Diagnostic development to measure parallel wavenumber of lower hybrid waves on Alcator C-Mod

Similar documents
SOL Reflectometer for Alcator C-Mod

First Results From the Alcator C-Mod Lower Hybrid Experiment.

Lower Hybrid. Ron Parker Alcator C-Mod PAC Meeting January January 2006 Alcator C-Mod PAC Meeting 1

Measurements of Mode Converted ICRF Waves with Phase Contrast Imaging in Alcator C-Mod

RF Physics: Status and Plans

Measurement of Mode Converted ICRF Waves with Phase Contrast Imaging and Comparison with Full-wave Simulations on Alcator C-Mod

P. Koert, P. MacGibbon, R. Vieira, D. Terry, R.Leccacorvi, J. Doody, W. Beck. October 2008

Overview of ICRF Experiments on Alcator C-Mod*

Abstract. G.D. Garstka 47 th APS-DPP Denver October 27, Pegasus Toroidal Experiment University of Wisconsin-Madison

Development Status of KSTAR LHCD System

Development of C-Mod FIR Polarimeter*

ICRF Mode Conversion Flow Drive Studies with Improved Wave Measurement by Phase Contrast Imaging

3.10 Lower Hybrid Current Drive (LHCD) System

Microwave Imaging in the Large Helical Device

High Field Side Lower Hybrid Current Drive Launcher Design for DIII-D

Initial Active MHD Spectroscopy Experiments Exciting Stable Alfvén Eigenmodes in Alcator C-Mod

Structural Analysis of High-field-Side RF antennas during a disruption on the Advanced Divertor experiment (ADX)

Design and commissioning of a novel LHCD launcher on Alcator C-Mod

High Density LHRF Experiments in Alcator C-Mod and Implications for Reactor Scale Devices

Advanced Tokamak Program and Lower Hybrid Experiment. Ron Parker MIT Plasma Science and Fusion Center

Novel Vacuum Vessel & Coil System Design for the Advanced Divertor Experiment (ADX)

Investigation of RF-enhanced Plasma Potentials on Alcator C-Mod

System Upgrades to the DIII-D Facility

Density and temperature maxima at specific? and B

Status of the rf Current Drive Systems on MST

Novel Reactor Relevant RF Actuator Schemes for the Lower Hybrid and the Ion Cyclotron Range of Frequencies

Spectral broadening of lower hybrid waves produced by parametric instability in current drive experiments of tokamak plasmas

Launcher Study for KSTAR 5 GHz LHCD System*

Upper limit on turbulent electron temperature fluctuations on Alcator C-Mod APS DPP Meeting Albuquerque 2003

Helicon Wave Current Drive in KSTAR Plasmas

Status Alcator C-Mod Engineering Systems. DoE Quarterly Review October 27, 2005

Study of Elliptical Polarization Requirement of KSTAR 84-GHz ECH System

Magnetron. Physical construction of a magnetron

Construction of 0.5-MW prototype PAM for KSTAR LHCD system

Initial Results from the C-Mod Prototype Polarimeter/Interferometer

Ion Heating Arising from the Damping of Short Wavelength Fluctuations at the Edge of a Helicon Plasma Source

Particle Simulation of Radio Frequency Waves in Fusion Plasmas

Particle Simulation of Lower Hybrid Waves in Tokamak Plasmas

Development of the frequency scanning reflectometry for the registration of Alfvén wave resonances in the TCABR tokamak

DESIGN AND FABRICATION OF CAVITY RESONATORS

ICRF mode conversion in three-ion species heating experiment and in flow drive experiment on the Alcator C- Mod tokamak

R.K.YADAV. 2. Explain with suitable sketch the operation of two-cavity Klystron amplifier. explain the concept of velocity and current modulations.

Conceptual Design of Magnetic Island Divertor in the J-TEXT tokamak

Helicon mode formation and rf power deposition in a helicon source

Investigation of ion toroidal rotation induced by Lower Hybrid waves in Alcator C-Mod * using integrated numerical codes

Investigating High Frequency Magnetic Activity During Local Helicity Injection on the PEGASUS Toroidal Experiment

MICROWAVE MICROWAVE TRAINING BENCH COMPONENT SPECIFICATIONS:

3. (a) Derive an expression for the Hull cut off condition for cylindrical magnetron oscillator. (b) Write short notes on 8 cavity magnetron [8+8]

Electro-Optic Sensors for RF Electric Fields: a Diagnostic Tool for Microwave Circuits and Antennas

Helicons - Our Last Year

High Power Antenna Design for Lower Hybrid Current Drive in MST

Evaluation of a Field Aligned ICRF Antenna in Alcator C-Mod

AN IN-LINE POWER MONITOR FOR HE11 LOW LOSS TRANSMISSION LINES

Advanced Density Profile Reflectometry; the State-of-the-Art and Measurement Prospects for ITER

and GHz. ECE Radiometer. Technical Description and User Manual

QPR No SPONTANEOUS RADIOFREQUENCY EMISSION FROM HOT-ELECTRON PLASMAS XIII. Academic and Research Staff. Prof. A. Bers.

Detection and application of Doppler and motional Stark features in the DNB emission spectrum in the high magnetic field of the Alcator C-Mod tokamak

Microwave Experiments on Prairie View Rotamak

Whistlers, Helicons, Lower Hybrid Waves: the Physics of RF Wave Absorption for Current Drive Without Cyclotron Resonances

Electromagnetic Field Simulation for ICRF Antenna and Comparison with Experimental Results in LHD

Field Aligned ICRF Antenna Design for EAST *

Heterodyne Sweeping Radiometer

Detection of Lower Hybrid Waves on Alcator C-Mod with Phase Contrast Imaging Using Electro-Optic Modulators

Field-Aligned ICRF Antenna Characterization and Performance in Alcator C-Mod*

Improved core transport triggered by off-axis ECRH switch-off on the HL-2A tokamak

ICRF Mode Conversion Physics in Alcator C-Mod: Experimental Measurements and Modeling

6 - Stage Marx Generator

Installation of 84-GHz, 500-kW KSTAR ECH system

Radiofrequency Current Drive Experiments in MST

National Fusion Research Institute. Pohang, Korea, December 14-16,

W-band vector network analyzer based on an audio lock-in amplifier * Abstract

Non-inductive Production of Extremely Overdense Spherical Tokamak Plasma by Electron Bernstein Wave Excited via O-X-B Method in LATE

Study of Ion Cyclotron Emissions due to DD Fusion Product Ions on JT-60U

Reconfigurable 6 GHz RF Vector Signal Transceiver with 1 GHz Bandwidth

PXIe Contents CALIBRATION PROCEDURE. Reconfigurable 6 GHz RF Vector Signal Transceiver with 200 MHz Bandwidth

ECRH Beam Optics Optimization for ITER Upper Port Launcher

Status of C-Mod Diagnostics. Presented by Jim Irby For the C-Mod Group

ICRF Physics in KSTAR Steady State

ELECTROMAGNETIC COMPATIBILITY HANDBOOK 1. Chapter 8: Cable Modeling

EMC Near-field Probes + Wideband Amplifier

Study of Plasma Equilibrium during the AC Current Reversal Phase on the STOR-M Tokamak

HIGH POWER HELICON ANTENNA DESIGN FOR DIII-D. R.C. O NEILL General Atomics San Diego, California, USA

ECRF Heating on CS Reactors

GA A25836 PRE-IONIZATION EXPERIMENTS IN THE DIII-D TOKAMAK USING X-MODE SECOND HARMONIC ELECTRON CYCLOTRON HEATING

Fast Electron Temperature Diagnostic Based on Langmuir Probe Current Harmonic Detection on D-IIID

EC6011-ELECTROMAGNETICINTERFERENCEANDCOMPATIBILITY

GA A22963 RECENT DEVELOPMENTS ON THE HIGH POWER ECH INSTALLATION AT THE DIII D TOKAMAK

Dinesh Micro Waves & Electronics

Recent Results on RFX-mod control experiments in RFP and tokamak configuration

ECRH on the Levitated Dipole Experiment

TOROIDAL ALFVÉN EIGENMODES

Variation of N and its Effect on Fast Wave Electron Heating on LHD

C-Mod/PSFC MFE DoE Quarterly Review August 10, 2015

GA A22577 AN ELM-RESILIENT RF ARC DETECTION SYSTEM FOR DIII D BASED ON ELECTROMAGNETIC AND SOUND EMISSIONS FROM THE ARC

High Temporal Resolution Polarimetry on the MST Reversed Field Pinch

Reflectometry for density and fluctuation measurement on EAST

Development of microwave imaging reflectometry at NIFS

Debugging EMI Using a Digital Oscilloscope. Dave Rishavy Product Manager - Oscilloscopes

Development of local oscillator integrated antenna array for microwave imaging diagnostics

High-Resolution Detection and 3D Magnetic Control of the Helical Boundary of a Wall-Stabilized Tokamak Plasma

Transcription:

Diagnostic development to measure parallel wavenumber of lower hybrid waves on Alcator C-Mod S. G. Baek, T. Shinya*, G. M. Wallace, S. Shiraiwa, R. R. Parker, Y. Takase*, D. Brunner MIT Plasma Science and Fusion Center *University of Tokyo 21 st Topical Conference on Radiofrequency Power in Plasmas April 27 29, 2015 Work supported by US DoE Cooperative agreement DE-FC02-99ER54512 at MIT using the Alcator C-Mod tokamak, a DoE Office of Science user facility, and by Japan/U. S. Cooperation in Fusion Research and Development. 1/24

Motivation: Measurement of parallel wavenumber (k ) of lower hybrid waves Lower Hybrid Current Drive (LHCD) system at 4.6 GHz in Alcator C-Mod operates at ITERrelevant frequency, B-field, densities, and configurations. LH launcher at C-Mod k of LH waves is set by the relative phase of the electric field between the adjacent waveguides (grills), and determines wave propagation and damping mechanisms. Direct k measurements away from the launcher could help study the evolution of k in tokamaks and understand the role of spectral broadening mechanisms such as scattering by turbulence or parametric decay instabilities. We are developing an array of magnetic loop probes, which will allow measuring the k and polarization of LH waves in the scrape-off layer. 2/24

An array of magnetic probes allow measuring the phase and polarization of LH waves. Array of Loop probes Δx B 1 B 2 B 1 = B 0 e iφ 1 B 3 B : Background paralle l magnetic field Magnetic loop probes measures the induced voltage due to time varying magnetic flux, as indicated by Faraday s Law: E = B t An array of probes along the background magnetic field line will provide the relative phase among the measurement locations. B 2 = B 0 e iφ 2 B 3 = B 0 e iφ 3 Δx determines the relative phase Δ φ of the measured signals among the probes. In Alcator C-Mod, the launched n from the LH grill antenna is typically 1.9, which translates into λ /2 = 17.2 mm, implying that the relative distance among the probes need to be ~ 5 mm. 3/24

A magnetic loop antenna has been developed in-house. A probe has been designed in the University of Tokyo [1]. Inner diameter of the circular coil : 1.2 mm A shield minimizes noise pickups. A slit on the surface of the shield allows wave field propagation to the coil. Diameter of the shield : 5 mm Dimension of the slit on the shield: 4 mm x 0.5 mm A vacuum-compatible version is in-house fabricated Inner conductor to the outer stainless steel jacket is silver solder brazed. The solder employed was Easy-flo 35 (35% silver, melting point of 1124 degrees Fahrenheit). Slit Coil Slit Shield 10 cm Shield 1 cm *Modelling by T. Shinya [1] T. Shinya, et. al., Plasma Fusion Res. 9, 3402040 (2014) 4/24

Slotted waveguides are used to examine the probe response. The surface of the WR187 waveguide (a = 47.55 mm x b = 22.15 mm) on the narrower dimension side has been slotted to place the probe and calibrate the probe. Bandwidth of the WR187 waveguide: 3.95 5.85 GHz The cover holds the magnetic probe, and covers the slotted surface of the WR187 waveguide. Using a network analyzer, TE10 mode is excited at one end of the waveguide. By connecting the other end of the network analyzer to the probe, one measures S- parameters of the probe. 5/24

The probe has a reasonable flat frequency response in the frequency range of interest. At the fixed location in the slotted waveguide, the frequency response of the probe was examined with a network analyzer. The probe shows a flat response within 4.5 4.7 GHz. No anomalous resonance behavior between 4 and 5 GHz. It also shows the linear variation in phase as a function of frequency. 6/24

The probe can be also used to measure the polarization of the wave. Define θ to be the angle between the surface normal vector of the coil and the B-field fluctuation vector. The angle determines the area that the probe coil intercepts the B-field. When θ = 0 deg, S21 is -55 db. Measurements show that the probe is sensitive to the polarization by ~25 db, and follows the cos 2 θ dependence. Coil θ B θ=0deg θ=90deg 7/24

Phase response of the probe: by translating the magnetic probe along the waveguide, the wavenumber of the B-field is compared to the theory. By moving the cover along the waveguide with the probe fixed, the probe measures the phase variation. For the TE10 mode in the WR187 waveguide, the Δx propagation constant is β = k 2 π a 70.11 (1/m) at 4.6 GHz, where k is the wavenumber. 2 = The measurement indicates that β = 69.94 (1/m), which is in good agreement with the theory. 8/24

The probe measurement capability is strongly sensitive to the relative distance from the shield end to the waveguide surface. The figure on the left-hand side shows the distance (d) between the probe shield to the inner surface of the WR187 waveguide. Copper plate with a hole Probe Shield d Inner Surface of the WR187 waveguide As d increases, the probe end is outside of the waveguide region, and S21 decreases significantly. This implies that when the probe is placed between the protective tiles, it needs to be placed right behind the protect tile for the maximized response. 9/24

The radially movable probe system (Surface Science Station or S3) will be utilized to mount the array of the magnetic probes. One big advantage of S3 is its radially movable capability [1]. S3 had previously been used to study waves in the ion cyclotron range of frequencies. It is located at the K-port, which is about 3 ports (or 108 degrees toroidally) away from the LH launcher at the C-port. This location could be an ideal location to intercept the LH resonance cone on the first pass from the launcher to the plasma. *Figures from R. Ochoukov s thesis [1] R. Ochoukov, MIT Thesis (2013) 10/24

A new probe head is under fabrication to mount magnetic probes and Langmuir probes. Two rows of three magnetic probes will be mounted on the probe head. Probe Array The top row will be sensitive to wave fields associated with B perpendicular to the background magnetic field. B The bottom row will be sensitive to wave fields with B parallel to the background magnetic field. Langmuir Probe 11/24

Langmuir probes will be also installed to measure plasma density and temperature. On the S3 probe head, Langmuir probes will be also placed to measure the local density and temperature at the measurement location. B n = B B n B = B R + B Z S3 has been designed to use the existing upper divertor probes. The probe tip geometry needs to be considered. The cut in the probe tip is such that the cutted plane is nearly parallel to the field line (~ 10 deg.) B = B R + B + B Z To find a surface normal vector n of the plane of cut, which resides in the same plane that are normal to both B and B, one can give the following two constraints. n B = 0 n B n = n B n cos 10 12/24

Ray tracing [1] simulations indicates that the S3 is expected to detect the LH wave-fields with low n at high densities. S3 S3 S3 Poloidal location of S3 [1] A.P. Smirnov, R.W. Harvey, and K. Kupfer, A general ray tracing code GENRAY, Bull Amer. Phys. Soc. Vol 39, No. 7, p. 1626 Abstract 4R11 (19 94) 13/24

We expect that the measured power with the probe will be around -10 dbm. The power density of the LH resonance cone is 33 W/mm 2, assuming the net power of 1 MW with the grill surface area of 3x10 4 mm 2. Grill consists of 4 rows of 18 waveguide grills with the dimension of 7 mm x 60 mm. Assuming that the probe intercepts the LH resonance cone, the power that passes through the slit of the magnetic probe is 66 W. The area of the slit is 2 mm 2 (= 4 mm x 0.5 mm) Based on the bench test, we expect that the S21 of the probe will be about 60 db, indicating that the measured power will be 0.066 mw, or - 12 dbm. 14/24

An Intermediate Frequency (IF) stage employs two-step frequency downconversion processes to directly digitize LH signals. LO @ 4.9 GHz LO @ 275 MHz RF 4600 MHz IF = 300 MHz IF=300±12.5 MHz IF=25±12.5MHz LPF 40 MHz Digitizer Band Pass Filter at 300 MHz LO @ 4.9 GHz LO @ 275 MHz Signal Out @ 25 MHz Signal In @ 4.6 GHz Each channel consists of two mixing stages to frequency down-convert the signals at 4.6 GHz to 250 MHz. The amplification in the IF stage is 20 db with an amplifier. The output signals will be directly fed to a fast speed digitizer (100 Msample/sec) 15/24

An example of the frequency down-converted signals using the IF chains is shown below. CH1 CH2 0.331 V 16/24

Oscilloscope The IF system can be expanded to multiple chains to measure the relative between the channels. CH1 CH2 With Phase Shifter LO @ 4.9 GHz LO @ 275 MHz Two independent IF stages are fed with a RF source at 4.6 GHz with a phase-shifter at one channel. The output voltage and the relative phase have been monitored. The relative phase between the two channels maintain its accuracy for a wide range of input power (~50 db). 17/24

Six channel IF chains will be used in the experiment. 6 IF channels The first three channels will be used to measure signals with the three probes sensitive to B perpendicular to the background magnetic field. The rest three channels will be used to measure signals with the three probes sensitive to B parallel to the background magnetic field. With this approach, we would not be able to measure whole frequency spectra (4.4-4.7 GHz). 18/24 However, by controlling the frequency output of the tunable oscillator, we can study the pump frequency and wavenumber spectra (4600 ± 12.5 MHz) and sideband spectra (4570 ±12.5 MHz) independently.

Local Oscillator (LO) system to generate 4.9 GHz signals. Function Generator ZX95-5400+ Tunable VCO: 4900 MHz PC Attenuator and Filter Attenuator and Filter 6-way splitter A voltage controlled oscillator will be remotely controlled with a function generator. Using a 6-way splitter, it outputs the LO signals at +4 dbm. This will allow selecting different frequency range of the input signals around at 4.6 GHz. 19/24

Another LO system to generate the fixed signal at 275 MHz. VCO Attenuator Low Pass Filter Attenuator 6-way splitter The frequency of this VCO is fixed to 275 MHz. We used a voltage regulator and a pot to control the bias voltage. Using a 6-way splitter, it outputs the LO signals at +4 dbm. 20/24

A high speed digitizer is capable of taking data with multiple triggering in a single plasma discharge. PXIe 9848 Digitizer 8-channel 14-bit 100 Msample/s PXI Express digitizer Input range: -2 2 V One trigger input 512 MB onboard storage memory Data captured for 10 msec is 16 MB (8CH x 100 MS./s x 2 Byte x 10 msec) Thus, the onboard memory can take up to 0.32 sec continuously. Δt 1 =20 μsec Multiple Triggering Events Δt 2 =30 msec Time 21/24 However, we plan to take the segmented data by triggering the digitizer 10 times within a shot. In each triggering event, we will take data for Δt 1 =20 μsec (= 2048 points at the rate 100 Msample/sec) with the waiting time of Δt 1 =30 msec.

The system has been tested as a whole. Digitizer The electronics has been installed on a 19-inch rack. We making a final assembly (e.g., adding SMA feedthroughs and installing 120V power service line) Below shows an example of the raw signal acquired with the digitizer at 100 MS/sec, after they are frequency downconverted from 4.6 GHz to 25 MHz. (So there are 4 data points in one cycle) 22/24

The system is capable of resolving the phase difference among the channels. Multiple Triggering Events Δt 1 =20 μsec Δt 2 =30 msec Time Signals at 4.6 GHz is fed to the two channels. The digitizer has been triggered multiple times. The FFT spectra shows that both channels have the main peak at 25 MHz. The signal to noise ratio is about 60 db. During the 10 triggering events, the relative phase between the channels shows the stable response. One key issue would be calibrate the system well enough: We plan to use a slotted waveguide to calibrate an array of the probes. 23/24

Summary and Future Work k measurements of LH waves could help us understand the wave propagation and absorption mechanisms. Magnetic loop probes, specific to the C-Mod tokamak environment have been developed. Electronics that down-covert the signals at 4.6 GHz to 25 MHz have been developed, which are capable of resolving the dominant (or single) parallel wavenumber spectrum at the given frequency. Polarizations of the waves will be also examined. Future Work: The probe head is under final fabrication to mount Langmuir probes. We will also bring the rack to the C-Mod cell soon. 24/24