Experimental And FE Analysis Of Eccentric Loaded Symmetrical And Unsymmetrical Bolted Joint With Bolt Pretension

Similar documents
Stress Analysis Of Bolted Joint

SIMULATION AND EXPERIMENTAL WORK OF SINGLE LAP BOLTED JOINT TESTED IN BENDING

1. Enumerate the most commonly used engineering materials and state some important properties and their engineering applications.

Numerical and Experimental Study of Shear Loaded Bolted Joint

Note: Conditions where bending loads are imposed on the bolt e.g. non-parallel bolting surfaces, should be avoided.

CH # 8. Two rectangular metal pieces, the aim is to join them

Bolt Material Types and Grades 1- Bolts made of carbon steel and alloy steel: 4.6, 4.8, 5.6, 5.8, 6.8, 8.8, 10.9 Nuts made of carbon steel and alloy

Structural and Thermal Analysis of Bolted joint of Coiler Drum in Steckel Mill using Finite Element Method

Stress Analysis of Flanged Joint Using Finite Element Method

DESIGN, ANALYSIS AND OPTIMIZATION OF CURVE ATTACHMENT ON COMPOSITE HYBRID LAP JOINT

UNIVERSITY OF THESSALY

Mechanical joints. Major diameter Mean diameter Minor diameter Pitch p chamfer. Root Crest. Thread angle 2a. Dr. Salah Gasim Ahmed YIC 1

AN INNOVATIVE FEA METHODOLOGY FOR MODELING FASTENERS

Effect of Bolt Layout on the Mechanical Behavior of Four Bolted Shear Joint

An Alternative Formulation for Determining Stiffness of Members with Bolted Connections

Stress Analysis of Bolts Failure in Flange Joint of Coiler Drum in Steckel Furnace by Using Fem Methods

Keywords: Bracing bracket connection, local deformation, selective pallet racks, shear stiffness, spine bracings.

REVIEW OF THREADED FASTENERS LOOSENING AND ITS EFFECTS

TORQUE DESIGN, ANALYSIS AND CHARACTERIZATION OF CRITICAL FASTENERS IN DIESEL ENGINES

3-D Finite Element Analysis of Bolted Joint Using Helical Thread Model

An Investigation of Optimal Pitch Selection to Reduce Self-Loosening of Threaded Fastener under Transverse Loading

Failure analysis of buttress, acme and modified square threaded mild steel (is2062) tie rods

1/2/2016. Lecture Slides. Screws, Fasteners, and the Design of Nonpermanent Joints. Reasons for Non-permanent Fasteners

Static Analysis of Bolt Due To Random Vibration Used In Turbine

DESIGN OF MACHINE MEMBERS-I

THE GATE COACHAll Rights Reserved 28, Jia Sarai N.Delhi ,-9998

Studies on free vibration of FRP aircraft Instruments panel boards

Failure of Engineering Materials & Structures. Code 34. Bolted Joint s Relaxation Behavior: A FEA Study. Muhammad Abid and Saad Hussain

Bolt Tensioning. This document is a summary of...

Experimental and Finite Element Analysis of Preloaded Bolted Joints Under Impact Loading

ERECTION & CONSTRUCTION

Figure 1: Photograph of Drop Weight Test Machine

THE INFLUENCE OF GEOMETRIC PARAMETERS AND MECHANICAL PROPERTIES OF ADHESIVE ON STRESS ANALYSIS IN ADHESIVELY BONDED ALUMINUM SINGLE LAP JOINT

a) If a bolt is over-tightened, which will fail first the bolt, or the plastic?

Experimental Evaluation of Metal Composite Multi Bolt Radial Joint on Laminate Level, under uni Axial Tensile Loading

ISO INTERNATIONAL STANDARD. Fasteners Torque/clamp force testing. Éléments de fixation Essais couple/tension. First edition

What happens to bolt tension in large joints?, Fasteners, Vol. 20, No. 3, 1965, Publication No. 286

Structural Strength of Lapped Cold-Formed Steel Z-Shaped Purlin Connections with Vertical Slotted Holes

Fig. (8.1) types of riveted joints

Design and Analysis of Progressive Die for Chain Link Plate

EFFECTS OF GEOMETRY ON MECHANICAL BEHAVIOR OF DOVETAIL CONNECTION

A Study on Effect of Sizing Bolt Hole in Single-Lap Connection Using FEA

Drawing of Hexagonal Shapes from Cylindrical Cups

TRANSVERSE FATIGUE CHARACTERISTICS OF BOLTED JOINTS TIGHTENED THIN PLATES

Prediction Of Thrust Force And Torque In Drilling On Aluminum 6061-T6 Alloy

EFFECT OF ADHEREND SHAPE ON STRESS CONCENTRATION REDUCTION OF ADHESIVELY BONDED SINGLE LAP JOINT

Pre stressed modal FE Analysis of bolted joint

Cast-in Ferrule Connections Load/Displacement Characteristics in Shear

Bhagwan mahavir college of Engineering & Technology, Surat.

A finite element stress analysis of aircraft bolted joints loaded in tension

Design and Manufacturing of Single sided expanding collet for Rotary VMC Fixture

Prying of a Large Span Base Plate Undergoing a Moment Load Applied by a Round Pier

Development of a Numerical Technique for the Static Analysis of Bolted Joints by the FEM

The Stamina of Non-Gasketed, Flanged Pipe Connections

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

Design, Development and Analysis of Clamping Force of a Cylinder of Fixture for Casing of Differential

Design of Machine Elements I Prof. G. Chakraborty Department of Mechanical Engineering Indian Institute of Technology Kharagpur

IJSRD - International Journal for Scientific Research & Development Vol. 4, Issue 05, 2016 ISSN (online):

The Behaviour Of Round Timber Sections Notched Over The Support On The Tension Face. Justin Dewey

A training course delivered at a company s facility by Matrix Engineering, an approved provider of Bolt Science Training

INFLUENCE OF SOME MODIFICATIONS OF LOCAL GEOMETRY ON THE STRESS STATES IN ADHESIVE BONDED LAP JOINTS

The Mobile Crane-Related Industrial Accident Caused by the Failures of Bolts

AMTS STANDARD WORKSHOP PRACTICE. Bond Design

Finite Element Analysis of Multi-Fastened Bolted Joint Connecting Composite Components in Aircraft Structures

STRESS ANALYSIS OF RIVETED LAP JOINT USING FINITE ELEMENT METHOD

Hazlan Abdul Hamid* & Mohammad Iqbal Shah Harsad

FASTENERS - BOLTED CONNECTIONS

Fluid Sealing Association

NYIT Instructors : Alfred Sanabria and Rodrigo Suarez

Influence of Lubrication and Draw Bead in Hemispherical Cup Forming

Welded connections Welded connections are basically the same design in AISI as in AISC. Minor differences are present and outlined below.

Threaded Fasteners 2. Shigley s Mechanical Engineering Design

Vertical Struts. P16603: Work Piece Movement Jonathan Sanabria April 19, Contents

Numerical Simulation and Analysis of Friction Drilling Process for Alumina Alloy using Ansys

DESIGN AND RELIABILITY INFLUENCES ON SELF-LOOSENING OF MULTI-BOLTED JOINTS

Shear Stress Analysis of Single Chain Riveted Lap Joint

Moment-Resisting Connections In Laminated Veneer Lumber (LVL) Frames

Using Shape Optimization Tool In Ansys Software For Weight Reducation Of Steel Connecting Rod

Wear Analysis of Multi Point Milling Cutter using FEA

Comparative structural Analysis of Acme and Square Thread Screw jack

Fatigue and Fretting Studies of Gas Compressor Blade Roots

Evaluation of In-Pavement Light Fixture Designs and Performance

INFLUENCE OF PILES ON LOAD- SETTLEMENT BEHAVIOUR OF RAFT FOUNDATION

S. Ramhormozian 1, G.C. Clifton 2 and H. Nguyen 3

Behaviour of fibre reinforced composite beams with mechanical joints

Permanent fasteners: Riveted joints Welded joints Detachable joints: Threaded fasteners screws, bolts and nuts, studs. Cotter joints Knuckle joints

ANALYSIS OF SURFACE ROUGHNESS WITH VARIATION IN SHEAR AND RAKE ANGLE

EXPERIMENTAL INVESTIGATION OF FATIGUE BEHAVIOUR IN COMPOSITE BOLTED JOINTS

Double Shear Testing of Bolts

Finite Element Modeling of Early Stage Self-loosening of Bolted Joints Haoliang Xu 1, a, Lihua Yang 1, b,, Lie Yu 1,2, c

Sliding shear capacities of the Asymmetric Friction Connection

NUMERICAL ANALYSIS OF SCREW ANCHOR FOR CONCRETE

Vibration Analysis of Adhesively Bonded Single Lap Joint

Hours / 100 Marks Seat No.

Performance Enhancement of Automotive Silencer Using Finite Element Analysis

of Screwed Joints. Screwed Joints n 377

EXAMPLE 1-4 EXAMPLE 1-5

Modelling of Rebar and Cable Bolt Behaviour in Tension/Shear

D DAVID PUBLISHING. Analysis of Leakage in Bolted-Flanged Joints Using Contact Finite Element Analysis. 1. Introduction.

CHAPTER 2 ELECTROMAGNETIC FORCE AND DEFORMATION

Transcription:

RESEARCH ARTICLE OPEN ACCESS Experimental And FE Analysis Of Eccentric Loaded Symmetrical And Unsymmetrical Bolted Joint With Bolt Pretension Pranav R. Pimpalkar*, Prof. S. D. Khamankar** *(P. G. student of M. Tech (CAD/CAM), Rajiv Gandhi College of Engineering, Research and Technology, Chandrapur (M.S.)) **(Associate Professor in Mechanical Department, Rajiv Gandhi College of Engineering, Research and Technology, Chandrapur (M.S.)) ABSTRACT This paper presents experimental and FE analysis of eccentric loaded bolted joint under symmetric and unsymmetrical bolt system with consider bolt pretension. A cad model of a bolted joint has been developed using modeling software PROE5.0 and FE analysis was carried out by using ANSYSWORKBENCH12.0.stress analysis has been carried out by varying bolt pattern of bolted joint for predict maximum heavily loaded bolt. Experimental work was conducted to measure maximum shear strength of the specimens for validation of the developed FE model. Experimental work was carried out on hydraulic jack and specimen of bolted joint was tested to know maximum shear strength of bolt. The results from both FE analysis and experimental work were then compared and show close results among them. Keywords: ANSYS WORKBENCH12.0, Bolt Pretension, FEM, PROE5.0. I. Introduction The Bolted joint is a very popular method of fastening components together. The prime reason for selecting bolts as opposed to welding or rivets are that the connection can be easily released allowing disassembly, maintenance and inspection. It has a various application for mechanical joint like in spacecraft, ship, internal combustion engine, automobile, or oilrig, etc and for civil structure and pipelines. There are many applications of the bolted joints which are subjected to eccentric loading such as wall bracket, pillar crane etc. Eccentric loaded bolted joint under symmetric and unsymmetrical bolt system as shown in Fig1.1 and Fig1.2. Bolted joints are critical structural regions and must be properly designed so that the desired performance from the overall structure is obtained. Because of large stress concentrations, joints can become a source of weakness if proper design practice is not followed. Accordingly, failures typically occurred at connections and interfaces, rather than within the bulk of the system. To provide a safe and cost-effective joint design, it is typical to configure the joint with respect to the geometry and the constituent materials, which affect both strength and failure modes. When the secondary shear load on each bolt is equal, then the heavily loaded bolt will be one in which the included angle between the direct shear load and secondary shear load is minimum. The maximum heavily loaded bolt becomes the critical one for determining the strength of the bolted joint. Fig. 1.1 Symmetrical eccentric loaded bolted joint Fig. 1.2 Unsymmetrical eccentric loaded bolted joint 1.1 Objectives and Methodology The main aim of this paper is to determine the stress distribution among region of failures for eccentrically loaded bolted joint and hence to carry out load carrying capacity of the bolt, also to study the effect of various design parameters as mentioned below. 1) To check performance of eccentric loaded bolted joint with symmetric pattern by consider bolt pretension. 32 P a g e

2) To check performance of eccentric loaded bolted joint with unsymmetrical pattern by consider bolt pretension. 3) A physical model of eccentric loaded bolted joint with symmetric pattern prepared and stresses are analyzed experimentally. 4) A physical model of eccentric loaded bolted joint with unsymmetrical pattern prepared and stresses are analyzed experimentally 5) FEM results and experimental results are compared. To meet with above mentioned objectives and for carrying out analysis, two models have been prepared as mentioned below. Model 1: Single Lap eccentric loaded Bolted Joint of symmetrical bolt system also it is subjected to design value of preload i.e. 9940N. Model 2: Single Lap eccentric loaded Bolted Joint of unsymmetrical bolt pattern with design value of preload i.e. 9940N For numerical analysis FEM is widely used tool in design, the objective of which is to find the stresses and strain in weaker element of product. Hence FEM analysis is carried out by using standard commercial software which then compared with analytical results and hence validated with experimental result for one of the case that has been included for analysis II. Determination of Breaking Stress in Symmetrical bolted joint by experimentation &its verification by FEM. A bolted eccentric loaded joint as shown in fig. 2.1 is considered for determination of breaking strength. A prototype of eccentric loaded bolted joint for symmetrical bolt pattern is prepared & it is tested by using setup of hydraulic jack. The photographs of experimentation are shown in fig.2.1 to fig.2.4. Fig 2.2 Mounting & Loading of Test specimen Fig. 2.3 Dial shows Ultimate shear strength of bolt in KN Fig 2.4 Failure of Test specimen Fig 2.1 Test specimen The bolt of diameter 7.0 mm has fail in breaking at a load of 3000 N which is the breaking strength for the bolted joint. 2.1 Analytical Calculation load on Horizontal Plate(P) = 3000 N Eccentricity (e) = 174mm Plate dimension=300x50x8mm Bolt diameter( d)=7.0mm 1) Center of gravity G of bolt system: - 33 P a g e

x = x1+x2+x3+x4,y = y1+y2+y3+y4 n n 2) Direct shear load on each bolt :- Ps = P n 3) Turning moment produced by load P due to eccentricity(e) =Pxe 4) Equating the turning moment due to eccentricity of the load due to the resisting moment of the bolt, PXe = F1 L1 (L12 + L2 2 + L3 2 + L4 2 + ) From equation value of F1 calculated and F2 = F1X L2 L3,F3 = F1X L1 L1 5) Resultant shear load, R= Ps 2 + F 2 + 2Ps. F. cos θ 6) Maximum shear stress, τ max = R π 4 d2 Breaking stress in shear by mathematical calculation has been found to be 253.96 MPa for symmetrical bolt pattern. 2.2 Determination of Breaking Stress by FE Analysis Analysis of Bolted joint is carried out by considering data as per experimentation & analytical calculation.the analysis is carried out by developing a model of eccentric loaded-joint on modeling software PRO ENGINEER 5.0 and this model is imported in ANSYS WORKBENCH 12.0. Table 2.2.2 Properties and dimension of the Plates Material type Modulus of elasticity Mild steel 200 Gpa Poisson s ratio 0.29 Thickness Width 2.2.2 Static Structural Analysis 10 mm 50 mm Fig 2.5 Geometrical model of Test specimen 2.2.1 Material Data Table 2.2.1 Properties and dimension of Bolt and nut Material type Medium carbon steel,quenched and tempered Modulus of elasticity, E 200 Gpa Poisson s ratio, μ 0.29 Proof strength Minimum tensile yield strength Minimum tensile ultimate strength Nominal length, L Nominal diameter, D Height of bolt, H Width across flat, F Width across corners, C Height of nut 580Mpa 640 Mpa 800 Mpa 45.74 mm 10 mm 7.0mm 17.9 mm 20 mm 8 mm Fig 2.6 Contact Region (Bonded Type) Fig 2.7 contact sizing 34 P a g e

III. Determination of Breaking Stress in Unsymmetrical bolted joint by experimentation & its verification by FEM An unsymmetrical eccentric loaded bolted joint is considered for determination of breaking strength. A prototype of bolted joint is prepared & it is tested by using setup of hydraulic jack.the photographs of experimentation are shown in fig. 3.1 to fig.3.3 Fig 2.8 Meshing (Course Mesh) Fig 3.1 Test Specimen of Unsymmetrical bolted joint Fig 2.9 Boundary and Loading Condition Fig 3.2 Test Setup Fig 2.10 Solution In analytical problem, the value of maximum permissible shear stress is 253.97 MPa and during FEM analysis, value obtained is in the range of 234MPa to 253MPa which is validated. Thus the FE model of bolted joint is validated for induced stresses. Fig 3.3 Failure of Test specimen The same experimental procedure has been applied for unsymmetrical bolt pattern which is previously discussed in section 4.2.After experimentation, bolt of dia 7.0 mm has fail in breaking at a load of 4000N which is the breaking strength for the bolted joint. 35 P a g e

3.1 Analytical Calculation The breaking stress determined from the breaking strength determined experimentally is calculated as follows: Breaking Load(P)=4000 N Eccentricity(e) = 174mm Dimension of plate=300x50x8mm Bolt dia(d)=7.0mm No of bolt, n=5nos Breaking stress in shear by mathematical calculation has been found to be 230.28 MPa for unsymmetrical bolt pattern. 3.2 Determination of Breaking Stress by FE Analysis for Unsymmetrical Bolted joint Analysis of Bolted joint is carried out by considering data as per experimentation & analytical calculation. The same FE analysis commands have been utilized for unsymmetrical bolt pattern which are previously discussed in section 2.2.2 Material properties have been remaining same which are taken in symmetrical bolt pattern in section 2.2.1. Fig 3.6 Meshing Fig 3.7 Boundary and loading condition Load value is taken from experimentation result i.e.4000n. Fig 3.4 Geometrical model of Test specimen Fig 3.8 Solution Fig 3.5 Bonded Contacts In analytical calculation, the value of maximum permissible shear stress is 230.28 MPa and during FEM analysis, value obtained is 230.33 MPa which is validated. Thus the FE model for unsymmetrical bolted joint is validated for induced stresses. IV. Result Results of Numerical calculation for all models considered for analysis are listed in tabular form as follows in Table no. 5.1 36 P a g e

Table 5.1 numerically determined stresses for all models under analysis Maximum shear Stress Model No. Symmetrical bolted joint Unsymmetrical bolted joint Ave Bolt Shank Max 236 253 146 230 Results of Analytical calculation for all models considered for analysis are listed in tabular form as follows in Table no.5.2 Table 5.2 analytically determined stresses for all models under analysis Model prepared for analysis Symmetrical bolted joint Unsymmetrica l bolted joint t (mm) d (mm) Pi (N) τ max (MPa) 8 7 9940 253.56 8 7 9940 230.28 V. Discussion and Conclusion The discussion and conclusion on the basis of result is presented in this section. The experimental determination of breaking strength of symmetrical eccentric loaded bolted joint revealed the breaking stress is 253 MPa. The FE analysis of symmetrical eccentric loaded bolted joint for the same geometry revealed the maximum shear stress is in the range of 236 MPa to 253 MPa as shown in fig.2.10. This investigation revealed that the stress in the bolt calculated by experimentation & FE analysis are in close agreement, which validated the FE model of the eccentric loaded bolted joint considered for the analysis. The experimental determination of breaking strength of unsymmetrical eccentric loaded bolted joint revealed the breaking stress is 230.28 MPa. The FE analysis of unsymmetrical eccentric loaded bolted joint for the same geometry revealed the maximum shear stress is in the range of 146 MPa to 230 MPa as shown in fig.3.8. This investigation also revealed that the stress in the bolt calculated by experimentation & FE analysis are in close agreement, which validated the FE model of the eccentric loaded bolted joint considered for the analysis. From experimental and FE analysis of eccentrically loaded bolted joint using symmetrical and unsymmetrical bolt pattern as shown in fig.2.10 and fig.3.8, it is observed that bolts which are nearer to point of loading are heavily loaded, hence failure of that bolt takes place at the shank of the bolt. REFERENCES [1] Rados Bulatovic, JankoJovanovic An Analysis Of The Mathematical Models In The Deformation Process of Eccentrically Loaded Bolts Udc 621.315.684:519.87 (March-2000) [2] Dr.Saman Fernando The Function of Washers in Bolted Joint (Aug-2002) [3] Mahesh J. Patil, S.C. shilwant & Satish S. Kadam Self-Loosening of Bolted Joints :A parametric study (Jan-2006) [4] Aidy Ali, Ting Wei Yao, Nuraini Abdul Aziz Simulation And Experimental Work Of Single Lap Bolted Joint Tested In Bending Suranaree J. Sci. Technol.14 (4):331-345 (Nov-2007) [5] Mohamed Tahar, Nasraoui Jamel Chakhari, Boubaker Khalfi, Mustapha Nasri Numerical and Experimental Study of Shear Loaded Bolted Joint (June-2010) [6] Alex Selvarathinam, James Frailey, Jim Eisenmann 3d Finite Element Modeling Of Single-Lap Shear Bolted Joints (June- 2010)27th International Congress Of The Aeronautical Sciences [7] Janko D. Jovanovic Finite Element Analysis of Bolted Joint with Coarse and Fine Threads (Sep2010) [8] Nomesh Kumar, P.V.G. Brahamandam and B.V. Papa Rao 3D - Finite Element Analysis of Bolted Flange Joint of Pressure Vessel MIT International journal of Mechanical Engineering Vol.1, No.1, Jan 2011, PP 35-40 (Jan-2011) [9] Umran Esendemir & Ayse Ondurucu Comparison of Bolted Joint with two different clearance types (Aug2011) 37 P a g e