SmartDoc 2.0 E5001-SDB Instruction Manual

Similar documents
Transilluminators: UV light, White light (WE-LED), Blue Light (BE-LED) Made in Germany Made by Herolab NEW

FastGene Blue White LED Tab Catalogue Number FG-12

T:GENIUS GEL IMAGING AT A TOUCH

Gel Doc XR+ and ChemiDoc XRS+ Imaging Systems with Image Lab Software

OPERATOR S MANUAL. Fixed-Intensity Ultraviolet Transilluminators SPECTRONICS CORPORATION

Diode Pointer Quick Start Guide

INGENIUS 3 LOW COST, HIGH PERFORMANCE GEL DOCUMENTATION AND ANALYSIS

INGENIUS 3. Low cost, high performance gel documentation and analysis

bioteknika T:GENIUS GEL IMAGING AT A TOUCH

User Manual. Digital Compound Binocular LED Microscope. MicroscopeNet.com

U GENIUS. Gel imaging at a touch

Clare Chemical Research. Dark Reader

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications.

TECHNICAL INFORMATION Hungarian Red Catalog Nos. LV503, LV5031

Imagers- Molecular, Cell Standard Operating Procedures

Dark Reader Transilluminators

SER: Biological Stains Visualization with Alternate Light Sources

USER MANUAL FOR VISIBLE SPECTROPHOTOMETER

VALENCIA CORNER DOOR WITH RETURN

PharosFX Molecular Imager System. Hardware Instruction Manual

FluorChem M MultiFluor System

FastGene FAS-Digi PRO

Seishi IKAMI* Takashi KOBAYASHI** Yasutake TANAKA* and Akira YAMAGUCHI* Abstract. 2. System configuration. 1. Introduction

Light Microscopy. Upon completion of this lecture, the student should be able to:

VALENCIA RONDO DOOR WITH RETURN

Protect Yourself. Electromagnetic Spectrum (Enlargement Of Ultraviolet Region)

Riverside. Windward Bay EntertaInment Wall System Assembly Instructions. Made In Viet Nam. Right Pier. Bridge & Back Panel.

Diode Pointer Quick Start Guide

GEL IMAGING AT A TOUCH

FastGene FAS-V Imaging System. Catalogue Number GP-FAS-V

Firestar v Series air cooled laser & Flyer 3D System Quick Start Guide

Directions for Use. Veinlite A. TransLite, LLC.

VisiDoc-It Imaging System

TECHNICAL INFORMATION GoldPanther Forensic Light Source Kit (Patent Pending) Cat. Nos. FAL2000, FAL

ibox Spectra Small Animal Imaging System

Using a Compound Light Microscope

Microscopy. The dichroic mirror is an important component of the fluorescent scope: it reflects blue light while transmitting green light.

3/4 turn pot Intensity control of 10% to 100% Clockwise increases intensity Analog Intensity

Seapoint Rhodamine Fluorometer

Submersible Microscope User Guide

LINEAR LIGHT. LED Strobe Indicator ON = Light Active Green Indicator LED

EXAMINER+ Manual V.1. ARROWHEAD FORENSICS Strang Line Road Lenexa, Kansas PHONE FAX

Spectroscopy Application: Using Raman Spectroscopy to Detect Art Forgeries Detecting art forgeries using Raman spectroscopy

Centurion Laser Shower

G BOX. Gel Documentation and Analysis Automated imaging

TRANSILLUMINATORS. FirstLight Ò Uniform UV Illuminator. Benchtop UV Transilluminators. 3UV TM Benchtop Models

Firestar f201 laser & Flyer 3D System Quick Start Guide

Allegro Home Office Assembly Instructions. Tipping Restraint. Bun Foot W/ Leveler. 4 pcs.

FLUOLED 21 the plug-and- play microscope for TB (Mycobacterium tuberculosis), based on Olympus CX 21 microscope

INSTRUCTION MANUAL. Force Transducer Output Tube Repair Kit

Installing the detector filter assembly (G )

Redefining Gel and Blot Imaging

User guide ProHead Plus

Home Lab 13 Interference

Photo-Documentation of Ultraviolet Radiation Induced Visible Fluorescence on Daguerreotypes

rainbow ReSposable Pulse CO-Oximeter Sensor System Training Please see product s Directions for Use for more information 2012 Masimo Corporation

Neo Ultrasound Module Manual

Surprises with Light JoAnne Dombrowski

5. Carefully remove the printer from the lower boxed foam support and place it on a solid, level base where it will be used

KODAK EKTACHROME RADIANCE III Paper

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Operational Qualification Protocol (OQ)

LABORATORY / LIFE SCIENCES

Sarspec, Lda. - Rua Camilo Castelo Branco, 965 PQ Vila Nova de Gaia Phone:

User Manual. Trinocular Metallurgical Microscope. MicroscopeNet.com

Microbiology Laboratory 2

Pulstar p100/150 water cooled laser & Flyer 3D System Quick Start Guide

Biology 29 Cell Structure and Function Spring, 2009 Springer LABORATORY 1: THE LIGHT MICROSCOPE

HOLE CUTTER SHARPENER ASSEMBLY & SERVICE MANUAL

ECEN. Spectroscopy. Lab 8. copy. constituents HOMEWORK PR. Figure. 1. Layout of. of the

LXE Mounting Holes on Base. Warranty. Compliant IEC. Brightest linear light yet, delivering up to 100,000 lux in OverDrive mode

Firestar f201 laser & Flyer 3D System Quick Start Guide

Automated Imaging Technology to Simplify Your Workflow!

L A M I N AT E F L O O R C U T T E R OWNER S MANUAL

LXE300. Four Mounting Holes on Base. Compliant IEC. Warranty

ProHead. User s Guide

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

BioSpectrum Imaging System

INSTRUCTION MANUAL INF Fax: (503)

FD 1500 AutoSeal 12/07 OPERATOR MANUAL THIRD EDITION

INSTRUCTION MANUAL LCS TX

GelStudio SA 2 ChemStudio SA 2 Imagers

INSTALLATION INSTRUCTIONS FOR STANDING SHOWER CABIN OWNER'S MANUAL PLEASE READ INSTRUCTIONS BEFORE PROCEEDING Packing List. Door (pc) 2. Hinge (2pc) 3

Gel Scanner User Guide

Crime-lite 82S SPARES & ACCESSORIES. foster + freeman

Firework Colors. 5 g each of the following compounds (in finely powdered form):

Nuclear Associates

AutoSeal FD 2002/FD 2032 FE 2002/FE 2032 OPERATOR MANUAL FIRST EDITION

LA-T SERIES. Fast and reliable minute granular flaw detection in winding wires. Winding Wire Granular Flaw Detector PARTICULAR USE SENSORS

S Y N G E N E A DIVISION OF THE SYNOPTICS GROUP. G:BOX User Guide

Z-5652 plus Series. 2D Image Hands-Free Scanner

Nuclear Associates

Compound Light Microscopy. Microscopy. Things to remember... 1/22/2017. This is what we use in the laboratory

X-Mag. High-Magnification Workstation User s Guide Revision A

Chemiluminescence- and Fluorescence-Imager Celvin S

FORMAX. FD1500 AutoSeal OPERATOR MANUAL FIRST EDITION

PHOTO FRAME STRING LIGHTBOXES

LED GROW LIGHT-BYZ SERIES

Processing and. Photography. Printing

MICROSCOPY MICROSCOPE TERMINOLOGY

MADELINE METAL CHANDELIER

Transcription:

SmartDoc 2.0 E5001-SDB Instruction Manual Version 11.16 1

Table of Contents 1. Introduction 3 2. Warnings. 3 3. Unpacking.. 4 4. SmartDoc 2.0 Overview 4 5. Setting up the SmartDoc 2.0 5 6. Gel Viewing and Band Cutting.. 6 7. SmartDoc Photo Filters.. 6 8. Imaging with Smart Phone 7 9. Specifications.. 8 10. Accessories and Consumables 8 2

1. INTRODUCTION Congratulations on your purchase of a SmartDoc 2.0 System. This innovative and easy to use system allows visualization of stained nucleic acids in electrophoresis gels, and can also be used for capturing high quality photos with a smart phone camera. The blue light illumination system produces intense blue light at a wavelength that is ideal for excitation of most of the common, green stains available of the market, including SYBR strains and Accuris SmartGlow stains. The orange filter cover and orange photo filters included with the system are designed to absorb (block) the blue excitation light allowing only the fluorescing sample light to pass through for visualization by eye, or for capturing gel images using a smart phone or tablet with camera. To ensure proper operation and performance from your SmartDoc System, please read this manual in its entirety before use. 2. WARNINGS Read this manual in its entirety before operating the SmartDoc system, and keep the manual for future reference. CAUTION: Although the light emitted from the SmartDoc illumination base is within the visible spectrum, and does not pose the same hazards as UV light, this emitted blue light is very bright. It is not recommended to look directly at the blue light array (just as we recommend not to stare at the sun.) CAUTION: When working in a laboratory environment, it is always important to properly handle all reagents and chemicals. When using a cell phone for capturing gel images, it is very important not to contaminate the phone with any chemicals or reagents. Using use proper and common laboratory safety practices when working with reagents and gels stained with DNA dye. Always wear gloves, and always change gloves when switching from handling gels, or reagent to use of a cell phone, and vice versa. The SmartDoc System components should be cleaned periodically using mild soap and water or 10% bleach solution for decontamination. CAUTION: If using the SmartDoc enclosure on a UV transilluminator, always use caution to prevent exposure of the skin and eyes to UV light. If working on a UV transilluminator with a viewing surface larger 3

than the bottom of the SmartDoc housing, use the E5000-MAT UV Blocking Mat to block UV light from emitting around the edges of the SmartDoc. 3. UNPACKING NOTE: Always handle the SmartDoc system with care. Carefully remove the system and all accessories from the carton and remove any foam protective pieces. Check for shipping damage. In the event of shipping damage, a claim must be filed with the carrier. Check the contents of the package to make sure you have received all of the parts ordered: SmartDoc Imaging Enclosure parts: 1) Main enclosure hood, 2) extending adapter, and 3) top platform for smartphone. Orange Photo Filter Gel preparation and cutting surface Illumination base 12 VDC Power Supply with proper cord for local outlet type Any additional filters for UV (ordered separately) If any parts are damaged or missing, please immediately contact Benchmark Scientific Customer Service at 908-769-5555 or email info@benchmarkscientific.com. IMPORTANT: Save the carton and packing materials for storing and transporting the SmartDoc or returning it for any required servicing. 4. SmartDoc 2.0 Assembly, Overview of Parts Orange Photo filter Smart phone platform Removable extender (remove for close up imaging) Main Enclosure Hood 4

Power switch Blue light illumination base 12V DC input jack Gel Preparation and cutting surface AC/DC 12V Power Pack and Plug Cord 4. SETTING UP THE SMARTDOC Assemble the components of the SmartDoc 2.0 System as pictured in section 3 of the manual. Depending on the size of the gels to be imaged, or the desired detail of the image, the extender piece can be connected or removed. The top, smart phone platform piece connects either to the top of the extender or to the top of the main enclosure. These parts will snap together and pull apart with gentle pressure. Once the top platform, extender and main housing parts are assembled, these can be fit over the illumination base, which in turn fits over the gel preparation surface. Locate the SmartDoc near an electrical outlet. Plug the appropriate end of the power adapter cord into the 12V DC input jack on the illumination base. Plug one end of the power cord into the adapter box and the other end into a suitable outlet. Press the power switch to check operation of the lights. 5

Note: The SmartDoc uses a timing circuit, and the lights will automatically turn off after 5 minutes. This timer prevents excess heat from building up from the powerful LED lights. 5. GEL VIEWING AND BAND CUTTING The SmartDoc Illumination Base can be used with the orange filter cover for visualizing stained nucleic acids Gel Viewing separated on agarose or acylamide gels. Orange filter cover placed for gel viewing Orange filter cover set at an angle for gel access and band cutting 1. Set the gel preparation platform onto a level lab bench or table. 2. Glean the glass surface with alcohol or glass cleaner and allow to dry. 3. Carefully place a stained electrophoresis gel onto the square glass surface using care to eliminate bubbles under the gel. 4. Note: The maximum sized gel to fit onto the glass surface is 15x15cm, cut away any overhanging edges of the gel if required. 5. Place the blue illumination base over the gel preparation platform, taking care that it nests correctly into place. 6. SMARTDOC PHOTO FILTERS E5001-ORANGE (included) E5001-535 (optional) E5001-590 (optional) A photo filter is required to capture quality images with the SmartDoc 2.0 system. The orange photo filter, part E5001-ORANGE, is included with the system. This filter blocks the visible blue wavelengths coming from the illumination base or 6

other blue light transilluminators and allows through the emission wavelengths from fluorescing nucleic acid stains. Additional filters are available separately for the SmartDoc and are recommended for using the SmartDoc enclosure on a UV Transilluminator. These glass band pass filters block the UV light so the UV bulbs will not be seen in the images, and they also eliminate background wavelengths from the excitation source. E5001-590 band pass photo filter, 590nm, for imaging EtBR on UV transilluminator E5001-535 band pass photo filter, 535nm for imaging green stains on UV transilluminator Caution: Using the SmartDoc on a UV Transilluminator without an appropriate filter in place can cause eye or skin exposure to UV radiation. The SmartDoc filters effectively block harmful UV radiation, and should always be properly installed when using UV illumination. 7. GEL IMAGING WITH THE SMART DOC The SmartDoc 2.0 Illumination base produces visible blue light with peak output of 465nm for excitation of common nucleic acid stains. Compatible stains include Accuris SmartGlow PS (Pre Stain), SmartGlow LD (Loading Dye), SYBR Green I and II, SYBR Safe, SYBR Gold, Gel Star, Gel Green, and Green Glo. 1. Set the gel preparation platform onto a level lab bench or table. 2. Glean the glass surface with alcohol or glass cleaner and allow to dry. 3. Carefully place a stained electrophoresis gel onto the square glass surface using care to eliminate bubbles under the gel. 4. Note: The maximum sized gel to fit onto the glass surface is 15x15cm, cut away any overhanging edges of the gel if required. 5. Place the blue illumination base over the gel preparation platform, taking care that it nests correctly into place. 6. Place the SmartDoc imaging enclosure over the illumination base. 7. Insert the E5001-ORANGE filter into place on the top platform. The side with the Accuris logo should be facing up. 8. Place a smartphone face down onto the top platform, and align the camera lens with the filter. 9. Press the power switch on the illumination base to turn on the blue LEDs. 10. Select the Camera Mode on your Smart Phone, and turn off the flash setting. When properly positioned, the gel will be seen in the device s display screen. Focus as required. 11. If required, remove or insert the extender piece to maximize the image size 7

of the gel in the display. 12. A zoom function on the camera phone can be used to enlarge the gel image in the display, but this can decrease the resolution of the image. 8. SPECIFICATIONS: Maximum Gel Size: Excitation Source: Orange imaging filter: Orange viewing cover: Dimensions (WxDxH): Weight: Phone compatibility: Electrical*: 15 x 15 cm 230 high intensity blue LEDs, peak output 465nm Orange PMMA, 12mm aperture Orange PMMA, 18 x 18 cm 23 x 19 x 22 cm 0.9 kg iphone, Samsung, LG, HTC smartphones and tablets with camera 12VDC power supply Included. 9. ACCESSORIES AND CONSUMABLES Item No. Description E5001-ORANGE Orange photo filter E5001-590 band pass photo filter, 590nm, for imaging EtBR on UV transilluminator E5001-535 band pass photo filter, 535nm for imaging green stains on UV transilluminator E5001-OC Orange filter cover E4500-LD SmartGlow Loading Dye with Safe Green Stain, 1.0ml E4500-LD-S SmartGlow Loading Dye with Safe Green Stain, Sample, 20ul E4500-PS SmartGlow Safe Green Pre Stain, 1.0ml E4500-PS SmartGlow Safe Green Pre Stain, Sample, 40ul Copyright, 2016, Benchmark Scientific PO Box 709 Edison, NJ 08818 USA Phone: 908-769-5555 Email: info@accuris-usa.com www.benchmarkscientific.com / www.accuris-usa.com 8