Nondestructive Testing (CALIBRATION)

Similar documents
S. GURESH 4 JAN 2017 S. JOHNSON 4 JAN 2017

Engineering Policy & Procedure

RADIOGRAPHIC EXAMINATION PROCEDURE

Welding Inspection Non-Destructive Testing Course Reference WIS 5

NDT-PRO Services expands service offering

The Application of TOFD Technique on the Large Pressure Vessel

New Multi-Technology In-Line Inspection Tool For The Quantitative Wall Thickness Measurement Of Gas Pipelines

Introduction To NDT. BY: Omid HEIDARY

Heat Exchanger & Boiler Tube Inspection Techniques

RELIABILITY OF GUIDED WAVE ULTRASONIC TESTING. Dr. Mark EVANS and Dr. Thomas VOGT Guided Ultrasonics Ltd. Nottingham, UK

GUIDELINES FOR THE APPLICATION OF TIME-OF-FLIGHT DIFFRACTION (TOFD) AND PHASED ARRAY ULTRASONIC TESTING (PAUT) TECHNIQUES

NONDESTRUCTIVE EVALUATION OF CLOSED CRACKS USING AN ULTRASONIC TRANSIT TIMING METHOD J. Takatsubo 1, H. Tsuda 1, B. Wang 1

Eddy current flaw detector «Eddycon C»

PROPOSED CHANGES TO: APPENDIX IV - PHASED ARRAY E-SCAN AND S-SCAN MANUAL RASTER EXAMINATION TECHNIQUES

JOHANN CATTY CETIM, 52 Avenue Félix Louat, Senlis Cedex, France. What is the effect of operating conditions on the result of the testing?

Standard Practice for Measuring Thickness by Manual Ultrasonic Pulse-Echo Contact Method 1

ISO INTERNATIONAL STANDARD. Non-destructive testing Acoustic emission inspection Secondary calibration of acoustic emission sensors

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing Part 1: X- and gamma-ray techniques with film

Standard Practice for Ultrasonic Examination of Turbine and Generator Steel Rotor Forgings 1

Annexure - V. Specifications, Typical Drawing & Data Sheet for Split TEE (Hot Tapping Material)

ISO INTERNATIONAL STANDARD. Non-destructive testing of welds Radiographic testing of fusionwelded

ClampOn, Inc. Ultrasonic Intelligent Sensors. Presented by Hans A. Wagner

GB/T Translated English of Chinese Standard: GB//T NATIONAL STANDARD OF THE

Application of Ultrasonic Guided Wave to Heat Exchanger Tubes Inspection

American Institute of Timber Construction 7012 South Revere Parkway Suite 140 Centennial, CO Phone: 303/ Fax: 303/

NUCLEAR POWER CORPORATION OF INDIA LIMITED (A Govt. of India Enterprise)

Weld Seam Inspection of Thick Wall Austenitic Steel Tubes beyond Standard Eddy Current Technology

Gamex Lite 3.0 Program description and operating manual

SonaFlex. Set of Portable Multifunctional Equipment for Non-contact Ultrasonic Examination of Materials

Measurement and Inspection and Testing

ASME BPVC.V-2015 SECTION V ASME Boiler and Pressure Vessel Code An International Code. N on de st ruct iv e Exa min a t ion

American Petroleum Institute Task Group Line Pipe

The Probe KK&S INSTRUMENTS - April / June 2013

RECENT ADVANCEMENTS IN THE APPLICATION OF EMATS TO NDE

ISO 2808 INTERNATIONAL STANDARD. Paints and varnishes Determination of film thickness. Peintures et vernis Détermination de l'épaisseur du feuil

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic inspection Evaluating electronic characteristics of ultrasonic test instruments

Swivel Hoist Ring Page 142

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

An instrument for detecting corrosion in anchorage zones of bridge cables using guided waves

FLOW SWITCH 600 Series Velocity Flow Sensor. Instruction Manual

Part 1: General principles

NON DESTRUCTIVE TESTING 2 MARK QUESTION & ANSWERS UNIT I

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

INTRODUCTION. Strong Performance: High resolution and penetration, achieving precise flaw detection

Swivel Hoist Ring RIGGING ACCESSORIES. Color coded to distinguish between UNC (Red) and Metric (Silver) thread types.

18th World Conference on Non-destructive Testing, April 2012, Durban, South Africa

This British Standard, having been prepared under the direction of the Iron and Steel Standards Policy Committee, was published under the authority of

In-Line EMAT Ultrasonic Weld Inspection for ERW Tube Mill Using Guided Ultrasonic Waves

A SIMPLE METHOD TO COMPARE THE SENSITIVITY OF DIFFERENT AE SENSORS FOR TANK FLOOR TESTING

Ultrasonic Level Transducer Type: MPUL06 Article No.: ca. 122

Model: PR-55. High Voltage Oscilloscope Probe 10 kv, 40 MHz USER MANUAL

Module 4 Design for Assembly IIT BOMBAY

Acoustic emission signal attenuation in the waveguides used in underwater AE testing.

VHF LAND MOBILE SERVICE

SECTION STRUCTURAL STEEL. A. PART A and DIVISION 1 of PART B are hereby made a part of this SECTION.

NB/T Translated English of Chinese Standard: NB/T

In service application of EMAT in Boiler Water Wall Tubes and High Temperature Components

Fretting Fatigue of Slot-dovetails in Turbo-generator Rotor

The Implementation of the New Standard EN ISO for Ultrasonic Phased-Array Systems at the Manufacturer

Government Recognized Export House OHSAS 18001:2007 ISO 14001:2004 PED Approved Company.

Effect of coupling conditions on ultrasonic echo parameters

EMAT Application on Incoloy furnace Tubing Ramamohan Reddy M (ASNT Level III UT, PCN Level III UT,PAUT&TOFD)

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Test Specification for Type Approval

ACOUSTIC EMISSION MEASUREMENTS ON SHELL STRUCTURES WITH DIRECTLY ATTACHED PIEZO-CERAMIC

INVESTIGATION OF IMPACT DAMAGE OF CARBON FIBER- RAINFORCED PLASTIC (CFRP) BY EDDY CURRENT NON- DESTRUCTIVE TESTING

Recommendation of RILEM TC 212-ACD: acoustic emission and related NDE techniques for crack detection and damage evaluation in concrete*

OPTIFLUX 5000 Technical Datasheet

Standard Practice for Ultrasonic Examinations Using Electromagnetic Acoustic Transducer (EMAT) Techniques 1

VT4887. Compact Bi-Amplified Three-Way High Directivity. Line Array Element. Application: Specifications: VERTEC TM Series

A PHASED ARRAY ULTRASONIC TESTING OF A MANUAL THICK AUSTENITIC WELD FEEDBACK

Ultrasonic Level Detection Technology. ultra-wave

VD3-71 universal eddy current flaw detector application for field inspection of aeronautical engineering

Reference Standards Calibration Blocks

D DAVID PUBLISHING. Eddy Current Test for Detection of Foreign Material using Rotating Probe. 2. Theory. 1. Introduction

Novel Imaging Techniques for Defects Characterisation in Phased Array Inspection

ISHR-M111 MAGNETIC ROCKWELL HARDNESS TESTER OPERATION MANUAL

Developments in Ultrasonic Guided Wave Inspection

1112. Dimensional evaluation of metal discontinuities by geometrical parameters of their patterns on imaging flaw detector monitor

Corrosion detection under pipe supports using EMAT Medium Range Guided Waves

PROBE CATALOG FOR NONDESTRUCTIVE MATERIAL TESTING WITH ULTRASOUND

DEVELOPMENT OF MEASUREMENT SYSTEM USING OPTICAL FIBER AE SENSORS FOR ACTUAL PIPING

THE ANALYSIS OF ADHESIVE BONDS USING ELECfROMAGNETIC

MIL-STD-883H METHOD ULTRASONIC INSPECTION OF DIE ATTACH

R SERIES Premium Music R.5-96MAX HIGH OUTPUT FULL-RANGE 90 x 60 WEATHER-RESISTANT LOUDSPEAKER

Standard Test Method for Radiographic Examination of Metallic Castings 1

AN EMAT ARRAY FOR THE RAPID INSPECTION OF LARGE STRUCTURES USING GUIDED WAVES. Paul Wilcox 1, Mike Lowe 2

Module-4 Lecture-2 Perpendicularity measurement. (Refer Slide Time: 00:13)

Sonic Distance Sensors

NDT KONFERANSEN ZENOVIEA VOROSCIUC

2 Beck, K. H., Limitations to the Use of Reference Blocks for Periodic and. *A Summary of Changes section appears at the end of this standard.

OPTIFLUX 5000 Technical Datasheet

Principles and Applications of Air-Coupled Ultrasonics. Joe Buckley, Sonatest Plc

Installation Instructions TMW Antenna Tower Mount for 4ft (1.2m) Antennas.

Research and Application of Pulsed Eddy Current Testing for Ferromagnetic Metallic Components

Detecting Stress Corrosion Cracking with Eddy Current Array Technology Cracking

Phased Array&TOFD Probes

LST400 Ultrasonic level / open channel flow transmitter

S-band Magnetron. Tuner revolutions to cover frequency range 4.75 (note 3) Mounting position (note 4) Any Cooling (note 5) Water

Time Reversal FEM Modelling in Thin Aluminium Plates for Defects Detection

Transcription:

NONDESTRUCTIVE TESTING (CALIBRATION) HPI Nondestructive Testing (CALIBRATION) Hybrid Petroleum institute His allies at all times Calibration of Nondestructive Testing Devices (PND's) INTRODUCTION Nondestructive test is called to any test carried a material that does not permanently alter the physical, chemical, mechanical or dimensional properties. Nondestructive testing involving negligible or no damage. Different methods of nondestructive testing are based on the application of physical phenomena such as electromagnetic waves, acoustic, elastic, emission of subatomic particles, capillary absorption and any evidence that does not involve considerable damage to the sample examined. The non-destructive testing or NDT are today a large area of research and likewise are a great tool for the industry. This area is intended to support the industry by performing conventional tests (visual inspection, liquid penetrant, ultrasonic, magnetic particles) and unconventional (digital radiography, guided waves, acoustic emission, thermography, etc.) in materials of all kinds. Among the objectives of these tests is to determine the properties and health of a component or equipment, perform materials characterization, support studies of Failure Analysis and Mechanical Integrity. One of the fundamental requirements to perform all the PND's is having calibrated the instruments and devices that are required so that they can make, so in this paper is carried out a review of the requirements for calibration standards grounded in ASME Sec V. The review was conducted to test: Penetrant Test Magnetic Test Ultrasound Test Acoustic Emission Test Radiography Test PENETRANT TEST Aluminum block to sensibility A liquid penetrant comparator block shall be made as follows. The liquid penetrant comparator blocks shall be made of aluminum, ASTM B 209, Type 2024, 3 8 in. (9.5 mm) thick, and should have approximate face dimensions of 2 in. x 3 in. (50 mm x 75 mm). At the center of each face, an area approximately 1 in. (25 mm) in diameter shall be marked with a 950 F (510 C) temperature-indicating crayon or paint. The marked area shall be heated with a blowtorch, a Bunsen burner, or similar device to a temperature between 950 F (510 C) and 975 F (524 C). Industrial ultrasound angle beam test.

NONDESTRUCTIVE TESTING (CALIBRATION) 2 Penetrant test The specimen shall then be immediately quenched in cold water, which produces a network of fine cracks on each face. The block shall then be dried by heating to approximately 300 F (149 C). After cooling, the block shall be cut in half. One-half of the specimen shall be designated block A and the other block B for identification in subsequent processing. Figure III-630 illustrates the comparator blocks A and B. As an alternate to cutting the block in half to make blocks A and B, separate blocks 2 in. x 3 in. (50 mm x 75 mm) can be made using the heating and quenching technique as described above. Two comparator blocks with closely matched crack patterns may be used. The blocks shall be marked A and B. TEMPERATURE LESS THAN 40 F (5 C). If it is desired to qualify a liquid penetrant examination procedure at a temperature of less than 40 F (5 C), the proposed procedure shall be applied to block B after the block and all materials have been cooled and held at the proposed examination temperature until the comparison is completed. A standard procedure which has previously been demonstrated as suitable for use shall be Figure 1 applied to block A in the 40 F to 125 F (5 C to 52 C) temperature range. The indications of cracks shall be compared between blocks A and B. If the indications obtained under the proposed conditions on block B are essentially the same as obtained on block A during examination at40 Fto 125 F (5 C to 52 C), the proposed procedure shall be considered qualified for use. A procedure qualified at a temperature lower than 40 F (5 C) shall be qualified from that temperature to 40 F (5 C). MAGNETIC TEST MAGNETIZING EQUIPMENT Frequency: Magnetizing equipment with an ammeter shall be calibrated at least once a year, or whenever the equipment has been subjected to major electric repair, periodic overhaul, or damage. If equipment has not been in use for a year or more, calibration shall be done prior to first use. LIFTING POWER OF YOKES Prior to use, the magnetizing power of electromagnetic yokes shall have been checked within the past year. The magnetizing power of permanent magnetic yokes shall be checked daily prior to use. The magnetizing power of all yokes shall be checked whenever the yoke has

NONDESTRUCTIVE TESTING (CALIBRATION) 3 been damaged or repaired. Each alternating current electromagnetic yoke shall have a lifting power of at least 10 lb (4.5 kg) at the maximum pole spacing that will be used. Each direct current or permanent magnetic yoke shall have a lifting power of at least 40 lb (18 kg) at the maximum pole spacing that will be used. Each weight shall be weighed with a scale from a reputable manufacturer and stenciled with the applicable nominal weight prior to first use. A weight need only be verified again if damaged in a manner that could have caused potential loss of material. Figure 2 GAUSSMETERS Hall-Effect probe gaussmeters used to verify magnetizing field strength in accordance with T-754 shall be calibrated at least once a year or whenever the equipment has been subjected to a major repair, periodic overhaul, or damage. If equipment has not been in use for a year or more, calibration shall be done prior to first use. PIE-SHAPED MAGNETIC PARTICLE FIELD INDICATOR The indicator shall be positioned on the surface to be examined, such that the copper-plated side is away from the inspected surface. A suitable field strength is indicated when a clearly defined line (or lines) of magnetic particles form(s) across the copper face of the indicator when the magnetic particles are applied simultaneously with the magnetizing force. When a clearly defined line of particles is not formed, the magnetizing technique shall be changed as needed. Pie- type indicators are best used with dry particle procedures. THE KETOS RING (T-766) The Ketos (Betz) ring specimen (see Figure. 3) shall be used in evaluating and comparing the overall performance and sensitivity of both dry and wet, fluorescent and no fluorescent magnetic particle techniques using a central conductor magnetization technique. (a) Ketos (Betz) Test Ring Material. The tool steel (Ketos) ring should be machined from AISI 01 material in accordance with Figure. 3 Either the machined ring or the steel blank should be annealed at 1650 F (900 C), cooled 50 F (28 C) per hour to 1000 F (540 C) and then air cooled to ambient temperature to give comparable results using similar rings that have had the same treatment. Material and heat treatment are important variables. Experience indicates controlling the softness of the ring by hardness (90 to 95 HRB) alone is insufficient. The conductor should have a length greater than 16 in. (400 mm). NOTE: The circular shims shown in Figure. 2 illustration (b) also have flaw depths less and greater than 30%. (b) Using the Test Ring. The test ring (see Figure. 3), is circularly magnetized with fullwave rectified AC passing through a central conductor with a 1 in. to 11 4 in. (25 mm to 32 mm) diameter hole located in the ring center.

NONDESTRUCTIVE TESTING (CALIBRATION) 4 Figure 3 The currents used shall be 1400, 2500, and 3400 amps. The minimum number of holes shown shall be three, five, and six, respectively. The ring edge should be examined with either black light or visible light, depending on the type of particles involved. This test shall be run at the three amperages if the unit will be used at these or higher amperages. The amperage values stated shall not be exceeded in the test. If the test does not reveal the required number of holes, the equipment shall be taken out of service and the cause of the loss of sensitivity determined and corrected. This test shall be run at least once per week. LINEARITY VERTICAL ULTRASOUND INSTRUMENT LINEARITY CHECKS The requirements of T-461.1 and T-461.2 shall be met at intervals not to exceed three months for analog type instruments and one year for digital type instruments, or prior to first use thereafter. CALIBRATION CONFIRMATION ASME System Changes. When any part of the examination system is changed, a calibration check shall be made on the basic calibration block to verify that distance range points and sensitivity setting(s) satisfy the requirements of T-466.3. Calibration Checks. A calibration check on at least one of the reflectors in the basic calibration block or a check using a simulator shall be performed at the completion of each examination or series of similar examinations, and when examination personnel (except for automated equipment) are changed. The distance range and sensitivity values recorded shall satisfy the requirements T-466.3. SENSITIVITY CALIBRATION AWS Technique The sensitivity calibration and horizontal sweep (distance) should be made by the operator of the ultrasonic inspection just before and at the location where each weld tested is located. The re-calibration should be performed after a change of operator, every 30 minutes maximum

NONDESTRUCTIVE TESTING (CALIBRATION) 5 accurately measured in the range of thicknesses to be measured. It is generally desirable that the thickness are "round numbers" instead of various odd values. A block should have a thickness value near the maximum of the range of interest and the other block near the minimum thickness. ACOUSTIC EMISSION time interval, or when the circuit suffers any disturbance in any of the following ways: (1) Switching Transducer (2) Changing the battery (3) Change of power supply (4) Change of coaxial cable (5) Power supply (failure) CURVE DAC ASME Distance Range Points. If any DAC point has moved on the sweep line by more than 10% of the distance reading or 5% of full sweep, whichever is greater, correct the distance range calibration and note the correction in the examination record. All recorded indications since the last valid calibration or calibration check shall be reexamined and their values shall be changed on the data sheets or re-recorded. DISTANCE CALIBRATION AWS Technique The sensitivity calibration and horizontal sweep (distance) should be made by the operator of the ultrasonic inspection just before and at the location where each weld tested is located. The re-calibration should be performed after a change of operator, every 30 minutes maximum time interval, or when the circuit suffers any disturbance in any of the following ways: (1) Switching Transducer (2) Changing the battery (3) Change of power supply (4) Change of coaxial cable (5) Power supply (failure) QUALIFICATION OF THE EQUIPMENT AWS LINEARITY HORIZONTAL. The horizontal linearity of the survey instrument should be re-qualified after every 40 hours of use of the instrument in each of the distance ranges where the instrument will be used. The qualification procedure shall be in accordance with 6.30.1 (See Appendix H for the alternative method). CONTROL GAIN The instrument gain control (attenuator), must meet the requirements of 6.22.4 and should be checked for proper calibration every two months in accordance with 6.30.2. Alternative methods for qualifying calibrated gain control (attenuator), if you provide at least the equivalent to 6.30.2 may be used. INTERNAL REFLECTIONS The maximum internal reflections of each transducer must be verified at time intervals of maximum 40 hours of use of the instrument in accordance with 6.30.3. CALIBRATION ANGLE BEAM TRANSDUCERS Using an approved calibration block every angle beam transducer should be checked after every 8 hours of use, to determine that the contact surface is flat, that is correct the entry point of the sound and the beam angle is within the allowable tolerance of ± 2, in accordance with 6.29.2.1 and 6.29.2.2. The transducer that do not meet these requirements must be corrected or replaced. GAUGE LADDER 4 AND 5 STEPS STANDARD PROCEDURE FOR MEASURING THICKNESS BY THE METHOD MANUAL PULSE ULTRASONIC CONTACT METHOD One or more reference blocks are required, knowledge of the speed of the material to be examined, and having thicknesses and EXAMINATION OF METALLIC VESSELS DURING PRESSURE TESTING All relevant indications caused by AE sources shall be evaluated by other methods of nondestructive examination. External noise sources such as rain, foreign objects contacting the vessel, and pressurizing equipment noise must be below the system examination threshold. Sensor Frequency. Selection of sensor frequency shall be based on consideration of background noise, acoustic attenuation, and vessel configuration. Frequencies in the range of 100 khz 400 khz have been shown to be effective. When examining austenitic stainless steels, titanium, or nickel alloys, the need to restrict chloride/fluoride ion con- tent, total chlorine/fluorine content, and sulfur content in the couplant or other materials used on the vessel surface shall be considered and limits agreed upon between contracting parties. The sensor shall be held in place utilizing methods of attachment, as specified in the written procedure. The signal cable and preamplifier shall be supported such that the sensor does not move during testing. Surface Contact. Sensors shall be mounted directly on the vessel surface, or on integral waveguides. Sources shall be located to the specified accuracy by multichannel source location, zone location, or both, as required by the referencing Code Section. All hits detected by the instrument shall be recorded and used for evaluation. PRE-EXAMINATION MEASUREMENTS On-Site System Calibration. Prior to each vessel test or series of tests, the performance of each utilized channel of the AE instrument shall be checked by inserting a simulated AE signal at each main amplifier input. A series of tests is that group of tests using the same examination system which is conducted at the same site within a period not exceeding 8 hr. or the test duration, whichever is greater. This device shall input a sinusoidal burst-type signal of measurable amplitude, duration, and carrier frequency. As a minimum, on-site system calibration shall be able to verify system operation for threshold, counts, duration, rise time, MARSE (signal strength or energy), and peak amplitude.

NONDESTRUCTIVE TESTING (CALIBRATION) 6 INSTRUMENT CALIBRATION AND CROSS- REFERENCING MANUFACTURER S CALIBRATION Acoustic emission system components will be provided from the Manufacturer with certification of performance specifications and tolerances. ANNUAL CALIBRATION The instrument shall have an annual comprehensive calibration following the guidelines provided by the Manufacturer using calibration instrumentation meeting the requirements of a recognized national standard. INSTRUMENT The performance and threshold definitions vary for different types of AE instrumentation. Parameters such as counts, amplitude, energy, etc., vary from Manufacturer to Manufacturer and from model to model by the same Manufacturer. This section of appendix describes techniques for generating common baseline levels for the different types of instrumentation. The procedures are intended for baseline instrument calibration at 60 F to 80 F (16 C to 27 C). For field use, small portable signal generators and calibration transducers can be carried with the equipment and used for periodic checking of sensor, preamplifier, and channel sensitivity. use, or after change of apertures, whichever comes first. (b) Step Wedge Comparison Films. Verification checks shall be performed annually per T-262.2. TERMOMETROS Follow the temperature recommendations from the film or solution manufacturer and check thermometers. Check thermometers and temperature-controlling devices periodically to be sure that the process temperatures are correct. Figure 4 SENSOR CHARACTERIZATION Threshold of acoustic emission detectability is an amplitude value. All sensors shall be furnished with documented performance data. Such data shall be traceable to NBS standards. A technique for measuring threshold of detect- ability is described in Article XI, Appendix II. THRESHOLD Threshold of acoustic emission detectability shall be determined using a 4 ft x 6 ft x 1 2 in. (1.2 m x 1.8 m x 13 mm) 99% pure lead sheet. The sheet shall be sus- pended clear of the floor. The threshold of detectability is defined as the average measured amplitude of ten events generated by 0.3 mm pencil (2H) lead break at a distance of 4 ft 3 in. (1.3 m) from the sensor. A break shall be done at an angle of approximately 30 deg to the test surface with a 0.1 in. (2.5 mm) lead extension. The sensor shall be mounted 6 in. (150 mm) from the 4 ft (1.2 m) side and middistance between the 6 ft (1.8 m) sides. RADIOGRAPHIC TEST DENSITOMETERS (a) Periodic calibration verification checks shall be performed as described in T-262.1 at the beginning of each shift, after 8 hr. of continuous

NONDESTRUCTIVE TESTING (CALIBRATION) 7 Process temperatures should be checked at least once per shift. Keep the temperature of the stop (if used), fixer, and wash water within ±5 F (±3 C) of the developer temperature. WARNING: An unprotected mercury filled thermometer should never be used for radiographic film processing applications because accidental breakage could result in serious mercury contamination. Thermometers do not require calibration, but if you notice that this appliance is damaged or has a doubt of its performance it is recommended to replace it with a new one, such recommendation should have a secondary thermometer if you have any doubt about the operation of first thermometer. Nondestructive Testing (CALIBRATION) AJUSCO No15, Col Portales [C.P.03300, México, D.F.] Copyright 2010, Hybrid Petroleum Derechos Reservados.