.. 000W Single Output Power Supply RSP-000 series SPECIFICATION MODEL OUTPUT INPUT PROTECTION FUNCTION ENVIRONMENT SAFETY & EMC (Note 4) OTHERS NOTE DC VOLTAGE RATED CURRENT CURRENT RANGE RATED POWER RIPPLE & NOISE (max.) Note. 50mVp-p VOLTAGE ADJ. RANGE VOLTAGE TOLERANCE Note. LINE REGULATION REGULATION SETUP, RISE TIME HOLD UP TIME (Typ.) VOLTAGE RANGE FREQUENCY RANGE EFFICIENCY (Typ.) AC CURRENT (Typ.) INRUSH CURRENT (Typ.) LEAKAGE CURRENT OVER Note.5 90 ~ 4VAC 7 ~ 70VDC OVER VOLTAGE.8 ~.8V 7 ~ 0.5V 7. ~.4V ~.5V 5. ~.V Protection type : Shut down o/p voltage, re-power on to recover OVER TEMPERATURE 85 J Ó 5 J (TSW ) detect on heatsink of O/P diode; 75 J Ó 5 J (TSW ) detect on heatsink of power transistor Protection type : Shut down o/p voltage, recovers automatically after temperature goes down ILIARY POWER() 5V @ 0.5A (+5%, -8%) REMOTE CONTROL Note. Power on : short between on/off(pin) & (pin) on Power off : open between on/off(pin) & (pin) on DC OK SIGNAL The TTL signal out, PSU turn on = 0 ~ V ; PSU turn off =. ~ 5.V OUTPUT VOLTAGE TRIM Note. Adjustment of output voltage is possible between ~ 0% of rated output CURRENT SHARING()Note.7 Please refer to function manual WORKING TEMP. -0 ~ + J (Refer to "Derating Curve") WORKING HUMIDITY STORAGE TEMP., HUMIDITY 0 ~ 90% RH non-condensing - ~ +85 J, 0 ~ 95% RH TEMP. COEFFICIENT VIBRATION EMC IMMUNITY MTBF RSP-000- RSP-000-5 RSP-000-4 RSP-000-7 RSP-000-48 V A 0 ~ A 70W 0 ~.5V Ó.0% Ó.0% Ó.0% Ó.0% Ó.0% Ó0.5% Ó0.5% Ó0.5% Ó0.5% Ó0.5% Ó0.5% Ó0.5% Ó0.5% Ó0.5% Ó0.5% 00ms, 50ms at full load ms/0vac 47 ~ Hz A/5VAC 5A/5VAC <.0mA / VAC ms/5vac at full load 8% 85% 88% 88% 90% A/0VAC A/0VAC 05 ~ 5% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed Ó 0.0%/ J (0 ~ 50 J) 5V 50A 0 ~ 50A 750W 50mVp-p.5 ~.5V POWER FACTOR (Typ.) 0.95/0VAC 0.98/5VAC at full load SAFETY STANDARDS WITHSTAND VOLTAGE ISOLATION RESISTANCE EMC EMISSION 0 ~ 500Hz, G 0min./cycle, min. each along X, Y, Z axes UL950-, TUV EN950- approved I/P-O/P:KVAC I/P-FG:KVAC O/P-FG:0.5KVAC.75K hrs min. MIL-HDBK-7F (5 J) ½ 4V A 0 ~ A 9W 50mVp-p 0 ~.4V I/P-O/P, I/P-FG, O/P-FG:00M Ohms / 500VDC / 5 J/ 70% RH Compliance to EN550 (CISPR), EN00--,- 7V 7A 0 ~ 7A 999W 50mVp-p 4 ~ 0V Compliance to EN00-4-,,4,5,,8,, EN5504, EN00--, EN4-, heavy industry level, criteria A 48V A 0 ~ A 008W 50mVp-p 4 ~ 55V DIMENSION 95*7*4mm (L*W*H) PACKING.95Kg; pcs/.7kg/.5cuft J File Name:RSP-000PEC 0-0-04
File Name:RSP-000PEC 0-0-04 000W Single Output Power Supply RSP-000 series Mechanical Specification 0.5 -M4 L= 77.7 5.4 7.8 Case No. 95B Unit:mm 4 95 4.5 8.5 59 7 SVR5 7 0 TB 90 -M4 L=4 Air flow direction 0.5 -M4 L= 5.4 77.7 7.8 AC Input Terminal Pin No. Assignment Pin No. Assignment Block Diagram I/P AC/N AC/L FG Derating Curve EMI FILTER Control Pi n No. Assignment () : HRS DF-DP-DS or equivalent Pin No. 4 ACTIVE INRUSH CURRENT LIMITING PFC CONTROL Assignment G- 5V- & PFC PWM CONTROL POWER Pin No. 5 7 8 Assignment DC-OK POWER SWITCHING O.L.P. FAN Pin No. 9 0, & FILTER CURRENT SHARE DETECTION CIRCUIT O.V.P. CONTROL & FILTER Assignment Static Characteristics Mating Housing HRS DF-DS or equivalent Terminal HRS DF-**SC or equivalent CURRENT SHARE DC OK V_TRIM PFC fosc : 0KHz PWM fosc : 90KHz POWER(5V/0.5A) 00 00 90 70 (%) 0 (%) 50-0 0 0 0 0 50 70 AMBIENT TEMPERATURE ( J) (HORIZONTAL) 90 95 00 5 4 INPUT VOLTAGE (VAC) Hz
File Name:RSP-000PEC 0-0-04 000W Single Output Power Supply RSP-000 series Function Description of Pin No. Function Description Positive sensing. The signal should be connected to the positive terminal of the load. The and leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. 4 5 7 8 9 0, G- 5V- DC_OK Negative sensing. The signal should be connected to the negative terminal of the load. The and leads should be twisted in pair to minimize noise pick-up effect. The maximum line drop compensation is 0.5V. Auxiliary voltage output ground. The signal return is isolated from the output terminals ( & ). Auxiliary voltage output, 4.~5.5V, referenced to pin (G-). The maximum load current is 0.5A. This output has the built-in oring diodes and is not controlled by the "remote control". Open collector signal, referenced to pin,(). Low when PSU turns on. The maximum sink current is 0mA and the maximum external voltage is 5.V. Turns the output on and off by electrical or dry contact between pin ( ) and pin (). Short: Power ON, Open: Power OFF. Current sharing signal. When units are connected in parallel, the pins of the units should be connected to allow current balance between units. Short connecting between (pin8) and (pin0) if output voltage trim function is not used. Connect to external DC voltage source for output voltage triming, referenced to pin (). Output voltage can be trimmed between ~ 0% of the rated output voltage. Connect to external resistor (/8W) for output voltage triming. Output voltage can be trimmed between ~ 0% of the rated output voltage. Please refer to function manual for details. These pins connect to the negative terminal (). Return for DC_OK Signal output. Function Manual."Remote " and "Output voltage trim" functions are not used. The power supply unit will have no output if the shorting connector (accessory comes along with the PSU) is not assembled. It contains two shorting wires : one is from (pin) to (pin) and the other is from (pin8) to (pin0). SVR5 TB + - G DC_OK Fig. (Shorting connector)
File Name:RSP-000PEC 0-0-04 000W Single Output Power Supply RSP-000 series.remote The PSU can be turned by using the "Remote " function Between (pin) and (pin) Output Status SW ON (Short) ON SW OFF (Open) OFF SVR5 TB G DC_OK + - Fig. SW.DC_OK signal "DC_OK" is an open collector signal. It indicates the output status of the PSU. It can operate in two ways : One is sinking current from external TTL signal ; the other is sending out a TTL voltage signal. - Sink current : The maximum sink current is 0mA and the maximum external voltage is 5.V. - TTL voltage signal : Between DC- OK(pin5) and (pin&) Output Status SVR5 TB 0 ~ V. ~ 5.V ON OFF Fig. G DC_OK 4.Remote Sense The remote sensing compensates voltage drop on the load wiring up to 0.5V. SVR5 TB (pin) + - (pin) Fig 4. Sense lines should be twisted in pairs G DC_OK
File Name:RSP-000PEC 0-0-04 000W Single Output Power Supply RSP-000 series 5.Output Voltage TRIM Output voltage of RSP-000 can be trimmed between % ~ 0% of its rated value by the following methods and &, & also need to be connected on : ()Using external voltage source between ""(pin9) and ""(pin) that is shown in Fig5. OUTPUT VOLTAGE (%) Vout 0 00 0 OVP 0%(Typ.) Non-Linear (Referenced to ) 4 5 EXTERNAL VOLTAGE (VDC) SVR5 G DC_OK TB External Voltage Fig 5. ()Connecting a resistor externally that in shown in Fig 5. & Fig 5. (A) O/P voltage goes down Vout 00 OUTPUT VOLTAGE (%) 90 70 50 Non-Linear G DC_OK 90 5 K K 4K7 open EXTERNAL RESISTOR ( [ ) R, /8W(Typ.) R Fig 5. (B)O/P voltage goes up Vout OVP 0%(Typ.) OUTPUT VOLTAGE (%) 0 05 00 Non-Linear G DC_OK R open 8K 7K5 EXTERNAL RESISTOR ( [ ) R, /8W(Typ.) Fig 5.
File Name:RSP-000PEC 0-0-04 000W Single Output Power Supply RSP-000 series.current Sharing with Remote Sensing RSP-000 has the built-in active current sharing function and can be connected in parallel to provide higher output power : ()Parallel operation is available by connecting the units shown as below. (, and are connected mutually in parallel). ()Difference of output voltages among parallel units should be less than 0.V. ()The total output current must not exceed the value determined by the following equation. (output current at parallel operation)=(rated current per unit) Ñ(Number of unit) Ñ0.9 (4)In parallel operation 4 units is the maximum, please consult the manufacturer for applications of more connecting in parallel. (5)The power supplies should be paralleled using short and large diameter wiring and then connected to the load. PSU PSU PSU PSU SVR5 TB SVR5 TB SVR5 TB SVR5 TB (pin7) (pin) (pin) Sense lines should be twisted in pairs Fig. G DC_OK G DC_OK G DC_OK G DC_OK Note : In parallel connection, maybe only one unit (master) operate if the total output load is less than 5% of rated load condition. The other PSUs (slaves) may go into standby mode and their output LEDs will not turn on.