matlab Simulation of a High Step-Up DC-DC Converter for a Micro grid Application

Islanding Detection Technique based on Simulation of IEEE16 Bus System

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

High Efficiency Single Phase Transformer less PV Multilevel Inverter

A Dual Half-bridge Resonant DC-DC Converter for Bi-directional Power Conversion

Phase Shift Modulation of a Single Dc Source Cascaded H-Bridge Multilevel Inverter for Capacitor Voltage Regulation with Equal Power Distribution

SINGLE PHASE THIRTY ONE LEVEL INVERTER USING EIGHT SWITCHES TOWARDS THD REDUCTION

A Modified Single-Phase Quasi z source converter

SINGLE PHASE MULTI STRING FIVE LEVEL INVERTER FOR DISTRIBUTED ENERGY SOURCES

Dynamic Voltage Restorer for Voltage Compensation and Fault Current Limiting Functions

Improved Transient Compensation Using PI-SRF Control Scheme Based UHVDC For Offshore Wind Power Plant

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

A Novel Cascaded Multilevel Inverter Using A Single DC Source

A New Closed Loop AC-DC Pseudo boost Based Converter System for CFL

ANALYSIS OF OPTIMAL LOCATION OF SUPERCONDUCTING FAULT CURRENT LIMITER FOR THE SMART GRID

Design of Interline Dynamic Voltage Restorer for Voltage Sag Compensation

Islanding Detection Method Based On Impedance Measurement

Reducing the Fault Current and Overvoltage in a Distribution System with an Active Type SFCL Employed PV System

Kalman Filter Based Unified Power Quality Conditioner for Output Regulation

Quasi Z-Source DC-DC Converter With Switched Capacitor

Protect and survive. Fault protection analysis in low-voltage DC microgrids with photovoltaic generators

SVPWM Technique for Cuk Converter

HIGH STEP UP SWITCHED CAPACITOR INDUCTOR DC VOLTAGE REGULATOR

PV MICROINVERTER TOPOLOGY USING SOFT SWITCHING HALF- WAVE CYCLOCONVERTER

COORDINATED CONTROL STRATEGY OF SOLAR PHOTOVOLTAIC GENERATORS WITH MPPT AND BATTERY STORAGE IN MICRO GRIDS

ISSN Vol.07,Issue.06, July-2015, Pages:

Implementation of a Voltage Multiplier based on High Step-up Converter using FLC

FPGA based Transformer less grid connected inverter using boost converter for Photo voltaic applications

A Five-Level Single-Phase Grid-Connected Converter for Renewable Distributed Systems

Comparison Of DC-DC Boost Converters Using SIMULINK

Design and Simulation of superconducting fault current limiter

MODELING AND SIMULATON OF THREE STAGE INTERLEAVED BOOST CONVERTER BASED WIND ENERGY CONVERSION SYSTEM

Poornima G P. IJECS Volume 3 Issue 6 June, 2014 Page No Page 6453

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

Performance Analysis of Various Types of Fault Current Limiters Using PSCAD

CONTROL STRETEGY FOR POWER MANAGEMENT IN GRID CONNECTED MICROGRID WITH RENEWABLE ENERGY SOURCES

Modelling of Five-Level Inverter for Renewable Power Source

Multilevel inverter with cuk converter for grid connected solar PV system

Implementation of high-power Bidirectional dc-dc Converter for Aerospace Applications

ISSN Vol.04,Issue.07, June-2016, Pages:

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

High Gain Step Up DC-DC Converter For DC Micro-Grid Application

Analysis of An Non-Isolated Interleaved Buck Converter with Reduced Voltage Stress And high Step down Ratio

A NEW CIRCUIT TOPOLOGY FOR OPEN CIRCUIT AND SHORT CIRCUIT FAULT TOLERANT DC-DC CONVERTER

Multiport Converter for Micro Grid Application

Minimized Standby Power Scheme For Forward Converter With Isolated Output- Feedback

LOCATING fault by traditional method in a distribution. Cable Fault Location in a DC Microgrid Using Current Injection Technique

Power Transmission of AC-DC Supply in a Single Composite Conductor

Switched Coupled Quasi Z Source Inverter for Photovoltaic Power Generation System

One-Cycle Control of Interleaved Buck Converter with Improved Step- Down Conversion Ratio

Transformerless Grid-Connected Inverters for Photovoltaic Modules: A Review

Photovoltaic Solar Plant As A Statcom During Dark Periods In A Distribution Network

HALF BRIDGE CONVERTER WITH WIDE RANGE ZVS

A NOVEL APPROACH TO ENHANCE THE POWER QUALITY USING CMLI BASED CUSTOM POWER DEVICES

Superconducting Fault Current Limiter for Energy Storage Protection in a Micro Grid

Doãn Văn Đông, College of technology _ Danang University. 2. Local Techniques a. Passive Techniques

Hybrid Anti-Islanding Algorithm for Utility Interconnection of Distributed Generation

A Five Level Inverter for Grid Connected PV System Employing Fuzzy Controller

Fuzzy Controlled Capacitor Voltage Balancing Control for a Three Level Boost Converter

A Single Switch High Gain Coupled Inductor Boost Converter

SINGLE PHASE INVERTER WITH HF TRANSFORMER FOR PV APPLICATION

Protection of Microgrids Using Differential Relays

Simulation of Dual Active Bridge Converter for Energy Storage System Vuppalapati Dinesh 1, E.Shiva Prasad 2

Transcription:

INTERNATIONAL JOURNAL OF ELECTRICAL ENGINEERING & TECHNOLOGY (IJEET) Proceedings of the International Conference on Emerging Trends in Engineering and Management (ICETEM14) ISSN 0976 6545(Print) ISSN 0976 6553(Online) Volume 5, Issue 12, December (2014), pp. 240-247 IAEME: www.iaeme.com/ijeet.asp Journal Impact Factor (2014): 6.8310 (Calculated by GISI) www.jifactor.com IJEET I A E M E FAULT PROTECTION OF A LOOP TYPE LOW VOLTAGE DC BUS BASED MICROGRIDS E.G.CHINJU 1, S.RESHMILA 2 1 Dept. of EEE, Sree Narayana Gurukulam College of Engineering, Kolenchery, Ernakulam, Kerala, India 2 Dept. of EEE, Sree Narayana Gurukulam College of Engineering, Kolenchery, Ernakulam, Kerala, India ABSTRACT The micro grid system can be divided in to AC micro grid and DC micro grid.as compared to DC system, the traditional AC system have the years of practical experience and standards. However the problem with the AC grid still persists. The DC micro grid system has lesser number of conversion stages and it reduces the losses, so the system efficiency becomes increases. But the fault protection of DC system is very difficult because when a fault occurs, it completely de-energizes the system. A loop-type dc-bus-based micro grid system against various faults is presented in this paper. The goal of the proposed system is to detect the fault in the DC bus and to separate the faulty section only so that the healthy portion keeps operating without any disturbances. The proposed scheme consists of one master controller and two slave controllers which are connected at two ends of the transmission line. By using the differential relaying principle the controller opens the power switches during fault. In addition, a converter protection is also provided which acts as a back up protection for the feeder. The MATLAB Simulink results are presented for the proposed concepts. Keywords: DC Distribution, Fault Protection, Micro Grids, Power System Protection, Sold State Switch 1. INTRODUCTION The demand of electricity increases day by day and which causes an imbalance between supply and demand. Now a days, many distributed power system have been researched and developed to meet this increasing demand by using renewable energy resources such as photo voltaic systems, wind energy systems and other distributed energy resources [1],[2]. The application of distributed resources in the electric power system opens new possibilities. Because the distributed systems posses many advantages such as better operational and economical generation efficiency, capacity to relief transmission and distribution, improved reliability, power quality and eco-friendliness. Microgrid is an isolated electric power system that uses bidirectional communication between distributed energy resources, loads and control systems to improve power quality, optimal use of renewable energy resources and possibility of consumers to manage their electricity usage and minimize their expenses [3],[4]. The microgrid can be classified into AC bus and DC bus systems depending on the characteristics of the grid supply voltage. Currently all the commercially installed micro grids are AC because they are simple and easy to control [6]. Also they have the benefit to utilize existing AC grid technologies. But AC system faces many drawbacks such as stability, the need for reactive power control, reliability problems and the increasing number power electronic converters is responsible of increasing waveform distortions and power losses [5],[7]. There is more scope for DC bus systems instead of AC systems because most distributed generation sources such as PV, fuel cells and variable speed wind power units directly generate DC power. Moreover the DC systems do not have the problems like skin effect, waveform distortion that AC systems do. By using DC power as a medium, the typical ac-dc-ac power conversion stages can be reduced and which in turn reduces cost and size of the system [7]. A diagram of DC bus micro-grid is shown in Fig 1. 240

Fig.1.DC bus microgrid However, the DC distribution system needs further development in the field of protection. Due to the lack of guidelines and experience, protection has been challenging in DC systems [8].This paper presents a fault protection method for low voltage DC microgrid systems. The primary goal of the proposed scheme is to detect the fault in the bus segment between the devices and then to isolate the faulted section only, so that the other healthy segment continue to provide power to the load and which in turn maintaining the supply continuity to the load. To achieve this, a loop type dc bus based microgrid system is proposed. The loop type system has good efficiency if the distribution system is not so long. The secondary function of the proposed scheme is to protect the converter from the fault occurs in the DC bus segment. The converter protection in this scheme acts as a back up protection for the feeder protection. 1.1. Low Voltage DC Microgrid The Low Voltage DC (LVDC) micro grid system is relatively a new concept in distribution system. As compared to traditional AC distribution system, LVDC systems have many advantages. LVDC micro grid has been used in office buildings with sensitive computer loads and rural power systems [9]. And also the sources, loads and energy storage can be connected through simpler and efficient power electronic interfaces. The losses in the DC system are less because it requires lesser number of power conversion stages and it can deliver 1.41 times more power than an AC system for the same cable [10]. When comes to system protection, it is difficult in DC system because of no current zero crossing. The possible faults in a DC system are line to ground fault and line to line fault [8]. A well designed protection method is necessary to ensure reliable operation of the LVDC microgrid. The common practice in DC system is to install protection on AC side where AC and DC grid is connected. The protective devices commercially available for LV systems are DC protective switch gear as well as conventional AC devices such as CBs and fuses. But during fault the AC CBs are problematic because this scheme shut down the entire system and which causes unnecessary outages in the healthy system [11],[112]. Fuses are slow thermal devices and they do not have the ability to distinguish whether a fault is temporary or permanent. To overcome these limitations, now a day s solid-state CBs such as IGBTs are used in DC system. These are bidirectional solid state switches and they offer fast switching operation and high short circuit current capability [13]. 1.2.Converter Protection Both AC/DC and DC/AC converters are used to interface different sources and loads to the DC bus. To achieve high efficiency, the converter must be able to handle voltage variations in the DC grid. The internal switch fault in the converter cause short circuit fault [7]. In most cases, this fault cannot be cleared and the only solution is to replace the device from the system. Also due to the fault in the DC bus side, there is a chance of fault occur in the converter. The fault current withstanding capacity of converter is only twice the converter full load rating. So the fault current must be detected and extinguished as quickly as possible [8]. 2. PROPOSED FAULT PROTECTION SCHEME 2.1. Proposed Loop Type DC Bus System The proposed system does not require a complete isolation of the system; only the affected area is separated and de-energized. The healthy buses keeps operating, provide a power to the load and maintaining the supply continuity. A loop-type dc-bus-based micro grid system against various faults is presented in this paper. The loop type system offers good efficiency if the distribution line is not so long [14]. The proposed scheme consists of one master controller and two 241

slave controllers, freewheeling branches between each line and ground. The slave controllers connected at two ends of the transmission line. The diagram of proposed protection scheme is shown in fig.2. Fig.2. Proposed protection scheme The figure shows protection of one bus segment only. The implementation of proposed scheme is shown in fig 3. Snubber circuits are used to protect the solid state CBs from voltage transients. Fig.3.Implementation of proposed scheme. 2.2. Detection and Isolation of Fault In this scheme, the fault detection and isolation is based on the differential relaying principle. The slave controller read the current at two ends of the line connecting two components and provides this information in to master controller. Under normal condition, input and output currents are nearly same. If there is any fault occurs in the line, there is a current difference. When the difference exceeds a critical value, the master controller gives an appropriate command to open the IGBT switches, so that the faulted line is isolated from the healthy section and system can continue to operate on the loop-type bus [7]. After isolation, the fault current in the faulted bus segment flows through the freewheeling diodes and resistance. The freewheeling path resistance determines fault current extinction. When the resistance is large, the fault current extinguished very quickly [7]. The path of current during fault and freewheeling time is shown in fig 4. 242

(c) (d) Fig.4.Fault current path and its extinction in proposed scheme. Line to ground fault. Fault current extinction in line to ground Fault. (c) Line to line fault. (d)fault current extinction in line to line fault. This is the primary protection of the feeder. If this protection fails to clear the fault, the back up protection must operate and protect the feeder. This is similar to the conventional method. There is a main switch in between converter in the source side and DC bus. If the primary protection fails to clear the fault, the main switch just open and cut the supply to the DC bus and hence de-energizes the complete system as like in the conventional method. In all other cases, the main switch in the closed condition. This is also a protection for the converter. Because if the feeder protection is fails to clear the fault, there is a large fault current in the DC bus. The converter is directly connected to the bus and so have low impedance. When the DC link voltage becomes almost zero, the fault current will flows through the converter and leads to failure of the converter. So the fault current must be detected and extinguished as quickly as possible 3. SIMULATION RESULTS A MATLAB simulation has been performed for a LVDC microgrid system. It consists of two sources; three phase AC and battery are connected to feed a common load. A Three phase 440 V supply is given to AC/DC converter connected at the source side. A line to ground fault is created in the middle of the bus segment A only. The simulation circuit is shown in fig.5. The input source is a three phase AC which connected to the DC bus through an AC/DC converter. Battery source is connected between line segment B and line segment C. These two sources are connected to a common load. The simulation parameters are given in the table 1. The main switch is connected in between the converter and the DC bus. 243

Fig.5.Simulation circuit. Complete diagram of Proposed scheme. Line segment A TABLE 1: Simulation parameters A positive line to ground fault occurs in the middle of the bus segment A at 0.5ms. The load voltage with and without protection is shown in fig.8.without protection, the load voltage drops to zero after fault is shown in fig 244

6,when protection is used, the voltage is quickly restored after the separation of the faulted segment which is shown fig.6. Fig.6.Load voltage. without protection.with protection When the IGBTs in the line segment A open due to fault, the fault current freewheels and extinguished through the resistor is shown in fig 7. Fig.7.Fault current in the freewheeling path Fig.8 and fig.9 shows the source side bus current and load side bus current for a line to ground fault with and without protection. The bus current is high during faulty condition and goes to zero after separating the bus. Fig.8. Source side bus current Without protection With protection 245

Fig.9.Load side bus current Without protection With protection If the IGBTs in the segment A fails to clear the fault, the main switch just open and cut the supply to the DC bus and de-energizes the complete system.fig.10.shows the main switch operation. The gating signals to the main switch are shown in fig.10 and the output voltage is shown in fig.10. Fig.10.Main switch operation under failure of protection.gating signals. Load voltage In the fig10, first shows the fault, second one is status of switches in the segment A and third shows the gating signal to the main switch. A fault is occurs at 0.5ms, from the figure it can be seen that, after the fault also the IGBTs in the segment A are conducting. So to protect the converter and the complete system, it is necessary to switch off the main switch immediately. So a gating signal is send to switch off the main switch, which is shown in the third figure. Then the out put voltage goes to zero. If the protection of line segment is proper, the main switch operation is shown in fig11.the gating signals to the main switch and corresponding load voltages are shown in fig11. and fig 11. respectively. Fig.11.Main switch operation under proper protection.gating signals. Load voltage 246

A fault is occurs at 0.5ms and at the same time itself, the gating signals of the switches goes to zero which is shown in second portion of the fig11. Therefore the already conducting switches in the line segment turned off and separate the segment from the healthy system. The third portion shows the gating signal. So the main switches are conducting to provide a power to the load through other healthy bus segments. Then the output voltage restored after the separation of the faulted segment. 4. CONCLUSION The application of distributed resources opens new possibilities in the electric power system. There is more scope for DC microgird systems. But the protection of DC bus is more challenging. The proposed protection scheme avoids the complete shut down of the system and isolates the faulted section only so that the other healthy segment continue to provide power to the load and which in turn maintaining the supply continuity to the load. A loop type DC bus based microgrid system was utilized. This provides additional protection to the converters. If the primary protection fails to clear the fault, the main switch which is connected in between source converter and the DC bus, just open and cut the supply to the DC bus and hence de-energizes the complete system as like in the conventional method. This is act as a back up protection for the feeder. The proposed protection concepts have been validated by MATLAB simulink. This scheme can be applied to green buildings with sustainable energy resources, data center with a server array etc. REFERENCES [1] R. Dugan, T. McDermott, Distributed generation, IEEE Ind. Appl. Mag., vol. 8, no. 2, pp. 19-25, Mar./Apr. 2002. [2] F. Blaabjerg, R. Teodorescu, M. Liserre, and A. Timbus, Overview of control and grid synchronization for distributed power generation systems, IEEE Trans. Ind. Electron., vol. 53, no.5, pp. 1398 1407, Oct. 2006. [3] H. Farhangi: The Path of the Smart Grid, IEEE Power and Energy Magazine, Vol. 8, No. 1, pp. 18-28, Jan.- Feb. 2010 [4] E. Santacana, G. Rackliffe, Xiaoming Feng: Getting Smart, IEEE Power and Energy Magazine, Vol. 8, No. 2, pp. 41-48, 2010 [5] N. Hatziargyriou; H. Asano; R. Iravani; C. Marnay: "Microgrids", Power and Energy Magazine, IEEE, Vol.5, No.4, pp.78-94, July-Aug. 2007. [6] J. Park, J. Candelaria, Fault detection and isolation in low voltage DC-Bus microgrid system IEEE Trans. Power Del., vol. 28, no. 2, pp. 779-787, Apr. 2013 [7] M. Saeedifard, M. Graovac, R. Dias, and R. Iravani, DC power systems: Challenges and opportunities, in Proc. IEEE Power Energy Soc.Gen. Meeting, July 2010, pp. 1 7. [8] J.Candelaria and J.-D. Park, VSC-HVDC system protection: A review of current methods, in Proc. IEEE/Power Energy Soc. Power Syst. Conf. Expo., Mar. 2011, pp. 1 7. [9] Salomonsson, L. Soder, and A. Sannino, Protection of lowvoltage DC microgrids, IEEE Trans. Power Del., vol. 24, no.3, pp. 1045 1053, Jul. 2009. [10] P. Salonen, P. Nuutinen, P. Peltoniemi, and J. Partanen, LVDC distribution system protection: Solutions, implementation and measurements, in Proc. 13th Eur. Conf. Power Electron. Appl., 2009, pp. 1 10. [11] P.Cairoli, R. Dougal, U. Ghisla, and I. Kondratiev, Power sequencing approach to fault isolation in dc systems: Influence of system parameters, in Proc. IEEE Energy Convers. Congr. Expo. 2010, pp. 72 78. [12] L. Tang and B. Ooi, Locating and isolating DC faults in multi terminal DC systems, IEEE Trans. Power Del., vol. 22, no. 3, pp. 1877 1884, Jul. 2007. [13] R. Schmerda, S. Krstic, E. Wellner, and A. Bendre, IGCTs vs. IGBTs for circuit breakers in advanced ship electrical systems, in Proc. IEEE Electric Ship Technol. Symp., Apr. 2009, pp. 400 405. [14] M. Saisho, T. Ise, and K. Tsuji, Configuration of DC loop type quality control center, in Proc. Power Convers. Conf., 2002, vol. 2, pp. 434 439. [15] Lopamudra Mitra, Solar Powered Synchronous Buck Converter For Low Voltage Applications International Journal of Electrical Engineering & Technology (IJEET), Volume 5, Issue 5, 2014, pp. 74-88, ISSN Print : 0976-6545, ISSN Online: 0976-6553. [16] Ömer Gül, Smart AC/DC Low Voltage Distribution System For Building With Distributed Generation And Electric vehicles International Journal of Electrical Engineering & Technology (IJEET), Volume 5, Issue 9, 2014, pp. 1-16, ISSN Print : 0976-6545, ISSN Online: 0976-6553. [17] Pravin S. Phutane and A.K. Jhala, A Review: Low Voltage Ride through (LVRT) In Wind Farm International Journal of Electrical Engineering & Technology (IJEET), Volume 5, Issue 5, 2014, pp. 36-43, ISSN Print: 0976-6545, ISSN Online: 0976-6553. 247