Operation Manual. SWF Series Switch Mode Power Supply. SANKEN ELECTRIC CO., LTD No.PAN E-01.

Similar documents
Sample Test Data SWF Series SWF100P W, High Surge Tolerant, Low Noise Power Supply

MODEL LEP100F-24 LEP100F-36 LEP100F-48 VOLTAGE[V] AC f or DC

J SERIES JBW. Wide input, compact and device-embedded type

For more information, please visit the product page. output. output current max (A)

AC/DC Power Supply Single-Output

VMS-300A - XX - XXX - X

VOF XX - XXX - X

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

ZWD100PAF. Conformity to RoHS Directive

ZWD100PAF. Conformity to RoHS Directive

150 Watt Industrial (WLT)

MODEL GHA300F-12 GHA300F-24 GHA300F-48 VOLTAGE[V] AC f (output derating is required at AC90V -115V *3) CURRENT[A]

The MBC550 range is ideally suited to a wide variety of medical applications, and also where airflow is limited or not available.

MODEL GHA300F-12 GHA300F-24 GHA300F-48 VOLTAGE[V] AC f (output derating is required at AC90V -115V *3) CURRENT[A]

These power supplies are ideal for medical, telecom, datacom, industrial equipment and other applications.

Electrical Specifications VAC/390 VDC, Universal (Derate from 100% at 115VAC to 78% at 90VAC)

1500W Programmable Single Output AK V. 48V Rated Current. 31.3A Current Range 100A. 0~31.3A Rated Power 0~100A 1500W

60W 75W 80W 81.6W 81W 82.8W 81.9W 81.6W 81W

80W Single Output Switching Power Supply

BR V, 1 A Non-Isolated Step Down DC/DC Converter Module BR300. Features and Benefits. Description. Applications: Typical Application Circuit

CURRENT1[A] CURRENT2[A]*

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

CS Series. Compact, Cost-effective, High Reliability Switching Power Supply. TDK-Lambda Introduces CS series

ECP225-A Series. 225 Watts. AC-DC Power Supplies. Models & Ratings

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

SPECIFICATION FOR APPROVAL

SI-3010KM. Linear. Regulators. 1 A, Low-Dropout, 1.0~16 V Regulator

These medical power supplies are ideal for monitoring, home health equipment as well as surgical devices.

Basic Characteristics Data

MODEL ADA600F-24 ADA600F-30 ADA600F-36 ADA600F-48 VOLTAGE[V] AC f or DC (AC64 or DC90 optionally available *6) FREQUENCY[Hz]

NLP65 SERIES 75 Watt Open Frame Power Supply Measures: 5.00 x 3.00 x 1.26

3000W Single Output Power Supply AK V 200A. 0 ~ 200A 3000W 150mVp-p

WIDE SELECTION OF LINE UP RANGE FROM GENERAL INDUSTRIAL, MEDICAL, HEAVY DUTY TO POWER SUPPLY WITH PEAK OUTPUT HWS

MODEL ADA600F-24 ADA600F-30 ADA600F-36 ADA600F-48 VOLTAGE[V] AC f or DC (AC64 or DC90 optionally available *6) FREQUENCY[Hz]

1. Output Power vs. Ambient temperature a. 3.3 and 5 V models b. All other models. Load factor Convection

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

The MDU150 Series provides the same benefits as the MPU150 Series, with nominal 48 volt DC input.

AC/DC Power Supply Series APPLICATION NOTE

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE 370W+370W

SI-8050JD. Switching Regulators. Step-Down to 5.0 V, 1.5 A, DC/DC Converter

420 W High Line Output Power. Rugged Industrial Construction. -40 C to +70 C Operation. 5 V Standby. Screw Terminals. SEMI F47 Compliant

Electrical Specifications

800W Single Output Power Supply

American Power Design, Inc.

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

NEMIC-LAMBDA SWS Series INSTRUCTION MANUAL

SE014S110 Power Module; dc-dc Converter: 48 Vdc Input, 110 Vdc Output, 14 W

3000W Single Output Power Supply AK V 24V 250A 200A 125A 0 ~ 250A 0 ~ 125A 3000W 0 ~ 200A. 3000W 150mVp-p 3000W

TB65 65W Single Output Test and Measurement/Industrial Series

1500W Single Output Power Supply AK V 100A 0~100A 1500W. 150mVp-p. Adjustment of output current is between 40 ~ 105% of rated output

LB115S 115W Single Output

American Power Design, Inc.

NLP40 SERIES 50 Watt Open Frame Power Supply Measures: 4.25 x 2.50 x 1.15

SPECIFICATION SWITCHING POWER SUPPLY SINGLE POWER 250W BEST POWER SOLUTIONS, INC. 9F, NO.196-7, SEC.3, TA-TUNG RD SHI CHIH, TAIPEI, TAIWAN, R.O.C.

Electrical Specifications

SI-8050JD. Regulators. Step-Down to 5.0 V, 1.5 A, DC/DC Converter. SANKEN ELECTRIC CO., LTD.

DLP/E Series Instruction Manual

These medical power supplies are ideal for, monitoring, home health equipment as well as surgical devices.

3 line sine wave EMC output filters for converters and power electronics

Precautions in Using the product:

RKE SERIES Single phase input / single output 1500W

Asia-Pacific North America Europe, Middle East Bel Power Solutions, Inc. BCD.

Metal Case Power Supplies

Description. Applications: Typical Application Circuit V PG (5 V) BR202/203. ON/OFF VS+ Power Good VOUT VIN RTRIM GND C IN R TRIM

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

These power supplies are ideal for telecom, datacom, industrial equipment and other applications.

SPECIFICATION SWITCHING POWER SUPPLY BPS-300SP/2U 6-OUTPUT WITH ACTIVE PFC FUNCTION SINGLE POWER 300W BEST POWER SOLUTIONS, INC.

BR301 SANKEN ELECTRIC CO.,LTD. 3.3V 1A Non-insulation step down type DC/DC converter module

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

REVISIONS 06/26/06 YS TEMPS FILE NAME: CAD1:MSWORD:PA DOC SCALE: NONE REV: D SH 1 OF 7 TITLE: OVS-U (UNIVERSAL INPUT) SERIES SPECIFICATION

Model Number Structure. Ordering Information. Solid-state Power OFF-delay Timer H3DE-H. Model Number Legend. List of Models

ECC100 Series. -40 ºC to +75 ºC Operation. 100 W - Baseplate Cooled. High Efficiency Resonant Topology. Screw Terminals Available.

Electrical Specifications

Output Voltage* (nom.)(adjustable)

Electrical Specifications

AC/DC Power Supply Series APPLICATION NOTE

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

MB120S 120W Single Output Medical Series

AC/DC Power Supply Series APPLICATION NOTE

LDC240 Series is a single phase, ultra compact DIN Rail Switching Power Supply with active PFC, ideal for many applications.

Package TO3P-3L. T C = 25 C 40 A T C = 100 C 20 A PW 1ms Duty cycle 1 % PW 1ms Duty cycle 1 % T C 125 C Refer to Figure 1

SPECIFICATIONS (CONVECTION COOLING)

PDAM500 Series 500W Power Supply

Description. Applications: Typical Application Circuit. V PG (5 V) BR200 ON/OFF VS+ Power Good VIN RTRIM GND C IN R TRIM

HWS SERIES HWS HWS HWS HD HWS ME HWS-P. Instruction Manual. No.14-M95 (HWS300,600 24Vout only)

Description. Applications: Typical Application Circuit BR205 ON/OFF VS+ VOUT VIN RTRIM GND R TRIM

All specifications valid at normal input voltage, full load and +25 C after warm-up time unless otherwise stated.

Electrical Specifications

CLP0205 Open Frame Power Supply Vac input; 5Vdc output; 200W Output Power; 0.25A stdby

General. Environmental. EMC & Safety

Medical Safety Approvals (-M versions) Industrial Heavy Duty Terminals. Output Power up to 1500 W. High Power Density - 18W/in 3

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

LZS-A500-3 POWER SUPPLY Installation, Operation, and Maintenance Manual. IM-LZSA500-3 January 2008 Revision H

AC/DC Power Supply Series APPLICATION NOTE

SPECIFICATION REDUNDANT POWER SUPPLY HOT-SWAPPABLE BPS-460RDX 6-OUTPUT 460W+460W BEST POWER SOLUTIONS, INC.

Model Number Output V1/V2/V3 Output I1/I2/I3 max. Ripple & Noise Efficiency(min/nom) Capacitive Load

Doc. EA Model Number:

3 x 2 x 0.75 Inches Form factor. PCB Mount option available. 40 Watts Convection. Approved to EN/IEC Efficiencies 85% Typical

LDW25-24 is a single or two phase AC or DC input DIN Rail Switching Power Supply.

CLP0224 Open Frame Power Supply Vac input; 24Vdc output; 200W Output Power

Transcription:

Operation Manual SWF Series Switch Mode Power Supply 1

Table of Contents Safety Precautions 3 Appearance and Meaning of Safety Warnings 4 Hazard and Caution Safety Warnings 4 Introduction to SWF Series 6 Product Models 7 Model SWF050P-24 7 Model SWF100P-24/-36/-48 9 Model SWF150P-24/-36/-48 11 Model SWF240P-24/-36/-48 13 Model Number Description 17 Input and Output Terminals, Connectors, and Pin Assignments 18 Functional Description 20 Dynamic load 20 Remote on/off control 20 Installation 21 Electrical clearance air space 21 Mounting 22 Derating 23 Specifications and Standards 24 Model SWF050P-24 24 Model SWF100P-24/-36/-48 26 Model SWF150P-24/-36/-48 28 Model SWF240P-24/-36/-48 30 This paper is prepared as of and subject to change without notice. 2

Safety Precautions Be sure to observe the precautions explained below. 1. Be sure to read this complete document and the detailed specifications of the individual products in the product series before using the product. 2. The products should be handled only by persons who have competent electrical knowledge. 3. The products are DC stabilized power supplies with special structures created for mounting inside of protective electrical device enclosures. Use only when properly mounted in protected device enclosures. 4. Although Sanken strives to improve the quality and the reliability of the products, please implement safety designs that comply or exceed all industry standards and all of the regulatory requirements of the jurisdictions where the products will be used. Safety designs for use of the products are the responsibility of the customer or user. The customer or user has the responsibility not to endanger human life or health, or to damage property due to malfunction and/or failures of the products when using them. 5. When considering use of the products for the following equipment and applications, for which there is enhanced risk that the products could endanger human life or affect property maintenance or public functions, be sure to secure sufficient fail-safe functionality of the customer or user devices by means of system redundancies and other methods: Medical equipment, etc. that could directly endanger human life Electric trains and other conveyances such as elevators, etc. that could result in personal injury Vehicles and vessels, etc. that could be affected by vibration or shock Traffic systems, etc. that could exert an important influence on society and the public Any other applications and equipment similar to those mentioned above. 6. Be sure to observe the items below: Do not disassemble, repair, or modify these products. Do not touch inside of the products because of high voltage. Use the products within the specified input voltage, frequency, output voltage, and output current ranges. Be sure to observe designated ambient environment conditions, such as ambient temperature and relative humidity. Each product model has a designated method for installation and mounting. Observe installation and mounting instructions. 3

Appearance and Meaning of Safety Warnings In this document, the levels of safety warnings are divided into two categories, Hazard and Caution. Be sure to observe the safety precautions indicated on the product and in documentation by symbols and text. The general meaning of symbols is as follows: Hazard and Caution Safety Warnings General Cautionary Notices 4

Other Precautions 5

Introduction to SWF Series General Description The SWF series are compact, wide ranging power supplies, providing peak power capability that supports twice the rated output, making them ideal for motorized applications. They offer low noise and high efficiency by current resonant circuitry. Features and Benefits Supports peak loading, two times the rated current (maximum of 10 seconds) World wide input (85 to 264VAC) Provides high efficiency and low noise via current switching technology Acquired CE marking for Low Voltage Differential Conductive emission class B (VCCI class B, FCC class B, EN55022 class B) Safety standards: UL60950-1, C-UL (CSA60950-1), SEMKO (EN60950-1) Options: remote on / off control, chassis, cover, terminal stand (SWF240P only) Model shown with optional chassis and cover, screw terminals option available for 240W unit Models shown without optional chassis and cover 50W Output 100W Output 150W Output 240W Output 6

Product Models Model SWF050P-24 Output Power: 50W, Output Voltage: 24V Circuit Assembly Only Weight: 160 g 7

Model SWF050P-24 (continued) Output Power: 50W, Output Voltage: 24 V Circuit Assembly with Chassis (L option) Circuit Assembly with Chassis and Cover (LC option) 8

Model SWF100P-24/-36/-48 Output Power: 100W, Output Voltage: 24V / 36V / 48V Circuit Assembly Only Weight: 300 g 9

Model SWF100P-24/-36/-48 (continued) Output Power: 100W, Output Voltage: 24V / 36V / 48V Circuit Assembly with Chassis (L option) Circuit Assembly with Chassis and Cover (LC option) 10

Model SWF150P-24/-36/-48 Output Power: 150W, Output Voltage: 24V / 36V / 48V Circuit Assembly Only Weight: 400 g 11

Model SWF150P-24/-36/-48 (continued) Output Power: 150W, Output Voltage: 24V / 36V / 48V Circuit Assembly with Chassis (L option) Circuit Assembly with Chassis and Cover (LC option) 12

Model SWF240P-24/-36/-48 Output Power: 240W, Output Voltage: 24V / 36V / 48V Circuit Assembly Only Weight: 700 g 13

Model SWF240P-24/-36/-48 (Continued) Output Power: 240W, Output Voltage: 24V / 36V / 48V Circuit Assembly with Chassis (L option) Circuit Assembly with Chassis and Cover (LC option) 14

Model SWF240P-24/-36/-48 with Terminal Block Output Power: 240W, Output Voltage: 24V / 36V / 48V Circuit Assembly Only with Screw Terminals (T option) 15

Model SWF240P-24/-36/-48 with Terminal Block (continued) Output Power: 240W, Output Voltage: 24V / 36V / 48V Circuit Assembly with Chassis (L option) and Screw Terminals (T option) Circuit Assembly with Chassis and Cover (LC option) and Screw Terminals (T option) 16

Model Number Description [AAA] [NNN] [NN] [-AA] [-A] [-A] Appears only if options selected Option 3, T: Terminal Stand (SWF240P-24/-36/-48 only) Option 2, R: Remote on/off Option 1, L: L-type chassis on product LC: L-type chassis and cover on product Nominal total rated output voltage Nominal total rated output wattage Series identifier, for example, SWF for SWF series Suffixes L: L-type chassis on product Options Selected C: Cover on product R: Remote On/Off T: Terminal Stand Availability None -L O _ -LC O O -R O _ All products -L-R O _ O _ -LC-R O O O _ -L-T O O -LC-T O O _ O -R-T O O SWF240P-24/-36/-48 -L-R-T O _ O O -LC-R-T O O O O O denotes available 17

Input and Output Terminals, Connections and Pin Assignments Input / Output electrical connector manufacturer: JST Mfg. Co., Ltd. Terminal stand manufacturer: Emuden Corporation Model: SWF050P-24 Connector Socket Identifier Pins Manufacturer Part Number Mating Plug Connector Contacts CN101 1: AC(L) 2: AC(N) 3: FG B3P5-VH VHR-5N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN601 1: -V 2:-V 3: +V 4: +V B4P-VH VHR-4N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN602 (R option only) 1: R/C + 2: R/C- B02B-XH-A XHP-2 SXH-001T-P0.6 (strip) BXH-001T-P0.6(reel) Model: SWF100P-24/-36/-48 Connector Socket Identifier Pins Manufacturer Part Number Mating Plug Connector Contacts CN101 1: AC(L) 2: AC(N) 3: FG B3P5-VH VHR-5N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN601 1: -V 2:-V 3: -V 4: -V 5: +V 6: +V 7: +V 8: +V B4P-VH VHR-4N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN602 (R option only) 1: R/C + 2: R/C- B02B-XH-A XHP-2 SXH-001T-P0.6 (strip) BXH-001T-P0.6(reel) 18

Model: SWF150P-24/-36/-48 Connector Socket Identifier Pins Manufacturer Part Number Mating Plug Connector Contacts CN101 1: AC(L) 2: AC(N) 3: FG B3P5-VH VHR-5N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN601 1: +V 2:+V 3: +V 4: +V 5: +V 6: +V B6P-VH VHR-6N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN602 1: -V 2:-V 3: -V 4: -V 5: -V 6: -V B7P-VH VHR-7N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN603 (R option only) 1: R/C + 2: R/C- B02B-XH-A XHP-2 SXH-001T-P0.6 (strip) BXH-001T-P0.6(reel) Model: SWF240P-24/-36/-48 Identifier Connector Socket Pins Manufacturer Part Number Mating Plug Connector Contacts CN101 1: AC(L) 2: AC(N) 3: FG B3P5-VH VHR-5N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN601 1: +V 2:+V 3: +V 4: +V 5: +V 6: +V B6P-VH VHR-6N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN602 1: -V 2:-V 3: -V 4: -V 5: -V 6: -V B7P-VH VHR-7N SVH-21T-P1.1 (strip) BVH-21T-P1.1 (reel) CN603 (R option only) 1: R/C + 2: R/C- B02B-XH-A XHP-2 SXH-001T-P0.6 (strip) BXH-001T-P0.6(reel) TB101 (T option only) TB601 (T option only) 1: AC(L) 2: AC(N) 3: FG 1: +V 2:+V 3: -V 4: -V T7201-A-X (Screw terminals) M4 screw T7202-A-X (Screw terminals) M4 screw 19

Functional Description Dynamic load The peak current load occurs within 10 seconds (duty cycle of 35% or less). The SWF series can also be used with dynamic (pulse) load. Output Current rms Value, Irms = t is peak current time T is current period IOUT(PEAK) is peak output current amplitude Remote on/off control The SWF series supports remote on/off control (R option required). This function requires the use of a DC power supply external to the SWF series power supply. SWF (with remote on/off option) With remote on/off, the SWF product output goes on when a voltage from 4.5 to 5.5 V (recommended current is 5 ma) is applied between the R/C+ and R/C terminals. The output goes off when the voltage drops below 0.8 V or is open. The following should be included in the application design: CN602 (SWF050P and SWF100P) CN603 (SWF150P and SWF240P) Internal power supply Current limiting resistor External power supply If the external power supply voltage is too high, insert a current limiting resistor (R). Use twisted or shielded wire to prevent noise induction. Current limiting resistor, R = VRC 1 (V) 1 (kω) 5 (ma) 5 (ma) 5 (ma) Isolate the remote on/off control circuit from the SWF input, output, and FG circuits. 20

Installation Electrical clearance air space When the products are used without the L-type chassis (L option) or the cover (C option), ensure adequate free air space is left around the circuit assembly for clearance to allow adequate electrical insulation from an metal enclosure or mounting surface. The minimum clearance distances are shown in the diagram. Please contact Sanken for other mounting options. Note: Additional free air space is recommended for cooling of the products while operating. SWF240P -24/-36/-48 21

Mounting Adequate free air space is mandatory to allow convective airflow to cool the unit. If the cooling effect is insufficient, output could stop. Ensure there is free airspace clearance on all sides of the unit. A minimum of 8 mm is required between the circuit assembly and any metallic mounting surface, and spacers should be used between the product and the mounting surface. The unit can be mounted in many orientations, with surrounding free air space. See illustration below. Please consult with Sanken for other orientations. Each orientation results in a different airflow and a different deratingcharacteristic, as shown in the Deratingsection. Mounting flanges are provided at the front and rear of the circuit assembly (an additional hole for a mounting screw is provided on the side of the SWF240P circuit assembly board), and screw holes and slots are provided in the chassis and covers. If the product is used in a dusty environment, an air filter may be required and the filter may affect ventilation efficiency. In such situations, additional derating could be required. 22

Derating Derating is applied to each power unit independently. To prevent the load factor from being truncated due to the derating, make sure the power unit is used within specification, considering both deratingoftotalratedpoweroftheunitandadjacentsourcesof heat or interference with cooling air flow. The derating characteristics of the products at various ambient temperatures are shown below. Each mounting orientation results in a different airflow and a different derating characteristic. The individual traces are labelled according to the recommended mounting orientations shown in the Mounting section. Without Chassis or Cover With Chassis or Cover SWF050P-24 SWF100P-24/-36/-48 SWF150P-24/-36/-48 SWF240P-24/-36/-48 23

Model SWF050P-24 Parameter Specification and Standards Value Rated Input Voltage Allowable Input Voltage 100 to 240VAC 85 to 264VAC Input Current(typ) 1 1.0A (VIN = 100V) Input Condition Rated Frequency Allowable Frequency Range 50 / 60 Hz 47 to 63 Hz Power Factor (typ) 1 0.5 Efficiency (typ) 1 84% (VIN = 100V) / 85% (VIN = 240V) InrushCurrent (typ) 2 15A (VIN = 100V) / 30A (VIN = 200V) Leakage Current (max) 1 0.75 ma (VIN = 240V) Rated Output Voltage 24V Output Voltage Variation 9 21.6 to 26.4V Rated Output Current 2.1A Maximum Peak Current 8 4.2A (within 10 s, duty cycle 35% or less) Output Conditions 3 Allowable Output Current Range 0 to 4.2A Rated Output Power 50W Constant Voltage Accuracy 5 ±3% Additional Functions Ripple Noise 1,4 Output Holding Time (min) 1 Start-up Time (typ) 1 Over current Protection Over voltage Protection6 Over temperature Protection Remote Sensing Operations Display 300mVP-P 20ms 500ms Detection above 101% of maximum peak current (automatic recovery) Detection above 115% of maximum output voltage (output cut-off) Not Provided Not Provided Not Provided Operating Temperature Range 10 C to 70 C Storage Temperature Range 25 C to 85 C Operating Humidity Range 30% to 90% Storage Humidity Range 20% to 90% Cooling Requirements Natural air cooling Environmental Conditions Vibration Resistance Vibration Frequency 10 to 55 Hz Sweep Time 3 minutes Acceleration 19.6 m / s²(2 G) Vibration Detection x, y, z Vibration Time One hour in each of three directions Shock Resistance Installation Conditions 98 m / s²(10 G); conduct this test on an oak board with a flat surface and a thickness of 10 mm or more; lift one edge of the bottom side of the unit 50 mm and drop it on the board; drop 3 times on each of the 4 edges Derating may be required due to mounting orientation Continued on next page 24

Continued from the previous page. Model SWF050P-24 Parameter Value Insulation 7 Insulation Withstand Voltage Insulation Resistance Input-Output Input-FG Output-FG Input-Output Input-FG Output-FG 3000 VAC one minute (leakage current 15 ma or less) 2000 VAC one minute (leakage current 15 ma or less) 500 VAC one minute (leakage current 15 ma or less) 100 MΩ (measured with 500 VDC) UL60950-1, C-UL(CSA60950-1) Safety Standards SEMKO (EN60950-1) certified Applicable Standards Conducted Emissions EMC Designed to meet Electrical Appliance and Safety law Designed to meet FCC Class B Designed to meet EN55022 Designed to meet VCCI Class B Designated to meet harmonic current IEC61000-3-2 1. Specified under rated input/output conditions at an ambient temperature of 25 C. 2. More current above noted values may flow at restart (ambient temperature of 25 C). 3. Output conditions are measured at a point 15 cm from the output connector, with a 63V / 100μF electrolytic capacitor and a 0.1μF film capacitor connected to that point. 4. Ripple noise is measured with a 100 MHz oscilloscope using a 1:1 probe. 5. The constant voltage accuracy is measured with a static input variation, a static load variation, a time drift, and an ambient temperature variation. 6. Reset is performed by reapplying input voltage. 7. Insulation conditions are specified at normal temperature and humidity. 8. Start-up is to be performed at less than the rated output current. The maximum Peak current shall be within 10s, duty cycle 35% or less. 9. In the case where output voltage is variable, set a voltage such that Output Voltage Variation, Rated Output Current, and Rated Output Power are not exceeded. 25

Specification and Standards Model SWF100P-24/-36/-48 Parameter SWF100P-24 SWF100P-36 SWF100P-48V Rated Input Voltage Allowable Input Voltage 100 to 240VAC 85 to 264VAC Input Current(typ) 1 1.4A (VIN = 100V) Input Condition Rated Frequency Allowable Frequency Range 50 / 60 Hz 47 to 63 Hz Power Factor (typ) 1 0.9 Efficiency (typ) 1 86% (VIN = 100V) / 89% (VIN = 240V) InrushCurrent (typ) 2 15A (VIN = 100V) / 30A (VIN = 200V) Leakage Current (max) 1 0.75 ma (VIN = 240V) Rated Output Voltage 24V 36V 48V Output Voltage Variation 9 21.6 to 26.4V 32.4 to 39.6V 43.2 to 52.8V Rated Output Current 4.2A 2.8A 2.1A Maximum Peak Current 8 8.4A 5.6A 4.2A Output Conditions 3 Allowable Output Current Range 0 to 8.4A 0 to 5.6A 0 to 4.2A Rated Output Power 100W Constant Voltage Accuracy 5 ±3% Ripple Noise 1,4 150mVP-P 150mVP-P 250mVP-P Additional Functions Output Holding Time (min) 1 Start-up Time (typ) 1 Over current Protection Over voltage Protection6 Over temperature Protection Remote Sensing Operations Display 20ms 500ms Detection above 101% of maximum peak current (automatic recovery) Detection above 115% of maximum output voltage (output cut-off) Not Provided Not Provided Not Provided Operating Temperature Range 10 C to 70 C Storage Temperature Range 25 C to 85 C Operating Humidity Range 30% to 90% Storage Humidity Range 20% to 90% Cooling Requirements Natural air cooling Environmental Conditions Vibration Resistance Vibration Frequency 10 to 55 Hz Sweep Time 3 minutes Acceleration 19.6 m / s²(2 G) Vibration Detection x, y, z Vibration Time One hour in each of three directions Shock Resistance Installation Conditions 98 m / s²(10 G); conduct this test on an oak board with a flat surface and a thickness of 10 mm or more; lift one edge of the bottom side of the unit 50 mm and drop it on the board; drop 3 times on each of the 4 edges Derating may be required due to mounting orientation Continued on next page 26

Continued from the previous page. Model SWF100P-24/-36/-48 Parameter Value Insulation 7 Insulation Withstand Voltage Insulation Resistance Input-Output Input-FG Output-FG Input-Output Input-FG Output-FG 3000 VAC one minute (leakage current 15 ma or less) 2000 VAC one minute (leakage current 15 ma or less) 500 VAC one minute (leakage current 15 ma or less) 100 MΩ (measured with 500 VDC) UL60950-1, C-UL(CSA60950-1) Safety Standards SEMKO (EN60950-1) certified Applicable Standards Conducted Emissions EMC Designed to meet Electrical Appliance and Safety law Designed to meet FCC Class B Designed to meet EN55022 Designed to meet VCCI Class B Designated to meet harmonic current IEC61000-3-2 1. Specified under rated input/output conditions at an ambient temperature of 25 C. 2. More current above noted values may flow at restart (ambient temperature of 25 C). 3. Output conditions are measured at a point 15 cm from the output connector, with a 63V / 100μF electrolytic capacitor and a 0.1μF film capacitor connected to that point. 4. Ripple noise is measured with a 100 MHz oscilloscope using a 1:1 probe. 5. The constant voltage accuracy is measured with a static input variation, a static load variation, a time drift, and an ambient temperature variation. 6. Reset is performed by reapplying input voltage. 7. Insulation conditions are specified at normal temperature and humidity. 8. Start-up is to be performed at less than the rated output current. The maximum Peak current shall be within 10s, duty cycle 35% or less. 9. In the case where output voltage is variable, set a voltage such that Output Voltage Variation, Rated Output Current, and Rated Output Power are not exceeded. 27

Model SWF150P-24/-36/-48 Specification and Standards Parameter SWF150P-24 SWF150P-36 SWF150P-48V Rated Input Voltage Allowable Input Voltage 100 to 240VAC 85 to 264VAC Input Current(typ) 1 1.9A (VIN = 100V) Input Condition Rated Frequency Allowable Frequency Range 50 / 60 Hz 47 to 63 Hz Power Factor (typ) 1 0.9 Efficiency (typ) 1 87% (VIN = 100V) / 91% (VIN = 240V) InrushCurrent (typ) 2 15A (VIN = 100V) / 30A (VIN = 200V) Leakage Current (max) 1 0.75 ma (VIN = 240V) Rated Output Voltage 24V 36V 48V Output Voltage Variation 9 21.6 to 26.4V 32.4 to 39.6V 43.2 to 52.8V Rated Output Current 6.3A 4.2A 3.2A Maximum Peak Current 8 12.6A 8.4A 6.4A Output Conditions 3 Allowable Output Current Range 0 to 12.6A 0 to 8.4A 0 to 6.4A Rated Output Power 150W Constant Voltage Accuracy 5 ±3% Ripple Noise 1,4 150mVP-P 150mVP-P 250mVP-P Additional Functions Output Holding Time (min) 1 Start-up Time (typ) 1 Over current Protection Over voltage Protection6 Over temperature Protection Remote Sensing Operations Display 20ms 500ms Detection above 101% of maximum peak current (automatic recovery) Detection above 115% of maximum output voltage (output cut-off) Not Provided Not Provided Not Provided Operating Temperature Range 10 C to 70 C Storage Temperature Range 25 C to 85 C Operating Humidity Range 30% to 90% Storage Humidity Range 20% to 90% Cooling Requirements Natural air cooling Environmental Conditions Vibration Resistance Vibration Frequency 10 to 55 Hz Sweep Time 3 minutes Acceleration 19.6 m / s²(2 G) Vibration Detection x, y, z Vibration Time One hour in each of three directions Shock Resistance Installation Conditions 98 m / s²(10 G); conduct this test on an oak board with a flat surface and a thickness of 10 mm or more; lift one edge of the bottom side of the unit 50 mm and drop it on the board; drop 3 times on each of the 4 edges Derating may be required due to mounting orientation Continued on next page 28

Continued from the previous page. Model SWF150P-24/-36/-48 Parameter Value Insulation 7 Insulation Withstand Voltage Insulation Resistance Input-Output Input-FG Output-FG Input-Output Input-FG Output-FG 3000 VAC one minute (leakage current 15 ma or less) 2000 VAC one minute (leakage current 15 ma or less) 500 VAC one minute (leakage current 15 ma or less) 100 MΩ (measured with 500 VDC) UL60950-1, C-UL(CSA60950-1) Safety Standards SEMKO (EN60950-1) certified Applicable Standards Conducted Emissions EMC Designed to meet Electrical Appliance and Safety law Designed to meet FCC Class B Designed to meet EN55022 Designed to meet VCCI Class B Designated to meet harmonic current IEC61000-3-2 1. Specified under rated input/output conditions at an ambient temperature of 25 C. 2. More current above noted values may flow at restart (ambient temperature of 25 C). 3. Output conditions are measured at a point 15 cm from the output connector, with a 63V / 100μF electrolytic capacitor and a 0.1μF film capacitor connected to that point. 4. Ripple noise is measured with a 100 MHz oscilloscope using a 1:1 probe. 5. The constant voltage accuracy is measured with a static input variation, a static load variation, a time drift, and an ambient temperature variation. 6. Reset is performed by reapplying input voltage. 7. Insulation conditions are specified at normal temperature and humidity. 8. Start-up is to be performed at less than the rated output current. The maximum Peak current shall be within 10s, duty cycle 35% or less. 9. In the case where output voltage is variable, set a voltage such that Output Voltage Variation, Rated Output Current, and Rated Output Power are not exceeded. 29

Model SWF240P-24/-36/-48 Specification and Standards Parameter SWF240P-24 SWF240P-36 SWF240P-48V Rated Input Voltage Allowable Input Voltage 100 to 240VAC 85 to 264VAC Input Current(typ) 1 2.9A (VIN = 100V) Input Condition Rated Frequency Allowable Frequency Range 50 / 60 Hz 47 to 63 Hz Power Factor (typ) 1 0.9 Efficiency (typ) 1 88% (VIN = 100V) / 92% (VIN = 240V) InrushCurrent (typ) 2 15A (VIN = 100V) / 30A (VIN = 200V) Leakage Current (max) 1 0.75 ma (VIN = 240V) Rated Output Voltage 24V 36V 48V Output Voltage Variation 9 21.6 to 26.4V 32.4 to 39.6V 43.2 to 52.8V Rated Output Current 10.0A 6.7A 5.0A Maximum Peak Current 8 20.0A 13.4A 10.0A Output Conditions 3 Allowable Output Current Range 0 to 20.0A 0 to 13.4A 0 to 10.0A Rated Output Power 240W Constant Voltage Accuracy 5 ±3% Ripple Noise 1,4 300mVP-P 300mVP-P 400mVP-P Additional Functions Output Holding Time (min) 1 Start-up Time (typ) 1 Over current Protection Over voltage Protection6 Over temperature Protection Remote Sensing Operations Display 20ms 500ms Detection above 101% of maximum peak current (automatic recovery) Detection above 115% of maximum output voltage (output cut-off) Not Provided Not Provided Not Provided Operating Temperature Range 10 C to 70 C Storage Temperature Range 25 C to 85 C Operating Humidity Range 30% to 90% Storage Humidity Range 20% to 90% Cooling Requirements Natural air cooling Environmental Conditions Vibration Resistance Vibration Frequency 10 to 55 Hz Sweep Time 3 minutes Acceleration 19.6 m / s²(2 G) Vibration Detection x, y, z Vibration Time One hour in each of three directions Shock Resistance Installation Conditions 98 m / s²(10 G); conduct this test on an oak board with a flat surface and a thickness of 10 mm or more; lift one edge of the bottom side of the unit 50 mm and drop it on the board; drop 3 times on each of the 4 edges Derating may be required due to mounting orientation Continued on next page 30

Continued from the previous page. Model SWF240P-24/-36/-48 Parameter Value Insulation 7 Insulation Withstand Voltage Insulation Resistance Input-Output Input-FG Output-FG Input-Output Input-FG Output-FG 3000 VAC one minute (leakage current 15 ma or less) 2000 VAC one minute (leakage current 15 ma or less) 500 VAC one minute (leakage current 15 ma or less) 100 MΩ (measured with 500 VDC) UL60950-1, C-UL(CSA60950-1) Safety Standards SEMKO (EN60950-1) certified Applicable Standards Conducted Emissions EMC Designed to meet Electrical Appliance and Safety law Designed to meet FCC Class B Designed to meet EN55022 Designed to meet VCCI Class B Designated to meet harmonic current IEC61000-3-2 1. Specified under rated input/output conditions at an ambient temperature of 25 C. 2. More current above noted values may flow at restart (ambient temperature of 25 C). 3. Output conditions are measured at a point 15 cm from the output connector, with a 63V / 100μF electrolytic capacitor and a 0.1μF film capacitor connected to that point. 4. Ripple noise is measured with a 100 MHz oscilloscope using a 1:1 probe. 5. The constant voltage accuracy is measured with a static input variation, a static load variation, a time drift, and an ambient temperature variation. 6. Reset is performed by reapplying input voltage. 7. Insulation conditions are specified at normal temperature and humidity. 8. Start-up is to be performed at less than the rated output current. The maximum Peak current shall be within 10s, duty cycle 35% or less. 9. In the case where output voltage is variable, set a voltage such that Output Voltage Variation, Rated Output Current, and Rated Output Power are not exceeded. 31

Sanken reserves the right to make, from time to time, such departures from the detail specifications as may be required to permit improvements in the performance, reliability, or manufacturability of its products. Therefore, the user is cautioned to verify that the information in this publication is current before placing any order. When using the products described herein, the applicability and suitability of such products for the intended purpose shall be reviewed at the users' responsibility. Although Sanken undertakes to enhance the quality and reliability of its products, the occurrence of failure and defect of semiconductor products at a certain rate is inevitable. Users of Sanken products are requested to take, at their own risk, preventative measures including safety design of the equipment or systems against any possible injury, death, fires or damages to society due to device failure or malfunction. Sanken products listed in this publication are designed and intended for use as components in general-purpose electronic equipment or apparatus (home appliances, office equipment, telecommunication equipment, measuring equipment, etc.). Their use in any application requiring radiation hardness assurance(e.g., aerospace equipment) is not supported. When considering the use of Sanken products in applications where higher reliability is required(transportation equipment and its control systems or equipment, fire- or burglar-alarm systems, various safety devices, etc.), contact a company sales representative to discuss and obtain written confirmation of your specifications. The use of Sanken products without the written consent of Sanken in applications where extremely high reliability is required(aero- space equipment, nuclear power-control stations, life-support systems, etc.) is strictly prohibited. The information included herein is believed to be accurate and reliable. Application and operation examples described in this publication are given for reference only and Sanken assumes no responsibility for any infringement of industrial property rights, intellectual property rights, or any other rights of Sanken or any third party that may result from its use. The contents in this document must not be transcribed or copied without Sanken s written consent. 32