KINAX WT 707 Transmitter for angular position

Similar documents
KINAX WT 717 Programmable Transmitter for Angular Position

KINAX SR 719 Programmable Transmitter for Position Feedback

KINAX 3W2 Transmitter for angular position

KINAX 2W2 Programmable Transmitter for Angular Position

SINEAX I 503 / SINEAX U 504 Transducer for AC current or AC voltage

SINEAX TI 807 Passive DC signal isolator

Rudder or propeller angular position transmitter KINAX WT720

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

SINEAX / EURAX 2I1 Passive DC signal isolator

SINEAX TV 808, 1 channel Isolating Amplifier unipolar/bipolar

SINEAX V 624 Programmable Temperature Transmitter for RTD and TC inputs

Angle position transmitter Type RT-2 Marine bridge instrumentation C (UK) Measuring output: DC current signal 0..20mA or 4..

Plug-in module SIRAX TI 807 Passive DC signal isolator

Plug-in module SIRAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

SINEAX B 811 Power Pack with additional Functions

SINEAX G 537 Transducer for Phase Angle Difference

SINEAX TV809, 1 channel Programmable Isolating Amplifier

SINEAX U 553 Transducer for AC Voltage

SINEAX TV 808, 1 channel Isolating Amplifier, output Ex or non-ex

Angular Position Engineering

Plug-in module SIRAX V 606, 1 or 2 channels Programmable Temp. Transmitter for RTD and TC inputs

SINEAX TV 808, 2 channels Isolating Amplifier Unipolar/Bipolar

SINEAX G 536 Phase Angle or Power Factor Transducer

Connection. Input EEx ia IIC. Sense. Fine tuning adjustment. Fine tuning amplifying. Amplifying. Adjustment. Output. Composition

T40FH. Torque flange. Special features. Data sheet

EURAX UI 505, Combined Transducer for AC current and AC voltage

SALES SERVICE +358 (0)

RISH Ducer E13 3 channel transducer for AC current and voltage

RISH Ducer E15 TRANSDUCER FOR AC CURRENT OR AC VOLTAGE WITH DIFFERENT CHARACTERISTICS

Process Protection Acoustic sensors for pump monitoring

T40FM. Data Sheet. Torque flange. Special features. Overall concept. B en

Temperature transmitter itemp RTD DIN rail TMT 127

for DC currents or voltages, temperature sensors, remote sensors or potentiometers II (1) G Application Features / Benefits

Temperature Transmitters TMT 136, TMT 137

T40B. Torque Flange. Special features. Data sheet. Overall concept

Analogue Temperature Transmitter Model T24.10, PC configurable, Head Mounting

Isolators A3/1. Vibration Transducer Supply Unit Series

SINEAX I 552 Transducer for AC current

TGE5, TGE5-Ex. Transmitter for angular position. Operating instructions 42/14-33 EN Rev. 04

XXXX e. X d.. X X X a

Valve Series V2001 Globe Valve Type 3321 with Pneumatic or Electric Actuator

XXXX e. X d.. X X X a

Incremental encoders Redundant sensing, isolated blind hollow shaft ø mm, cone shaft ø17 mm pulses per revolution

n Measuring range ,02 N m to N m n Clockwise and counter-clockwise torque n Low linearity deviation of ± 0.05 % F.S.

Isolating Repeater Input Series 9163

DS 400 DS 400. Intelligent Electronic Pressure Switch Completely in Stainless Steel. piezoresistive stainless steel sensor

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

EMBSIN 281 G Power factor transducer

ED701 General Industry Pressure Transmitter

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

LENORD. +BAUER... automates motion. GEL 295x Customer-specific precision encoder. Technical Information Version General information.

SINEAX V 604 Programmable universal transmitter

3 Ex i Isolators. Switching Repeater with Power Relay (250 V / 4 A) Type 9170/ Type 9170/

LENORD. +BAUER... automates motion. GEL 2351 with current or voltage interface. Technical information Version General. Features.

Transmitter for temperature and direct current variables in four-wire circuit. Contrans T TEU 315, TEU 315-Ex, TEU 325, TEU 325-Ex 11-3.

Digital Temperature Transmitters Model T12.10, Universally Programmable, Head Mounting Model T12.30, Universally Programmable, Rail Mounting

Temperature head transmitter itemp TC TMT 188

RISH Ducer E13 Transducer For Ac Current Or Ac Voltage With Different Characteristics

T10F. Data Sheet. Torque Flange. Special features. Installation example T10F. B en

Intrinsically safe pressure transmitter For applications in hazardous areas Models IS-20-S, IS-21-S, IS-20-F, IS-21-F

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. accuracy according to IEC 60770: 0.35 % FSO. Nominal pressure

Level Limit Switch nivotester FTL 370, FTL 372

T10FS. Data Sheet. Torque Flange. Special features. Installation example T10FS. B en

Temperature Transmitter itemp RTD DIN rail TMT 127

Isolators A3/1.

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

â Ó itemp TC TMT128 Technical information DIN rail mounted Temperature Transmitter for Thermocouples (TC)

Inductive sensor slot-type SI2-K08-AP7

TQ 402 & TQ 412 / EA 402 / Proximity System : TQ 402 & TQ 412 Proximity Transducers EA 402 Extension Cable IQS 452 Signal Conditioner FEATURES

Remote Switching Unit nivotester FTL 320

Indicomp 2, Indicomp 2-Ex. Indicator and alarm signalling unit 10/ EN

Online data sheet AFS60E-S1AA AFS/AFM60 SSI ABSOLUTE ENCODERS

TQ 401 / EA 401 / IQS 451. Proximity System : TQ 401 Proximity Transducer EA 401 Extension Cable IQS 451 Signal Conditioner FEATURES

TR 104, TR 104-Ex Rail mounted Temperature Transmitters

JUMO dtrans T01 HART / T01T HART / T01 Junior / T01 Ex / T01 HART Ex Programmable 2-wire transmitter

Positioner with HART Communication Type 3780

Online data sheet. ACM60B-S1KE13x06 ACM60 ABSOLUTE ENCODERS

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

Incremental encoders Blind hollow shaft or cone shaft pulses per revolution

Online data sheet ACM36-L1K0-K01 ACS/ACM36 ABSOLUTE ENCODERS

LINAX 4000L Continuous-line recorder

Resistance thermometer Model TR30, compact design

Theta 60R. Technical Data Sheet. Special Features. Fig. 2 Theta R, 2 channel version, in housing S17 hole mounting brackets pulled out.

Screw-in resistance thermometers with plug connector

T22. Torque transducer. Special features. Data sheet

Ult r a s o n i c le v e l me t e r s ULM 55

Resistance thermometer Model TR30, compact design

â itemp Pt100 TMT127 Technical information Pt100 transmitter for DIN rail mounting for high accuracy temperature monitoring

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Online data sheet AFS60E-S4AC AFS/AFM60 SSI ABSOLUTE ENCODERS

Rotary Measurement Technology Incremental Encoders

Online data sheet AFS60A-BJPA AFS/AFM60 SSI ABSOLUTE ENCODERS

RISH Ducer TV 808, 2 channels Isolating amplifier unipolar / bipolar

Temperature transmitter itemp PCP DIN rail TMT 121

0 2 1 â Ó. itemp HART TMT182. Technical Information

MiniCoder GEL 2444T Sensor with square-wave signals and internal interpolation

0 2 1 â Ó. itemp HART TMT182. Technical Information

ABSOLUTE ROTARY ENCODER SSI

Transcription:

Ruggedized version pplication The KINX WT 707 (Figs. 1 to 6) converts the angular position of a shaft into a load-independent direct current signal, proportional to the angular position. The unit is contact free. The robust housing has made this unit ideal for machines and ship building. 0102 II 2 G Features / Benefits Fig. 1. KINX WT 707 with plug-in connector. Fig. 2. KINX WT 707 with plug-in connector and foot. Measuring input: ngular position Measured variable Measuring range limits ngular position 0...5 to 0...270 Measuring output: DC current signal (load-independent, 2-, 3- or 4- wire connection) Potentiometer for adjusting span / Optimum matching of desired measuring range Direction of rotation: output signal increases for clockwise or counterclockwise rotation Capacitive scanning system / No wear and low annual maintenance Fig. 3. KINX WT 707 with screw terminals, cable glands and foot. Fig. 4. KINX WT 707 with additional gear, plug-in connector and foot. Continuous shaft rotation / No damage when overshooting angle measuring range vailable with type of protection Intrinsic safety EEx ia IIC T6 / Can be mounted in hazardous areas (see Table 4: Data on explosion protection ) ncillary unit in ruggedized housing / Vibration and shock-resistant, for applications on large machines and in ship building Marine version also available as per Lloyd s Register of Shipping Fig. 5. KINX WT 707 with additional gear, plug-in connector and mounting flange. Fig. 6. KINX WT 707 with additional gear, screw terminals, cable glands and foot. Camille Bauer WT 707 Le 08.981

Technical data Measuring input Measured quantity: ngle of rotation α Measuring principle: Capacitive method Differential capacitor with contactfree, non-wearing positional pick-up. Drive shaft fully rotatable without mechanical stops Measuring ranges: 0 5 to 0 270 (without gear) Preferred ranges 0 10, 0 30, 0 60, 0 90, 0 180 or 0 270 0 10 to 0 1600 turns (with additional gear) Frictional torque: Sense of rotation: Measuring output Output variable I : pprox. 25 Ncm Zero point correction: pprox. ± 5% Clockwise or counterclockwise (seen from the shaft side). The same transmitter can be used for both directions of rotation. switch has to be changed, however, to reverse the direction on transmitters with ranges 0 > 150 to 0 270, see Settings. See Feature 13 and 14 in Table 3: Specification and ordering information for direction of rotation on transmitters with additional gear. Load-independent DC current, proportional to the input angle Span adjustment: pprox. 5 / 30%, see Feature 9 Current limitation: Standard ranges: Non-standard ranges: I max. 40 m 0 1 m, 3- or 4-wire connection 0 5 m, 3- or 4-wire connection 0 10 m, 3- or 4-wire connection 4 20 m, 2-wire connection or 0 20 m, 3- or 4-wire connection adjustable with potentiometer 4 20 m, 3- or 4-wire connection 0 20 m, 4-wire connection 0 > 1.00 to 0 < 20 m 3- or 4-wire connection 12 V External resistance (load): max. [kω] = I [m] (for instruments with DC/C power supply by C/DC power pack, with electric isolation) [V] 12 V max. [kω] = I [m] (for instruments with DC power supply, without electric isolation) I = Output signal end value Residual ripple in output current: < 0.3% p.p. Response time: < 5 ms ccuracy Reference value: Basic accuracy: Measuring range Limit of error 0.5% for ranges 0 150 Limit of error 1.5% for ranges from 0 > 150 to 0 270 Reproducibility: < 0.2% Reference conditions: mbient temperature 23 C ± 2 K Power supply = 18 V External resistance = 0 Ω Influence effects (maxima): (included in basic error) Linearity error ± 0.4% for ranges 0 150 ± 1.4% for ranges from 0 > 150 to 0 270 Dependence on external resistance max. ± 0.1% Power supply influence ± 0.1% dditional errors (maxima): Temperature influence (25 70 C) ± 0.2% / 10 K Bearing play influence ± 0.1% Power supply DC and C voltage: Table 1: Nominal voltages U N 24 60 V DC / C 85 230 V DC / C Nominal voltages and tolerances see Table 1 Tolerances DC 15 33% C ± 15% (only possible with standard version, non-ex, with electric isolation, with C/DC power pack (DC and 45 400 z) Camille Bauer 2

Power consumption: Power supply effect on accuracy: < 0.9 W resp. < 1.8 V 0.1% within the admissible power supply tolerance Connector Socket Plug DC voltage only 1 : 12 33 V (possible with standard version, non- Ex, without electric isolation) 12 30 V (necessary with Ex version, type of protection Intrinsic safety EEx ia IIC T6, without electric isolation) Main part Fig. 7. Cable routed to rear. Rear (cover) Max. residual ripple: Max. current consumption: 10% p.p. pprox. 5 m I Socket Plug Power supply effect on accuracy: < 0.2% within the admissible power supply tolerance Connector Mechanical withstand Permissible vibration: (without additional gear) Shock: Permissible static load on the shaft: Mounting position: ousing data Material of housing: (main part) Material of back: Material of plug-in connector: Material of cable glands: 0 200 z, 10 g continuous, 15 g for 2 h 200 500 z, 5 g continuous, 10 g for 2 h 3 50 g every 10 impulses in all 3 axes Max. 1000 N (radial) Max. 500 N (axial) If subjected to vibration the shaft load should be as low as possible to ensure optimum life of the bearing ny Steel Finish QPQ (nitro-carbonated) Plastic (polyester), when plug-in cable specified or metal (aluminium), when cable access via screw terminals and cable glands Plastic Metal The plug-in connector consists of a socket mounted on the transmitter and plug on the end of the connecting cable (screw gland) with 7 screw terminals (wire gauges up to 1 mm 2 ). The socket can be mounted so that the cable is routed to either the rear (see Fig. 7) or the front (see Fig. 8). Main part Fig. 8. Cable routed to front. Rear (cover) On units with screw terminals and cable glands PG 11 (see Fig. 9) there are 4 screw terminals and a grounding terminal in the rear cover. The screw terminals accept gauges up to 1.5 mm 2 and are accessible after removing the cover. GOSSEN METRWTT CMILLE BUER Rear (cover) Screw terminals Cover Ground terminal Cable glands Fig. 9. KINX WT 707 with screw terminals and cable glands. Mounting: Directly (instrument without foot, without flange) Mounting with foot Mounting with flange Weight: See Table 2 Table 2: Weight Description of parts pprox. KINX WT 707 without additional gear 2.9 kg (also without foot or without flange) pprox. KINX WT 707 with additional gear 3.9 kg (also without foot or without flange) 0.5 kg Foot (on its own) 0.5 kg Flange (on its own) 1 Polarity reversal protection. The voltage must not fall below 12 V. Camille Bauer 3

Regulations Electromagnetic compatibility: The standards DIN EN 50 081-2 and DIN EN 50 082-2 are observed Intrinsic safety: cc. to EN 50 020: 1994 Test voltage: 2.2 kvrms, 50 z, 1 min. between power supply and housing power supply and measuring output (with DC/C power supply, with electric isolation) 500 Vrms, 50 z, 1 min. all electrical connections to housing (with DC power supply, without electric isolation) ousing protection: IP 66 acc. to EN 60 529 Impulse voltage withstand: 1 kv, 1.2/50 µs, 0.5 Ws IEC 255-4, Cl. II Permissible commonmode voltage: 100 V, 50 z Environmental conditions Climatic rating: Transportation and storage temperature: 40 to 80 C Standard version Temperature 25 to 70 C nnual mean relative humidity 90% or version with improved climatic rating Temperature 40 to 70 C nnual mean relative humidity 95% Ex-version Temperature 40 to 60 C at T6 resp. 40 to 75 C at T5 Table 3: Specification and ordering information Order Code 707 Features, Selection *SCODE no-go 1. Version of the transmitter 1) Standard, 1....... Measuring output non intrinsically safe 2) EEx ia IIC T6, TEX B 2....... Measuring output intrinsically safe 6) Ex ia IIC T6, FTZU (Czech republic) B 6....... Measuring output intrinsically safe 9) Other versions on request B 9....... 2. Sense of rotation 1) Clockwise D. 1...... 2) Counterclockwise D. 2...... 3) V characteristic E. 3...... 4) Both senses of rotation, marked and calibrated M. 4...... Lines 1 and 2: Instruments with ranges 0 5 to 0 150 are usable in both senses of rotation. Instruments with ranges 0 > 150 to 0 270 can be changed to the other direction. (Beginning and end of the measuring range must be readjusted) Sense of rotation for transmitters with additional gear see Feature 13 and 14 Line 3: V characteristic not possible for instruments with gear Line 4: For measuring ranges 90 only Camille Bauer 4

Order Code 707 Features, Selection *SCODE no-go 3. Measuring range (measuring input) 1) 0... 10 E 1....... 2) 0... 30 E 2....... 3) 0... 60 E 3....... 4) 0... 90 E 4....... 5) 0...180 EM 5....... 6) 0...270 EM 6....... 9) Non-standard [ ] E 9....... 0... 5 to 0...< 270 ) V characteristic [± ] DM....... Line : Specify start M and end M E of measuring range! Observe the limits for (M [± ] 10 and M E [± ] 150) and give both angles separated by an oblique stroke, e.g. [± ] 15 / 90! m 20 10 0 150 90 15 0 15 90 150 Example of a V characteristic for the measuring range [± ] 15 / 90 and an output range of 0...20 m 4. Output signal (measuring output) ) 0 1 m, 3- or 4-wire connection....... B) 0 5 m, 3- or 4-wire connection. B...... C) 0 10 m, 3- or 4-wire connection. C...... D) 4 20 m, 2-wire connection. D...... or 0 20 m, 3- or 4-wire connection (adjustable with potentiometer) E) 4 20 m, 3- or 4-wire connection. E...... F) 0 20 m, 4-wire connection L. F...... Z) Non-standard, 3- or 4-wire connection [m]. Z...... 0 > 1.00 to 0 < 20 Lines to Z: max. see Section Technical data. 4-wire connection, with electric isolation only possible with DC/C power supply (C/DC power pack). 2-, 3- or 4-wire connection, without electric isolation only possible with DC power supply. Line F: Only possible with DC/C power supply (C/DC power pack) 5. Improved climatic rating 1) 24 60 V DC/C, with electric isolation F B.. 1..... 2) 85 230 V DC/C, with electric isolation F B.. 2..... ) 12 33 V DC, without electric isolation K BL....... B) 12 30 V DC (Ex), without electric isolation K L.. B..... Lines 1 and 2: Not possible for DC/C power supply at output signal Feature 4, line D! Camille Bauer 5

Order Code 707 Features, Selection *SCODE no-go 6. Mounting mode 0) Without foot, without flange 0....... 1) With foot (mounted) 1....... 2) With flange (mounted) 2....... 7. Material of transmitter rear cover / Routing of connecting cable 1) Plastic / connector less cable plug,. 1...... socket mounted for cable routed to the rear (see Fig. 7, but less plug) 2) Plastic / connector less cable plug, socket mounted for cable. 2...... routed to the front (see Fig. 8, but less plug) 3) Plastic / connector with cable plug,. 3...... cable routed to the rear (see Fig. 7) 4) Plastic / connector with cable plug,. 4...... cable routed to the front (see Fig. 8) 5) Metal / screw terminals and PG 11 glands (see Fig. 9). 5...... Line 5: Recommended for DC/C power supply, 4-wire connection with electric isolation 8. Special features 0) Without Y.. 0..... 1) With.. 1..... Without special features (line 0): Order code complete. With special features (line 1): The features to be omitted must be replaced by an oblique stroke (/) in the order code until reaching the required features 9. Settings (span adjustment) ) Extended setting range 5% / 60% Y....... Restriction: for angle 60, supplementary error 0.2% (also possible on versions with additional gear) 10. Improved climatic rating ) Temperature 40 to 70 C, annual mean relative humidity 95% BY....... J) With Ex version Y.... J... Temperature 40 to 60 C at T6 resp. 40 to 75 C at T5, annual mean relative humidity 95% 11. Marine version L) Version GL ( Germanischer Lloyd ) Y..... L.. 12. Increased vibration resistance M) Version with DC power supply, without electric isolation G FY...... M. N) Version with DC/C power supply (C/DC power pack), G KY...... N. with electric isolation 0 200 z, 25 g continuous, 30 g for 2 h 200 500 z, 15 g continuous Not possible with additional gear Camille Bauer 6

Order Code 707 Features, Selection *SCODE no-go 13. dditional gear 2 : 1 to 144 : 1 Choose the full scale value of KINX WT 707 (without gear) ME 150. Limit of error: 0.5% for ME 150 and 1.5% for ME > 150. Determine the required reduction ratio to the following formula: n 360 [ ] i = Reduction ratio i = ME [ ] n = No. of turns (end of range of object being measured) ME = Full scale value of KINX WT 707 (without gear). If ME is higher but max. 150 and i is as small as possible then the hysteresis error will be smaller. Example of calculation of the error of the hysteresis; known are: n = 4.1 rotations, i = 10, ME = 147.6 and j = approx. 1.0 j = gear backlash F % = 100% j i = 100 1,0 10 n 360 4,1 360 = approx. 0.68 % error of the hysteresis Gear backlash approx. 1.0 for 2 i 12,5 approx. 1.5 for 12,5 < i 60 approx. 2,0 for 60 < i 1600 1) Transformation 2 : 1 / J EGY 1....... 2) Transformation 4 : 1 / J EGY 2....... 3) Transformation 5 : 1 / J EGY 3....... 4) Transformation 6 : 1 / J EGY 4....... 5) Transformation 8 : 1 / J EGY 5....... ) Transformation 10 : 1 / J EGY....... B) Transformation 12 : 1 / J EGY B....... C) Transformation 12,5 : 1 / J EGY C....... D) Transformation 15 : 1 / J EGY D....... E) Transformation 16 : 1 / J EGY E....... F) Transformation 20 : 1 / J EGY F....... G) Transformation 22 : 1 / J EGY G....... ) Transformation 24 : 1 / J EGY....... J) Transformation 25 : 1 / J EGY J....... K) Transformation 30 : 1 / J EGY K....... L) Transformation 32 : 1 / J EGY L....... M) Transformation 36 : 1 / J EGY M....... N) Transformation 40 : 1 / J EGY N....... O) Transformation 50 : 1 / J EGY O....... P) Transformation 60 : 1 / J EGY P....... Q) Transformation 64 : 1 / J EGY Q....... R) Transformation 72 : 1 / J EGY R....... S) Transformation 75 : 1 / J EGY S....... T) Transformation 80 : 1 / J EGY T....... U) Transformation 100 : 1 / J EGY U....... V) Transformation 120 : 1 / J EGY V....... W) Transformation 144 : 1 / J EGY W....... Camille Bauer 7

Order Code 707 Features, Selection *SCODE no-go 14. dditional gear 150 : 1 to 1600 : 1 dditional gear built-in: 1) Transformation 150 : 1 / EGJY 1....... 2) Transformation 160 : 1 / EGJY 2....... 3) Transformation 180 : 1 / EGJY 3....... 4) Transformation 200 : 1 / EGJY 4....... ) Transformation 240 : 1 / EGJY....... B) Transformation 250 : 1 / EGJY B....... C) Transformation 300 : 1 / EGJY C....... D) Transformation 330 : 1 / EGJY D....... E) Transformation 360 : 1 / EGJY E....... F) Transformation 375 : 1 / EGJY F....... G) Transformation 400 : 1 / EGJY G....... ) Transformation 450 : 1 / EGJY....... J) Transformation 480 : 1 / EGJY J....... K) Transformation 500 : 1 / EGJY K....... L) Transformation 550 : 1 / EGJY L....... M) Transformation 600 : 1 / EGJY M....... N) Transformation 660 : 1 / EGJY N....... O) Transformation 720 : 1 / EGJY O....... P) Transformation 750 : 1 / EGJY P....... Q) Transformation 800 : 1 / EGJY Q....... R) Transformation 880 : 1 / EGJY R....... S) Transformation 900 : 1 / EGJY S....... T) Transformation 1000 : 1 / EGJY T....... U) Transformation 1024 : 1 / EGJY U....... V) Transformation 1200 : 1 / EGJY V....... W) Transformation 1600 : 1 / EGJY W....... / The direction of rotation specified under 2. is not reversed by the reduction gear; / The direction of rotation specified under 2. is reversed by the reduction gear! *Lines with letter(s) under no-go cannot be combined with preceding lines having the same letter under SCODE. Table 4: Data on explosion protection II 2 G Order Code Type of protection Intrinsic safety Certificates Mounting location Marking of the instrument Instrument Measuring output 707-2 EEx ia IIC T6 U i I i P i C i = 30 V = 160 m = 1 W 10 nf L i = 0 Type Examination Certificate PTB 97 TEX 2271 Within the hazardous area 707-6 Ex ia IIC T6 Czech republic FTZU 98 Ex 0280 Camille Bauer 8

Electrical connections 2-, 3- or 4-wire connection without electric isolation 4-wire connection with electric isolation Bridge Bridge 1 6 2 5 3 4 43 2 1 1 6 2 3 5 4 43 2 1 ~ ~ ~ ~ and and 2-wire connection (4...20 m) 4-wire connection (different m signals) 2 1 6 5 4 3 43 2 1 = Measuring output = C/DC power supply = External resistance Settings 3-wire connection (different m signals) ZERO S1 SPN GOSSEN METRWTT CM MILLE BUER Zero S1 Span 1 6 2 5 3 4 4 3 2 1 Fig. 10. Position of settings. Left: Transmitter with plug-in connector. Right: Transmitter with screw terminals and cable glands. ZERO = Potentiometer for zero point SPN = Potentiometer for measuring range end value S1 = Switch for reversing direction of rotation for >150º. 4-wire connection (different m signals) = Measuring output...... as 2-wire connection (4...20 m, signal in output/powering circuit)... as 3- or 4-wire connection (different m signals) = DC power supply = 12...33 V resp. = 12...30 V with Ex version = External resistance Transmitters with the ordering code 707 D (see Table 3: Specification and ordering information ) are designed for either a 2-wire connection with an output range of 4 20 m or a 3- or 4-wire connection with an output range of 0 20 m. If, however, a transmitter be changed from one to the other (see Electrical connections ), the beginning and end of the measuring range, ZERO and SPN must be readjusted. switch is provided on angular transmitters with a measuring range > 150 for reversing the direction of rotation. It is marked S1. Standard accessories 1 Operating Instructions in three languages: German, French, English 1 Ex approval, for instruments in Ex version only Camille Bauer 9

Dimensional drawings Ø 62 f8 approx. 80.6 approx. 102.5 M6 15 76.5 approx. 25 141.5 approx. 49.5 82 ±0.2 102 Fig. 11. KINX WT 707 with plug-in connector. M6 15 Ø 62 f8 approx. 71 76.5 147 PG 11 82 ±0.2 102 Fig. 12. KINX WT 707 with screw terminals and cable glands. Ø 62 f8 approx. 80.6 approx. 102.5 M6 15 76.5 approx. 25 205.5 approx. 49.5 82 ±0.2 102 Fig. 13. KINX WT 707 with additional gear and plug-in connector. M6 15 approx. 71 Ø 62 f8 76.5 PG 11 82 ±0.2 211 102 Fig. 14. KINX WT 707 with additional gear, screw terminals and cable glands. Camille Bauer 10

102 6.5 15 approx. 80.6 approx. 102.5 60 approx. 25 approx. 49.5 56 61.5 36 71 ±0.2 1 Ø 9 119 90 ±0.2 141.5 114 Fig. 15. KINX WT 707 with plug-in connector and foot. 102 6.5 15 60 approx. 71 PG 11 56 61.5 1 36 71 ±0.2 Ø 9 119 90 ±0.2 147 114 Fig. 16. KINX WT 707 with screw terminals, cable glands and foot. 102 6.5 15 approx. 80.6 approx. 102.5 60 61.5 36 71 ±0.2 approx. 25 Ø 9 119 90 ±0.2 205.5 approx. 49.5 1 56 114 Fig. 17. KINX WT 707 with additional gear, plug-in connector and foot. 102 6.5 15 60 approx. 71 PG 11 56 61.5 36 71 ±0.2 119 1 Ø 9 90 ±0.2 211 114 Fig. 18. KINX WT 707 with additional gear, screw terminals, cable glands and foot. Camille Bauer 11

3.5 55 Ø 110 f7 approx. 80.6 approx. 102.5 9.5 65 11.5 approx. 25 141.5 approx. 49.5 130 ±0.2 160 Fig. 19. KINX WT 707 with plug-in connector and flange. 3.5 55 9.5 Ø 110 f7 approx. 71 65 11.5 147 PG 11 130 ±0.2 160 Fig. 20. KINX WT 707 with screw terminals, cable glands and flange. 3.5 55 Ø 110 f7 approx. 80.6 approx. 102.5 9.5 65 11.5 approx. 25 205.5 approx. 49.5 130 ±0.2 160 Fig. 21. KINX WT 707 with additional gear, plug-in connector and flange. 3.5 55 9.5 Ø 110 f7 approx. 71 65 11.5 211 PG 11 130 ±0.2 160 Fig. 22. KINX WT 707 with additional gear, screw terminals, cable glands and flange. Printed in Switzerland Subject to change without notice Edition 08.98 Data sheet No. WT 707 Le Camille Bauer Ltd. argauerstrasse 7 C-5610 Wohlen/Switzerland Phone 41 56 618 21 11 Fax 41 56 618 24 58 Telex 827 901 cbm ch Camille Bauer 12