BENG 186B Winter 2013 Final

Similar documents
BENG 186B Winter 2012 Quiz 3. March 7, NAME (Last, First): This quiz is closed book and closed note. You may use a calculator for algebra.

BENG 186B Principles of Bioinstrumentation. Week 7 Review. Solutions

Operational Amplifier BME 360 Lecture Notes Ying Sun

Lecture 4 Biopotential Amplifiers

Special-Purpose Operational Amplifier Circuits

Homework Assignment 07

E40M. Instrumentation Amps and Noise. M. Horowitz, J. Plummer, R. Howe 1

EE 3305 Lab I Revised July 18, 2003

Practice questions for BIOEN 316 Quiz 4 Solutions for questions from 2011 and 2012 are posted with their respective quizzes.

Biomedical Instrumentation (BME420 ) Chapter 6: Biopotential Amplifiers John G. Webster 4 th Edition

AD8232 EVALUATION BOARD DOCUMENTATION

CHAPTER 3. Instrumentation Amplifier (IA) Background. 3.1 Introduction. 3.2 Instrumentation Amplifier Architecture and Configurations

Homework Assignment 07

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

Concepts to be Reviewed

BIOMEDICAL INSTRUMENTATION PROBLEM SHEET 1

.SYSC 3203: Final Exam December 18, 2014 Carleton University, Systems and Computer Engineering

Instrumentation amplifier

ECE 363 FINAL (F16) 6 problems for 100 pts Problem #1: Fuel Pump Controller (18 pts)

Homework Assignment 03

IFB270 Advanced Electronic Circuits

EECS 145L Final Examination Solutions (Fall 2013)

Lesson number one. Operational Amplifier Basics

Lab E5: Filters and Complex Impedance

Precision, Low-Power and Low-Noise Op Amp with RRIO

1.8 V Low Power CMOS Rail-to-Rail Input/Output Operational Amplifier AD8515

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology

Section 4: Operational Amplifiers

ECEN Network Analysis Section 3. Laboratory Manual

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

LM146/LM346 Programmable Quad Operational Amplifiers

Low Cost, General Purpose High Speed JFET Amplifier AD825

LABORATORY 5 v3 OPERATIONAL AMPLIFIER

Ideal Op Amps. The Two Golden Rules for circuits with ideal op-amps*

ECE-342 Test 1: Sep 27, :00-8:00, Closed Book. Name : SOLUTION

Single Supply, Rail to Rail Low Power FET-Input Op Amp AD820

Laboratory 6. Lab 6. Operational Amplifier Circuits. Required Components: op amp 2 1k resistor 4 10k resistors 1 100k resistor 1 0.

Laboratory Activities Handbook

GATE: Electronics MCQs (Practice Test 1 of 13)

Operational Amplifiers

ECEN 325 Lab 5: Operational Amplifiers Part III

Difference between BJTs and FETs. Junction Field Effect Transistors (JFET)

Micropower, Single-Supply, Rail-to-Rail, Precision Instrumentation Amplifiers MAX4194 MAX4197

Homework Assignment 04

Bio-Potential Amplifiers

Analog Circuits Part 3 Operational Amplifiers

Introduction to Operational Amplifiers

Single Supply, MicroPower INSTRUMENTATION AMPLIFIER

School of Sciences. ELECTRONICS II ECE212A 2 nd Assignment

UNIVERSITY OF NORTH CAROLINA AT CHARLOTTE Department of Electrical and Computer Engineering

UNIT I. Operational Amplifiers

TRANSDUCER INTERFACE APPLICATIONS

Lab: Blood Pressure. Goal: Design and test a bandpass filter that can isolate a blood pressure signal.

Introduction to Analog Interfacing. ECE/CS 5780/6780: Embedded System Design. Various Op Amps. Ideal Op Amps

AN-1106 Custom Instrumentation Amplifier Design Author: Craig Cary Date: January 16, 2017

University of Pittsburgh

ECE4902 C Lab 5 MOSFET Common Source Amplifier with Active Load Bandwidth of MOSFET Common Source Amplifier: Resistive Load / Active Load

An 8-Channel General-Purpose Analog Front- End for Biopotential Signal Measurement

Ques on (2): [18 Marks] a) Draw the atrial synchronous Pacemaker block diagram and explain its operation. Benha University June 2013

LINEAR IC APPLICATIONS

Capacitive Touch Sensing Tone Generator. Corey Cleveland and Eric Ponce

IN Branch GATE Paper 1999 SECTION A

Electrical Safety. Principles and examples of safety. History of (electrical) safety. Rules and regulations. Safety in the Hospital

ES250: Electrical Science. HW6: The Operational Amplifier

An active filters means using amplifiers to improve the filter. An acive second-order RC low-pass filter still has two RC components in series.

*Notebook is excluded

LF442 Dual Low Power JFET Input Operational Amplifier

250 MHz, General Purpose Voltage Feedback Op Amps AD8047/AD8048

ECE 363 EXAM #2 (F18) 4 problems for 100 pts Problem #1: Amplifier Output Error (25 pts)

ELC224 Final Review (12/10/2009) Name:

NOVEMBER 29, 2017 COURSE PROJECT: CMOS TRANSIMPEDANCE AMPLIFIER ECG 720 ADVANCED ANALOG IC DESIGN ERIC MONAHAN

Digital Applications of the Operational Amplifier

Department of Mechanical and Aerospace Engineering. MAE334 - Introduction to Instrumentation and Computers. Final Examination.

Analog Electronics. Lecture Pearson Education. Upper Saddle River, NJ, All rights reserved.

Introduction to Op Amps

Laboratory 9. Required Components: Objectives. Optional Components: Operational Amplifier Circuits (modified from lab text by Alciatore)

Linear IC s and applications

Amplifiers in systems

Biomedical. Measurement and Design ELEC4623. Lectures 9 and 10 Practical biopotential amplifier design and multilead ECG systems

Pulse Oximetry. Principles of oximetry

Biomedical Electrodes, Sensors, and Transducers. Definition of Biomedical Electrodes, Sensors, and Transducers. Electrode: Sensor: Transducer:

Design and Simulation of Low Voltage Operational Amplifier

ETIN25 Analogue IC Design. Laboratory Manual Lab 2

Dual, Current Feedback Low Power Op Amp AD812

ENGR4300 Test 3A Fall 2002

Operational amplifiers

EXAM Amplifiers and Instrumentation (EE1C31)

OBSOLETE. Low Cost Quad Voltage Controlled Amplifier SSM2164 REV. 0

Quad Picoampere Input Current Bipolar Op Amp AD704

or Op Amps for short

Measurement and Analysis for Switchmode Power Design

P08050 Testing Strategy Document

UNIVERSITY OF UTAH ELECTRICAL AND COMPUTER ENGINEERING DEPARTMENT ELECTROMYOGRAM (EMG) DETECTOR WITH AUDIOVISUAL OUTPUT

Advanced Measurements

Precision OPERATIONAL AMPLIFIER

University of Michigan EECS 311: Electronic Circuits Fall 2009 LAB 2 NON IDEAL OPAMPS

EE LINEAR INTEGRATED CIRCUITS & APPLICATIONS

Dual operational amplifier

Designing Information Devices and Systems II Fall 2018 Elad Alon and Miki Lustig Homework 4

Unit WorkBook 1 Level 4 ENG U22 Electronic Circuits and Devices 2018 UniCourse Ltd. All Rights Reserved. Sample

Transcription:

Name (Last, First): BENG 186B Winter 2013 Final This exam is closed book, closed note, calculators are OK. Circle and put your final answers in the space provided; show your work only on the pages provided. Include units. Do not attach separate sheets. If you need more space, use the back of the pages. Points for each problem are given in [brackets], 100 points total. Useful schematics and equations: The Goldman-Hodgkin-Katz (GHK) equation: P K " # K + $ % + P E = ( 60mV )! log o Na " # Na + $ % + P o Cl " # Cl & $ 10 P K " # K + $ % + P i Na " # Na + $ % + P i Cl " # Cl & $ % i % o Common mode gain and differential gain: v o = A d v d + A c v cm v d = v a v b v cm = (v a + v b ) / 2 1 /10 2 /16 3 /10 4 /10 5 /15 6 /5+ 7 /10 8 /10 9 /10 10 /4 Total /100 T High = 0.7 (R A + R B ) C ; T Low = 0.7 R B C T Pulse = 1.1 R C

1. Circle the letter of the best (one and only one) answer for each. [10 pts; 1 pt each] A) Precision of an instrument is: a) Largest signal that it can measure without distortion. b) Difference between its true output and its measured value. c) Standard deviation of its measured output. d) Smallest measurable increment in its output. e) Ratio of signal amplitude over noise amplitude. B) A second-order system with decaying oscillatory output in response to a step input is: a) Overdamped. b) Unstable. c) Undamped. d) Underdamped. e) Critically damped. C) Inertance in a hydraulic system is related to: a) Fluid viscosity. b) Compliance of the catheter. c) Cross-sectional shape of the pipe. d) Air bubbles. e) Conservation of momentum. D) For blood flow measurement by bolus injection of a fixed amount of contrast agent, a larger area under the measured concentration curve indicates: a) Higher flow. b) Lower flow. c) No change in flow. d) More flow delay. e) No flow.

E) Choose the correct answer. a) EOG signal can show up in EEG measurements. b) ECG is commonly an invasive procedure. c) ERG is used to measure eye movements. d) ECoG measures electrical activity in the colon. e) EMG measures the electrical activity of smooth muscle. F) When positive electrical current passes through an Ag/AgCl electrode immersed in a KCl solution: a) More AgCl deposits onto the electrode. b) Some of the AgCl on the electrode dissolves into the solution. c) Electrons leave the solution. d) Electrons enter the solution. e) None of the above. G) Choose the correct answer. a) Arterial pressure is lower than venous pressure. b) The sounds heard when the blood pressure cuff relaxes originate in the heart. c) Electrostatic potential across a blood vessel in a magnetic field is proportional to blood velocity. d) Tonometers measure frequency shift in reflected sound. e) None of the above. H) What is the purpose of DRL with a bioinstrumentation amplifier? a) To increase the CMRR of the amplifier. b) To reduce power consumption of the amplifier. c) To increase input impedance of the amplifier. d) To increase the grounding impedance of the body. e) None of the above.

I) PO 2 is measured with: a) A Clark electrode. b) A Severinghaus electrode. c) A ph electrode in a buffer of saturated NaCO 3. d) Pulse oximetry. e) None of the above. J) A microshock is: a) A minor electrical shock above the perception threshold, but below fatality levels. b) An electrical shock caused by an optical fiber catheter. c) An electrical shock where some part of the current passes through the heart. d) An electrical shock where all current passes through the heart. e) The minor effect on the human body of electrostatic discharge in improperly grounded bioinstrumentation.

2. Short answer, write your answer only in the space provided. [16 pts; 2 pts each] (a) What is the relative accuracy (tolerance) of a stretchable resistor with strain gauge factor G = 2 and Young s modulus E = 10 kpa as it undergoes up to 100 Pa stress due to stretching? (b) An operational amplifier (opamp) has a gain-bandwidth product of 10 6 Hz, and a DC open-loop gain of 10 4. What is the cut-off frequency of the openloop opamp? What is the cut-off frequency of the closed-loop opamp connected as a non-inverting amplifier with unity gain (voltage buffer)? (c) What is the difference between ENG and EMG?

(d) Show a simplified circuit model of the electrode-skin impedance and identify key components in the model. (e) Using Einthoven s triangle, express lead voltages III and avl in terms of lead voltages I and II. III = avl = (f) Find the binary values of outputs Y1 and Y2 for all binary values of inputs A and B in the table below. What binary arithmetic does this circuit implement? A B Y 1 Y 2 0 0 0 1 1 0 1 1

(g) What is the Doppler frequency shift for blood moving at velocity v = 1 m/s towards an ultrasonic transmitter and receiver of frequency f = 1 MHz and wave propagation speed c = 10 3 m/s? (h) What is the use of adding a large resistance in series with the output of an opamp, when feeding back this output to the inverting input of the opamp through another resistor?

3. [10 pts]. Consider the following amplifier circuit with resistances R 1 = 1 kω, R 2 = R 3 = 10 kω, R 4 = 1 MΩ, R 5 = 100 kω, and R 6 = 1 kω. You may assume that the op-amp is ideal and not saturated. R 4 + V in - R 2 - R 1 R 3 + + R 6 V out V DD =5V - R 5 R 5 (a) [6 pts] Find the output voltage V out as a function of input voltage V in. Answer: V out =

(b) [2 pts] Find the input impedance Z in. Answer: Z in = (c) [2 pts] Find the output impedance Z out. Answer: Z out =

4. [10 pts]. A typical EMG bioamplifier circuit is given below. You may assume that the op-amps are ideal and not saturated. (a) [5 pts] Find the transfer function H(jω) = v out (jω) / v in (jω). Answer: H(jω) =

(b) [5 pts] Find the maximum gain, low cutoff frequency, and high cutoff frequency of the filter response for R 1 = R 1 = 10 kω, R f = R f = 1 MΩ, R = 1 MΩ, R = 10 kω, R L = 100 kω, and C = C = 100 nf. Sketch the Bode plot (log amplitude and phase as a function of log frequency). Note: 1 / 2π = 0.159 Answers: A max = f low = (Hz) f high = (Hz) (Bode plot on the next page.)

5. [15 pts] Saccharomyces cerevisiae is a species of yeast, which has been historically used to convert carbohydrates to carbon dioxide and alcohol. Looking to accelerate the brewing process of your favorite homemade beer, you create an incubator to optimize the fermentation process by maintaining the brewing temperature at its optimal value (see Table 1). For this, you have constructed the circuit shown in the figure below, which consists of a linear-output temperature sensor TMP36 (specifications in Table 2), an amplifier, and a comparator. This circuit is used to turn an electronic heater on and off by digitally controlling a solid-state relay (switch). Table 1: Release of CO 2 (in grams) at 20, 25, 30, 35, and 40 C. Slaa, J., Gnode, M., & Else, H., Yeast and fermentation: the optimal temperature, Journal of Organic Chemistry: Chem. Dut. Aspects 134, October, 2009. Table 2: Specifications of TMP36. Component TMP36 Description Temperature sensor, which outputs an analog voltage (V out ) proportional to ambient temperature. Pin 1 (+Vs) Source voltage Between 2.7V and 5.5V Pin 2 (Vout) Output voltage (linear with temperature) 0V at - 50 C 1.75V at 125 C Pin 3 (GND) Ground Ground Temperature control circuit. All opamps are ideal and powered with 5V and +5V.

Using the data in Table 1, the datasheet specifications of the TMP36 in Table 2, and the following observations, answer the questions below. Obs. 1: The output of the TMP36 is linear with the temperature (see Table 2). Obs. 2: The opamps are ideal and operate between 5V and +5V. Obs. 3: The output at +5V turns the heater on, while 5V turns it off. a) [2 pts] What is the ideal brewing temperature? Answer: T ideal = b) [3 pts] What are the outputs of the TMP36 at temperatures of 1 C and +1 C around the ideal temperature? Answers: V below = ( 1 C below T ideal ) V above = (+1 C above T ideal )

c) [10 pts] Select the ideal value of V 1 (a constant voltage between the 5V and +5V supplies) in the circuit in order to maintain the brewing temperature between 1 C and +1 C of the ideal temperature (as to avoid erratic switching of the heater). Answer: V 1 =

6. [5 pts] Design an implantable pacemaker circuit that outputs a periodic voltage pulse of duration 1 ms, period 1 s, and amplitude +3.6 V from ground. You can use 1.2 V buttoncell batteries, 555 timers, OP27 opamps, LM311 comparators, 10 nf capacitors, any size resistors, and any logic gates. BONUS [+5 pts extra]: Design your circuit with short-circuit protection, with output impedance less than 1 Ω, but with maximum output current ±360 µa.

7. [10pts] Find the resting potential of a membrane permeable to K +, Na +, and Cl considering that: The permeability of Na + is half of the permeability of K +. The permeability of Cl is half of the permeability of Na +. The concentration of K + is the same inside and outside. The outside concentration of Na + is four times the concentration of K +, and the inside concentration of Na + is eight times smaller than K +. The outside concentration of Cl is half that of Na +, and the inside concentration of Cl is four times that of Na +. Answer: E resting =

8. [10 pts] The following table represents the absorptivity of two similar compounds in a substance as a function of wavelength. Compound 500nm 800nm A 3 l/mmol m 2 l/mmol m B 1 l/mmol m 2 l/mmol m You test a particular compound and find it to have equal absorbance of 0.1 at 500 nm and 800 nm wavelength, through 1 cm of tissue. Beer s law of volume absorbance: A(λ) = W L a(λ) a) [3 pts] What is the concentration of the combined substance? b) [5 pts] What are the relative amounts of the two compounds? c) [2 pts] What is the isosbestic wavelength for these two compounds?

9. [10 pts] Consider the bioinstrumentation amplifier shown below with circuit resistances R 1 = R 3 = 1 kω, R 2 = R 4 = 100 kω and with electrode-skin contact resistances R LA = 110 kω and R RA = 90 kω. The opamps are ideal except with input impedance R in = 200 MΩ to ground on each of their inputs. V LA R LA + + - R 2 R 3 R 4 V in V C R 1 R 1 + - V OUT R 3 R 4 - V RA R RA - + R 2 a) [8 pts] Find the differential gain A d, common mode gain A cm, and effective CMRR of the bioamplifier. Answers: A d = A cm = CMRR eff =

b) [2 pts] What would be the effect of shorting the V c node to ground on the operation of the circuit?

10. [4 pts] Wireless Non-contact ECG and EEG a) [1 pt] What is required of a bioamplifier to acquire an ECG signal through a capacitive non-contact electrode? b) [1 pt] Give one example of a convenient recording site for ECG routine measurements that does not rely on patient compliance. Wireless and Global Health a) [1 pt] What has historically been the greatest advance in public health? b) [1 pt] Give one example of a wireless health engineering solution that does not solve a biomedical problem.