COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

Similar documents
GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

Liquid-Filled Transformers

CAST RESIN DRY TRANSFORMER

(

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

TMC Transformers TMC

AM SGB Sdn Bhd. Company Profile. Transformer First Class

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

SGB at a glance. One of the leading manufacturers. for transformers worldwide

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

VIRGINIA TRANSFORMER CORP. Drive & Rectifier. Transformersrs

OIL-IMMERSED ARC-SUPPRESSION COILS

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Convincing technology creates compact performance

Transformer Factory Testing

Basic Principles and Operation of Transformer

Technical Performance LS Cast Resin Transformers 50kVA Through 15,000kVA Primary Voltage: 2.3kV Through 36kV Secondary Voltage: 120V Through 24kV

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Discipline Electrical Testing Issue Date Certificate Number T-2837 Valid Until Last Amended on - Page 1 of 6 LOCATION 1

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Introduction. Centrado leading-edge transformer. Introduction

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

siemens.com/transformers Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

nical catalogue Tech

Description. Features and Benefits

Transformer Winding Design. The Design and Performance of Circular Disc, Helical and Layer Windings for Power Transformer Applications

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

The GEAFOL Neo: the optimum foundation for power distribution siemens.com/transformers

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Trasfor 3E Series. Reliable Answers to Your Questions. Made in Switzerland

Climatic, Environmental and Fire Behaviour (C2 E2 F1) Test of Cast Resin Transformer

Electrical Description

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Ritz Instrument Transformers GmbH. Welcome

Federal Power Transformers LLC based in Abu Dhabi, UAE

SECTION 16322B SUBSTATION TRANSFORMERS DRY-TYPE

Cast resin transformers HARMONY TM

ON LOAD TAP CHANGERS RSV 5.3 TECHNICAL DATA

Dry-type Transformer. High Reliability Maintenance-free Environmentally Friendly

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

Electrical Design Process

CONDITIONS FOR A TENTATIVE APROVAL FOR CONNECTION OF TRANSFORMERS

.1 Provide dry type cast-resin 11kV/0.420kV transformers in accordance with the Contract Documents.

Power transformers for Network, Rectifiers, Furnace

Shunt Reactors. Global Top Energy, Machinery & Plant Solution Provider

DESIGNED MANUFACTURED TESTED

Understanding the Value of Electrical Testing for Power Transformers. Charles Sweetser, OMICRON electronics Corp. USA

Compact Substation or Prefabricated Substation Inside Totally Enclosed Weatherproof Enclosure COPYRIGHT REGISTERED

2.4. Transformers. Contents Description General-Purpose Encapsulated Transformers Catalog Number Selection... Product Selection... Product Description

Advanced, accurate and intelligent monitoring for your transformer

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

PUBLIC POWER CORPORATION ENGINEERING & CONSTRUCTION OF TRANSMISSION PROJECTS DEPARTMENT

TRANSFORMER TECHNOLOGY GPT

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

Siemens Transformer Technology Seminar Insulation & Thermal Design

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

Group F : Sl. No. - 1) 33/0.403 KV, 100 KVA Station Transformer GUARANTEED & OTHER TECHNICAL PARTICULARS. Table : A

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

PES & IAS NY Chapter And NY LMAG June 23 rd, 2015

POWER TRANSFORMERS CATALOGUE

POWER TRANSFORMER SPECIFICATION, DESIGN, QUALITY CONTROL AND TESTING 18 MARCH 2009

500 kva Dry-type Isolation Transformer V-Delta to 208Y/120V 3PH - NEMA 1/Indoor

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

MEDIUM & HIGH VOLTAGE

Device Under Test: ALTEA VS- 24-I VS-24-I. 0 24/09/12 First issue A. Peretto L. Peretto 1 24/06/16 All text review E. Scala L. Peretto J. L.

ABB Power Products Service

Liquid Filled Transformers Load Tap Changing Transformers Three-Phase Voltage Regulators

SECTION TRANSFORMERS

ON LOAD TAP CHANGERS RS 6.3 / RS 6 TECHNICAL DATA

Diagnostic testing of cast resin transformers

CITY OF TACOMA Transmission & Distribution

Distribution Transformers

DISTRIBUTION TRANSFORMER 11 / kv

TRANSFORMER OPERATIONAL. Principles, Selection & Troubleshooting

EE059: Transformer Operation, Maintenance, Diagnosis & Testing

Test description for dry-type transformers chapter for special tests

Martin Stoessl R&D Manager Siemens Transformers Austria - Weiz

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

TEST REPORT. Table Of Contents

TRAFO ELECTRIC P. LTD.

Particulate Control O&M Training. APC/PCUG Conference July 12-16, 2009 The Woodlands, TX

Powering Your Business

Hands-On Transformer Testing and Maintenance

3. COMBINED TRANSFORMERS Oil-paper insulation

HOW TO SAFE GUARD THE TRANSFORMER..???

ON LOAD TAP CHANGERS RS 9.3 / RS 9 TECHNICAL DATA

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

GENERAL PURPOSE DRY-TYPE DISTRIBUTION TRANSFORMERS

DISTRIBUTION TRANSFORMERS

Transcription:

CONTENTS COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3 CONSTRUCTION... 4 ~ 5 A. CORE AND FRAME... 4 B. COIL... 5 C. TEMPERATURE INDICATOR... 5 CHARACTERISTICS... 6 MANUFACTURING FACILITIES... 7 TESTING FACILITIES... 7 ~ 9 A. LIGHTNING IMPULSE TEST (BIL)... 8 B. TEMPERATURE RISE TEST... 8 C. MEASUREMENT OF SOUND LEVEL... 9 TECHNICAL DATA...10 ~ 12 A. TC105F1A-N... 10 B. TC205F1A-N... 11 C. TC105F1A-R... 12 GENERAL CONFIGURATION... 13

COMPANY PROFILE UNELECTRA INTERNATIONAL CORP. known as UIC was established by a group of experienced engineers under the direction of Bureau of Industry, Ministry of Economic Affairs, TAIWAN in 1986. In the beginning UIC introduced state-of-the-art technology and equipment to produce Cast Resin Transformers and secured variety of certificates from well-known third authorities, so the product can be sold well, not only domestically but also internationally. UIC HEAD OFFICE Due to UIC has focused on the cast resin technique for years, so its extended cast resin related product-cast Resin Busway was developed and produced since 2000. The Company hopes to upgrade the domestic and global industry level as well as providing safe and reliable electrical distribution products to the customers. QUALITY, SERVICE, CONTRIBUTION Since the establishment of this Company, "QUALITY, SERVICE and CONTRIBUTION" is our highly honored motto. Through the implementation of the management concept contains into this motto. UIC assures to offer the EXCELLENT PRODUCTS, SATISFACTORY SERVICE and OUTSTANDING CONTRIBUTION to the customers as the final target. UIC FACTORY We strive for the best endeavour to provide the gratifying services before and after sales, in-time delivery of our products and reasonable price level. In order to contribute to the society, the company strives to make the products available with high safety, reliability and with full environmental protection sense to our clients as well as community in expectation for the Company to achieve the goal of long lasting operation. UIC has passed KEMA TAIPOWER and XIAN WUHAN PRC HV LAB. etc. type tests to assure its manufacturing capability and also certified as an ISO 9001 quality assured, ISO 14001 EMS firm and OHSAS 18001 health and safety control. We believe we can offer the best products and service in consonance with our motto "QUALITY SERVICE CONTRIBUTION" in operation. www.uic.com.tw 1

QUALITY CERTIFICATES The range of UIC EXICAST transformer is up to 15MVA and 36kV, As per customers specification or international standards, Such as IEC, NEMA, ANSI, BS, DIN, JIS, AS etc... 2 www.uic.com.tw

APPLICATIONS HIGH SPEED RAIL MRT SYSTEM AIRPROT OIL & GAS PLATFORM POWER STATION CONTAINER CRANE SEMICONDUCTOR INDUSTRY OPTRONIC INDUSTRY STEEL INDUSTRY MALL HIGH RISE COMMERCIAL BUILDING HOTEL MILITARY HOSPITAL CAMPUS www.uic.com.tw 3

CONSTRUCTION A. Core and Frame The core is made of the highest quality, low loss, cold-rolled, grain-oriented silicon steel with V notch and step lap to reduce no load loss, no load current and noise level to a minimum. CORE STRUCTURE & MAGNETIC FLUX at SEAM CORE PROPERTY COMPARE TABLE Note: assume the base 1.0 on MITER type. 1.0 0.9 (RELATIVE VALUE) 0.8 0.7 0.6 0.5 0.4 0.3 0.2 0.1 0 NO LOAD LOSS NO LOAD CURRENT V-NOTCH TYPE STEP-LAP AND V-NOTCH TYPE 500 1000 1500 2000 2500 (KVA) 3000 3500 4000 4500 5000 4 www.uic.com.tw

CONSTRUCTION B. Coil LV COIL LV COIL HV COIL HV COIL All EXICAST transformer HV coils are wound on a steel mold and cast in an autoclave under vacuum and controlled the temperature and time with glassfiber reinforced epoxy resin by capillary action in order to avoid voids during the resin impregnation which fully meets the solid cast and epoxy resin encapsulated dry type cast resin transformer requirements. Resin components, which include resin, hardener and flexibilizer are introduced in the degassing tanks before the mixing for degassing in a thin resin liquid forms. Air bubbles which may exist in resin components are totally eliminated by this continuous degassing process. The weight of resin components will be automatically weighed by a synchronizing device in the plant that any improper weighing of the components will be exactly avoided. EXICAST transformer only adopts copper wire conductor for the HV coils; copper wire, foil or aluminum foil based on customer request for the LV coils. Either HV or LV coils the conductor will be insulated with class F material; coils will belong to "self-extinguishing type". The components of resin and insulating materials in coils will be non-toxic when burnt. The coils do not absorb moisture and can be stored at 100% humidity and in temperature down to -40 C while de-energized after which it may immediately be put into full service without need for drying out. C. Temperature Indicator Dial Type Thermometer UIC EXICAST TR. Standard Accessory Contactor: Alarm & Trip Temperature Range: 0 ~ 200 C Sensor: KO-107 Temperature Indicator Power: 110/220V, 50/60Hz Contactor: Alarm & Trip Temperature Range: -100 C ~ 400 C Sensor: PT-100Ω Protocol(option): RS485/4 ~ 20mA Temperature Indicator and Controller Power: 110/220V, 50/60Hz Contactor: AF Control, Alarm & Trip Temperature Range: 1 C~199 C Sensor: PT-100Ω x 3 Protocol(option): RS485/4~20mA www.uic.com.tw 5

CHARACTERISTICS Characteristics Moisture Proof EXICAST TRANSFORMERS is complied with E2 environmental class, so it is suitable to be operated in high humidity, salty or pollution area. And it is capable of being energized directly after a long time storage without drying. Fire Resistant EXICAST TRANSFORMERS is complied with F1 fire behavior requirements. The safe characteristic of self-extinguishing fire resistance and no noxious material during inflammation can be assured. Short Circuit Resistant Due to the strong glass fiber reinforced design, the dynamic short circuit strength of EXICAST TRANSFORMER is superior to the other type transformers. Thermal Shock Resistance EXICAST TRANSFORMERS is complied with C2 climate class, using non-filler technology, even the worst temperature fluctuation will not cause the cracking of the coils. High BIL Withstand Level EXICAST TRANSFORMERS have impulse levels equal to liquid-immersed transformers. The high BIL withstand can meet international standards or customers' specification. Low Noise Level Design EXICAST TRANSFORMERS design as per V notch and step lap core construction, the noise level can be reduced, and meet the international standards or some special low noise level requirements. High Overload Capability EXICAST TRANSFORMERS has high thermal time constant of the coils, so it can withstand sudden momentary high overloads better than other type transformers. Low Partial Discharge EXICAST TRANSFORMER is a long life service product. The coils are cast under the vacuum processing to avoid air bubbles and no voids. Each HV coils is tested for partial discharge before and after the assembly for assuring a void-free transformers. Ambient temp. 40 C Maintenance Free Due to the completely sealed windings have antimoisture property and no oil, it is almost maintenance free during normal operation. Ambient temp. 20 C 6 www.uic.com.tw

MANUFACTURING FACILITIES CORE CUTTING MACHINE CORE STACKING SET HV WINDING MACHINE LV WINDING MACHINE MOLDS VACUUM CASTING TANK TESTING FACILITIES PURPOSE Each UIC EXICAST transformers must pass factory tests before shipping. The testing procedure is based on ISO 9001, in order to assure that the transformers supplied to the customer will comply with the customer specification and related international standards requirements. TEST STANDARDS Following IEC 60076-11 or other standards if specifically specified by the customer. TEST ITEMS Factory tests Measurement of winding resistance Measurement of voltage ratio Check of phase displacement Measurement of no-load loss and exciting current Measurement of short-circuit impedance and load loss Separate-source AC withstand voltage test Induced AC withstand voltage test Partial discharge Measurements µω METER TTR DIGITAL POWER METER AC VOLTAGE WITHSTAND TEST EQUIP. Type and special tests (OPTION) Lightning Impulse test (BIL) Temperature rise test Measurement of sound level INDUCE VOLTAGE TEST SET P. D. EQUIPMENT www.uic.com.tw 7

TESTING FACILITY A. LIGHTNING IMPULSE TEST (BIL) U 1.0 T1 =1.2µs±30% T2 =50µs±20% 0.5 0 01 T1 T2 INSULATION LEVELS BASED ON EUROPEAN PRACTICE Highest voltage Rated short duration Rated lightning impulse withstand separate source voltage (peak value) kv for equipment Um AC withstand (r.m.s.) kv List 1 List 2 (UIC EXICAST) voltage (r.m.s.) kv 1.1 3 3.6 10 20 40 7.2 20 40 60 12 28 60 75 17.5 38 75 95 24 50 95 125 36 70 145 170 B. TEMPERATURE RISE TEST INSULATION SYSTEM TEMPERAURE ( C) WINDING TEMERATURE RISE LIMITS AVERAGE WINDING TEMPERATURE RISE LIMITS AT RATED CURRENT (K) 105 (A) 60 120 (E) 75 130 (B) 80 155 (F) 100 180 (H) 125 200 135 220 150 TEMPERATURE RISE CURVE 8 www.uic.com.tw

TESTING FACILITY C. MEASUREMENT OF SOUND LEVEL MEASUREMENT POINTS SOUND SPECTRUM ANALYSIS 7 2N 6 5 2U 2V 2W 8 4 1U 1V 1W 1 2 3 TESTING CHAMBER www.uic.com.tw 9

TECHNICAL DATA A. TC105F1A-N 3Ø, 50Hz, Um 12kV, HV BIL 75kV, P.F. 28kV, LV P.F. 3kV, Temperature rise 100K 10 www.uic.com.tw

TECHNICAL DATA B. TC205F1A-N 3Ø, 50Hz, Um 24kV, HV BIL 125kV, P.F. 50kV, LV P.F. 3kV, Temperature rise 100K www.uic.com.tw 11

TECHNICAL DATA C. TC105F1A-R 3Ø, 50Hz, Um 12kV, HV BIL 75kV, P.F. 28kV, LV P.F. 3kV, Temperature rise 100K (High efficiency) 12 www.uic.com.tw

GENERAL CONFIGURATION 1. LV Terminals 2. Lifting Lugs 3. Core Yoke 4. HV Coil 5. LV Coil Termination 6. Core Bandage 7. LV Coil 8. Towing Holes 9. Frame Bolts 10. Anti-Vibration Pad 11. Clamp Bolt Insulation 12. Clamp Bolts 13. HV Insulators 14. Upper Frame 15. Core Clamp Adjuster 16. Coil Support Block 17. Resilient Pad 18. Core Leg 19. Tie Bars 20. HV Coil Terminal 21. HV Tapping 22. Tapping Link 23. Tapping Cover 24. Lower Frame 25. Cooling Fan 26. Fan Supporters 27. Cooling Fan Set www.uic.com.tw 13