FEI Quanta 200 ESEM Basic instructions

Similar documents
1.1. Log on to the TUMI system (you cannot proceed further until this is done).

Scanning Electron Microscope FEI INSPECT F50. Step by step operation manual

1. Preliminary sample preparation

JEOL 6500 User Manual

JSM 6060 LV SCANNING ELECTRON MICROSCOPE STANDARD OPERATING PROCEDURES

JEOL 6700 User Manual 05/18/2009

Basic Operating Instructions for Strata Dual Beam 235 FIB/SEM

Using the Hitachi 3400-N VP-SEM

Fire CR Calibration Guide

RAITH e-line OPERATING INSTRUCTIONS

Figure 1 The Raith 150 TWO

Standard Operating Procedure for the Amray 1810 Scanning Electron Microscope Version: 29 NOVEMBER 2014

1. Specimen Holder Removal, Loading, and Insertion

Check that the pneumatic hose is disconnected!!!! (unless your using the BSE detector, of course)

Title: Amray 1830 SEM#2 Semiconductor & Microsystems Fabrication Laboratory Revision: D Rev Date: 03/18/2016

SEM Training Notebook

University of Minnesota Nano Fabrication Center Standard Operating Procedure Equipment Name:

Operating Checklist for using the Scanning Electron. Microscope, JEOL JSM 6400.

SEM Training Notebook

2. Now you need to create permissions for all of your reviewers. You need to be in the Administration Tab to do so. Your screen should look like this:

OPERATION OF THE HITACHI S-450 SCANNING ELECTRON MICROSCOPE. by Doug Bray Department of Biological Sciences University of Lethbridge

Protective Equipment Nitrile gloves for handling sample holder and safety glasses for filling liquid nitrogen dewar.

Standard Operating Procedure

Zeiss AxioImager.Z2 Brightfield Protocol

Dickinson College Department of Geology

JEOL JEM-1400 Transmission Electron Microscope Operating Instructions

This procedure assumes the user is already familiar with basic operation of the SEM and the MiraTC interface.

Amray 3600 FESEM. Standard Operating Procedure. v2.2 modified by Bryan Cord. General Notes...3. Sample Loading...5. System Loading...

ALTURA EDS. Rev. 0915

1.2. Make sure the viewing screen is covered (exposure to liquid N 2 may cause it to crack).

ZEISS EVO SOP. May 2017 ELECTRON OPTICS

Operating Checklist for using the Scanning Electron Microscope, JEOL JSM 6400.

Basic Users Manual for Tecnai-F20 TEM

SCIENTIFIC INSTRUMENT NEWS. Introduction. Design of the FlexSEM 1000

Full-screen mode Popup controls. Overview of the microscope user interface, TEM User Interface and TIA on the left and EDS on the right

Sony Soloist will allow you to do all of these same operations digitally, that is to say, on a computer & without a cassette!

KEYENCE VKX LASER-SCANNING CONFOCAL MICROSCOPE Standard Operating Procedures (updated Oct 2017)

Instructions for Tecnai a brief start up manual

Scanning Electron Microscope in Our Facility

General information. If you see the instrument turned off, notify MIC personnel. MIC personnel will help you insert your samples into the instrument.

A step-by-step process for attaching a photo of the park through Android Mobile Application

Zeiss LSM 880 Protocol

Zeiss LSM 780 Protocol

Faculty Lecture Capture Guide

Operation Guide. Hitachi S-3400N. Variable Pressure Scanning Electron Microscope. with. Deben Peltier Coolstage

Please follow these instructions for use of the Philips CM100 TEM. Adopted from website below.

Model SU3500 Scanning Electron Microscope

SEM OPERATION IN LOW VACUUM MODE

Instructions for Making On-Line Reservations for Microscopes in NB11-204

FEI Tecnai G 2 F20 Operating Procedures

Nikon SIM-E & A1-R System

COMPACT MANUAL FOR GI USERS OF THE JEM 1400 FLASH BEGINNERS (For internal use only) Gray means additional information at the end of this mini-manual

Operating the Hitachi 7100 Transmission Electron Microscope Electron Microscopy Core, University of Utah

Olympus LEXT OLS 4000 Confocal Laser Microscope

RENISHAW INVIA RAMAN SPECTROMETER

Reviewing Your Tax Return In Your Portal

Eduphoria Guide To Create a Test

Olympus xcellence Software - basic user guide

Omniverse Setup Instructions

Leica DMi8A Quick Guide

Using the Desktop Recorder

Image Editing and Measurement Software. User Manual

Zeiss Deconvolution Microscope: A Quick Guide

To start a new drawing Select File New then from the dialog box, which appears select Normal.dft followed by OK.

MAKE SURE YOUR SLIDES ARE CLEAN (TOP & BOTTOM) BEFORE LOADING DO NOT LOAD SLIDES DURING SOFTWARE INITIALIZATION

INFORMATION & COMMUNICATION TECHNOLOGIES CLASSROOM TECHNOLOGY

10.2. Scanning Document Camera Scoring. Page 1 of 5. How do I score answer sheets using a document camera? STEP 1

CAPTURING IMAGES ON THE HIGH-MAGNIFICATION MICROSCOPE

How to Start Your Own Fundraising Page

The user should already be familiar with operation of the instrument in STEM mode, use of the Microscope Control interface, and TIA.

Manual Stitching of Multiple Images to Produce a Panorama

Using the Nikon TE2000 Inverted Microscope

Training Guide for Carl Zeiss AxioZoom V16 Stereo Microscope

Version SmartPTT Enterprise. Web Client User Guide

Logging into Five9 Telephony

ScanGear CS-U 5.6. for CanoScan FB1210U Color Scanner. User s Guide

Operation Guide for the Leica SP2 Confocal Microscope Bio-Imaging Facility Hunter College October 2009

Scanning Electron MICROSCOPES. SEM-20/30, TableTop SEM-20. The Wise SEM for Your Application

Operating Procedures for MICROCT1 Nikon XTH 225 ST

AxioVision 4.5 Brightfield Image Capture Procedure

EinScan-SE. Desktop 3D Scanner. User Manual

How to Present External Audio Stimuli from PC - Focusrite Soundcards

Introduction to Scanning Electron Microscopy

G E O S E R V E R I N S TA L L

WITec Alpha 300R Quick Operation Summary October 2018

FE-SEM SU-8020 Operating manual (Preliminary version)

Imaging Processing with Pax-it Software (Analyzing the Percentage of Carbon Content)

Standard Operating Procedure Hitachi UHR CFE SU8230 SEM

SOP: EDAX Eagle III Microspot XRF

CONTENTS. 1. OBJECTIVE p INTRODUCTION AND MATERIALS p PREPARATION DRAWING p 2

An easy user guide AN EASY USER GUIDE

User Guide for TWAIN / DirectX interface for GRYPHAX USB 3.0 cameras

Guide to Operating the Bruker FT-IR Microscope I. Basic Spectrum Acquisition with Vertex 70

2 How to operate the microscope/obtain an image

Progeny Imaging Veterinary

Schottky Emission VP FE-SEM

Contents STARTUP MICROSCOPE CONTROLS CAMERA CONTROLS SOFTWARE CONTROLS EXPOSURE AND CONTRAST MONOCHROME IMAGE HANDLING

HP DesignJet T520. Quick Start Guide. Copyright Notice

LEO 912 TEM Short Manual. Prepared/copyrighted by RH Berg Danforth Plant Science Center

OPERATING INSTRUCTIONS

Transcription:

FEI Quanta 200 ESEM Basic instructions Desktop and then start the UI. If the computer has restarted and you need to login, Username: supervisor and Password: supervisor Log-in to the Microscope using the following- Username: supervisor Password: QuantaD8376 Vent the chamber by clicking on the VENT button to right side of the window Insert you sample into the chamber in the same method as the XL30 SEM. Using the Elephant Trunk make sure that your sample is less than 10mm Determine the type of sample you have and select the appropriate vacuum conditions you will use. High Vacuum for normal conductive sample and low Vacuum for soft or and uncoated non conductive samples. 1

You may now select the vacuum condition for your sample (High Vacuum, Low Vacuum, ESEM) Then press PUMP. Vacuum buttons Next, select the right acceleration voltage from the pull down tab located just below the menu bar. Once the proper pressure has been achieved, the chamber ICON in the lower right side of the screen will be fully green. 2

Turn on the Beam by clicking on the BEAM ON button The display should look like this. Scan speed control Pause release button Top left SE image, Top right Backscatter, Bottom Left is the combined SE and Backscatter image and the Bottom right is the chamber view scope. Activate up to three displays at one time by selecting the display and the click on the pause release button. The display will start to scan. To increase and decrease the scan speeds use the arrow up and down next to the turtle or the rabbit. 3

While viewing the chamberscope (bottom right screen) press and hold the scroll wheel button and push the mouse upward to position your sample near the 10mm mark on the screen. It may be necessary to un pause the chamberscope screen first. Increase the Magnification and focus the SE image by using the USER interface panel shown below. F7 displays a reduced screen for easer real time adjustments. F5 enlarges the active screen to fit the entire window. Once the image is focused link the Z to FWD by clicking on the ICON on the tool bar Next select the Navigation Page by clicking on the text PAGES top right corner of the display. For most operations it is recommended that a Z value of 10mm is now set as the working distance. Increase magnification to at least 1k (higher the better) and focus the image as well as you can. Next select the Beam Control Page and start the Lens align by clicking on the LENS ALIGN button. 4

While observing the image, place you mouse over the small square box in the Lens Align and hold it down. Move the mouse and box within the field to reduce movement in the image. Turn of the Lens Align by clicking on the Lens Align button once more. Refocus you image and increase the Magnification to above 20k ( the higher the better) and using the User Interface Panel, Stigmate the image using the X and Y controls for sharpest image possible. F7 displays a reduced screen for easer real time adjustments. F5 enlarges the active screen to fit the entire window. When using the Low Vac mode, it may be necessary to adjust the pressure in the chamber for a high contrast image. Simply adjust the pressure until the appropriate contrast has been achieved. In most cases pressure between.83 and.53 Torr will work well. 5

Taking and Saving an Image: Once the desired image is achieved, select the camera button on the tool bar to take a picture. Once the scan has stopped a default directory will appear in the Shared Data Folder (PRZ- HTYXWG\Quanta shared data folder). Store your images in the Shared Folder only. Data will be store on the computer on the left side of the operator s consol. If the images are saved correctly in the shared data folder on SEM computer, you should be able to find your data in the shared data folder for Quanta on the computers outside the Quanta room. File transfer is allowed on these computers. Warning!!! Never leave the ESEM in the LOW VAC or ESEM mode, always return the SEM to the HIGH VAC Mode. Emergency Information: Medical Emergencies: Contact 911 and Public Safety (609) 258-1000 Room / facility emergencies: Contact Public Safety (609) 258-1000 Issues related to the instrument: 1. Contact IAC Staff. 2. Leave system as is, Do Not disable vacuum system. 3. Try to shut off the High Tension. Audible/Siren Emergency Alerts: Follow previous steps 2 & 3 and leave the building. Emergency Contact Information: Nan Yao: Office (609)258-6394; Cell (908) 922-2236 Email: nyao@princeton.edu John Schreiber: Office (609)258-0034; Cell (215) 431-4670 Email: js51@princeton.edu Paul Shao: Office (609)258-3851; Cell (847) 721-086 Email: pshao@princeton.edu 6