Automated Orthogonal Control System for Electrospray Ionization Mass Spectrometry

Similar documents
The thin wall ESI tip appears unusually. advantageous for ensuring stable ESI. conditions and efficient ion transfers.

Ultrasensitive LC MS/MS: Agilent 6470 and 6495 LC-QQQ

Collision cell: Fragmentation efficiency > 90 % Duty cycle: Variable between 1 and 50 % (user selectable trapping time/scan time ratio) Transmission:

L E A D E R S I N F L O W T E C H N O L O G Y Q U A L I T Y P E R F O R M A N C E D E L I V E R E D P R O D U C T C A T A L O G

Agilent 6400 Series Triple Quadrupole LC/MS System

Improving the Collection Efficiency of Raman Scattering

Welcome! Denver, CO Houston, TX February 2009

Developing Droplet Size Test Methods in Nasal Sprays Products: How can the stable phase of the spray be selected and identified reliably?

TechnicalNOTE EVALUATION OF LCT PREMIER NEGATIVE ION MODE ESI EXACT MASS MEASUREMENT PERFORMANCE. Introduction. Objective

QUANTOF. High-resolution, accurate mass, quantitative time-of-flight MS technology

Mass Spectrometry and the Modern Digitizer

Agilent 6400 Series Triple Quadrupole LC/MS System

Supplementary Figure S1. Schematic representation of different functionalities that could be

Supplementary Information

Abstract No. 32. Arne Bengtson and Tania Irebo. Swerea KIMAB AB, Isafjordsgatan 28A, SE Kista, Sweden

Ultra High Definition LC/MS

BioInstrumentation Laboratory

Thorough Small Angle X-ray Scattering analysis of the instability of liquid micro-jets in air

LC/MS/MS. Page Header. triple quadrupole mass spectrometer.

Ion optics innovations for increased sensitivity in hybrid MS systems

SPRAY DROPLET SIZE MEASUREMENT

A New Conjoined RF Ion Guide for Enhanced Ion Transmission

Electrospray Diagnostics by Fourier Analysis of Current Oscillations and Fast Imaging

N-Methyl-1-(6-methylpyridin-2-yl)propan-2-amine

Advanced FTMS Data Acquisition and Processing

Cavity QED with quantum dots in semiconductor microcavities

Dynamic Nanospray Probe (NSI-1) Installation Guide

Thermo Scientific icap 7000 Plus Series ICP-OES: Innovative ICP-OES optical design

Xcalibur. LCquan. Tutorial. Quantitative Analysis of a Three-Drugs Data Set Software Version 2.8

Introduction of New Products

attocube systems Probe Stations for Extreme Environments CRYOGENIC PROBE STATION fundamentals principles of cryogenic probe stations

High-speed rotary bell atomization of Newtonian and non-newtonian fluids

Development of Control Algorithm for Ring Laser Gyroscope

Maximizing HPLC Speed and Resolution with the new 1100 DAD SL

LC/MS Purification System TRILUTION LC v3.0 User s Guide

A1. Experimental Setup

CRL MASS SPECTROMETRY FACILITY INSTRUMENT USER MANUAL MALDI MICRO. Operating Instructions. Basement Spec Lab:

.Sheath gas flow rate

Compressed-air flow control system

MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Development of a Low Cost, Low Power, Miniature Sector Mass Spectrometer with IonCCD Detection

MR-i. Hyperspectral Imaging FT-Spectroradiometers Radiometric Accuracy for Infrared Signature Measurements

Fabrication of Probes for High Resolution Optical Microscopy

Structural, optical, and electrical properties of phasecontrolled cesium lead iodide nanowires

Detection and Quantitation of Brominated and Chlorinated Hydrocarbons by DART with Linear Ion Trap and Triple Quadrupole Technology

Tunable wideband infrared detector array for global space awareness

Leading in Desktop SEM Imaging and Analysis

University of Wisconsin Chemistry 524 Spectroscopic Components *

Horiba LabRAM ARAMIS Raman Spectrometer Revision /28/2016 Page 1 of 11. Horiba Jobin-Yvon LabRAM Aramis - Raman Spectrometer

CSPADs: how to operate them, which performance to expect and what kind of features are available

Profiling of Volatile Organic Compounds in Milk and Orange Juice Using Headspace Analysis

EXPRIMENT 3 COUPLING FIBERS TO SEMICONDUCTOR SOURCES

Random lasing in an Anderson localizing optical fiber

Subsea Monitoring & Mapping

Automated MP Determinations

Practical work no. 3: Confocal Live Cell Microscopy

Nd:YSO resonator array Transmission spectrum (a. u.) Supplementary Figure 1. An array of nano-beam resonators fabricated in Nd:YSO.

Integrated into Nanowire Waveguides

Supporting Information. 8. Real-time qpcr using a Ds-containing primer and fluorophor-dpxtps (Figures S1-S3).

The Extrel MAX Systems are UHV-compatible flange mounted Quadrupole Mass

NanoSpective, Inc Progress Drive Suite 137 Orlando, Florida

Mass spectrometry (MS) is one of the most

Advanced Features of InfraTec Pyroelectric Detectors

Nano-100 Spectrophotometer. Brief introduction

Just where it s needed

Quantum frequency standard Priority: Filing: Grant: Publication: Description

FTA4000 Epson Ink Jetting

SR-80 EXTENDED AREA BLACKBODY

Conductance switching in Ag 2 S devices fabricated by sulphurization

Experimental Study of the Phenomenon of Droplet Impact upon a Liquid Surface

Performance Characterization Of A Simultaneous Positive and Negative Ion Detector For Mass Spectrometry Applications

MODULE I SCANNING ELECTRON MICROSCOPE (SEM)

Supporting Information

2.Components of an electron microscope. a) vacuum systems, b) electron guns, c) electron optics, d) detectors. Marco Cantoni 021/

RESEARCH ARTICLE. A High Voltage Power Supply That Mitigates Current Reversals in Capillary Zone Electrophoresis-Electrospray Mass Spectrometry

High resolution cavity-enhanced absorption spectroscopy with a mode comb.

A Narrow-Band Tunable Diode Laser System with Grating Feedback

DROPLET SIZE DISTRIBUTION MEASUREMENTS OF ISO NOZZLES BY SHADOWGRAPHY METHOD

User s Manual for Integrator Short Pulse ISP16 10JUN2016

Advantages of Multi-Turn-TOF Technology

SCANNING ELECTRON MICROSCOPY AND X-RAY MICROANALYSIS

In-Vivo IMAGING SYSTEMS. A complete line of high resolution optical & X-ray systems for pre-clinical imaging

True simultaneous ICP-OES for unmatched speed and performance

Mitos Dropix Droplet Generation System

Hyperspectral Imaging Basics for Forensic Applications

Residual Gas Analyzers

Improving Signal-to-Noise by Identifying Sources of Noise in Mass Spectrometer Systems

Performance Comparison of Spectrometers Featuring On-Axis and Off-Axis Grating Rotation

Kit for building your own THz Time-Domain Spectrometer

Roger Bardsley, Applications Chemist; Teledyne Tekmar Page 1

Supporting Information (including Experimental Details and 4 Supplement Figures)

FTMS Booster X1 High-performance data acquisition system for Orbitrap FTMS

The Development of a Novel Electron Multiplier with an Onboard Integral High Voltage Power Supply for use in Mass Spectrometers

Electron Multipliers. Introduction to ETP Electron Multipliers Selection by Technique: LC-MS 242

DEVELOPMENT AND APPLICATION OF NON-TAPERED ELECTROSPRAY EMITTERS FOR NANO-ESI MASS SPECTROMETRY

OPTOFLUIDIC ULTRAHIGH-THROUGHPUT DETECTION OF FLUORESCENT DROPS. Electronic Supplementary Information

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

REAL-TIME DUST MONITOR FOR INDOOR AIR QUA- LITY MEASUREMENTS AND WORKPLACE EXPOSURE ASSESSMENTS FIDAS

Scanning Electron Microscopy Basics and Applications

Automatic optical measurement of high density fiber connector

Transcription:

utomated Orthogonal Control System for Electrospray Ionization Mass Spectrometry Gary. Valaskovic 1, James P. Murphy III 1, Mike S. Lee 2 1 New Objective Inc, Woburn, M 2 Milestone Development Services, Newtown, P Introduction Low flow rate ESI (nanospray) demonstrates impressive figures of merit for sensitivity. When compared with conventional ESI (ml/min), however it suffers from a decreased robustness and reproducibility. Much of this behavior appears to be a result of the large number of spray modes possible at low flow rates. The liquid and spray emitting for a tip may take on a wide variety of physical forms referred to as spray modes. The specific spray mode is highly dependent on the geometry of the emitter, the strength and shape of the electric field, flow rate, and the physiochemical characteristics of the mobile phase. These spray modes generate droplets of differing size and charge to mass ratio. Many modes are oscillatory, exhibiting pulsed droplet generation. The most effective spray mode for producing droplets suitable for ESI-MS is the cone-jet spray mode. stable, non-pulsing Taylor cone is formed, resulting in a stable ion current. Optimization for this mode can be difficult with gradient chromatography because mobile phase characteristics such as surface tension, viscosity and flow rate change. One set of ESI tuning conditions is unlikely to yield a stable spray mode throughout an LC gradient. s a result compromises are often made, such as addition of sheath gas or operating at higher than optimal voltage. The resulting spray instabilities can shift charge state distribution and increase the relative standard deviation of ion current. Methods In an effort to make nanospray easy to use and more robust a self-tuning nano-esi source system has been developed. The electrospray plume is directly monitored orthogonal to the mass spectrometer rather than the traditional ion current. Figure 1 - () System configuration on an LCQ Deca (Thermo Electron) (B) Schematic of the spray analysis and orthogonal control system The implementation of a feedback loop results in a self-adjusting system (Figure 1). The system uses a video microscope equipped image acquisition computer to characterize the spray and determine the spray mode. control algorithm then adjusts the applied voltage so that a desirable spray mode is obtained and maintained throughout the chromatographic analysis. B 1

PicoView nanospray source (New Objective) connected to an LCQ Deca (Thermo Electron) was used to test the self-tuning system. Voltage was provided to the source by a high-voltage power supply (Stanford Research Systems Inc.) controlled by a GPIB interface. fiber optic bundle connected to a 15W tungsten-halogen illuminator provided intense illumination. CCD camera based video microscope, positioned orthogonal to the ESI emitter, fed images into a PC equipped with a frame capture board. n image analysis and high voltage control algorithm was written in the LabView (National Instruments) programming environment. The electrospray voltage was under full control of the host PC and was completely uncoupled from a mass spectrometer. Software Spray mode determination is based on image morphology using edge detection and location within predefined areas surrounding the emitter called regions of interest (ROI) (Figure 2). Figure 2 - Geometry of the four regions of interest (ROI) zones used by the image analysis algorithm Table 1 - nalysis of the zones established in Figure 2 for different spray modes user friendly software platform was created to control the spray analysis algorithm. Screen captures of several steps from the program are displayed in Figures 3-5. The software will recognize a nanospray emitter anywhere in the field of view of the camera (Figure 3). By locating the tip of the emitter, the ROI can be properly placed with a minimal amount of effort (Figure 4). Upon system activation a voltage ramping up procedure facilitates spray formation, eliminating any droplets which may have formed at the tip. The system continues to increase the applied voltage until edges area detected in zones one and two. t that point the spray mode analysis is activated (Figure 5). The detection of dripping or spindle spray modes cause the applied voltage to be raised; multi-jet or multispindle modes cause the voltage to be lowered. If a stable cone jet is detected the voltage is unchanged. droplet detector alerts the user if liquid is collecting on the emitter. 2

Zone 1 - Probes the area corresponding to the cone-jet transition Zone 2 - Positioned further away from the emitter probes the middle jet region Zones 1 and 2 establish the number of jets or streams emitted Zone 3 - Positioned along the leading area of the plume distinguishes between large droplets and plume formation Zone 4 - Confirms the presence of large droplet emissions Each spray mode has an identifying characteristic in each of these four regions. In one algorithm the mode can be determined by counting the number of edges in each ROI (Table 1). Figure 3 - The nanospray tip is automatically located and information such as tip distance and angle are displayed Figure 4 - The ROI are defined by the user in the automatic controls tab Figure 5 - Spray analysis of the multijet mode. The number of edges in each ROI and with the plume angle are shown in the readout tab 3

Results Relative bundance () 1% CN, 5 nl/min 1 NL: 3.17E6 S 8 21 V 6 4 2 4 6 8 1 12 1 NL: 2.1E6 P/M 8 28 V 6 4 2 4 6 8 1 12 (B) 1% CN, 7 nl/min 1 8 6 4 2 1 8 6 4 2 NL: 8.14E6 M/S 21 V 4 6 8 1 12 NL: 5.5E6 R 28 V Relative bundance (C) 7% CN, 5 nl/min 1 8 6 4 2 1 8 6 4 2 4 6 8 1 12 (D) 7% CN, 7 nl/min 1 8 6 4 2 1 8 6 4 2 NL: 8.64E6 C 13 V 4 6 8 1 12 NL: 5.42E6 M 3 V NL: 7.62E6 S 13 V 4 6 8 1 12 NL: 9.79E6 M/R 3 V 4 6 8 1 12 4 6 8 1 12 Figure 6 - Full scan mass spectra (summed, n=1) of a five peptide angiotensin mixture (5 femtomole/peptide/µl, 1% and 7% CN). The spray image for each spectrum is shown in the inset. () Flow rate of 5 nl/min with emitter voltages of 21 V and 28 V. (B) Flow rate of 7 nl/min with emitter voltages of 21 V and 28 V. (C) Flow rate of 5 nl/ min with emitter voltages of 13 V and 3 V. (D) Flow rate of 7 nl/min with emitter voltages of 13 V and 3 V. The letter in the upper right hand corner of the spray image indicates the spray mode observed (S=spindle, P/M= pulsed multi-jet, M/S=multi-spindle, R=ramified jet). The (M+H), (MH), and (MH) molecular ions are denoted with,,, respectively; denotes adducts. The base peak ion intensity for each spectrum is shown to the left of each plume image. 15 µm fritted tip was used. 19 V 19 V 19 V 1 8 Figure 7 - Nanospray response to a single voltage across a gradient (top, orange), and an optimized voltage across a gradient (bottom, green) % CN 6 4 2 2 4 6 8 1 12 14 16 18 Time (min.) 21 V 15 V 4

# 28-292 RT: 4.87-5.8 V: 13 NL: 1.26E7 T : + c ms [ 35.-15.] 1 458.1 759.3 76.4 4 5 6 7 8 9 1 11 12 13 14 15 RT: 2. - 35. SM: 3B 1 NL: 4.67E7 95 9 85 8 Relative bundance 75 7 65 6 Relative bundance 55 5 45 4 35 3 25 2 15 1 5 2 4 6 8 1 12 14 16 8 1 2 22 24 26 28 3 32 34 Time (min) 1 µl Injection of a BS digest (5 fmol/µl) using the automated control system across a 4-minute gradient. The optimal voltage ranged from 235 V to 19 V across the gradient, maintaining a stable and consistent spray. Inset: Full-scan MS, T=4.9-5.1 min. Note the high signal-to-noise for early eluting peptides. Conclusions System operation on a nanospray equipped, ion-trap mass spectrometer has been demonstrated t or near the limit-of-detection optimal mass spectra correlate with particular spray modes (spindle and cone-jet preferred) The control system responds to changes in flow rate and/or mobile phase composition, maintaining optimal spray modes automatically Peak-parking experiments are readily optimized, providing both micro- and nanospray flow rates (see posters WPN-264 and ThPV-446 for more information) Control software automaticaly finds the tip, and guides user to proper set-up conditions (angle, distance) for improved repeatability Operation is unattended, enabling extended-time nanospray experiments cknowlegements The authors would like to acknowledge Jeff Jensen, Karen Hahnenberger and the team at Eksigent Technologies for the generous use of the NanoLC pumping system. Originally presented at the 52nd Conference of the merican Society of Mass Spectrometry, 24 24 New Objective, Inc. ll rights reserved. ll trademarks and registered trademarks are properties of their respective companies. 5