Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor

Similar documents
Motor-protective circuit-breaker, 3p, Ir=40-50A, screw connection. Product range PKZM4 motor protective circuit-breakers up to 65 A

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts. Connection to SmartWire-DT yes in conjunction with DIL-SWD SmartWire DT contactor module

Instructions Contact numbers to EN Coil terminal markings to EN Integrated diode-resistor combination Coil rating 2.

Description Basic devices with positive operation contacts. Standards IEC/EN 60947, EN , VDE 0660, UL, CSA

Description Basic devices with positive operation contacts

EN 50178, IEC

DILK50-10(230V50HZ,240V60HZ) Catalog No Eaton Catalog No. XTCC050D10F. Application Contactors for power factor correction. mm 1 x (2.

ATV12H018F1 variable speed drive ATV kW hp V - 1ph

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

LXM32MD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

ATV12HU40M3 variable speed drive ATV12-4kW - 5hp V - 3ph - with heat sink

LXM32MU60N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Frequency inverters DF Vector frequency inverters DV

ATV12HU22M2. Main. Range of product Altivar 12. Component name Quantity per set Set of 1. Built-in fan. Motor power hp Communication port protocol

ATS48D75Y soft starter for asynchronous motor - ATS48-65 A V KW

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

ATV12H037F1 variable speed drive ATV kW hp V - 1ph - with heat sink

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

SX (690 V) System configuration

LXM32AD18M2 motion servo drive - Lexium 32 - single phase supply voltage 115/230V - 0.5/1kW

PowerFlex 400 Submittal

Primary switch mode power supplies Product group picture

LXM32CD18N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

Power supply CP-D 24/4.2 Primary switch mode power supply

SX (400 V) System configuration

LXM32AD72N4 motion servo drive - Lexium 32 - three-phase supply voltage 208/480V kw

System configuration. Ratings 400 V Class three-phase 90 to 800 kw 690 V Class three-phase 90 to 1000 kw SX-D. Frequency inverters.

Intelligent Drive Systems, Worldwide Services SK 700E F 3070 GB

D SERIES LM16. COMPACT DRIVE V/f and SLV CONTROL. LM16 COMPACT DRIVE V/f and SLV CONTROL

AF AF V50/60HZ-DC Contactor. General Information. Ordering. Popular Downloads. Dimensions. Technical AF

UMG 103. UMG 103 Universal measurement device for DIN rails. GridVis Analysis software. Harmonics. Measurement accuracy 0.5.

D SERIES EM16 IP 20 / NEMA 1 & IP 66 / NEMA 4X COMPACT VECTOR CONTROL DRIVE EM 16 COMPACT VECTOR CONTROL DRIVE

Power supply CP-E 24/2.5

ATV212HU22M3X variable speed drive ATV kW - 3hp - 240V - 3ph - wo EMC - IP21

UMG 103-CBM. Universal measurement device for DIN rails

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

SX (400V) System configuration

CP-E range Benefits and advantages

Power supply CP-T 48/20.0 Primary switch mode power supply

Power supply CP-E 24/0.75

Power supply CP-E 24/20.0

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

CP-T range Product group picture

Power supply CP-T 24/20.0 Primary switch mode power supply

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Subject to changes 11/2003 Page 1/7

Type CP-S, CP-C & CP-A Switch mode

Zelio Control Measurement Relays

Manual 10/12 MN Z-EN. PowerXL. DC1 Frequency Inverter

General Purpose Drives

S11 Adjustable Speed Drive Engineering Specification

Power supply CP-E 24/2.5

For additional PowerFlex 4 and 40 data and general drive information, refer to the following publications:

Introduction (continued) Altivar 12 variable speed drives

This Chapter contains:

Three-phase monitoring relays CM-PFE and CM-PFE.2

Lexium integrated drives

Why choose Danfoss? VLT Technical data Dimensions Ordering

Power quality Harmonics up to 40th harmonic Unbalance, rotary field indication Distortion factor THD-U / THD-I

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

System overview. *Safety PLC according to IEC 61508:1998 and EN ISO 13849:2006. Logic Motion Controller C-based

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

ATS01N125FT soft starter for asynchronous motor - ATS01-25 A V KW

Protection components

ATS01N112FT soft starter for asynchronous motor - ATS01-12 A V KW

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

ACH550 HVAC Drive Submittal

SV2Dx Servo Drives SV200 Servo Drives for DC-Powered Applications

The new Yaskawa Varispeed G7 Inverter

Side view View from below Rear view

ATS01N103FT soft starter for asynchronous motor - ATS01-3 A V KW

Lenze. Global Drive. Frequency inverters 8200/9300 vector kw

TDE MACNO Spa. AC&DC Drives, Servos and Drive System. AFE converters for Renewable Energies Regenerative (active) power supply (Active Front End)

Power supply CP-T 48/5.0 Primary switch mode power supply

8V General information. 2 Order data 8V

Electronic timer CT-TGD.22

Power supply CP-T 24/10.0 Primary switch mode power supply

CP-T range Benefits and advantages

Power supply CP-T 24/40.0 Primary switch mode power supply

Power quality Harmonics up to 40th harmonic Rotary field components Distortion factor THD-U / THD-I

Power supply CP-D 24/1.3

Electronic timer CT-SDD.22

TeSys contactors. TeSys D contactors. IEC/EN , IEC/EN , UL 508, CSA C22.2 n 14. Protection against direct fi nger contact IP 2X

02/11/2015

ATSU01N232LT soft starter for asynchronous motor - ATSU01-32 A V KW

Dynamic drives for low power AC motors

Three-phase monitoring relay

ATSU01N222LT soft starter for asynchronous motor - ATSU01-22 A V KW

ATS01N206QN soft starter for asynchronous motor - ATS01-6 A V KW

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

"Modular" versions designed for application-specific functions LCD with 4 lines of 18 characters and configurable backlighting

Three-phase monitoring relay CM-PVE

Dimension diagrams All dimensions in mm. Typical connection UMG 604-PRO. Power Analyser UMG 604-PRO. Front view. Side view. Versorgungsspannung

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Output Voltage* (nom.)(adjustable)

Transcription:

DATASHEET - DC1-12011FB-A20CE1 Technical data General Variable frequency drives; 1-/3-phase 230 V; 10.5 A; 2.2 kw; EMC filters; braking transistor Part no. DC1-12011FB-A20CE1 Catalog No. 185815 Eaton Catalog No. DC1-12011FB-A20CE1 EL-Nummer 4137010 (Norway) Standards Specification for general requirements: IEC/EN 61800-2 EMC requirements: IEC/EN 61800-3 Safety requirements: IEC/EN 61800-5-1 Certifications CE, UL, cul, RCM, Ukr SEPRO, EAC Production quality RoHS, ISO 9001 Climatic proofing ρ w % < 95%, average relative humidity (RH), non-condensing, non-corrosive Ambient temperature operation (150 % overload) ϑ C -10 - +50 Storage ϑ C -40 - +60 Radio interference level Radio interference class (EMC) C1 (for conducted emissions only), C2, C3, depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary. Environment (EMC) 1st and 2nd environments as per EN 61800-3 maximum motor cable length I m C1 1 m C2 5 m C3 25 m Mounting position Vertical Altitude m 0-1000 m above sea level Above 1000 m: 1% derating for every 100 m max. 4000 m Degree of Protection IP20/NEMA 0 Protection against direct contact BGV A3 (VBG4, finger- and back-of-hand proof) Main circuit Supply Rated operational voltage U e 230 V AC, 1-phase 240 V AC, single-phase Mains voltage (50/60Hz) U LN V 200 (-10%) - 240 (+10%) Input current (150% overload) I LN A 19.2 System configuration AC supply systems with earthed center point Supply frequency f LN Hz 50/60 Frequency range f LN Hz 48-62 Mains switch-on frequency Maximum of one time every 30 seconds Power section Function Frequency inverter with internal DC link and IGBT inverter Overload current (150% overload) I L A 15.75 max. starting current (High Overload) I H % 175 Note about max. starting current for 3.75 seconds every 600 seconds Output voltage with V e U 2 230 V AC, 3-phase 240 V AC, 3-phase Output Frequency f 2 Hz 0-50/60 (max. 500) Switching frequency f PWM khz 16 adjustable 4-32 (audible) Operation Mode U/f control Speed control with slip compensation sensorless vector control (SLV) Frequency resolution (setpoint value) Δf Hz 0.1 Rated operational current At 150% overload I e A 10.5 05/10/2018 Eaton 185815 ED2018 V44.0 EN 1 / 6

Note Rated operational current at an operating frequency of 16 khz and an ambient air temperature of +50 C Power loss Heat dissipation at rated operational current I e =150 % P V W 103.4 Efficiency η % 95.3 Maximum leakage current to ground (PE) without motor I PE ma 4.8 Fitted with Radio interference suppression filter Brake chopper 7-digital display assembly Frame size FS2 Motor feeder Note for normal internally and externally ventilated 4 pole, three-phase asynchronous motors with 1500 rpm -1 at 50 Hz or 1800 min -1 at 60 Hz Note Overload cycle for 60 s every 600 s Note at 230 V, 50 Hz 150 % Overload P kw 2.2 Note at 220-240 V, 60 Hz 150 % Overload P HP 3 maximum permissible cable length I m screened: 100 screened, with motor choke: 200 unscreened: 150 unscreened, with motor choke: 300 Apparent power Apparent power at rated operation 230 V S kva 4.18 Apparent power at rated operation 240 V S kva 4.36 Braking function Standard braking torque max. 30 % MN DC braking torque max. 100% of rated operational current I e, variable Braking torque with external braking resistance Max. 100% of rated operational current Ie with external braking resistor minimum external braking resistance R min Ω 50 Switch-on threshold for the braking transistor U DC V 390 V DC Control section Reference voltage U s V 10 V DC (max. 10 ma) Analog inputs 2, parameterizable, 0-10 V DC, 0/4-20 ma Analog outputs 1, parameterizable, 0-10 V Digital inputs 4, parameterizable, max. 30 V DC Digital outputs 1, parameterizable, 24 V DC Relay outputs 1, parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1) Interface/field bus (built-in) OP-Bus (RS485)/Modbus RTU, CANopen Assigned switching and protective elements Power Wiring IEC (Type B, gg), 150 % FAZ-B25/1N UL (Class CC or J) A 25 150 % overload (CT/I H, at 50 C) DX-LN1-024 Motor feeder 150 % overload (CT/I H, at 50 C) DX-LM3-016 150 % overload (CT/I H, at 50 C) DX-SIN3-016 10 % duty factor (DF) DX-BR050-0K4 20 % duty factor (DF) DX-BR050-0K8 40 % duty factor (DF) DX-BR047-3K1 Design verification as per IEC/EN 61439 Technical data for design verification Rated operational current for specified heat dissipation I n A 10.5 Heat dissipation per pole, current-dependent P vid W 0 Equipment heat dissipation, current-dependent P vid W 103.4 Static heat dissipation, non-current-dependent P vs W 0 05/10/2018 Eaton 185815 ED2018 V44.0 EN 2 / 6

Heat dissipation capacity P diss W 0 Operating ambient temperature min. C -10 Operating ambient temperature max. C 50 IEC/EN 61439 design verification 10.2 Strength of materials and parts 10.2.2 Corrosion resistance Meets the product standard's requirements. 10.2.3.1 Verification of thermal stability of enclosures Meets the product standard's requirements. 10.2.3.2 Verification of resistance of insulating materials to normal heat Meets the product standard's requirements. 10.2.3.3 Verification of resistance of insulating materials to abnormal heat and fire due to internal electric effects Meets the product standard's requirements. 10.2.4 Resistance to ultra-violet (UV) radiation Meets the product standard's requirements. 10.2.5 Lifting Does not apply, since the entire switchgear needs to be evaluated. 10.2.6 Mechanical impact Does not apply, since the entire switchgear needs to be evaluated. 10.2.7 Inscriptions Meets the product standard's requirements. 10.3 Degree of protection of ASSEMBLIES Does not apply, since the entire switchgear needs to be evaluated. 10.4 Clearances and creepage distances Meets the product standard's requirements. 10.5 Protection against electric shock Does not apply, since the entire switchgear needs to be evaluated. 10.6 Incorporation of switching devices and components Does not apply, since the entire switchgear needs to be evaluated. 10.7 Internal electrical circuits and connections Is the panel builder's responsibility. 10.8 Connections for external conductors Is the panel builder's responsibility. 10.9 Insulation properties 10.9.2 Power-frequency electric strength Is the panel builder's responsibility. 10.9.3 Impulse withstand voltage Is the panel builder's responsibility. 10.9.4 Testing of enclosures made of insulating material Is the panel builder's responsibility. 10.10 Temperature rise The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices. 10.11 Short-circuit rating Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.12 Electromagnetic compatibility Is the panel builder's responsibility. The specifications for the switchgear must be observed. 10.13 Mechanical function The device meets the requirements, provided the information in the instruction leaflet (IL) is observed. Technical data ETIM 6.0 Low-voltage industrial components (EG000017) / Frequency converter =< 1 kv (EC001857) Electric engineering, automation, process control engineering / Electrical drive / Static frequency converter / Static frequency converter = < 1 kv (ecl@ss8.1-27-02-31-01 [AKE177011]) Mains voltage V 200-240 Mains frequency 50/60 Hz Number of phases input 1 Number of phases output 3 Max. output frequency Hz 500 Max. output voltage V 250 Rated output current I2N A 11 Max. output at quadratic load at rated output voltage kw 2.2 Max. output at linear load at rated output voltage kw 2.2 With control unit Yes Application in industrial area permitted Yes Application in domestic- and commercial area permitted Yes Supporting protocol for TCP/IP No Supporting protocol for PROFIBUS No Supporting protocol for CAN Yes Supporting protocol for INTERBUS No Supporting protocol for ASI No Supporting protocol for KNX No Supporting protocol for MODBUS Yes Supporting protocol for Data-Highway No Supporting protocol for DeviceNet No 05/10/2018 Eaton 185815 ED2018 V44.0 EN 3 / 6

Supporting protocol for SUCONET No Supporting protocol for LON No Supporting protocol for PROFINET IO No Supporting protocol for PROFINET CBA No Supporting protocol for SERCOS No Supporting protocol for Foundation Fieldbus No Supporting protocol for EtherNet/IP Yes Supporting protocol for AS-Interface Safety at Work No Supporting protocol for DeviceNet Safety No Supporting protocol for INTERBUS-Safety No Supporting protocol for PROFIsafe No Supporting protocol for SafetyBUS p No Supporting protocol for other bus systems Yes Number of HW-interfaces industrial Ethernet 0 Number of HW-interfaces PROFINET 0 Number of HW-interfaces RS-232 0 Number of HW-interfaces RS-422 0 Number of HW-interfaces RS-485 1 Number of HW-interfaces serial TTY 0 Number of HW-interfaces USB 0 Number of HW-interfaces parallel 0 Number of HW-interfaces other 0 With optical interface No With PC connection Yes Integrated breaking resistance Yes 4-quadrant operation possible No Type of converter U converter Degree of protection (IP) IP20 Height mm 231 Width mm 107 Depth mm 152 Relative symmetric net frequency tolerance % 10 Relative symmetric net current tolerance % 10 Approvals Product Standards UL 508C; CSA-C22.2 No. 14; IEC/EN61800-3; IEC/EN61800-5; CE marking UL File No. E172143 UL Category Control No. NMMS, NMMS7 CSA File No. UL report applies to both US and Canada North America Certification UL listed, certified by UL for use in Canada Specially designed for North America No Suitable for Branch circuits Max. Voltage Rating 1~ 240 V AC IEC: TN-S UL/CSA: "Y" (Solidly Grounded Wey) Degree of Protection IEC: IP20 05/10/2018 Eaton 185815 ED2018 V44.0 EN 4 / 6

Dimensions 05/10/2018 Eaton 185815 ED2018 V44.0 EN 5 / 6

05/10/2018 Eaton Industries GmbH http://www.eaton.eu 05/2018 by Eaton Industries GmbH Eaton 185815 ED2018 V44.0 EN 6 / 6