U GENIUS. Gel imaging at a touch

Similar documents
U:GENIUS S Y N G E N E. Gel imaging at a touch A DIVISION OF THE SYNOPTICS GROUP

Gel imaging at a touch S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP

INGENIUS 3 LOW COST, HIGH PERFORMANCE GEL DOCUMENTATION AND ANALYSIS

INGENIUS 3. Low cost, high performance gel documentation and analysis

T:GENIUS GEL IMAGING AT A TOUCH

GEL IMAGING AT A TOUCH

bioteknika T:GENIUS GEL IMAGING AT A TOUCH

Gel Documentation and Analysis the way you want it S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP

G BOX. Gel Documentation and Analysis Automated imaging

Redefining Gel and Blot Imaging

Contents Chapter One- Introduction

Redefining gel and blot imaging

MULTI FLUORESCENCE AND CHEMILUMINESCENCE IMAGING SYSTEM DETECTION WITH A DIFFERENCE

DEDICATED CHEMILUMINESCENCE IMAGING SYSTEM DELIVERS SIMPLICITY AND SENSITIVITY

MULTI FLUORESCENCE AND CHEMILUMINESCENCE IMAGING SYSTEMS REAL IMAGING FOR REAL SCIENTISTS

Gel Documentation and Analysis Automated imaging

GEL DOCUMENTATION AND ANALYSIS Automated imaging

2D Protein Gel Image Capture and Analysis

BioSpectrum Imaging System

Ordering Information & Specifications. VisionWorksLS Capabilities. Image Analysis Capabilities

Automated Imaging Technology to Simplify Your Workflow!

BioSpectrum Imaging System

FluorChem M MultiFluor System

BioSpectrum Imaging System

F U S I O N F X 7 S A L E S & M A R K E T I N G T O O L S

VisiDoc-It Imaging System

TRANSILLUMINATORS. FirstLight Ò Uniform UV Illuminator. Benchtop UV Transilluminators. 3UV TM Benchtop Models

Automated Colony Counting and Zone Sizing

BioDoc-It 2 Imaging System

Imagers- Molecular, Cell Standard Operating Procedures

AlphaImager IS-2200 For Windows 2000/XP

Seishi IKAMI* Takashi KOBAYASHI** Yasutake TANAKA* and Akira YAMAGUCHI* Abstract. 2. System configuration. 1. Introduction

BIO IMAGING. Choose your application of STELLA 2000 STELLA 3200 STELLA BIO Image. light source. light source. light source.

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP

ChemiDoc-It Imaging System

Biomolecular imaging

FastGene FAS-Digi PRO

FUSION SOLO S CHEMILUMINESCENCE & OPTIONAL FLUORESCENCE IMAGING WESTERN BLOT IMAGING

Transilluminators: UV light, White light (WE-LED), Blue Light (BE-LED) Made in Germany Made by Herolab NEW

BIOMOLECUL AR IMAGING CHEMILUMINESCENCE BIOLUMINESCENCE FLUORESCENCE MULTIPLEXING VISIBLE IMAGING

Image Capture TOTALLAB

How is the Digital Image Generated? Image Acquisition Devices

VWR Gel Documentation System Smart3/Smart3-EZ

ibox Spectra 310C Small Animal Imaging System

C A P A B I L I T I E S 4 I The range 6 I Performance and innovations 8 I Advanced technologies 10 I Applications 12 I Software

S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP. G:BOX User Guide

FastGene FAS-V Imaging System. Catalogue Number GP-FAS-V

GelStudio SA 2 ChemStudio SA 2 Imagers

S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP. PXi / PXi Touch User Guide

Using the Nikon TE2000 Inverted Microscope

SmartDoc 2.0 E5001-SDB Instruction Manual

Clare Chemical Research. Dark Reader

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

VWR Gel Documentation System Imager Range User Guide

Chemiluminescence- and Fluorescence-Imager Celvin S

New Benchmark of Molecular Image Software Package

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software

BioSpectrum Imaging System

Stereo Viewing Systems

DNR reserves the right, without prior notice or liability, to make changes in equipment design or specifications.

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

KODAK Image Station 4000R

GE Healthcare. ImageQuant LAS User Manual

A True Innovation in Non-Destructive Testing System FUJIFILM COMPUTED RADIOGRAPHY. Series 4 CR

ibox Spectra Small Animal Imaging System

FluorChem M System User Guide

AE-6981 VOL MAS. Light-Capture. with CS Analyzer 3. for Chemiluminescence

Film2USB Converter. Quick Start Guide & User s Manual. Model Number F2USB-05

Gel Doc XR+ and ChemiDoc XRS+ Imaging Systems with Image Lab Software

ImageQuant LAS 4000 mini

Color Matching Beginning with the Basics. EIZO's Guide to enjoyment. a further. of digital. I see. photography

FluorChem FC2/HD2 USER GUIDE

Please read and retain these instructions for future reference. PLEASE SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE.

Melting point range. A complete range of melting points to accomodate all users

Contents. Image Quality Megapixel CCD sensors. Higher resolution produces greater detail

MOLECULAr IMAGING CHEMILUMINESCENCE FLUOrESCENCE ANALySIS SOFTWArE

Fluor-S MAX MultiImager

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

1 Detection of Latent Fingerprints. 2 The Latentmaster System. 3 The Latentmaster Software. 4 Latentmaster Components

See what you need to see, and see it anywhere.

DKS1530 The perfect evolution of a minilab

FastGene Blue White LED Tab Catalogue Number FG-12

Dark Reader Transilluminators

DKS1550 High performance digital minilab

MS300 digital microfilm scanner. Switch to affordable, efficient digital microfilm scanning

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

Featuring Technology Product Range Guide 2014

Colony Counting with powerful analysis software

Smart Solutions - Infinite Possibilities KIP 70 SERIES

The ideal K-12 science microscope solution. User Guide. for use with the Nova5000

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

CAMAG TLC VISUALIZER 2

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Operational Qualification Protocol (OQ)

COOLPIX " Scene Modes. Zoom-Nikkor Lens. Effective Megapixels. Macro Mode OPTICAL

Product Range Guide. All Purpose Office. Photo 2010/2011. Superior Performance across the Range

QUANTUM ST4. User manual 1/ /2009 index f

What you can do with the Image Data Converter

Colony Imaging with powerful Analysis Software

Ideal for display mura (nonuniformity) evaluation and inspection on smartphones and tablet PCs.

September CoroCAM 6D. Camera Operation Training. Copyright 2012

Transcription:

U GENIUS 3 Gel imaging at a touch

U:GENIUS 3 Simply Genius. Designed to make your gel imaging simple, quick and easy. No set up, no external computer - just a complete imaging system for all your 1D needs. A smooth and intuitive touch screen ensures that anyone can use a U:Genius 3 with virtually no previous experience of gel imaging. U:Genius 3 - from switch-on to perfect image at a touch.

Use the large colour touch screen to navigate your way through the functions of U:Genius 3. The icon driven menu is both intuitive and easily understood. All functions from image capture, manipulation, printing to archiving are at the touch of a button.

U:Genius 3 applications DNA With a U:Genius 3 you can use the UV transilluminator to capture images of DNA gels stained with Ethidium Bromide Blue light The blue light LED transilluminator allows you to view some fluorescent stains with better clarity and with less gel damage Examples: GFP, SYBR Green, SYBR Gold, SYBR Safe, SYPRO Ruby, Safe View, Flamingo, Pro-Q Diamond, Pro-Q Emerald, Fluorescein, Rhodamine Red TM, Texas Red, Deep Purple TM and others Visible light With the transmitted visible light converter, a U:Genius 3 can be used to view gels which have been stained with silver stain and Coomassie blue. You can also view tissues, slides and films AutoRads The U:Genius 3 features a mega resolution camera which is ideal for capturing images requiring high detail. This is especially true when looking for separation between bands and spots. Capturing high quality images of Autorads is one of the strengths of the U:Genius 3 Spot blots Capturing and analysing spot blots is another very simple application for U:Genius 3 These are just some of the applications that can be used with U:Genius 3. The Syngene Applications & Support Department is always ready to discuss your particular application needs and how they can be imaged using the U:Genius 3. The Syngene website contains further technical notes and FAQ's covering the use of all Syngene gel documentation systems. Further details can be found at www.syngene.com

U:Genius 3 system LIVE IMAGE capture the image you see with a single touch AUTO EXPOSURE automatic exposure control lets U:Genius 3 give you the perfect image EXPOSURE CONTROL manually set the exposure SATURATION DETECTION see which areas of the image are over exposed NEUTRAL FIELDING correction of any uneven background illumination EDR Syngene s patented extended dynamic range function SAVE/LOAD save or load image to USB memory stick, internal hard drive or use the networking capabilities ZOOM zoom image to view areas in greater detail PRINT send image to attached printer ROTATE rotate image by degrees - no more skewed images SHARPEN add sharpening to enhance band edges SMOOTH even out background noise when viewing INVERT view the reverse image ANNOTATION add annotation (text,shapes, lines) to images CAMERA Superb 3 million pixel resolution LENS Superior zoom lens for exceptional image quality FILTER DRAWER Use a range of filters for extensive choice of applications* INTEGRAL COMPUTER High specification integral computer featuring embedded Windows XP operating system: network USB ports hard drive TOUCH SCREEN Large colour LCD screen USB Stores images on a USB memory stick SAFETY SWITCH Protects from accidental UV exposure when opening door INTERNAL WHITE LIGHT For sample positioning and focusing TRANSILLUMINATORS (OPTIONAL) For UV or blue light UV transilluminator slides in and out of darkroom Blue LED light (UltraSlim-LED) sits on a slide in and out tray Visible light converter SLIDING DOOR Space saving sliding door *see the on-line Syngene database for details

U:Genius 3 features & benefits Features Compact darkroom with sliding door - 46.5(w) x 51.0(h) x 39.0(d) cms Can use a range of transilluminators (20 x 20 cm) No compromise on resolution - 3 million pixels Easy to access filter drawer accepts interchangeable filters Integral computer Colour touch screen Image enhancements and annotations Save images in TIFF, BMP or JPEG format Benefits Small footprint taking up minimal laboratory bench space Versatile - not restricted to using only small gels Exceptional resolution for high quality images Capable of viewing a wide range of different fluorophores Full networking capability, USB ports and an internal hard disk for image storage Full intuitive touch control of all functions with large image view Total control over image quality Simple to download to any PC or Mac

Superior gel illumination UltraSlim Blue-LED option uses a high intensity LED array which can illuminate a range of dyes including GelRed, GelGreen, SYBR Safe, EtBr and the new UltraSafe blue dye. UltraSlim-LED provides a uniform and bright excitation across gels up to 12 x 10cm. UltraSlim-LED specification The unit is compact and slimline and has an array of LEDs which illuminate samples from the side, providing low signal to noise ratio (S/N). A built-in filter/lid provides the optimum viewing conditions and is ideal for band cutting. Dimension (mm) Gel size (mm) Wavelength (nm) Power Weight 210(d) x 210(w) x 30(h) 100 x 120 470nm DC 24v 0.65A 1.3kg UltraSlim Blue-LED is used instead of the UV transilluminator and is positioned on a sliding tray.

U:GENIUS 3 U:Genius 3 specification Simply Genius. Designed to make your gel imaging simple, quick and easy. No set up, no external computer - just a complete imaging system for all your 1D needs. Camera Sensor Resolution Bit depth Greyscales Dynamic range Lens Viewing area Illumination Slim UV transilluminator 20 x 20cm UltraSlim Blue-LED transilluminator 10 x 12cm Visible light converter White Epi overhead Software Image capture GeneTools image analysis GeneDirectory U:Genius 3 1/3 inch 3 million pixels 12/16 bit (extended) 0-65,536 3.6/4.8 (extended) Manual zoom 6.5 39, F1.4 20 x 20cm Option Option Option Yes Yes Yes Option

Please refer to www.syngene.com for all ordering information Syngene Europe and International Headquarters: Beacon House Nuffield Road Cambridge CB4 1TF UK Tel: +44 (0)1223 727123 Fax: +44 (0)1223 727101 email: sales@syngene.com Syngene USA Headquarters: 5108 Pegasus Court Suite M Frederick MD 21704 USA Tel: 800-686-4407/301-662-2863 Fax: 301-631-3977 email: ussales@syngene.com Website: www.syngene.com G.0050.03.12 All trademarks acknowledged

Over 75,000 scientists world-wide in pharmaceutical and biotech companies, as well as academic and government institutions, have chosen Syngene as their expert imaging partner. If you d like to find out why, please contact us or one of our dealers for more information and a demonstration of the revolutionary U:Genius 3 Please refer to www.syngene.com for all ordering information Syngene Europe and International Headquarters: Beacon House Nuffield Road Cambridge CB4 1TF UK Tel: +44 (0)1223 727123 Fax: +44 (0)1223 727101 email: sales@syngene.com Syngene USA Headquarters: 5108 Pegasus Court Suite M Frederick MD 21704 USA Tel: 800-686-4407/301-662-2863 Fax: 301-631-3977 email: ussales@syngene.com Website: www.syngene.com G.0050.03.12 All trademarks acknowledged