Seismograph Sales Options

Similar documents
VMS-4000 Digital Seismograph System - Reference Manual

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

SXL will proceed with the implementation of this Vibration Monitoring Plan unless otherwise advised to modify.

Signature Hole Analysis. What is Signature Hole Analysis and why is it such a hot topic in the industry?

Terms of Reference of Aircraft Noise at IGI Airport, New Delhi

MA24104A. Inline High Power Sensor. True-RMS, 600 MHz to 4 GHz

QUICK GUIDE for multiguard Light. Installation

SAPLING WIRELESS SYSTEM

Wireless Data Acquisition System. Hasan Ozer and Mat Kotowsky. An Application to Crossbow s Smart Dust Challenge Contest

Bench LCR Meter Model 891

XLR PRO Radio Frequency (RF) Modem. Getting Started Guide

CR:247 Invictus. Portable Noise Monitor. Features. Features. Applications

Battery Powered People Counter with Integral LCD Display & 418Mhz Data Transmitter

Mars Rover: System Block Diagram. November 19, By: Dan Dunn Colin Shea Eric Spiller. Advisors: Dr. Huggins Dr. Malinowski Mr.

Above All. The most sophisticated unit for tracking containers in real time for security and management.

THE ANV MEASUREMENT SYSTEMS SOUND INSULATION TESTING SYSTEM INSTRUCTION MANUAL FOR FIELD TESTING OF WALLS, FLOORS & STAIRS

JD723A/JD724B/JD726A Cable and Antenna Analyzers

Microphone Probe. ReallyEasyData. com

General purpose Signal generation and analysis. Well-equipped for field and lab the R&S Spectrum Rider

Continuous, remote monitoring and logging of electromagnetic fields

Choosing the Right PowerSight Model. No matter what your needs or budget there is probably a PowerSight model that is right for you

The wireless alternative to expensive cabling...

TC-3000C Bluetooth Tester

Mean currents and turbulence, plus wave height, direction and ice tracking

Choosing the Right PowerSight Model

Uni-Mux XQL Multi-Channel Data Acquisition Module

Specifications for: OSOP Sixaola4-V4

Intelligent and Flexible Monitor Circuits Detect & Record Load Profiles and Fault Events All Distribution Voltages All Conductor Types

A Super trainer with advanced hardware and software features only found in very expensive equipment.

nvision Reference Recorder

Stationary & Cloud jamming Presentation 2013

Wind Turbine Analysis System - Type 3652 MKII & MKIII

CEL63x Sound Level Meter CEL630, CEL631, CEL632, CEL633 Class 1 or Class 2. Integrating. Advanced Logging. Audio Recording

Identifying noise levels of individual rail pass by events

Continuous, remote monitoring and logging of electromagnetic fields

Panel Mount PLC. NEW standard: Timer + Counter + Temperature Controller + PLC. The FP-e PLC comes in the following three types

Technical Report Noise and Vibration

4830B accelerometer simulator Product overview

CamFi TM. CamFi User Guide. CamFi Remote Camera Controller. CamFi Limited Copyright 2015 CamFi. All Rights Reserved.

3 Phase Power Quality Analy er

AUTOMATIC ELECTRICITY METER READING AND REPORTING SYSTEM

Reflectometer Series:

9/2/2013 Excellent ID. Operational Manual eskan SADL handheld scanner

Continuous, remote monitoring and logging of electromagnetic fields

ULTRA RAPID POWER QUALITY ANALYZER

OFFSHORE ENERGY. BUYER S GUIDE HYDROlog Hydrotest Logger Range. Simply advanced

Development and Field Testing of a Seismic System for Locating Trapped Miners - Progress Report. Yi Luo, Keith A. Heasley and Syd S.

SCATT Biathlon shooting trainer User s Manual

Power Quality Recorders with Wireless Communications

Improve asset protection and utilization

Digital insulation tester

Save Money and Decrease Downtime with Vehicle and Equipment Monitoring. Embedded Technology Summit National Instruments

Installing the IPS 4240 and the IPS 4255

Choosing your power quality analyzer

Test Plan for Hearing Aid Compatibility

The wireless alternative to expensive cabling...

Within reach. The standard for online machine surveillance

SETTOPSURVEY, S.L. Bofarull 14, Barcelona (Spain) Phone: (+34) Fax: (+34)

Table Of Contents Overview of the operating buttons... 4 The functions of the datalogger... 5 How to start logging from the default settings...

DATACAR ADVANCED MULTILANE TRAFFIC MONITORING SYSTEM

Connecting Mains Electrical Power

Instruction also available on

Environmental Noise Measurement Kits

MEASURING INSTRUMENTS AND TESTERS

Agilent U8903A Audio Analyzer

TOSHIBA MACHINE CO., LTD.

WEB I/O. Wireless On/Off Control USER MANUAL

SonoLab Echo-I User Manual

Bloodhound RMS Product Overview

Technical Datasheet GT-8550B Series USB Power Sensor 10 MHz to 26.5 GHz

Protocol for Ambient Level Noise Monitoring

Wireless Data Logger RTR-500 Series Data Loggers Features and Specs

Precision Delay Your Station In Sync and On Time

Ultrasonic transducers being installed in the 2.4m (96 ) aqueduct at Watchgate WTW, Cumbria, UK.

Main Features. Highlights

HF Transceiver Codan NGT SR. HF Transceiver Codan NGT SR

khz to 2.7 GHz Spectrum Analyzer

INSTRUCTION MANUAL. IBRit - rf1 - usb PC - Station for wireless Data transmission. M e s s t e c h n i k. Messtechnik GmbH & Co.

The LEBOW 7554 Operator's Manual 7.2

TECHNICAL DATASHEET #TDAX QUAD VALVE CONTROLLER P/N: AX SERIES

Advanced Test Equipment Rentals ATEC (2832)

High Performance Process & Temperature Controllers

AUTOMATIC WEATHER AND HYDROLOGICAL STATIONS

Setup Utility Guide. ADX-0808 and ADX-1616 Audio Matrix Pre-amp Systems

Leica Digisystem i-series Safe and fast location of underground utilities

PLANAR R54. Vector Reflectometer KEY FEATURES

SLX-1 Multi-Application GNSS Receiver

VRS20. Contents. Communications. Stay involved. RS232 Communications. 2/14/2014 VRS20 - Valeport

UPS (Uninterruptible Power Supply) Digital Signal Processor CM COMANDOS LINEARES CM COMANDOS LINEARES

An integrated approach of signature hole vibration monitoring and modeling for quarry vibration control

R-Log Radio data logger

LUXONDES. See the electromagnetic waves. Product 2018 / 19

How to make a list sweep measurement

Model 931A Power System Analyzer. Model 930A Three Phase Power Analyzer. Model 929A Three Phase Power Meter. with. Digital Signal Analysis

NeuLog photo gate logger sensor NUL-209

Comparative Field Qualification of ACM and ACSM Systems at Sycamore, IL. Thomas Koegel

Container Crane. Presentation

High power radio transmission module MR03 type

PROCESS & TEMPERATURE CONTROLLERS

Choosing the Right PowerSight Model. Comparison Table between PowerSight models**

Transcription:

Seismograph Sales Options VanguardNewYork.com

Providing Seismograph Sales & Monitoring Services to the Construction Industry. Vanguard Construction Solutions provides construction monitoring services in the Northeastern US to ensure your construction projects comply with local, city and state regulations while minimizing costs. We are a leading provider of seismographs for purchase specifically for construction vibration monitoring. As an authorized distributor of White Industrial Seismology products, we provide the support services needed to have confidence in your seismograph purchase. As an added bonus, data downloading and vibration analysis software is provided at no extra cost when you purchase a seismograph from us.

Data & Reporting We understand that being able to quickly turnaround well organized, detailed reports is a must in the construction industry. Accurately document your project, meet deadlines, and stay organized. You ll be able to print, download, view and send customizable reports that look professional and meet any required compliance standards. Features Easy to read data format Customizable report content Sort & filter events Alter graph scaling Separate Particle Velocity vs. Frequency Charts Color coded data Seismograph equipment settings Internet Public Telephone System Cellular Wireless Network Forwarding PC Web Based Vibration Monitoring Our seismograph equipment can be left unattended for web based vibration monitoring via internet connection. You ll be able to receive and monitor vibration data as well as transfer it to a password-protected web site for others to view. This service is ideal for timesensitive projects or large projects that utilize several seismographs at once where reporting requirements are very strict. Clients Server Key Benefits Safe, secure & reliable data. Save both time & money. 24/7 access to data. Collect, store & distribute data conveniently. For more information about buying seismograph equipment visit www.vanguardnewyork.com or call 845-803-0295

Mini-Seis III - The Next Generation The Mini-Seis III is our next generation seismograph. It supports USB for data transfer to a computer and thumb drive. It has over 500 MB of memory and can store over 1000 waveform records. It has an easy-to-read display and is designed for low power. Operating modes include Waveform, Histogram, Histogram/Waveform & Manual Trigger. A system log tracks when the instrument is turned on and off, changes are made to the operational setup, and whether or not any triggers occurred during a waveform operation. Options include A-weighting and special ranges. This package is available at a very affordable price. Mini-Seis III Quick Features Sampling rates from 1024 to 4096 over 4 channels. Rates of 8192, 16384 & 65536 are in development. Waveform duration from 1 to 120 seconds over all sample rates. Selectable 16 or 12 bit resolution when retrieving data. Memory storage for over one thousand waveform & histogram records. Direct data retrieval via USB and/or USB thumb drive. Serial baud rates up to 230400. External printing option. Remote access with approved cellular modem. Waveform, Histogram, Histogram/Waveform and Manual Trigger modes. Special sensitivity options.

VanguardNewYork.com Mini-Seis III Technical Specifications - More specifications at VanguardNewYork.com Channels 3 seismic & 1 acoustic channels standard optional 8 channel upgrade available. Seismic (tri-axial geophone package) Range Standard 254 mm/s (10 in/s). Resolution 0.008 mm/s (0.0003 in/s). Frequency Range (ISEE) Varies with sample rate, from 2 to 250 Hz at 1024 samples/s. Frequency Range (DIN) Varies with sample rate, from 2 to 250 Hz at 1024 samples/s. Accuracy (ISEE) 1 to 315 Hz (minimum 2048 sample rate needed). Conforms with the ISEE Performance Specifications for Blasting Seismographs. Accuracy (DIN) DIN 45669-1 Standard. Transducer Density Approximately 2.01 g/cc (125 lb./ft3). Acoustic Weighting Linear Weighting or A Weighting. Linear Range 58 to 148 dbl (512 Pa, 5.12 Mb, 0.074 PSI). Linear Resolution 0.0156 Pa (0.000156 Mb, 0.00000023 PSI). Linear Frequency Response Varies with sample rate, from 2 to 250 Hz at 1024 samples/s. Linear Accuracy Conforms with ISEE Performance Specifications for Blasting Seismographs. A-Weighting Range 66 to 134 dba. A-Weighting Resolution 0.02 dba. Timer Allows an instrument to be active only during selected times on a daily basis. Communication USB Serial baud rates from 1200 to 230400. External Data Storage Write to USB drive. System Log A log is kept in memory to track the active monitoring periods and whenever important setup changes are made. Waveform Modes Waveform, Manual, Auto, Snapshot, Waveform/Histogram. Sample Rate 1024, 2048 and 4096 [rates of 8192, 16384 and 65536 (for single channel are under development.} Duration 1 to 60 seconds at 1024, 2048 or 4096 sample rate. Pre-Trigger 1 second at 1024 sample rate. The pre-trigger time decreases proportional to the sample rate. Minimum Trigger Levels Seismic - 0.127 mm/sec (0.005 in/s). Acoustic - 88 dbl, 68 dba. Records Stored Varies depending on the sample rate and duration. The unit can store well over 1000 records at a 1024 sample rate and 5 second duration. Downtime Between Events There is no downtime or data loss between events. Dynamic Sensor Test A dynamic sensor test is performed at the end of every event. This test will appear in the pre-trigger of continuous events. Histogram Modes Histogram and Histogram/Waveform. Sample Interval 1, 10, 20, 30, 40, 50 or 60 seconds. Data Stored Channel peaks and their frequencies, also the vector sum. Records Stored Histogram data will vary depending on the sample interval. The unit can store approximately 100 eight hour days at a 10 second interval. Dynamic Sensor Test A dynamic sensor test is performed at the beginning & end of every histogram.

Mini-Seis - The Best Value The Mini-Seis is the very definition of a great blast monitoring seismograph at an affordable price. It is ideal for all kinds of blast vibration monitoring and for most continuous vibration monitoring in bar graph mode. Rugged, reliable and very easy to use, the Mini-Seis sets the standard for value in a seismograph. If you need a low-cost seismograph that is accurate, rugged and reliable, the Mini-Seis is the perfect choice. Mini-Seis Quick Features & Options Key Features Lower maintenance & calibration costs. Rugged construction & shielded against RF interference. Keypad & display for easy field setup & data review. External seismic package & microphone interchangeable between units of like sensitivity. Selectable seismic & acoustic recording range & trigger level, sample rate & record duration. Rechargeable internal battery. Ability to use AC or DC power for long term monitoring. Wave form (self-trigger & manual-trigger) & continuous bar graph (histogram) modes. Sophisticated, non-loss data compression results in small record sizes & fast data transfer. Available Options Transducer Sensitivity - The standard transducer sensitivity is termed a 2G. Recording levels can range from 0.005 ips (0.127 mmps) to 10.24 ips (260 mmps). We also offer X1, X4 and X8 geophone gains, which modify the standard X2 gain proportionally. These are standard options but we can also do custom gains based on specific needs. Microphone Sensitivity - The standard microphone is limited to 148 db. We also offer a standard option 160 db microphone. If necessary, we can supply microphones capable of recording up to 5 or even 10 psi (185 to 190 db).

VanguardNewYork.com Mini-Seis Technical Specifications - More specifications at VanguardNewYork.com Data Recorded Frequency Response Seismic Sensors Waveform Summary Data One (1) acoustic and three (3) seismic channels. Mini-Seis: 2 to 500 Hz. (-3 db. points) at 2048 samples per second. Three component mounted velocity geophones or accelerometers,depending on the ordered recording ranges. The full waveform signature is stored in solid state memory for up to 340 events. Summarized data include the event time, date, battery voltage, peak measurements, unit serial number and frequencies. The summarized data are stored in solid state memory for the last 341 events. From 2048 samples per sec. per channel down to 32 samples per sec. per channel. Sample Rate Seismic Recording Ranges Standard (x2) 0.005 IPS to 2.5 IPS (0.125 to 64 MMPS) 1.1 IPS to 5.0 IPS (0.25 to 127 MMPS) 1.2 IPS to 10.0 IPS (0.50 to 254 MMPS) Optional (x1 - accel.) 1.1 IPS to 5.0 IPS (0.25 to 127 MMPS) 1.2 IPS to 10.0 IPS (0.50 to 254 MMPS) 1.4 IPS to 20.0 IPS (1.00 to 508 MMPS) Optional (x4) 0.0025 IPS to 1.2 IPS (0.063 to 30.5 MMPS) 1.5 IPS to 2.5 IPS (0.125 to 64 MMPS) 0.01 IPS to 5.0 IPS (0.25 to 127 MMPS) Optional (x8) 0.0013 IPS to 0.6 IPS (0.033 to 15.2 MMPS) 0.0025 IPS to 1.2 IPS (0.063 to 30.5 MMPS) 0.005 IPS to 2.5 IPS (0.125 to 64 MMPS) Acoustic Ranges 0.02 to 2.56 millibars (100 to 142 db) 0.04 to 5.12 millibars (106 to 148 db). Trigger Levels Seismic 2.5 IPS Range - 0.01 to 0.57 IPS (0.25 to 14.5 MMPS). 5.0 IPS Range - 0.02 to 1.14 IPS (0.5 to 29 MMPS). 10.0 IPS Range - 0.04 to 2.28 IPS (1.0 to 58 MMPS). Seismic trigger sensitivities are proportionally modified by optional gains. Acoustic 106 to 142 db or 112 to 148 db. Manual Trigger Allows triggering from the keyboard or by an external input. One unit may be used to trigger additional instruments. Record Duration From 1 to 6 seconds at a sample rate of 2048 samples per second. At lower sample rates, the duration is automatically increased proportional to the amount of decrease in the sample rate. Cycle Time At 1024 samples per second, up to 12 seconds of data can be taken with only 50 milliseconds between events. After 12 seconds of data are stored, another event cannot be taken until the previous data have been processed. Processing requires about 3 seconds per second of recording time. Records Stored Up to 341 typical coal mine or quarry blast events. RS232 Serial Port Data can be downloaded and setup commands can be uploaded directly by computer or remotely by modem. Baud Rate From 1200 to 38.4K.

Product Pricing Sales Pricing Mini-Seis III The Next Generation $5,275.00 Mini-Seis The Best Value $3,975.00

Because of our unique business structure, no project is too large or too small for Vanguard. Ingenuity and an eye for recognizing potential issues before they arise make Vanguard the obvious choice for your project. 1A Winston Way New Milford, CT 06776 P: 845-803-0295 VanguardNewYork.com