An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements

Similar documents
Organisation Internationale de Métrologie Légale

GRAS 40BD-FV 1/4" Prepolarized Pressure Microphone, Front Vented

Acoustic Calibration Service in Automobile Field at NIM, China

Technical Data Measurement Microphones

Multi-field Microphone when the Sound Field is unknown

Pilot Study EURAMET.AUV.V-P1: Bilateral comparison on magnitude of the complex charge sensitivity of accelerometers from 10 Hz to 10 khz

MS8216 DIGITAL MULTIMETER OPERATOR S MANUAL

UPGRADE OF THE MEDIUM AND HIGH FREQUENCY VIBRATION CALIBRATION REFERENCE EQUIPMENT AND EXTENSION TO LOW FREQUENCIES

Organisation Internationale de Métrologie Légale

TECHNICAL PROTOCOL FOR KEY COMPARISON CCAUV.A-K4

NATIONAL TELECOMMUNICATIONS AGENCY RESOLUTION Nº 238, NOVEMBER

Microphone Cartridge Model: MP201

USER MANUAL. Ultra-Low Noise High Voltage Amplifier WMA V to +150V output. 300µV rms output noise. 2mV output offset voltage

Informations and comments on ECE-TRANS-WP.29-GRB e

ISO INTERNATIONAL STANDARD

AN5E Application Note

USER. manual. Falco Systems WMA-100. High Voltage Amplifier DC - 500kHz

INSTRUCTION MANUAL MODEL 8820 Multi-Function Environment Meter

valve master compressor

INSTRUCTION MANUAL MODEL 21 MULTI-TESTER

INTERNATIONAL STANDARD

USER MANUAL. DC - 5MHz High Voltage Amplifier WMA V to +100V output. DC to -3dB large signal bandwidth. 1300V/µs slew rate typical

Micro-nanosystems for electrical metrology and precision instrumentation

Microphone calibration service for airborne ultrasound

DIGITAL MULTIMETER OPERATOR S MANUAL

DIGIT & POINTER MULTIMETER

VM2000. Low-Noise Bottom Port Piezoelectric MEMS Microphone Data Sheet Vesper Technologies Inc. Differential Analog Output

FRAX Series Sweep Frequency Response Analyzers

ISO INTERNATIONAL STANDARD. Acoustics Unattended monitoring of aircraft sound in the vicinity of airports

Baro Transmitter PTB x1.073

PERFORMANCE OF A NEW MEMS MEASUREMENT MICROPHONE AND ITS POTENTIAL APPLICATION

instructions for Models QC-10 and QC-20 Sound Calibrators MODELS QC-10/QC-20 SOUND CALIBRATORS GENERAL DESCRIPTION

SW Series Impedance Tube Solutions

OtoRead - Technical Specifications Page 0. Technical Specifications. OtoRead D A 2017/06

NT1-A Instruction Guide

SHURE INCORPORATED KSM109 CARDIOID CONDENSER MICROPHONE. Thank you for selecting the KSM109

Sound Level Meter C.A 832

Sound level meter directional response measurement in a simulated free-field

Experiment No. 3 Pre-Lab Phase Locked Loops and Frequency Modulation

Opamp stability using non-invasive methods

THE ATTENUATION OF NOISE ENTERING BUILDINGS USING QUARTER- WAVE RESONATORS: RESULTS FROM A FULL SCALE PROTOTYPE. C.D.Field and F.R.

OPERATING MANUAL. Measurement Microphones

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 29000

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

2018 Data Sheet Vesper Technologies Inc. VM1000. Low-Noise Bottom Port

In situ assessment of the normal incidence sound absorption coefficient of asphalt mixtures with a new impedance tube

THECULTURE VULTURE mastering PLUS

PRODUCT DATA. Sound Intensity Probe Kit Type 3599 including Sound Intensity Microphone Pair Type 4197 and Dual Preamplifier Type 2683

ISO INTERNATIONAL STANDARD

OPERATING MANUAL. Measurement Microphones

SOUND LEVEL METER OPERATION MANUAL. Model : SL Your purchase of this

DVM1190 DIGITAL MULTIMETER

EUROPEAN pr I-ETS TELECOMMUNICATION June 1996 STANDARD

TPS 49 EDITION 2 JUNE 2009

Nor150 Sound Intensity Option Sound intensity probe Nor1290

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

INTERIM EUROPEAN I-ETS TELECOMMUNICATION December 1994 STANDARD

PD002. Product Data ZIRCON. Loudspeaker-Microphone Probe

Bedienungsanleitung Instruction Manual. testo 815 Sound Level Meter

OPTITEMP. Compact sensors

PXIe Contents. Required Software CALIBRATION PROCEDURE

SLM-52N INSTRUCTION MANUAL

INSTRUCTION MANUAL PCE-222

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

INTERNATIONAL STANDARD

Technical Documentation

Validation and evolution of the road traffic noise prediction model NMPB-96 - Part 1: Comparison between calculation and measurement results

DM-45 Digital Multimeter

BM-500 Professional studio recording microphone

Bi-lateral comparison of pistonphone calibration between INMETRO and INTI

NEW MV CABLE ACCESSORY WITH EMBEDDED SENSOR TO CHECK PARTIAL DISCHARGE ACTIVITY

Table 2 Models BST12L-0.7S10PDM BST12L-0.7S16PDM BST12L-0.7S25PDM Conditions Input voltage range

ENHANCEMENT OF THE TRANSMISSION LOSS OF DOUBLE PANELS BY MEANS OF ACTIVELY CONTROLLING THE CAVITY SOUND FIELD

DIGITAL MULTIMETER INSTRUCTION MANUAL

The ME 36 is a condenser microphone capsule. This mini shotgun microphone features for an outstanding background noise rejection.

ULTRAVOLT TF SERIES HIGH VOLTAGE TEST FIXTURES

Artificial Mastoid Calibration System at NIM, China. ZHONG Bo

THECULTURE VULTURE valve distortion unit

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

ISO INTERNATIONAL STANDARD. Non-destructive testing Ultrasonic thickness measurement

Selection and Calibration of Acoustic Sensors

Visit us at

C1.1 Specification of the SVAN 971 as SLM in the standard configuration

ECE 4670 Spring 2014 Lab 1 Linear System Characteristics

Manual Supplement. This supplement contains information necessary to ensure the accuracy of the above manual.

Protocol for Ambient Level Noise Monitoring

USER MANUAL. DC 13kHz High Voltage Amplifier WMA V to +175V output. Stable with all capacitive loads, generates no overshoot

Hydrophone TC4032 Low Noise Sea-State Zero Hydrophone

ProfiScale MULTI Multimeter

MS6231 DIGITAL ENGINE ANALYZER OPERATOR S MANUAL CONTENTS CONTENTS

Nor150 Sound Intensity Option Sound intensity probe Nor1290

Testing Power Sources for Stability

Josephson Engineering, Inc. 329A Ingalls Street Santa Cruz, California Josephson Engineering Rev B

Minirators MR-PRO / MR2

Fundamentals of Environmental Noise Monitoring CENAC

DMM8900 SERIES USERS MANUAL

TA MHz ±700 V Differential Probe User s Manual. This probe complies with IEC , IEC CAT III, Pollution Degree 2.

# Digital Multimeter

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

Transcription:

An automatic method to detect defaults in the measurement chain of a sound level meter, used for unattended noise measurements E. Aflalo a, F. Dupont a, P. Cellard b and J.-N. Durocher b a 01dB-Metravib, 200 Chemin des Ormeaux, 69578 Limonest, France b Laboratoire national de métrologie et d essais, 29, avenue Roger Hennequin, 78197 Trappes Cedex, France erik.aflalo@01db-metravib.com 2035

Proceedings of the Acoustics 2012 Nantes Conference The built-in electrical check (multi-frequencies charge injection) allows for testing the whole measurement chain, including the microphone. It consists in injecting a sinusoidal charge (1 or 2 levels) into the microphone membrane, at selected frequencies. The principle is to collect reference values (initialization stage) and to check over time if the deviation between reference values and measured values exceeds a maximum predefined deviation value. A multiple-frequency check offers the advantage of a better assessment of a possible degradation of the microphone membrane or of the electronic components. The checking procedure lasts from 10 to 30 seconds and automatically occurs during the measurement, logged values before and after the checking clearly separated, so to make their validation easier. The purpose of the paper is to describe the results obtained for different types of defaults in the measurement chain. 1 Introduction The risk of wrong measurements in environmental noise assessment must be reduced as low as possible. The sound level meters or the equivalent measurement chains, including the associated sound calibrator, have to be periodically calibrated by the manufacturer or in a metrology laboratory. These calibrations ensure the traceability to International System of Units but should be carried out at least every second year. The IEC 61672-3 standard [1] describes such a periodic tests of sound level meters. The main way to reduce the risk of biased measurements is to calibrate the measuring device before each measurement; it is typically a daily control. The calibration is followed, if necessary, by an adjustment, i.e. a calibration factor correction. Often the test codes require checking also the calibration at the end of the measurement, to verify the absence of failure during the measurement. This is a common and simple method to check if the measurement chain remains stable over time. The sound calibrator allows detecting a change in the sensitivity of the microphone. A sudden change in the microphone sensitivity leads us to think that a fault has appeared since the last calibration. A slow evolution of the calibration factor can also be a warning of a microphone aging. This practice is not found to be sufficient because the sound calibrators used are mainly single frequency (usually 94dB @ 1000 Hz) and therefore cannot detect defaults at other frequencies. Fig. 1 shows a picture of a damaged microphone and Fig.2 shows the corresponding frequency response. In this particular example, the frequency response proves that the microphone is fully unusable even though its sensitivity at 1000 Hz is not affected. A single calibration at 1000 Hz would therefore not detect the microphone degradation. Fig. 2: corresponding frequency response As a result, it is always recommended to make more extensive checks from time to time, more frequently than the periodic tests carried out by the manufacturer or by a metrology laboratory. Such checks are required in some standards, becoming mandatory: see 4.84.automatic check in the ISO 20906 standard [2] and see annex A in NFS 31-010 standard [3] with a six-month periodicity. This paper can also be of interest by showing the link between some physical damages in the microphone, visible or not (bad contact) and its frequency response or its background noise level. 2 Multi-frequencies charge injection principle This test consists in injecting a stable reference signal though a reference capacitor that simulates an acoustic signal at the microphone output (see the dash lines in Fig. 3: Fig 3: charge injection principle Fig.. 1: microphone with damaged membrane The reference signal is a frequency user defined sine at a selectable level between 0 and 5 V peak. The capacity for the reference C charge injection is typically around 0.2 pf. The test consists in creating reference values on a valid system and measure through the sound level meter measurement chain itself the difference in db with the 2036

current situation. The value of the deviation will be representative of a variation of the system. Charge injection will behave as an impedance comparison between the condenser microphone and C charge injection reference capacitor. If the impedance of the microphone is changed (typically a mechanical damage of the active part of the membrane that will change its capacity) the charge injection method will detect it. 6 Tests results and analysis 6.1 Punching of the membrane 3 Test conditions Tests are performed in one of the anechoic rooms at LNE (Laboratoire National d Essais), the selected instrument, DUO [4], is used in vertical position: Fig. 5: membrane punched Fig. 4: Test set-up with DUO in vertical position 4 Checking description: For each test, a microphone is damaged on purpose and the following measurements are performed before and after damage: A-weighted background noise level (measured around 18 dba when no default) Sensitivity @ 1 khz 250 Hz, 500 Hz, 1 khz, 2 khz and 4 khz The frequency response is also measured and is used as the reference: if the frequency response shows a default (red curves in the following figures), will the checking procedure detect it? 5 Defaults made on microphones The following defaults have been created on different microphones: Punching of the membrane Water drop on the membrane Light dust on the membrane Heavy dust on the membrane Shock on the edge of the microphone Small cut on the edge of the microphone Large cut on the edge of the microphone Bad contact at the inner pin of the microphone Fig. 6: corresponding frequency response Sensitivity @ 1 khz: -7 db 250 Hz, 500 Hz, 1 khz, 2 khz and 4 khz: From -0.36 db to -0.93 db This case is very similar to the example given in the introduction but with a shifted frequency response. Hopefully in that case the calibration procedure will detect the default. Multi-frequencies charge injection response is sensitive to this default; the mechanical damage has changed the capacity of the microphone. 2037

6.2 Water drop on the membrane Proceedings of the Acoustics 2012 Nantes Conference 6.3 Light dust on the membrane Fig. 7: water drop on the membrane Fig. 9: light dust on the membrane Fig. 8: corresponding frequency response A weighted background noise level: +3 db Sensitivity @ 1 khz: +0.5 db 250 Hz, 500 Hz, 1 khz, 2 khz and 4 khz: 1.45 db@4 khz Background noise has slightly increased, but the absolute value of 21 dba is not easy to measure under normal conditions. The increase of sensitivity shows there could be instability in the system, but the displayed value (+0.5dB change) could be linked to changes in temperature, humidity and/or barometric pressure. The frequency response is altered and reacts as an increase of mass with a resonant frequency around 3 khz. The multi-frequencies charge injection response shows a difference, clearly indicating a default in the system (mechanical change of the membrane due to the weight of the water drop). Fig. 10: corresponding frequency response Sensitivity @ 1 khz: Not No indicator is, and the frequency response does not show a difference either. Dust on the membrane will almost have no incidence on the measurement quality. This experimentation shows it is better NOT to clean a microphone, to avoid any risk of damage during cleaning. 2038

6.4 Heavy dust on the membrane 6.5 Shock on the edge of the microphone Fig. 11: heavy dust on the membrane Fig.13: shock on the edge of the membrane Fig. 12: corresponding frequency response Sensitivity @ 1 khz: Not 250 Hz, 500 Hz, 1 khz, 2 khz and 4 khz: + 0.38 db @4 khz This case is over the acceptable limits of dust on a membrane! The frequency response is altered and reacts as an increase of mass with a resonant frequency around 2.5 khz. Multi-frequencies charge injection response detects a slight difference due to the weight of dust. Fig. 14: corresponding frequency response Sensitivity @ 1 khz: Not This example is one of the most common damage of a microphone when a sound level meter is used in the field. The frequency response only shows a small increase of the sensitivity of around 0.3 db on the whole frequency range. In fact the only consequence of this default is a lower tension of the membrane without real effect on the measurement. Multi-frequencies charge injection response does not detect any default because the active part of the membrane is not affected. 2039

6.6 Small cut on the edge of the microphone Proceedings of the Acoustics 2012 Nantes Conference 6.7 Large cut on the edge of the microphone Fig. 15: small cut on the edge of the microphone Fig. 17: large cut on the edge of the microphone Fig. 16: corresponding frequency response Sensitivity @ 1 khz: + 1 db The frequency response shows an increase of the sensitivity of around 1 db on the whole frequency range. The consequence of this default is a lower tension of the membrane and is detected by the sound level calibrator. Multi-frequencies charge injection response does not detect any default because the active part of the membrane is not affected. Fig. 18: corresponding frequency response Sensitivity @ 1 khz: + 2 db The frequency response shows an increase of the sensitivity of around 2 db on the low and middle frequency ranges. The consequence of this default is a lower tension of the membrane and is detected by the sound level calibrator. Multi-frequencies charge injection response does not detect any default because the active part of the membrane is not affected. 2040

6.8 Bad contact at the inner pin of the microphone (simulation with humid thin paper) Fig. 19: humid paper on the inner pin of the microphone Fig. 20: corresponding frequency response A weighted background noise level: + 20dB Sensitivity @ 1 khz: - 0.7dB 250 Hz, 500 Hz, 1 khz, 2 khz and 4 khz: > 6 db on all frequencies This example illustrates a default that can happen when a sound level meter has been in use for several months without periodic maintenance. Despite the fact the connectors are gold plated, some corrosion might occur, especially if the contacts have been touched by fingers. The frequency response shows a high-pass filter effect. The decrease of sensitivity shows there could be instability in the system, but the displayed value (-0.7 db change) could be linked to changes in temperature, humidity and/or barometric pressure. This default is detected by an increase of background noise and by multi-frequencies charge injection response. The impedance of the equivalent microphone has drastically changed, that explains the high sensitivity to multi-frequencies charge injection response. 7 Conclusions The various tests performed show the usefulness of the multi-frequencies charge injection method to detect common defaults (punching of the membrane, water or dust on the membrane, bad contact). Only the cut at the edge of the membrane could not be detected by charge injection during this test because it does not create any change in the impedance of the microphone (this default can be detected by a calibration). The choice of the five frequencies used by default (250 Hz, 500 Hz, 1 khz, 2 khz and 4 khz) can be optimized: we recommend selecting 63 Hz, 250 Hz, 1 khz and 4 khz. The maximum acceptable difference between the reference and the current measurement is to be set between 0.35 db and 0.5 db for an accurate detection of the defaults. For such values it is of major importance to pay attention to the stability of the high precision generator. The charge injection being nearly equivalent to 100 db level for a 5 V signal, the measured level may be affected by the ambient acoustic noise if the level is higher than 90 db. It is therefore recommended to ensure the absence of noise disturbances during the test and to repeat the procedure if necessary. The multi-frequencies charge injection method is not a calibration of the system. Its purpose is to control over time the stability of a noise measurement equipment. When performed periodically automatically and remotely (typically from one to four times a day) it will secure the validity of the measurement between two checks. Multi-frequencies charge injection check is one of the useful tools for ensuring reliable measurements between two calibrations on unattended measurement systems. Acknowledgments Grateful acknowledgments to Dominique Rodriguez from LNE for his availability and knowledge sharing. The authors would like to thank the animator of the working group Autocontrôle des sonomètres within S30J commission, Daniel Brassenx (RATP). References [1] IEC 61672-3 2006-10 Electroacoustics-sound level meters part 3: Periodic tests [2] ISO 20906:2009 Acoustics - Unattended monitoring of aircraft sound in the vicinity of airports [3] NF S31-010 Décembre 1996 Acoustique -- Caractérisation et mesurage des bruits de l'environnement - Méthodes particulières de mesurage [4] 01dB, a brand of ACOEM: DUO Product data sheet: NOT 1507 December 2011 2041