INGENIUS 3 LOW COST, HIGH PERFORMANCE GEL DOCUMENTATION AND ANALYSIS

Similar documents
INGENIUS 3. Low cost, high performance gel documentation and analysis

U GENIUS. Gel imaging at a touch

GEL IMAGING AT A TOUCH

T:GENIUS GEL IMAGING AT A TOUCH

U:GENIUS S Y N G E N E. Gel imaging at a touch A DIVISION OF THE SYNOPTICS GROUP

Gel imaging at a touch S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP

G BOX. Gel Documentation and Analysis Automated imaging

bioteknika T:GENIUS GEL IMAGING AT A TOUCH

Redefining Gel and Blot Imaging

Gel Documentation and Analysis the way you want it S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP

Redefining gel and blot imaging

MULTI FLUORESCENCE AND CHEMILUMINESCENCE IMAGING SYSTEM DETECTION WITH A DIFFERENCE

DEDICATED CHEMILUMINESCENCE IMAGING SYSTEM DELIVERS SIMPLICITY AND SENSITIVITY

Contents Chapter One- Introduction

Gel Documentation and Analysis Automated imaging

GEL DOCUMENTATION AND ANALYSIS Automated imaging

MULTI FLUORESCENCE AND CHEMILUMINESCENCE IMAGING SYSTEMS REAL IMAGING FOR REAL SCIENTISTS

Ordering Information & Specifications. VisionWorksLS Capabilities. Image Analysis Capabilities

Automated Imaging Technology to Simplify Your Workflow!

BioSpectrum Imaging System

BioSpectrum Imaging System

2D Protein Gel Image Capture and Analysis

FluorChem M MultiFluor System

BioSpectrum Imaging System

FUSION SOLO S CHEMILUMINESCENCE & OPTIONAL FLUORESCENCE IMAGING WESTERN BLOT IMAGING

BIO IMAGING. Choose your application of STELLA 2000 STELLA 3200 STELLA BIO Image. light source. light source. light source.

ChemiDoc-It Imaging System

TRANSILLUMINATORS. FirstLight Ò Uniform UV Illuminator. Benchtop UV Transilluminators. 3UV TM Benchtop Models

Imagers- Molecular, Cell Standard Operating Procedures

Seishi IKAMI* Takashi KOBAYASHI** Yasutake TANAKA* and Akira YAMAGUCHI* Abstract. 2. System configuration. 1. Introduction

Transilluminators: UV light, White light (WE-LED), Blue Light (BE-LED) Made in Germany Made by Herolab NEW

F U S I O N F X 7 S A L E S & M A R K E T I N G T O O L S

Chemiluminescence- and Fluorescence-Imager Celvin S

Biomolecular imaging

Automated Colony Counting and Zone Sizing

Image Capture TOTALLAB

BIOMOLECUL AR IMAGING CHEMILUMINESCENCE BIOLUMINESCENCE FLUORESCENCE MULTIPLEXING VISIBLE IMAGING

C A P A B I L I T I E S 4 I The range 6 I Performance and innovations 8 I Advanced technologies 10 I Applications 12 I Software

How is the Digital Image Generated? Image Acquisition Devices

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

Gel Doc XR+ and ChemiDoc XRS+ Imaging Systems with Image Lab Software

CAMAG TLC VISUALIZER 2

High-sensitivity. optical molecular imaging and high-resolution digital X-ray. In-Vivo Imaging Systems

AlphaImager IS-2200 For Windows 2000/XP

S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP. G:BOX User Guide

New Benchmark of Molecular Image Software Package

VisiDoc-It Imaging System

S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP. PXi / PXi Touch User Guide

SmartDoc 2.0 E5001-SDB Instruction Manual

BioSpectrum Imaging System

Colony Counting with powerful analysis software

Y N C R O S C O P Y A DIVISION OF THE SYNOPTICS GROUP

Colony Imaging with powerful Analysis Software

ibox Spectra 310C Small Animal Imaging System

MOLECULAr IMAGING CHEMILUMINESCENCE FLUOrESCENCE ANALySIS SOFTWArE

FluorChem M System User Guide

Colony Counting with powerful analysis software

FastGene Blue White LED Tab Catalogue Number FG-12

Characterization Microscope Nikon LV150

GE Healthcare. ImageQuant LAS User Manual

DNR reserves the right, without prior notice or liability, to make changes in equipment design or specifications.

ibox Spectra Small Animal Imaging System

BioDoc-It 2 Imaging System

OLYMPUS Digital Cameras for Materials Science Applications: Get the Best out of Your Microscope

ODYSSEY Fc IMAGING SYSTEM

VWR Gel Documentation System Smart3/Smart3-EZ

VWR Gel Documentation System Imager Range User Guide

FluorChem FC2/HD2 USER GUIDE

FastGene FAS-V Imaging System. Catalogue Number GP-FAS-V

ImageQuant LAS 4000 mini

KODAK Image Station 4000R

Using the Nikon TE2000 Inverted Microscope

Fluor-S MAX MultiImager

AE-6981 VOL MAS. Light-Capture. with CS Analyzer 3. for Chemiluminescence

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software

GelStudio SA 2 ChemStudio SA 2 Imagers

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Innovative measurement instruments from

The World s Most Trusted Name In Color Quality. HunterLab

Thermo Scientific SPECTRONIC 200 Education

Camera Test Protocol. Introduction TABLE OF CONTENTS. Camera Test Protocol Technical Note Technical Note

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

Colony Imaging with powerful Analysis Software

foster + freeman Advanced fingerprint capture & enhancement

Clare Chemical Research. Dark Reader

Opterra II Multipoint Scanning Confocal Microscope. Innovation with Integrity

Ensure Your Future. with Reproducible Data

FastGene FAS-Digi PRO

Camera Overview. Olympus Digital Cameras for Materials Science Applications: For Clear and Precise Image Analysis. Digital Cameras for Microscopy

Passport photographs. Head Position & Background for Passport Photo

Products - Microarray Scanners - Laser Scanners - InnoScan 900 Series and MAPIX Software

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Operational Qualification Protocol (OQ)

Thermo Scientific SPECTRONIC 200

CLx QUANTITATIVE WESTERN BLOTS HIGH SENSITIVITY WIDE, LINEAR DYNAMIC RANGE NO FILM OR DARKROOM WIDE RANGE OF APPLICATIONS

Proudly serving laboratories worldwide since 1979 SPECIFICATIONS

1 Detection of Latent Fingerprints. 2 The Latentmaster System. 3 The Latentmaster Software. 4 Latentmaster Components

Technical Benefits of the

Gel Scanner User Guide

Camera Overview. Digital Microscope Cameras for Material Science: Clear Images, Precise Analysis. Digital Cameras for Microscopy

QUANTUM ST4. User manual 1/ /2009 index f

Transcription:

INGENIUS 3 LOW COST, HIGH PERFORMANCE GEL DOCUMENTATION AND ANALYSIS

The InGenius 3 uses a high performance 3m pixel camera. The darkroom assembly is easily connected to a PC. GeneSys image acquisition software quickly and easily enables images to be captured, archived and edited if required.

GENESYS IMAGE ACQUISITION SOFTWARE INGENIUS 3 APPLICATIONS GeneSys software is intuitive and ensures that perfect images are captured every time. An image browser facility allows you to view stored images. Previously saved protocol configurations can be easily accessed. The user need only select the sample format, sample type and matrix type for the InGenius 3 system to configure itself to capture the best image. The type of dye being used can be selected from the extensive internal database. When using automatic capture the system will advise the optimum imaging conditions. Captured images are displayed in the main part of the screen, while previously captured images are displayed in an image pool as a series of thumbnails. A full range of editing tools are available to annotate, manipulate, enhance, save and print the image. DNA With InGenius 3 you can use the UV transilluminator to capture images of DNA gels stained with Ethidium Bromide, SYBR dyes and many other fluorophores AutoRads InGenius 3 features a mega resolution camera which is ideal for capturing images requiring high detail. This is especially true when looking for separation between bands and spots. Capturing high quality images of Autorads is one of the strengths of InGenius 3 Visible light With the transmitted visible light converter, InGenius 3 can be used to view gels which have been stained with silver stain and Coomassie blue. You can also view tissues, slides and films Blue light The blue light LED transilluminator allows you to view some fluorescent stains with better clarity and with less damage to DNA Spot blots Capturing and analysing spot blots is another very simple application for InGenius 3 and GeneTools software The user can have full manual control of all functions. These are just some of the applications that can be used with InGenius 3. The Syngene Applications & Support Department is always ready to discuss your particular application needs and how they can be imaged using the InGenius 3. The Syngene website contains further technical notes and FAQ s covering the use of all Syngene gel documentation systems. Further details can be found at www.syngene.com

INGENIUS 3 SYSTEM CAPTURE, STORE & MANIPULATE IMAGES WITH GENESYS Image acquisition with a single button Auto exposure/manual exposure/series capture Extended dynamic range up to 65,536 grey levels Neutral fielding for correction of uneven background illumination Toolbox - annotation/ sharpening/inverting Saturation control - see which areas of the image are over-exposed ANALYSE, DOCUMENT & QUANTIFY GELS WITH GENETOOLS 1D analysis at the click of a button MW/BP calibrations Quantity calibrations Spot blot/colony plate analysis Band matching functions CAMERA CCD digital camera 3m pixels USB2 connection LENS Superior zoom lens for exceptional image quality FILTER DRAWER Use a range of filters for extensive choice of applications* SAFETY SWITCH Protects from accidental UV exposure when opening door INTERNAL WHITE LIGHT For sample positioning and focusing TRANSILLUMINATORS (OPTIONAL) For UV or blue light UV transilluminator slides in and out of darkroom Blue LED light (UltraSlim-LED) - sits on a slide in and out tray Visible light converter SLIDING DOOR Space saving sliding door *see the on-line Syngene database for details

SUPERIOR GEL ILLUMINATION UltraSlim Blue-LED option uses a high intensity LED array which can illuminate a range of dyes including GelRed, GelGreen, SYBR Safe, EtBr and the new UltraSafe blue dye. UltraSlim-LED provides a uniform and bright excitation across gels up to 12 x 10 cm. The unit is compact and slimline and has an array of LEDs which illuminate samples from the side, providing low signal to noise ratio (S/N). A built-in filter/lid provides the optimum viewing conditions and is ideal for band cutting. UltraSlim Blue-LED is used instead of the UV transilluminator and is positioned on a sliding tray. UltraSlim-LED specification Dimension (mm) Gel size (mm) Wavelength Power Weight 210(d) x 210(w) x 30(h) 100 x 120 470nm DC 24v 0.65A 1.3kg

INGENIUS 3 When simplicity and budget matter. The InGenius 3 gel documentation and analysis system is compact, easy to use and offers an affordable route to gel capture and analysis. Using many of the features found on the higher specification Syngene products, the InGenius 3 makes a simple but sophisticated system for any laboratory.

Features Compact darkroom with sliding door - 40.0(w) x 30.0(h) x 37.5(d) cms 3 million pixel camera Benefits Small footprint taking up minimal laboratory bench space Good quality images 12/16 bit images (0-65,535 grey levels dynamic range) Filter drawer UV to visible light converter screen (option) GeneTools analysis software Connect to any PC Transilluminators (option) Precise quantitation Capable of viewing a wide range of different fluorophores Easy imaging of protein gels, autoradiographs and colony plates Saves time by automating analysis of gels, colony plates & blots Use a computer of your choice Choice of UV or blue light INGENIUS 3 SPECIFICATION INGENIUS 3 Camera Sensor Resolution Bit depth Greyscales Dynamic range Lens Viewing area Illumination Slim UV transilluminator 20 x 20 cm UltraSlim Blue-LED transilluminator 10 x 12 cm Visible light converter White Epi overhead Software GeneSys image capture GeneTools image analysis GeneDirectory 1/3 inch 3 million pixels 12/16 bit (extended) 0-65,536 3.6/4.8 (extended) Manual zoom, 6.5 39, F1.4 20 x 20 cm Option Option Option Yes Yes Yes Option

Over 75,000 scientists world-wide in pharmaceutical and biotech companies, as well as academic and government institutions, have chosen Syngene as their expert imaging partner. If you d like to find out why, please contact us or one of our dealers for more information and a demonstration of the revolutionary InGenius 3 Please refer to www.syngene.com for all ordering information Syngene Europe and International Headquarters: Beacon House Nuffield Road Cambridge CB4 1TF UK Tel: +44 (0)1223 727123 Fax: +44 (0)1223 727101 email: sales@syngene.com Syngene USA Headquarters: 5103 Pegasus Court Suite L Frederick MD 21704 USA Tel: 800-686-4407/301-662-2863 Fax: 301-631-3977 email: ussales@syngene.com Website: www.syngene.com G0056.06.15 All trademarks acknowledged