CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

Similar documents
MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

CONTENTS MS2033A. 1.Introduction Safety Information...01

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

400Amp True RMS AC Clamp Meter + NCV

EX350 Series USER GUIDE. True RMS Digital Multimeters. EX350 True RMS Digital Multimeter EX355 True RMS Digital Multimeter with Temperature

400Amp True RMS AC/DC Clamp Meter Model EX613

DM-45 Digital Multimeter

USER'S MANUAL DMR-6700

USER MANUAL. Model MA A AC Clamp Meter DMM Model MA445 True RMS 400A AC/DC Clamp Meter DMM

200Amp AC Clamp Meter + NCV Model MA250

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

MODEL: D03128 CLAMP METER

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

600A Clamp Meters w/tightsight Display

User s Guide. 400A AC/DC Clamp Meter. Model MA220

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DCM730. Digital Clamp Meter User s Manual

MS2030 CAT III 600 V A V AUTO RS232

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

Electrical Multimeter

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

User's Guide Extech EX Amp Clamp Meter with IR Thermometer

USER S MANUAL DMR-1500

R/C SMD Tweezers Multimeter Model RC200

User Manual. All rights reserved. Specifications are subject to change without notice.

AC/DC CLAMP METER USER S MANUAL

User's Guide Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Digital Clamp Meter Model: &

EX360 Series USER MANUAL. True RMS Digital Multimeters. EX360 True RMS Digital Multimeter EX363 True RMS DMM with Temperature and µa AC/DC

USER MANUAL. Mini Multimeter with Non-Contact Voltage Detector (NCV) Model EX330

Model ST Instruction Manual. True RMS Autoranging Digital Multimeter. reedinstruments. www. com

MS2109A AC/DC Clamp Meter. User Manual. Contents

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User Manual. All rights reserved. Specifications are subject to change without notice.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

312, 316, 318. Clamp Meter. Users Manual

Not for Reproduction

Compact MultiMeters + Voltage Detector

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

True RMS Digital Multimeter Model:

DVM1190 DIGITAL MULTIMETER

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

DDM350 Pen-Type Digital Multimeter User s Manual

400Amp True RMS AC/DC Clamp Meter with IR Thermometer Model EX623

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MS8250A/B OPERATION MANUAL MS8250A. Hz% FUNC REL RANGE REL HOLD OFF 10A. Hz% A NCV. Hz% COM. A ma 10A FUSED 600V CAT IV.

User Manual Digital Multimeter. model no.: MSR-U1000

USER'S MANUAL DMR-4350

AC750 DIGITAL CLAMP METER

OPERATING INSTRUCTION

User's Guide. Extech 800 Series 1000 Amp Clamp Meters with IR Thermometer

UT207A/208A/209A Operating Manual. Table of Contents

Autoranging Multimeter Extech EX503

DIGITAL MULTIMETER CONTENTS DIGITAL MULTIMETER CONTENTS

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

Model: &

Multifunction Digital

ET-3888 True RMS Clamp Meter. User Manual

OPERATOR S INSTRUCTION MANUAL M-2625 AUTO RANGING DIGITAL MULTIMETER

ETHOS 5030 TRUE-RMS DIGITAL MULTIMETER OPERATION MANUAL

DIGITAL CLAMP METER Use s Manual

Analog Technologies. Multimeter 115C and 117C

Mini Clamp Meter Model:

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

DIGITAL MULTIMETER OPERATOR'S INSTRUCTION MANUAL HOLD 10A COM LIGHT MS8265 ON/OFF. 200M KHz 2K 20K μ μ μ n.

AC Clamp Meter + Phase Rotation Tester

INSTRUCTION MANUAL. Model Autoranging DMM ProbeMeter TM. Measures voltage, resistance, frequency, capacitance, temperature, and duty cycle.

DM-46 Instruction Manual

MS8250D DUAL DISPLAY DIGITAL MULTIMETER User s Manual

User s Guide. Digital AC/DC Clamp Meter Model 38394

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

114, 115, and 117. True-rms Multimeters. Users Manual

Model 77 Series IV. Digital Multimeter. Users Manual

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

Electrical Multimeter

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

OPERATOR S INSTRUCTION MANUAL

Digital Multimeter, Pen Type

Operating Instructions 22070T True RMS AC/DC CLAMP METER Instrucciones de uso. Pinza amperimétrica de CA/CC de RMS verdadera

User Guide. Digital AC/DC Clamp Meter Model 38394

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

79/26 Series III Multimeter

NOTE: Fully read and understand this manual before using this Digital Multimeter.

1.General instructions Specifications Description...7

AMM-1022 Digital Multimeter USER`S MANUAL

Handheld Digital Multimeter PRO-50A

DM-46 Instruction Manual

ProfiScale MULTI Multimeter

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

USER'S MANUAL DMR-4300

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

Dawson DDM190. Digital Multimeter User s Manual

Transcription:

ENGLISH INSTRUCTION MANUAL 2000A Digital Clamp Meter True RMS Measurement Technology NON-CONTACT VOLTAGE TESTING INRUSH CURRENT LOW IMPEDANCE DATA HOLD RANGE HOLD AUDIBLE CONTINUITY DIODE TEST CAPACITANCE FREQUENCY 1000V 2000A 60MΩ CL900

99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com GENERAL SPECIFICATIONS Klein Tools CL900 is an auto-ranging, true root mean square (TRMS) digital clamp meter that measures AC/DC current via the clamp and measures AC/DC voltage, resistance, continuity, frequency, dutycycle, capacitance, and tests diodes via test-leads. It features a Low Impedance (LoZ) mode for identifying and eliminating ghost or stray voltages, and has a dedicated mode for capturing Inrush Current. Operating Altitude: 6562 ft. (2000m) Relative Humidity: <80% non-condensing Operating Temperature: 32 to 122 F (0 to 50 C) Storage Temperature: 14 to 140 F (-10 to 60 C) Accuracy: Values stated at 65 to 83 F (18 to 28 C) Temp Coefficient: 0.1 x (Quoted Accuracy) per C above 28 C or below 18 C, corrections are required when ambient working temp is outside of Accuracy Temp range Dimensions: 10.4" x 3.9" x 1.7" (265 x 99 x 43 mm) Weight: 18.6 oz. (526 g) including batteries Calibration: Accurate for one year Standards: Conforms to UL STD 61010-1, 61010-2-032, 61010-2-033. Certified to CSA STD C22.2 # 61010-1, 61010-2-032, 61010-2-033. IEC EN 61010-1, 61010-2-032, Pollution degree: 2 61010-2-033. Accuracy: ± (% of reading + # of least significant digits) Drop Protection: 6.6 ft. (2m) Safety Rating: CAT IV 600V, CAT III 1000V, Class 2, Double insulation CAT III: Measurement category III is applicable to test and measuring circuits connected to the distribution part of the building s low-voltage MAINS installation. CAT IV: Measurement category IV is applicable to test and measuring circuits connected at the source of the building s low-voltage MAINS installation. Electromagnetic Environment: IEC EN 61326-1. This equipment meets requirements for use in basic and controlled electromagnetic environments like residential properties, business premises, and light-industrial locations. 2Specifications subject to change.

ELECTRICAL SPECIFICATIONS Function Range Resolution Accuracy (50/60 Hz) AC Voltage (V AC) DC Voltage (V DC) 600.0mV 0.1mV ±(1.0% + 8 digits)* 6.000V 1mV ±(1.0% + 5 digits) 60.00V 10mV 600.0V 0.1V ±(1.2% + 5 digits) 1000V 1V ±(1.5% + 5 digits) 600.0mV 0.1mV ±(0.9% + 8 digits) 6.000V 1mV 60.00V 10mV ±(1.0% + 3 digits) 600.0V 0.1V 1000V 1V ±(1.2% + 3 digits) Input Impedance: 10MΩ Frequency Range: 50 to 400Hz Maximum Input: 1000V AC RMS or 1000V DC *Accuracy specified from 5% to 100% of the measuring range AC Current 600.0A 0.1A ±(2.0% + 5 digits) (A) TRMS 2000A 1A ±(2.5% + 8 digits) DC Current (A) 600.0A 0.1A ±(2.0% + 5 digits) 2000A 1A ±(2.5% + 8 digits) AC Frequency Range: 50 to 60Hz, >500mA DC: >200mA (low current requires use of DC ZERO function) AC Current (A) Inrush 600A 0.1A ±(2.5% + 5 digits)** 2000A 1A ±(3.0% + 8 digits)** AC Frequency Range: 50 to 60Hz when auto-ranging >3A detectable (>2A if held in 600A range) **Accuracy specified assumes AC sine wave 600.0Ω 0.1Ω 6.000KΩ 1Ω Resistance 60.00kΩ 10Ω ±(1.5% + 5 digits) 600.0kΩ 100Ω 6.000MΩ 1kΩ 60.00MΩ 10kΩ ±(2.0% + 10 digits) Maximum Input: 600V AC RMS or 600V DC 60.00nF 10pF ±(5.0% + 35 digits) 600.0nF 0.1nF Capacitance 6.000µF 1nF 60.00µF 10nF ±(3.0% + 5 digits) 600.0µF 0.1µF 6000µF 1µF ±(5.0% + 5 digits) Maximum Input: 600V AC RMS or 600V DC 3

ENGLISH 4 ELECTRICAL SPECIFICATIONS 9.999Hz 0.001Hz 99.99Hz 0.01Hz Frequency 999.9Hz 0.1Hz 9.999kHz 1Hz ±(1.0% + 5 digits) 99.99kHz 10Hz 500.0kHz 100Hz Sensitivity: >8V RMS, Maximum Input: 600V DC or 600V AC RMS Duty Cycle 0.1% 99.9% 0.10% ±(1.2% + 2 digits) Pulse width: 0.1ms 100ms Frequency width: 5Hz to 10kHz Sensitivity: >8V RMS Maximum Input: 600V AC RMS or 600V DC OTHER MEASUREMENT APPLICATIONS Diode Test: Max. 1.5mA, open circuit voltage ~ 3.0V DC Continuity Check: Audible signal <50Ω, test current <0.35mA Sampling Frequency: 3 samples per second Low Impedence (Low Z): Input impedence: >3kΩ Max input: 600V RMS Auto Power off: After ~30 minutes of inactivity Overload: "OL" indicated on display, overload protection 1000V RMS in Voltage setting, 600V RMS in all other settings Polarity: "-" on display indicates negative polarity Non-Contact Voltage Detection: >90V AC Display: 3-5/6 digit, 6000 Count LCD WARNINGS To ensure safe operation and service of the meter, follow these instructions. Failure to observe these warnings can result in severe injury or death. Before each use, verify meter operation by measuring a known voltage or current. Never use the meter on a circuit with voltages that exceed the category based rating of this meter. Do not use the meter during electrical storms or in wet weather. Do not use the meter or test leads if they appear to be damaged. Use only with CAT III or CAT IV rated test leads. Ensure meter leads are fully seated, and keep fingers away from the metal probe contacts when making measurements. Use caution when working with voltages above 25V AC RMS or 60V DC. Such voltages pose a shock hazard. To avoid false readings that can lead to electrical shock, replace batteries when a low battery indicator appears. Do not attempt to measure resistance or continuity on a live circuit. Do not hold meter above hand & finger guard during use.

WARNINGS Always adhere to local and national safety codes. Use personal protective equipment to prevent shock and arc blast injury where hazardous live conductors are exposed. Usage of this meter in any way other than that specified by the manufacturer can impair safe operation, resulting in severe injury or death. To avoid risk of electric shock, disconnect leads from any voltage source before removing battery door. To avoid risk of electric shock, do not operate meter while battery door is removed. Alternating Current (AC) SYMBOLS ON METER A Amperage V Voltage Direct Current (DC) Audible Continuity Hz Frequency Diode Test % Duty-Cycle Capacitance Resistance (Ohms) Low Impedance + Positive Negative COM Common Ground Double Insulated Class II DC Current Zero Function Warning or Caution: To ensure safe operation and service of this meter, follow all warnings and instructions detailed in this manual. Risk of Electrical Shock: Improper use of this meter can lead to risk of electrical shock. Follow all warnings and instructions detailed in this manual. AC Measurement Negative Reading SYMBOLS ON LCD DC Measurement Data Hold AUTO Auto Ranging MAX Maximum Value Hold MIN Minimum Value Hold Low Battery Auto Power Off Diode Test Audible Continuity Inrush Current k kilo (value x 10 3 ) m mili (value x 10-3 ) M Mega (value x 10 6 ) n nano (value x 10-9 ) μ micro (value x 10-6 ) F Farads Ohms A Amps V Volts LoZ Low Impedence Hz Frequency (Hertz) % Duty Cycle 5

ENGLISH FEATURE DETAILS 11 16 9 7 3 15 1 4 12 5 2 14 6 13 10 16. Polarity markings (for DC current) NOTE: There are no user-serviceable parts inside meter. 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 8 1. 6000 count LCD display 2. Function selector switch 3. Clamp 4. "COM" jack 5. "VΩ" jack 6. Data Hold / Backlight button "RANGE" button 8. "MAX/MIN" button 9. SEL (select) / DC Zero button 10. INRUSH button 11. Clamp trigger (press to open clamp) 12. Arrow markings 13. Non-contact Voltage Testing Button 14. Non-contact Voltage Testing Sensor 15. Non-contact Voltage Testing LED Indicator 6 Visit us at www.testequipmentdepot.com

FUNCTION BUTTONS ON/OFF To power ON the meter, rotate the Function Selector switch 2 from the OFF setting to any measurement setting. To power OFF the meter, rotate the Function Selector switch 2 to the OFF setting. By default, the meter will automatically power OFF after aprox. 30 minutes of inactivity. To deactivate the auto power OFF functionality, press and hold the "SEL/DC ZERO" button 9 before powering ON from the OFF setting. When auto power OFF is deactivated, the Auto Power Off icon will not be visible in the display. SEL (SELECT) / DC ZERO BUTTON (FOR SECONDARY FUNCTIONS) The SEL/DC ZERO button 9 activates the secondary function for each application accessible by the function selector switch 2 : In Current A and Low Impedance modes, it toggles between AC and DC measurements. In Frequency/Duty Cycle setting, it toggles between these measurements. In Continuity/Resistance/Diode-Test setting, it toggles through these measurements in order. In DC current setting, pressing and holding for more than one second initiates the DC ZERO function. Subsequent DC current measurements automatically subtract the measurement that was present as an offset correction. The default function for each application is printed on the meter in white, the secondary functions in orange. An icon on the LCD display will indicate which function is active. DATA HOLD Press the Data Hold / Backlight button 6 to hold the measurement on the display. Press again to release the display to return to live measuring. BACKLIGHT Press and hold the Data Hold / Backlight button 6 for more than one second to turn ON the backlight. The backlight will automatically power OFF after 3 minutes of inactivity. RANGE The meter defaults to auto-ranging mode AUTO. This mode automatically determines the most appropriate measurement range for the testing that is being conducted. To manually force the meter to measure in a different range, use the Range button 7. 1. Press the "RANGE" button 7 to manually select measurement range (AUTO is deactivated on the LCD). Repeatedly press the "RANGE" button 7 to cycle through the available ranges, stopping once the desired range is reached. 2. To return to auto-ranging mode, press and hold the "RANGE" button 7 for more than one second (AUTO is reactivated). 7

ENGLISH FUNCTION BUTTONS MAX/MIN When the "MAX/MIN" button 8 is pressed, the meter keeps track of the Maximum and Minimum values as the meter continues to take samples. 1. When measuring, press "MAX/MIN" button 8 to toggle between the Maximum value (MAX) and Minimum value (MIN). If a new Maximum or Minimum, the display will update with the new value. 2. Press "MAX/MIN" button 8 for more than one second to return to normal measuring mode. INRUSH CURRENT Rotate the Function Selector switch 2 to the Current A setting and press INRUSH 10 prior to an inrush event to test for inrush current. While the meter monitors current waiting for the inrush event, "----" will be visible on the display. NON-CONTACT VOLTAGE TESTING Press and hold the "NCV" button 13 to test for AC voltage using the integrated non-contact voltage tester. Approach the conductor under test leading with the sensing antenna 14. The meter delivers visual warning signals via the LED indicator 15 and audible signals (beeps) when AC voltage is detected. Release the "NCV" button to exit NCV testing mode. NOTE: It is not recommended to perform continuity and NCV testing simultaneously, as both tests utilize the same audible signal, making it difficult to resolve which test is responsible for the audible alarm. NOTE: Only voltages of 90V AC or greater will be detected. 8

OPERATING INSTRUCTIONS CONNECTING TEST LEADS Do not test if leads are improperly seated. Results could cause intermittent display readings. To ensure proper connection, firmly press leads into the input jack completely. INCORRECT CORRECT TESTING IN CAT III / CAT IV MEASUREMENT LOCATIONS Ensure the test lead shield is pressed firmly in place. Failure to use the CATIII / CATIV shield increases arc-flash risk. 5/32" (4 mm) TESTING IN CAT II MEASUREMENT LOCATIONS CAT III / CAT IV shields may be removed for CAT II locations. This will allow testing on recessed conductors such as standard wall outlets. Take care not to lose the shields..7" (18 mm) 9

ENGLISH OPERATING INSTRUCTIONS AC/DC CURRENT (LESS THAN 2000A) AC Current is measured by pressing the clamp trigger 11 to open the clamp 3 and placing it around a current-carrying wire. When measuring, care should be taken to ensure that the clamp 3 is completely closed with trigger 11 fully released, and that the wire passes perpendicularly through the center of the clamp 3 in line with the arrow markings 12. WIRE To measure current: 1. Rotate the Function Selector switch 2 to the Current A setting. 2. The meter defaults to AC measurement. To measure DC, press the "SEL/DC ZERO" button 9 to toggle between AC and DC modes. The AC or DC icon on the LCD indicates which mode is selected. Note "AC" or "DC" on the display. 3. Place the clamp 3 around the wire. When measuring DC current, align the polarity markings 16 on the clamp with the polarity of the wire to avoid negative readings. The current measurement will be shown in the display. The meter will auto-range to display the measurement in the most appropriate range. To measure inrush current: 1. Rotate the Function Selector switch 2 to the Current A setting. Place the clamp 3 around the wire and press "INRUSH" 10. The Display 1 will show "----". Initiate the Inrush event and the inrush current will be captured and presented in the display. A second press of "INRUSH" 10 will reset the Inrush measurement, "----" will be presented on the display and the meter will wait for the next Inrush event. 2. Press and hold "INRUSH" 10 for more than one second to return to normal measuring mode. Disconnect test leads when measuring with the clamp. NOTE: If non-zero values are displayed prior to measuring in DC current mode, an offset correction may be required to improve accuracy. With meter in DC current mode, press and hold the "SEL/DC ZERO" button 9 for more than one second to initiate the DC current ZERO function. Subsequent DC current measurements automatically subtract the measurement that was initially present as an offset correction. 10

OPERATING INSTRUCTIONS AC/DC VOLTAGE (LESS THAN 1000V) 1. Insert RED test lead into VΩ jack 5, and BLACK test lead into COM jack 4, and rotate function selector switch 2 to the AC voltage V or DC voltage V setting. The AC or DC icon on the LCD indicates which setting is selected. -or- Black lead Red lead 2. Apply test leads to the circuit to be tested to measure voltage. The meter will auto-range to display the measurement in the most appropriate range. NOTE: If " " appears on the LCD, the test leads are being applied to the circuit in reverse. Swap the position of the leads to correct this. NOTE: When in a voltage setting and the test leads are open, readings of order mv may appear on the display. This is noise and is normal. By touching the test leads together to close the circuit the meter will measure zero volts. Do not attempt to measure voltages greater than 1000V in any Voltage setting. AC/DC LoZ VOLTAGE (LESS THAN 600V) 1. Insert RED test lead into VΩ jack 5, and BLACK test lead into COM jack 4, and rotate function selector switch 2 to the AC/DC LoZ voltage setting. The meter defaults to AC measurement. To measure DC, press the "SEL/DC ZERO" button 9 to toggle between AC and DC modes. The AC or DC icon on the LCD indicates which mode is selected. Note "AC" or "DC" on the display. Black lead Red lead 2. Apply test leads to the circuit to be tested to measure voltage. The meter will auto-range to display the measurement in the most appropriate range. Do not attempt to measure voltages greater than 600V in LoZ setting. 11

ENGLISH OPERATING INSTRUCTIONS CONTINUITY 1. Insert RED test lead into VΩ jack 5, and BLACK test lead into COM jack 4, and rotate function selector switch 2 to the Continuity/Resistance/Diode-Test setting. Black lead Red lead NOTE: The meter defaults to Continuity testing in this setting. Ensure that the Continuity Testing icon is visible on the display. If not, press the "SEL/DC ZERO" button 9 repeatedly until the icon is shown. 2. Remove power from circuit. 3. Test for continuity by connecting conductor or circuit with test leads. If resistance is measured less than 50Ω, an audible signal will sound and display will show a resistance value indicating continuity. If circuit is open, display will show "OL". DO NOT attempt to measure continuity on a live circuit. RESISTANCE MEASUREMENTS 1. Insert RED test lead into VΩ jack 5, and BLACK test lead into COM jack 4, and rotate function selector switch 2 to the Continuity/Resistance/Diode-Test setting. Black lead Red lead NOTE: The meter defaults to Continuity testing in this mode. Press the SEL/DC ZERO" button 9 once to enter Resistance testing mode. The Resistance icon will appear on the display. 2. Remove power from circuit. 3. Measure resistance by connecting test leads to circuit. The meter will auto-range to display the measurement in the most appropriate range. NOTE: When in a Resistance setting and the test leads are open (not connected across a resistor), or when a failed resistor is under test, the display will indicate O.L. This is normal. DO NOT attempt to measure resistance on a live circuit. 12

OPERATING INSTRUCTIONS DIODE TEST 1. Insert RED test lead into VΩ jack 5, and BLACK test lead into COM jack 4, and rotate function selector switch 2 to the Continuity/Resistance/Diode-Test setting. Black lead Red lead NOTE: The meter defaults to Continuity testing in this mode. Press the SEL/DC ZERO" button 9 twice to enter Diode testing mode. The Diode icon will appear on the display. 2. Touch test leads to diode. A reading of 200-800mV on display indicates forward bias, "OL" indicates reverse bias. An open device will show "OL" in both polarities. A shorted device will show approximately 0mV. FREQUENCY / DUTY-CYCLE 1. Insert RED test lead into VΩ jack 5 and BLACK test lead into COM jack 4, and rotate function selector switch 2 to the Frequency/Duty-Cycle setting. Black lead Red lead NOTE: : The meter defaults to Frequency testing. To test Duty-Cycle, press the "SEL/DC ZERO" button 9 once. Ensure that the appropriate icon (either Hz or %) appears on the display. 1. Measure by connecting test leads across the circuit. 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com 13

ENGLISH OPERATING INSTRUCTIONS CAPACITANCE 1. Insert RED test lead into VΩ jack 5, and BLACK test lead into COM jack 4, and rotate function selector switch 2 to the Capacitance setting. Black lead Red lead 2. Remove power from circuit. 3. Measure capacitance by connecting test leads across the capacitor. The meter will auto-range to display the measurement in the most appropriate range. MAINTENANCE BATTERY REPLACEMENT When indicator is displayed on LCD, batteries must be replaced. 1. Loosen screw on battery door. 2. Replace 2 x AAA batteries (note proper polarity). 3. Replace battery door and fasten securely with screw. 14 To avoid risk of electric shock, disconnect leads from any voltage source before removing battery door. To avoid risk of electric shock, do not operate meter while battery door is removed.

CLEANING Be sure meter is turned off and wipe with a clean, dry lint-free cloth. Do not use abrasive cleaners or solvents. STORAGE Remove the batteries when meter is not in use for a prolonged period of time. Do not expose to high temperatures or humidity. After a period of storage in extreme conditions exceeding the limits mentioned in the General Specifications section, allow the meter to return to normal operating conditions before using. DISPOSAL / RECYCLE Do not place equipment and its accessories in the trash. Items must be properly disposed of in accordance with local regulations. Please see www.epa.gov or www.erecycle.org for additional information. 15

ENGLISH NOTES