Conductivity / Temperature Transmitter LMIT 09

Similar documents
Measuring and Controlling Unit Multronic OC

Measuring and Controlling Unit Multronic

The transducer component converts the measured signal and displays the actual value.

Type PLC Fitting. Valve for Continuous control. Diaphragm valve. Output

Digital inductive conductivity transmitter

Digital conductivity transmitter

Conductivity measurement SmarTec S CLD 132

Inductive conductivity transmitter JUMO CTI-Junior

RTD Temperature Sensor omnigrad T -TSM 480, TR 480. Hygienic RTD sensor with Pt 100, class A TSM 480 with electronics programmable via PC

JUMO CTI-500. Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Type Brief description.

LCI. Inductive Conductivity/ Concentration and Temperature Transmitter. Compact or separate version

Technical Information Smartec CLD18

Technical Information Smartec CLD18

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts. Temperature sensor. Graphics LC display.

Indumax CLS50/CLS50D. Technical Information

Magnetic-Inductive flow Meter fmi

omnigrad T - TSM 480, TR 480. Technical Information. RTD Temperature Sensor Hygienic design TSM 480 with electronics programmable via PC

Indumax CLS54D. Technical Information

Technical Information Memosens CLS82D

Technical Information Smartec CLD18

Conductivity sensor for hygienic applications

Conductivity Transmitter

Inductive Conductivity/Concentration and Temperature Transmitter with switch contacts

Inductive Conductivity Meter ILM

Inductive conductivity measurement mypro CLM 431 / CLD 431 inductive

SITRANS F flowmeters SITRANS F M. Transmitter Transmag 2 with sensor 911/E 4/77. Overview

Analog outputs (option) Outputs 1 + 2: 0(4) - 20 ma or 0-10 V

Ultrasonic level transmitter, non-contact

ph or ORP Transmitter

JUMO Wtrans E01. Measuring probe for humidity, temperature, and CO 2 with wireless data transmission. Brief description. Universal Wtrans receiver

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

prosonic T FMU230, FMU231

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Stroke length mm. Perfect data processing 0.

Conductive conductivity measurement mypro CLM 431 / CLD 431 conductive

JUMO Dtrans T100 Screw-in RTD Temperature Probe with/without Transmitter

Electro-Magnetic Flowmeters COPA-XE

Liquid level monitors and controls

A Higher Level of Performance. Data Sheet. Series Pressure and Level Transmitters. For more information, please visit >

Flow Measurement SITRANS F M

Smartec S CLD134. Technical Information

SITRANS F flowmeters SITRANS F US. Transmitter FUS060. Overview

4.00 ULTRASONIC ANALYZER

Digital flow transmitter for continuous flow measurement

Temposonics. R-Series SSI. Absolute, Non-Contact Position Sensors. Temposonics RP and RH Measuring length mm. Perfect data processing I 7 I

Electromagnetic Flow Transmitter

Continuous Level Sensor NSL-M

FAST SAMPLING CONVERTER

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Digital flowmeter for continuous flow measurement

Digital flowmeter for continuous flow measurement

Valve Island with Electronic I/O

P R o D u c T I n F o R m at I o n. TDR Level Sensor LFP. The clean solution

Miniature resistance thermometer Model TR33, thread-mounted

Conductivity Analyzer

J Series induq VMZ MAGNETIC INDUCTIVE FLOW SENSORS. DB_Magnetic_Inductive_Flow_Sensors 05/2016

JUMO ecotrans Lf 03 Microprocessor Transmitter / Switching Device for conductivity or resistivity and temperature

KFS. Flap-type flow meter. Design and range of application

Resistance thermometers for process technology

Content. Flow meter F2-UN. Description Technical Data Dimension drawings Operation... 8 Mounting instructions...

Analog outputs (option) Output 1 + 2: 0(4) 20 ma or 0 10 V

OPTITEMP TT 20 Technical Datasheet

Conductivity Measuring Cells for High-Temperature Applications ConduMax H CLS 16

Pharma Temperature Sensor TFP-EX

Flow Switch - 2 programmable thresholds. Stand Alone (Battery) - Battery powered, - 2 totalizers display, - Local flow display,

Conductivity-Converter

High-precision process calibrator Model CED7000

Digital flow ELEMENT transmitter for continuous flow measurement

Condumax W CLS15 and CLS15D

High-sensitivity with vertical hole. PFA 2.6/cm (260/m) C 1.0 MPa or less Approx. 19kg Approx. 10kg (L: 500) Outdoor installation Rainproof type

Digital flow ELEMENT transmitter for continuous flow measurement

Magnetic Inductive Flow Sensors induq. Series VMI

Technical Information Indumax CLS50D/CLS50

Pharma-Temperature Sensor M12 hygienic

TARAtec P9. Data Sheet

Design and applications

SonoSelect 10 and SonoSafe 10 Energy Meters

Pharma Temperature Sensor G3/8"

Resistance thermometer Model TR31, miniature design

B850 Boiler House Energy Monitor

P5201 Universal Programmable Transmitters with Galvanic Isolation

( F L O W I Z F A M I L Y )

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

DN 16 ISO-KF. Dimensional drawings THERMOVAC TM 101 (mm)

ED701 General Industry Pressure Transmitter

Digital batch controller

DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters DSCL, DSCP, SCTP. Industrial Loop Isolators and Transmitters

Magnetic Inductive Flow Sensors VMI Series

Alfa Laval Conductivity Sensor

ma output signal with transmitter module. - Adjustable frequency output signal with pulse divider module

Condumax W CLS19. Technical Information. Conductivity sensors Two-electrode sensors with cell constants k = 0.01 cm 1 or k = 0.

Operating instructions Measured signal converter for temperature sensors TP / / 2010

SITRANS F flowmeters SITRANS F US. Transmitter FUS080. 4/194 Siemens FI

Capacitive Limit Switch Pharma NCS

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Temperature Sensor with M12 hygienic

XXXX e. X d.. X X X a

XXXX e. X d.. X X X a

Multi-electrode Conductivity Analyzers

High-quality digital indicator for panel mounting Model DI35-M, with multi-function input Model DI35-D, with two inputs for standard signals

SITRANS F flowmeters SITRANS F US SONOCAL /184 Siemens FI

Transcription:

Conductivity / Temperature Transmitter ONE unit for CIP applications, concentration monitoring and make-up Measurement value logging covering five decades of measurement ranges from 0-200 µs/cm to 0-2 S/cm with an accuracy of ± 1 µs/cm at inductive conductivity measurement Equipped with Pt100 sensor, -20 C +150 C Two electrically isolated current outputs 0/4-20 ma for conductivity and temperature USB port for simple updating and upgrading Alarm output with zero-potential changeover contact With the wall-mounted version a separate probe with 5 m or 20 m cable is connected to the transmitter Permanently lit display with: Concentration display as weight percentages with product name or conductivity values in µs/cm / ms/cm / S/cm Measured temperature values in C or F Temperature coefficient and reference temperature (at conductivity measurement) Output current values for conductivity and temperature Active CIP field (only with configuration) Operation symbols for the keys in the submenus Measure cell body (probe) is of the highly resistant material PEEK, without bonding seams and joint made in one cast Measure cell resistant to chemicals and temperature EHEDG-certified measure cell HD (hygienic design) The conductivity/temperature transmitter LMIT 09 offers process security due to an innovative measuring technology. The quality of a fluid is basically determined by measurement of its specific conductivity. Examples of this quality determination method are: Phase separation during CIP applications Concentration monitoring for detergent and disinfectant solutions Monitoring of water quality Quality control for liquid products Process control by online measuring Contamination monitoring of food For an exact determination of substance concentrations, e.g. for detergents and disinfectants, it is essential to take the actual temperature into account. It is measured by means of the Pt100 temperature sensor, which shows optimal flow characteristics and a short response time (T90 < 5 s). All captured data are corrected with respect to the stored stereoscopic concentration graphs and temperature compensation factors. This results in an accurate and quick determination of the temperature and concentration of the conductive fluids. 06/2014 LMIT_09_e.doc 1

Conductivity /Temperature Transmitter Technical Data Transmitter housing Type: Deep-drawn high-grade steel Dimensions: 160 x 130 x 75 mm (L x B x H) Weight: Approx. 3 kg Type of protection: IP 67 acc. to DIN 40050 Housing bushings: 3 screw connections PG 13.5 (1 seal insert each for 4-6.5 / 5.5-9 / 6.5-10 mm) Transducer connection: PG 13.5; only for separate measuring cell version Transducer Type: Material: Cylindrical calotte with 10 mm measuring channel diameter PEEK Dimensions: 55 x 53 mm (d h) Pressure resistance: PN = 16 bar at 20 C (see diagram) Temperature stability: Up to max. 130 C for short period up to max. 140 C (approx. 30 min) Chemical resistance: Resistent to inorganic acids and alkalis Temperature sensor: Pt 100 DIN in protective tube (material: 1.4404) Sealing element: O-ring, 62 x 3 EPDM (Art. No. 417001502) for clamp ring attachment (VARIVENT) Moulded seal, EPDM (Art. No. 415501251) for flange connection Transmitter with integrated transducer (compact version) Assembly: Fitting type: Clamp ring attachment (VARIVENT-SYSTEM) or flange connection Flow fitting 1.4404 for installation in piping DN 40, 50, 65, 80 and 100 mm with weld connection. Weld-on ring (for VARIVENT system only) 1.4404, for installation in piping > DN 100. Weld-on ring 1.4404 for tank wall installation Transmitter with separate transducer (wall-mounted version) Transmitter assembly: Transducer assembly: Fitting type: Fixing angle for wall mounting assembly Connection lead: 5 m (optional: 20 m) Type of cable: Clamp ring attachment (VARIVENT system) or flange connection Flow fitting 1.4404 for installation in piping DN 40, 50, 65, 80 and 100 mm with weld connection. Weld-on ring (for VARIVENT system only) 1.4404, for installation in piping > DN 100. Weld-on ring 1.4404, for tank wall installation 6-pole special measuring cable, cut to length Connection measuring cable: fixed connection on sensor side free wire ends with wire end ferrules on unit side 06/2014 LMIT_09_e.doc 2

Conductivity /Temperature Transmitter Conductivity measurement Measuring principle: Measuring frequency: Conductivity measuring ranges: Standard product measuring ranges: Ecolab cleaning and disinfectant product measuring ranges: Customer product measuring ranges: Measuring range selection: Induction method Approx. 8 khz 0... 200 µs/cm 0... 2 ms/cm 0... 20 ms/cm 0... 200 ms/cm 0... 2 S/cm * measuring range limiting value: 2.5 S/cm or [æ ref * α * (T - T ref) < 2,5 S/cm] NaOH = 0... 5 % by weight HNO 3 = 0... 5 % by weight H 2SO 4 = 0... 5 % by weight 0... 5 % by weight Definition of four own product graphs with 4-10 nodes, temperature coefficient and reference temperature Via keyboard in unit or also 24 V control signals (for PROFIBUS version also via PROFIBUS DPV1/PA protocol); internally up to 5 conductivity measuring ranges and more than 70 product measuring ranges are available for selection Conductivity display: digital, correct to 3 digits with units conductivity in µs/cm, ms/cm or S/cm Product display: Product name and concentration in % by weight, digital, 3-digit Temperature measurement Measuring principle: Temperature measuring range: Temperature display: Resistance measurement with Pt 100 DIN using 3 wire connection method; linearization acc. to DIN IEC 751-50 to 150 C digital 3 ½ digit in C with a resolution of 0.1 C (above 100 C resolution 1 C) Accuracy: +/- 0.5 C (from 0 to 100 C) Response time: t 90 < 5 sec. from 0 90% for flowing medium Temperature compensation Reference temperatures: TC setting range: Function range of temperature compensation: TC display: digital, 3 digit in % Resolution: Automatical Tkα determination: 0 C, 20 C, 25 C or manually adjustable (0 C 55 C); selectable with keyboard in unit 0... 5 %/K in increments of 0.01 %/K; selectable with keyboard in unit 0 100 C and [Tkα/100 (T-Tref) - 0.5] 0.01 %/K call-up of function in the calibration menu; change of min. 5 C temperature necessary 06/2014 LMIT_09_e.doc 3

Conductivity /Temperature Transmitter Measured value outputs Current output conductivity: Max. load impedance: Electrical connection: Range spread (SPAN) [20 ma]: Zero point suppression: Damping: Alarm current: 0(4)... 20 ma for set measuring range, electrically isolated 400 Ω plug-in screw terminals 20 150% of conductivity measuring range 20 100% of product measuring range 0(4) ma = 0 80 % of measuring range OFF, 1 10 sec. adjustable (factory setting OFF) 0 ma, 2.4 ma and 22 ma adjustable (factory setting 0 ma) Current output temperature: 0(4)... 20 ma, electrically isolated Max. load impedence: 400 Ω Electrical connection: plug-in screw terminals Range spread (SPAN): 20 ma = 50...150 C Zero point suppression: 0(4) ma = - 10 C 50 C Factory setting: 0(4)... 20 ma = 0... 100 C Damping: OFF, 1 10 sec. adjustable (factory setting OFF) Alarm current: 0 ma, 2.4 ma and 22 ma adjustable (factory setting 0 ma) Power supply Supply voltage: 24 V AC or DC Tolerance: ± 15 % Power consumption: approx. 6 VA Fuse protection: 5 x 20 mm miniature fuse 400 ma, slow-acting Electrical connection: plug-in screw terminals Ambient conditions Permitted ambient temperature: 0... 50 C Influence of ambient temperature: Influence of supply voltage: < 0,2 % / 10 K within the permitted range < 0,5 % within the permitted range Permitted vibration: 10... 150 Hz, 20 m/s 2 06/2014 LMIT_09_e.doc 4

Conductivity /Temperature Transmitter Accuracy of conductivity measuring (referring to current output) Conductivity measuring ranges: Linearity: Reproducibility: Zero point error: Load dependence: 0...200 µs/cm*, 0...2/20/200 ms/cm und 0...2 S/cm < 0.5 % of final value ± 1 digit < 0.5 % of final value ± 1 digit < 0.5 % of final value ± 1 digit < 0.2 %/100 Ω load change * For standard devices: >10µS/cm after calibration in the employed flow fitting Stored product data HNO 3 H 2SO 4 NaOH Ecofoam AC Ecofoam CL Ecofoam HA P3-ansep ALU P3-ansep CIP P3-aquanta BI P3-aquanta OP P3-aquanta PA P3-aquanta PC P3-aquanta SI P3-aquanta XTR P3-AR extra P3-cosa CIP 72 P3-cosa CIP 77 P3-cosa CIP 92 P3-cosa CIP 95 P3-cosa FLUX 33 P3-cosa FLUX 44 P3-cosa FLUX 55 P3-cosa PUR 83 P3-cosa PUR 84 P3-flüssig 141 P3-flüssig 2083 P3-flüssig OS P3-horolith 283 P3-horolith BSR P3-horolith CD P3-horolith CIP P3-horolith FL P3-horolith KEG P3-horolith MSW P3-horolith PA P3-horolith PM P3-horolith TR P3-horolith USP P3-horolith V P3-liquid CIP P3-liquid OS P3-mip 100 P3-mip AH P3-mip ALU P3-mip CIP P3-mip EA P3-mip FL P3-mip flüssig P3-mip HP P3-mip LF/LFT P3-mip LH P3-mip RC P3-mip SP P3-mip TK P3-mip VA P3-mip VL P3-mip zentra P3-N421 P3-oxonia active S P3-oxysan CM P3-polix XT P3-Rinsa black P3-risil MAT P3-SR395 P3-tresolin CIP P3-trimeta CID P3-trimeta CIDsp P3-trimeta Duo P3-trimeta ES P3-trimeta HC P3-trimeta MS P3-trimeta OP Trimeta Plus Trimeta PSF Alarm output Relay contact: zero-potential changeover contact (max. 30 VDC / 1 A; 125 VAC / 0.3 A) Function (reversible): Electrical connection: in case alarm relay has fallen (factory setting) or risen plug-in screw terminals CIP version (configurable) additional components: 2 or 4 externally selectable CIP configurations and current output assignments selection of CIP configurations is effected by 24 V AC/DC signals PROFIBUS version additional components: up to 4 externally selectable CIP configurations and current output assignments external and internal configuration and parameterization (DPV1) as well as alarm and status messages interface: RS 485 Baud rate: 9.6 kbaud up to 12 MBaud automatic Baud rate detection Connection resistance: 120 Ω, shiftable, lead type A Note: We reserve the right to make technical modifications to our products in order to keep them up to date. 06/2014 LMIT_09_e.doc 5

Conductivity /Temperature Transmitter Order Data Article/Designation Material No. Standard Version Conductivity/Temperature Transmitter with clamp ring attachment: Compact version 189201 Wall-mounted version, 5 m 189202 Wall-mounted version, 20 m 189203 HD version Conductivity/Temperature Transmitter with clamp ring attachment: Compact version 189209 Wall-mounted version, 5 m 189210 PROFIBUS DPV1 version Conductivity/Temperature Transmitter with clamp ring attachment: Compact version 189206 Wall-mounted version, 5 m 189207 PROFIBUS PCB For upgrading the standard version for PROFIBUS DP/V1 289256 Power pack for including a connecting cable Primary stress 240 V AC (cable length: 1.5 m) Secondary stress 24 V AC (cable length: 4.5 m) System of protection IP 65 418931008 Conductivity simulator for With 5 measuring-range-specific simulation resistors 289190 Conductivity simulator 200µS for With measuring-range-specific simulation resistor 289191 06/2014 LMIT_09_e.doc 6

Measurement System Configuration Versions and Dimensions compact version tube installation with clamp ring attachment wall-mounted version compact version tube installation with flange connection type: flow fitting (DIN 11850) material: 1.4404, sealing EPDM type: weld-on ring for tank wall installation material: 1.4404, sealing EPDM type: weld-on ring for pipe mounting material: 1.4404, sealing EPDM type: weld-on ring for tank wall installation material: 1.4404, sealing EPDM type: flow fitting material: 1.4404, sealing EPDM clamp ring attachment flange connection 06/2014 LMIT_09_e.doc 7

Measurement System Configuration Suggested Solution Measurement system configuration in by-pass to circulation pump, with short return to tank installation by welding Attention! Measuring enable only during operation of delivery pump P1 stack solution container cleaning circuit installation by welding a 1b Delivery pump and pipe provided by customer Measurement system configuration in by-pass, consisting of: 1a or Item Quantity Material No. Flow-through housing DN 40 (clamp ring attachment) 1 415501223 1b Flow-through housing DN 40 (flange connection) 1 2 Reducer d 42.6 26.9 mm concentric, V2A seamless 2 415508884 3 Weld-on sleeve G ½, V2A 4 4 Cutting-ring screw connection G ½ for 12 x 1.5 mm tube 4 415101885 5 12 x 1.5 mm tube, V2A 4 m 415031164 6 Ball stop cock G ½, V4A 2 415502024 7 Double nipple G ½, V2A 2 415203604 8 Teflon sealing tape (roll) 1 417100813 06/2014 LMIT_09_e.doc 8

Measurement System Configuration Accessories Order Data Article/Designation Flow-through housing with clamp ring attachment Sealing material: EPDM Surface: matted Material: 1.4404 Housing, design: 2 open weld-on ends and clamp ring attachment for measuring calotte including all attachment parts, lock covers and seals DN 40 DN 50 DN 65 DN 80 DN 100 Material No. 415501223 415501224 415501220 415501221 415501222 Lock cover, 1.4571 415501232 Clamp ring set, 1.4571 415501231 Hexagon nut, 1.4301 413228215 Hexagon head screw, 1.4301 413000270 O-ring, EPDM, 62 x 3 417001502 Dimensions in mm DN C (length = 2 x C) 40 90 68 36 50 90 68 42 65 125 68 50 80 125 68 57,5 100 125 68 67 weld-on endings DN Ø (external diameter) internal diameter wall thickness 40 41 38 1,5 50 53 50 1,5 65 70 66 2 80 85 81 2 100 104 100 2 D K 06/2014 LMIT_09_e.doc 9

Measurement System Configuration Accessories Order Data Accessories: Article / Designation Material No. Flow-through housing with clamp ring attachment with flanges acc. to DIN 2633 Sealing Material: EPDM Surface: matted Material: 1.4404 DN 40 / PN 16 DN 50 / PN 16 Flow-through housing, chemical design but with Viton seal and halar-coated housing inside DN 40 / PN 16 DN 50 / PN 16 O-ring Viton B 60 x 2 Weld-on adapter with clamp ring attachment Material: 1.4404 Welding ring for fitting of the measuring cell into pipes >DN 100; including attachment parts and sealing ring; way of welding: welded muff 415501234 Weld-on ring for fitting of the measuring cell into the container side walls; including attachment parts and sealing ring; way of welding: welded muff Sealing ring, EPDM Lock cover, 1.4571 Clamp ring set, 1.4571 289033 417001502 415501232 415501231 06/2014 LMIT_09_e.doc 10

Measurement System Configuration Accessories Article / Designation Material No. Flow-through housing with flange attachment Sealing Material: EPDM Surface: matted Material: 1.4404 Housing, design: 2 open weld-on ends and connection mouth for measuring calotte; including all attachment parts, lock covers and seals DN 40 DN 50 415501262 DN 65 415501263 DN 80 DN 100 415501265 Form seal, EPDM 415501251 Weld-on ends DN Ø external Ø internal wall thickness 40 41 38 1,5 50 53 50 1,5 65 70 66 2 80 85 81 2 100 104 100 2 06/2014 LMIT_09_e.doc 11

Measurement System Configuration Spare Parts Order Data Spare Parts: Article / Designation Material No. transducer with clamp ring attachment for wall-mounted version (not usable for HD version) cable length 5 m cable length 20 m transducer with flange connection* for wall-mounted version, cable length 5 m transducer with clamp ring attachment* Pharma version for wall-mounted version cable length 5 m * Please also check the measuring transmitter before you replace the transducer. After the replacement of the transducer, the transmitter must be recalibrated in the used flow fitting. A check by the manufacturer is recommended! 06/2014 LMIT_09_e.doc 12