FALL-OF-POTENTIAL GROUND RESISTANCE TESTER

Similar documents
Digital Ground Resistance Tester. Model 4610 & 4610 Kits

GROUND TESTERS For all of your Ground Testing needs...

CLAMP-ON METER. Models 500, 501, 502, 503, 511, 512 & 514. Call toll free (800) or visit

GROUND RESISTANCE TESTERS

MODEL 3620 GROUND RESISTANCE TESTER. User Manual. Shop for AEMC products online at: Press To Measure C1 P2 C2

FLEXIBLE CURRENT PROBES

CABLE TESTER. Models CA7024, CA7026 & CA7028. Call toll free (800) or visit

1210N 1250N MEGOHMMETER. User Manual 15 V 500V kV. MEGOHMMETER Model 1250N 600V CAT II / 1000V CAT I! 30. x 10.

Fluke and

EARTH RESISTANCE TESTER

User Guide. 4 wire Earth Resistance Tester Model GRT Washington Street Melrose, MA Phone Toll Free

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

MIT415 Insulation tester

MEGOHMMETER. User Manual

Instruction Manual for Digital Grounding Resistance Meter. Table of Contents

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

User Manual 4 wire Earth Resistance Tester Model GRT300

Fluke 1623 and GEO Earth Ground Testers. Technical Data. Stakeless testing

MACROTEST G1 & G2. I'm pure technology. Touch me, please.

DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER. User Manual ENGLISH. Shop for AEMC products online at:

6470-B. User Manual DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER ENGLISH

Instruction Manual for Digital Grounding Resistance Meter

1507/1503. Insulation Testers. Technical Data. Features and benefits:

Insulation Testers and Earth Ground Testers

DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTERS

Measure voltage without test leads. Product Highlights

UNDERSTANDING. Ground Resistance Testing. I Voltmeter (E) Grounding. electrode. under test. Ground rod and clamp

CLAMP-ON METER 670. User Manual

ELECTRICAL TESTING EQUIPMENT. CLM100 Cable Length Meter. DMEG3 Digital Insulation Resistance Tester. IRT3 Analog Insulation Resistance Tester

AC/DC Current Probes Model MR411 Model MR521

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Soil Resistivity Ground Resistance 3-Point Measurements 4-Point Measurements Clamp-On Measurements

8PK-ST1520 Digital Earth Resistance Tester

MIT400/2. CAT IV Insulation testers MIT430/2: CAT IV Insulation testers

AMM-1022 Digital Multimeter USER`S MANUAL

DIGITAL GROUND RESISTANCE TESTERS

DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER ENGLISH. User Manual

DIGITAL GROUND RESISTANCE AND SOIL RESISTIVITY TESTER ENGLISH. User Manual

FlexProbe FLEXIBLE AC CURRENT PROBE. User Manual. FlexProbe ON OL 1000V CAT III 300A 3000A OFF

Model DIGITAL MULTIMETER

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

PEN TYPE DIGITAL MULTIMETER OPERATION MANUAL T8211D

79/26 Series III Multimeter

# Digital Multimeter

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

MiniFlex MF HF MF HF FLEXIBLE AC CURRENT SENSOR. User Manual. High Frequency Response for Oscilloscopes

Earth 2/3 MI 2126 Instruction Manual Version 1.0, Code No

AC/DC Current Oscilloscope Probe Model SL261

AX-C Introduction. 2. Safety Information

MS8211 DIGITAL MULTIMETER INSTRUCTION MANUAL

DIGITAL ANALOG MEGOHMMETERS

Testers: / Ohmmeters Insulation Measuring Instruments. n Compact and rugged for service calls and laboratory use. Scope of delivery:

Indeks: WMGBMRU30 Earth Resistance and Resistivity Meter

QUICK TESTER FOR TRANSFORMERS AND CAPACITORS

MI-10kV. Technical specifications Operating instructions. Supplier:

INSULATION TESTER SERIES

Fault Mapper Cable Length Meter & Fault Locator Alphanumeric TDR Model CA7024

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

MIT400 Series CAT IV Insulation Resistance and Continuity Testers

DIGITAL MULTIMETER with Non-Contact Detection

USER'S MANUAL DMR-6700

High-precision portable RESISTANCE METER

GROUND RESISTANCE TEST EQUIPMENT

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

UAT-600 Series. amprobe.com

BENNING. CM7 Electrical Tester. Service Information

OWNER S MANUAL HH0308C. AUTO-RANGING DC/True RMS AC DIGITAL MULTIMETER

MiniFlex MF MF FLEXIBLE AC CURRENT SENSOR. User Manual

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

MIT400/2 CAT IV Insulation testers

METRISO. Analog Insulation, Low Resistance and Voltage Measurement Instrument /9.14

PEAK OUTPUT CURRENT 1. MAP V 4.7V to 5.8V 8A 11A 0.2% ±1% 1% 4.9V to 5.1V PEAK OUTPUT CURRENT 4 LINE REGULATION

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

1587/1577 Insulation Multimeters

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

The future of installation testing is here. The Fluke 1650 Series Multifunction Testers

DUAL OUTPUT AC CURRENT/VOLTAGE TRANSDUCER

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

USER MANUAL. Model MA A AC Mini Clamp-on Meter. Additional User Manual Translations available at

DIGITAL MULTIMETER INSTRUCTION MANUAL

Multifunction AC/DC Voltage Tester

Fluke 1587 FC/1577 Insulation Multimeters

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

Dawson DDM190. Digital Multimeter User s Manual

DVM1190 DIGITAL MULTIMETER

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

DDM350 Pen-Type Digital Multimeter User s Manual

Clamp-On Ground Resistance Tester Model 3705

M-1000D DIGITAL MULTIMETER

TOS5300 SERIES Hipot Tester/Hipot Tester with Insulation Resistance Test

DIGIT & POINTER MULTIMETER

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

Pen-type DIGITAL MULTITESTER

SUBJECT TO CHANGE WITHOUT NOTICE

Transcription:

FALL-OF-POTENTIAL GROUND RESISTANCE TESTER Models 3620, 3640 & 4610 Call toll free (800) 537-0351 or visit www.allspec.com Measures soil resistivity (4-Point) (Model 4610) Measures ground resistance (2- and 3-Point) Fall-of-Potential Method Large analog display (Model 3620) Large LCD digital display (Models 3640 and 4610) Designed to reject high levels of noise and interference Auto-Ranging: automatically selects the optimum range (Models 3640 and 4610) Battery powered Extremely simple to operate: connect press read Indicator error lights Rugged dustproof and rainproof case Color-coded terminals and lead identification

Ground Resistance Tester Model 3620 & 3620 Kit Model 3620 Kit The Analog Ground Resistance Tester Model 3620 performs ground resistance measurements from 0.5 to 1000Ω with speed and accuracy. The Model 3620 features three-terminal operation for Fall-of-Potential earth/ ground resistance and also may be used for 2-Point tests. The large 3.1" logarithmic analog scale is easy-to-read, with a separate marking for 25Ω.Alarge Press-to-Measure button allows for easy measurements. A manual zero adjust is provided for accurate readings. Color-coded binding post terminals are easy-to-use with banana plug and spade lug inputs. The heavy duty ABS case is O-ring sealed against dust and water, and the Press-to-Measure button is also sealed. The Ground Tester Model 3620 is battery powered, for convenient use in remote field applications. Mechanical and safety specifications, such as vibration and drop test, meet or exceed IEC standards, to ensure safe and reliable field use. The Ground Resistance Tester Model 3620 is the ideal instrument for electrical contractors, power utilities, REAs, telephone and CATV technicians, and inspectors who must check ground to determine compliance with NEC, OSHA and other specifications. The Model 3620 kit includes meter, one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual. FEATURES Measures ground resistance (2- and 3-Point) Fall-of-Potential Method Direct reading on large analog display 0.5 to 1000Ω and easy 25Ω readings Large 3.1" (77mm), analog display for accurate readings Built-in battery check Color-coded terminals and lead identification Large Press-to-Measure button Portable and compact Extremely simple to operate: connect press read Designed to reject high levels of noise and interference APPLICATIONS Measuring earth resistance of the type of single rod or small ground grids often found in remote telecommunication switching sites Measuring ground electrode resistance of lightning protection equipment Measuring the earth electrode resistance of equipment in recreational areas Testing electrode resistance of ground rods and grids at new construction sites, when utility supplied power has not been supplied Testing earth electrode resistance of grounded towers at cellular phone remote installations 2 Call toll free (800) 537-0351 or visit www.allspec.com

SPECIFICATIONS MODEL 3620 ELECTRICAL Range 0.5 to 1000Ω Resolution 10mΩ Resistance Measurement Frequency 128Hz square wave Test Current 10mA Accuracy ±5% of Reading + 0.1% of galvanometer scale length Auxiliary Electrode Influence Rz 3000 times the reading up to 50kΩ Ry 50kΩ Withstanding Voltage 250Vrms with spikes of 3000VAC or 1000VDC Power Source Eight 1.5V AA Alkaline batteries Battery Life 1680 15-second tests (approximately) Fuse Protection High breaking capacity 0.1A, 250V, 0.25 x 1.25" MECHANICAL Display Analog Pivot movement Connection Color-coded terminals accept spade lugs with minimum gap of 6mm or standard 4mm banana jacks Scale 3.1" (77mm) white scale with black pointer; one scale per range Operating Temperature 14 to 131 F (-10 to 55 C) Storage Temperature -40 to 158 F (-40 to 70 C), 0 to 90% RH with batteries removed Temperature Influence 5% per 10 C Relative Humidity 20 to 90% maximum Dimensions 8.7 x 5.4 x 5.9" (220 x 136 x 150mm) Weight 2 lbs (1.3kg) Case Heavy-duty, ABS Colors Case safety yellow; Front panel gray Mechanical Shock IEC 68-2-27 Vibration Test IEC 68-2-6 Drop Test IEC 68-2-32 Environmental O-ring sealed against dust and water to IP50 SAFETY Rating EN 61010-1, Cat. III, Pollution Degree 2, 24V Double Insulation Agency Approval Emission: EN 50081-1 Immunity: EN 50082-1 CE Mark Call toll free (800) 537-0351 or visit www.allspec.com 3

Ground Resistance Tester Model 3640 & 3640 Kit Model 3640 Kit The Digital Ground Resistance Tester Model 3640 performs ground resistance measurement. This direct reading tester measures from 10mΩ to 1999Ω and is Auto-Ranging, so it automatically seeks out the optimum measurement range. Easy-to-use simply connect the leads, Press-to-Measure and read. The large LCD (nearly 3 /4" high) is easy-to-read, and also indicates low battery status, overrange and lead reversals. The Model 3640 comes with three color-coded terminals to aid in easy hookup. Three LED indicators on the front panel continuously warn the user of any measurement problems to ensure accurate and reliable tests. The Model 3640 is fuse protected up to 250VAC to protect the instrument against voltage into the test leads. In the event of a system fault, it can withstand 250VAC with spikes of 3000VAC or 1000VDC. The heavy duty ABS case is O-ring sealed against dust and water and the Press-to-Measure button is also sealed. Model 3640 is battery powered, for convenient use in remote field applications. Mechanical and safety specifications, such as vibration and drop test, meet or exceed IEC standards, to ensure safe and reliable field use. Ground Resistance Tester Model 3640 is a rugged, easy-to-use instrument ideal for maintenance crews performing numerous tests. The Model 3640 is designed to reject high levels of interference, therefore it can be used under difficult conditions such as high stray currents that normally affect measurement accuracy. The Ground Resistance Tester Model 3640 kit includes one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual. FEATURES Fall-of-Potential method Measures ground resistance (2- and 3-Point) Auto-Ranging: automatically selects the optimum range Designed to reject high levels of noise and interference Extremely simple to operate: connect press read LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections Battery powered Rugged dustproof and rainproof field case Color-coded terminals May also be used for continuity tests on bonding APPLICATIONS Three-point measurements for measuring resistance to ground of ground rods and grids. Three-point measurements are generally used when the electrode or grid is easily disconnected, if corrosion is suspected, or where ground faults are unlikely to occur. Two-point tests for continuity tests on bonding or on pre-established grounds. This test is commonly performed in urban environments where proper auxiliary electrode placement may be obscured by confined real estate. Measurements are referenced against a good local ground conductor. 4 Call toll free (800) 537-0351 or visit www.allspec.com

SPECIFICATIONS MODEL 3640 ELECTRICAL Range (Auto-Ranging 0 to 2000Ω) 20Ω 200Ω 2000Ω Measurement 0.00 to 19.99Ω 20.0 to 199.9Ω 200 to 1999Ω Resolution 10mΩ 100mΩ 1Ω Open Voltage 42V peak Resistance Measurement Frequency 128Hz square wave Test Current 10mA 1mA 0.1mA Accuracy ±2% of Reading + 1ct ±2% of Reading + 1ct ±3% of Reading + 3cts Auxiliary Electrode Influence Range 20Ω 3kΩ 50kΩ Current Circuit 200Ω 30kΩ 50kΩ Voltage Circuit 2000Ω 50kΩ 50kΩ Interference Rejects high levels of interference voltage (DC, 50/60Hz, harmonics) DC voltage in series with X 20VAC voltage in series with Y 13V peak AC voltage in series with Z 32V peak Response Time Approximately six seconds for a stabilized measurement Withstanding Voltage 50VAC with spikes of 3000VAC or 1000VDC Power Source Eight 1.5V AA batteries; Alkaline recommended; LO BAT indication on LCD Battery Life 1800 15-second measurements (approximate) Fuse Protection High breaking capacity 0.1A, 250V, 0.25 x 1.25" MECHANICAL Display 7-segment LCD, 0.71" (18mm) high (3 1 /2 digit); 2000-counts; LCD also indicates overrange, test lead shorts and lead reversals Connection Color-coded terminals accept spade lugs with min. gap of 6mm or standard 4mm banana jacks LED Indication Three LEDs indicate high input noise, high auxiliary rod resistance, open leads, blown fuse Operating Temperature 14 to 131 F (-10 to 55 C), 0 to 90% RH Storage Temperature -40 to 158 F (-40 to 70 C), 0 to 90% RH with batteries removed Dimensions 8.7 x 5.4 x 5.9" (220 x 136 x 150mm) Weight 2.9 lbs (1.3kg) Case Heavy-duty ABS Colors Case safety yellow; Front panel gray Mechanical Shock IEC 68-2-27 Vibration Test IEC 68-2-66 Drop Test IEC 68-2-32 Dielectric Test 3kV, 50/60Hz, one min. between four interconnected measuring terminals and any external metal ground Environmental O-ring sealed against dust and water to IP50 (Protection Index) Electrostatic IEC 801-2 Electromagnetic IEC 801-3 Electric Shock IEC 801-5 SAFETY Rating EN 61010-1, Cat III., Pollution Degree 2, 42V Double Insulation Agency Approval Emission (EN 50081-1) Immunity (EN 50082-1) CE Mark Accuracies and specifications are given for an ambient temperature of 23 C ± 3 K, RH of 45 to 55%, battery power at 8V, auxiliary resistance at the measurement terminals <200Ω, no stray voltage and a magnetic field from 0 to 40Å/m. Call toll free (800) 537-0351 or visit www.allspec.com 5

Ground Resistance Tester Model 4610 & 4610 Kit Model 4610 Kit Digital Ground Resistance Tester Model 4610 performs ground resistance and soil resistivity tests. Direct reading tester measures from 10mΩ to 1999Ω, and is Auto-Ranging, so it automatically seeks out the optimum measurement range. Easy-to-use simply connect the leads, Press-to-Measure and read. The large LCD (nearly 3 /4" high) is easy-to-read, and also indicates low battery status, overrange, and test lead shorts and lead reversals. Three LED indicators on the front panel continuously warn the user of measurement problems to ensure accurate and reliable tests. The Model 4610 is fuse protected up to 250VAC against Accidental connection to live circuits. In the event of a system fault, it can withstand 250VAC with spikes of 3000VAC or 1000VDC. The heavy duty ABS case is O-ring sealed against dust and water and the Press-to-Measure button is also sealed. Model 4610 is battery powered for convenient use in remote field applications. Mechanical and safety specifications, such as vibration and drop test, meet or exceed IEC standards, to ensure safe and reliable field use. The Ground Resistance Tester Model 4610 is a rugged, easy-to-use instrument ideal for maintenance crews performing numerous tests. The Model 4610 is designed to reject high levels of interference, so it can be used under difficult conditions such as high stray currents that normally affect accuracy. The Ground Resistance Tester Model 4610 kit includes meter, one 16 ft color-coded lead, two 100 ft color-coded leads, two 300 ft leads on reels, four 16" auxiliary ground electrodes, soft carrying case, batteries and user manual. FEATURES Fall-of-Potential method Measures ground resistance (2- and 3-Point) and soil resistivity (4-Point) Step voltage tests and touch potential measurements Auto-Ranging: automatically selects the optimum range Designed to reject high levels of noise and interference Extremely simple to operate: connect press read LED on faceplate informs operator of high input noise, high auxiliary rod resistance and fault connections Battery powered Rugged dustproof and rainproof field case May be used also for continuity tests on bonding Color-coded terminals APPLICATIONS Three-point measurements of resistance to ground of ground rods and grids. Three-point measurements are generally used when the electrode or grid can be easily disconnected, if corrosion is suspected, or in circumstances where ground faults are unlikely to occur. Four-point tests, or soil resistivity measurements. Locating areas of lowest soil resistivity is essential for achieving an economical grounding installation. Touch potential measurements, an alternative to 3-Point tests in evaluating electrical safety. This test is recommended when the ground cannot be disconnected, where ground faults are highly likely to occur, or when the footprint of grounded equipment (the outline of the part of equipment in contact with the earth) is comparable to the size of the ground to be tested. Two-point tests for continuity tests on bonding or on pre-established grounds. This test is commonly performed in urban environments where proper auxiliary electrode placement may be obscured by confined real estate. Measurements are referenced against a good local ground conductor. 6 Call toll free (800) 537-0351 or visit www.allspec.com

SPECIFICATIONS MODEL 4610 ELECTRICAL Ranges (Auto-Ranging 0 to 2000Ω) 20Ω 200Ω 2000Ω Measurement 0.00 to 19.99Ω 20.0 to 199.9Ω 200 to 1999Ω Resolution 10mΩ 100mΩ 1Ω Open Voltage 42V peak 42V peak 42V peak Resistance Measurement Frequency 128Hz square wave 128Hz square wave 128Hz square wave Test Current 10mA 1mA 0.1mA Accuracy ±2% of Reading + 1ct ±2% of Reading + 1ct ±3% of Reading + 3cts Auxiliary Electrode Influence Range 20Ω 3kΩ 50kΩ Current Circuit 200Ω 30kΩ 50kΩ Voltage Circuit 2000Ω 50kΩ 50kΩ Interference Model 4610 rejects high levels of interference voltage (DC, 50 to 60Hz, harmonics): DC voltage in series with X: 20V; AC voltage in series with Y: 13V peak; AC voltage in series with Z: 32V peak Response Time Approximately six seconds for a stabilized measurement Withstanding Voltage 250VAC with spikes of 3000VAC or 1000VDC Power Source Eight 1.5V AA batteries; Alkaline recommended; LO BAT indication on LCD Battery Life 1800 15-second measurements Fuse Protection High breaking capacity 0.1A, 250V, 0.25 x 1.25" MECHANICAL Display 7-segment LCD, 0.71" (18mm) high (3 1 /2 digit); 2000-counts; LCD also indicates overrange, test lead shorts and lead reversals Connection Color-coded terminals accept spade lugs with min. gap of 6mm or standard 4mm banana jacks LED Indication Three LEDs indicate high input noise, high auxiliary rod resistance, open leads, blown fuse Operating Temperature 14 to 131 F (-10 to 55 C), 0 to 90% RH Storage Temperature -40 to 158 F (-40 to 70 C), 0 to 90% RH with batteries removed Dimensions 8.7 x 5.4 x 5.9" (220 x 136 x 150mm) Weight 2.9 lbs (1.3kg) Case Heavy-duty ABS Colors Case: safety yellow; Front panel: gray Mechanical Shock IEC 68-2-27 Vibration Test IEC 68-2-66 Drop Test IEC 68-2-32 Dielectric Test 3kV, 50/60Hz, one min. between four interconnected measuring terminals and any external metal ground Environmental O-ring sealed against dust and water to IP50 (Protection Index) Electrostatic IEC 801-2 Electromagnetic IEC 801-3 Electric Shock IEC 801-5 SAFETY Rating EN 61010-1, Cat. III, Pollution Degree 2, 42V Double Insulation Agency Approval Emission (EN 50081-1); Immunity (EN 50082-1) CE Mark Accuracies and specifications are given for an ambient temperature of 23 C ± 3 K, RH of 45 to 55%, battery power at 8V, auxiliary resistance at the measurement terminals <200Ω, no stray voltage and a magnetic field from 0 to 40Å/m. Call toll free (800) 537-0351 or visit www.allspec.com 7

CONSTRUCTION Input terminals Press-to-Measure button LED measurement fault indicators: X-Z Fault X-Y Hi Resistance X-Y Hi Noise Analog Display Zero adjustment screw Model 3620 Input terminals Press-to-Measure button LED measurement fault indicators: X-Z Fault Xv-Y Hi Resistance Xv-Y Hi Noise Large LCD with low battery indicator Model 3640 Input terminals Press-to-Measure button LED measurement fault indicators: X-Z Fault Xv-Y Hi Resistance Xv-Y Hi Noise Large LCD with low battery indicator Model 4610 8 Call toll free (800) 537-0351 or visit www.allspec.com

ACCESSORIES Ground Test Kit 3-Point (supplemental 4-Point) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes Catalog No. 2130.62 Ground Test Kit for 3-Point testing (supplemental for 4-Point testing) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes Catalog No. 2130.61 Ground Test Kit for 4-Point testing includes carrying bag, two 300 ft color-coded leads on spools, two 100 ft color-coded leads, four 16" auxiliary ground electrodes, one 16 ft lead with Mueller clip and one 100 ft tape measure Catalog No. 2130.63 ORDERING INFORMATION CATALOG NO. Ground Resistance Tester Model 3620 (3-Point Analog)....................................................... Cat. #2114.90 Includes soft carrying case, batteries and user manual Ground Resistance Tester Model 3640 (3-Point Digital)....................................................... Cat. #2114.92 Includes soft carrying case, batteries and user manual Ground Resistance Tester Model 4610 (4-Point Digital)....................................................... Cat. #2114.94 Includes soft carrying case, batteries and user manual Ground Resistance Tester Model 3620 Kit.................................................................. Cat. #2114.91 Includes meter, one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual Ground Resistance Tester Model 3640 Kit.................................................................. Cat. #2114.93 Includes meter, one 16 ft lead, two 150 ft leads on reels with wind-up handles, two 16" auxiliary ground electrodes, soft carrying case, batteries and user manual Ground Resistance Tester Model 4610 Kit.................................................................. Cat. #2114.95 Includes meter, one 16 ft color-coded lead, two 100 ft color-coded leads, two 300 ft leads on reels, four 16" auxiliary ground electrodes, soft carrying case, batteries and user manual Accessories (Optional) Tape Measure (100 ft).................................................................................... Cat. #2130.60 Ground Test Kit for 3-Point testing (supplemental for 4-Point testing) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes.......................................................... Cat. #2130.61 Ground Test Kit 3-Point (supplemental 4-Point) includes carrying bag, two 100 ft color-coded leads, one 16 ft lead and two 16" auxiliary ground electrodes.......................................................... Cat. #2130.62 Ground Test Kit for 4-Point testing includes carrying bag, two 300 ft color-coded leads on spools, two 100 ft color-coded leads, four 16" auxiliary ground electrodes, one 16 ft lead with Mueller clip and one 100 ft tape measure................ Cat. #2130.63 Your authorized AEMC distributor is: All-Spec Industries 5228 US Hwy 421 N Wilmington, NC 28401 (800) 537-0351 (910) 332-0464 (910) 763-5664 Fax sales@allspec.com Call toll free (800) 537-0351 or visit our website at www.allspec.com Chauvin Arnoux, Inc. d.b.a AEMC Instruments 200 Foxborough Blvd. Foxborough, MA 02035 USA (800) 343-1391 (508) 698-2115 Fax (508) 698-2118 sales@aemc.com