Development of TOP counter for Super B factory

Similar documents
Development of the MCP-PMT for the Belle II TOP Counter

TOP R&D status. Noriaki Sato (Nagoya Univ.) Super B-Factory Workshop in Hawaii. Status MCP-PMT R&D Summary

Performance of the MCP-PMTs of the TOP counter in the first beam operation of the Belle II experiment

R & D for Aerogel RICH

Improvement of the MCP-PMT performance under a high count rate

HAPD Status. S. Nishida KEK. Dec 11, st Open Meeting of the SuperKEKB collaboration. HAPD Status. 1st SuperKEKB Meeting 1

Timing and cross-talk properties of Burle multi-channel MCP PMTs

MCP-PMT status. Samo Korpar. University of Maribor and Jožef Stefan Institute, Ljubljana Super KEKB - 3st Open Meeting, 7-9 July 2009

Extension of the MCP-PMT lifetime

A high resolution TOF counter - a way to compete with a RICH detector?

SiPMs as detectors of Cherenkov photons

TOP counter for Belle II - post installation R&Ds

Seminar. BELLE II Particle Identification Detector and readout system. Andrej Seljak advisor: Prof. Samo Korpar October 2010

itop System Overview Kurtis Nishimura University of Hawaii October 12, 2012 US Belle II Firmware Review

PID summary. J. Va vra, SLAC. - Barrel PID - Forward PID

Electronic Readout System for Belle II Imaging Time of Propagation Detector

Proximity focusing RICH with flat pannel PMTs as photon detector

Multianode Photo Multiplier Tubes as Photo Detectors for Ring Imaging Cherenkov Detectors

Pixel hybrid photon detectors

MCP photon detectors studies for the TORCH detector

Development of large readout area, high time resolution RPCs for LEPS2 at SPring-8

Status and Perspectives of Vacuum-based Photon Detectors

The HERA-B Ring Imaging Cerenkov ˇ Detector

ARTICLE IN PRESS. Nuclear Instruments and Methods in Physics Research A

HERA-B RICH. Samo Korpar

Timing and cross-talk properties of BURLE multi-channel MCP PMTs

Particle ID in the Belle II Experiment

RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab. A. Margaryan

Particle identification at Belle-II

PoS(LHCP2018)031. ATLAS Forward Proton Detector

Performance of 8-stage Multianode Photomultipliers

Readout ASICs and Electronics for the 144-channel HAPDs for the Aerogel RICH at Belle II

The DIRC-like TOF : a time-of-flight Cherenkov detector for particle identification at SuperB

HF Upgrade Studies: Characterization of Photo-Multiplier Tubes

Production of HPDs for the LHCb RICH Detectors

CHAPTER 9 POSITION SENSITIVE PHOTOMULTIPLIER TUBES

MCP-PMT timing property for single photons

Studies on High QE PMT

Silicon Photomultiplier

Use of a Hybrid Photo Detector (HPD) in the MAGIC micro power LIDAR system

The MUSE experiment. Technical Overview. Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem

Stato del progetto RICH di LHCb. CSN1 Lecce, 24 settembre 2003

Development of a sampling ASIC for fast detector signals

A Novel Design of a High-Resolution Hodoscope for the Hall D Tagger Based on Scintillating Fibers

Contents. The AMADEUS experiment at the DAFNE collider. The AMADEUS trigger. SiPM characterization and lab tests

Scintillation Counters

5. Scintillation counters

Investigation of a Transmission-Line Readout for Building PET Detector Modules

arxiv: v1 [physics.ins-det] 23 Dec 2018

Characterization of 18mm Round and 50mm Square MCP-PMTs

Scintillator/WLS Fiber Readout with Geiger-mode APD Arrays

BaBar and PEP II. Physics

PoS(PD07)035. Development of 144 Multi-Anode HPD for Belle Aerogel RICH Photon Detector

Institute for Particle and Nuclear Studies, High Energy Accelerator Research Organization 1-1 Oho, Tsukuba, Ibaraki , Japan

Overall Design Considerations for a Detector System at HIEPA

Transmission-Line Readout with Good Time and Space Resolution for Large-Area MCP-PMTs

RP220 Trigger update & issues after the new baseline

5. Scintillation counters

Progress on development of the new FDIRC PID detector

A High-Granularity Timing Detector for the Phase-II upgrade of the ATLAS Detector system

The detector system of the EPOS system

Properties of Injection-molding Plastic Scinillator for Fiber Readout

Development of Large Area and of Position Sensitive Timing RPCs

The 1st Result of Global Commissioning of the ATALS Endcap Muon Trigger System in ATLAS Cavern

UFSD: Ultra-Fast Silicon Detector

Silicon Photo Multiplier SiPM. Lecture 13

Lecture 11. Complex Detector Systems

UFSD: Ultra-Fast Silicon Detector

CHAPTER 8 PHOTOMULTIPLIER TUBE MODULES

Introduction Test results standard tests Test results extended tests Conclusions

A Fast Waveform-Digitizing ASICbased DAQ for a Position & Time Sensing Large-Area Photo-Detector System

The HPD DETECTOR. Michele Giunta. VLVnT Workshop "Technical Aspects of a Very Large Volume Neutrino Telescope in the Mediterranean Sea"

Trigger Rate Dependence and Gas Mixture of MRPC for the LEPS2 Experiment at SPring-8

Muons & Particle ID. Muon/PID Studies

PMT tests at UMD. Vlasios Vasileiou Version st May 2006

A tracking detector to study O(1 GeV) ν μ CC interactions

Buffered LABRADOR (BLAB3) Design Review. Gary S. Varner 4 NOV 09

LaBr 3 :Ce scintillation gamma camera prototype for X and gamma ray imaging

Shintake Monitor Nanometer Beam Size Measurement and Beam Tuning

Polarimetry Concept Based on Heavy Crystal Hadron Calorimeter

Fast Timing Electronics

Performance of High Pixel Density Multi-anode Microchannel Plate Photomultiplier tubes

Study of the ALICE Time of Flight Readout System - AFRO

AMS-02 Anticounter. Philip von Doetinchem I. Physics Institute B, RWTH Aachen Bad Honnef, August 2007

Simulation studies of a novel, charge sharing, multi-anode MCP detector

The LHCb Experiment. Experiment and what comes after. O. Ullaland Ljubljana January Theodor Kittelsen, Soria Moria (with modifications)

KLM detector for SuperB

Super Belle CDC. Basic design Electronics. Wire stringing method Schedule. Shoji Uno (KEK) Dec-12 th, Test of pre-amplifier chips

A DAQ readout for the digital HCAL

Commissioning Status and Results of ATLAS Level1 Endcap Muon Trigger System. Yasuyuki Okumura. Nagoya TWEPP 2008

Optical Module in KM3NeT

MICE PID & trigger Detectors

DETECTORS Important characteristics: 1) Wavelength response 2) Quantum response how light is detected 3) Sensitivity 4) Frequency of response

MPD. Fast Forward Detector

Components of Optical Instruments. Chapter 7_III UV, Visible and IR Instruments

PoS(PD07)026. Compact, Low-power and Precision Timing Photodetector Readout. Gary S. Varner. Larry L. Ruckman. Jochen Schwiening, Jaroslav Va vra

GSPC detectors development for neutron reflectometry and SANS Instruments WP22 / Task 22.2

Gas Electron Multiplier 2. Detectors Gas Electron Multiplier (GEM) is a thin insulating foil which have thin electrodes on both sides and many

Advances in microchannel plate detectors for UV/visible Astronomy

event physics experiments

Transcription:

2009/5/11-13 Workshop on fast Cherenkov detectors - Photon detection, DIRC design and DAQ Development of TOP counter for Super B factory - Introduction - Design study - Focusing system - Prototype development - Beam test - Summary K. Inami (Nagoya university)

Introduction TOP (Time Of Propagation) counter Developing to upgrade the barrel PID detector For Super B factory L peak ~10 35~36 /cm 2 /s, 20~100 times higher than present Need to work with high beam BG To improve K/p separation power Physics analysis B pp/kp, rg, Knn etc. Flavor tag Full reconstruction 1.2m 1.5T e - 8.0GeV 2.6m e + 3.5GeV Target; 4s for 4 GeV/c Side view of Belle II detector 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 2

TOP counter Cherenkov ring in quartz bar Reconstruct ring image using ~20 photons on the screen reflected inside the quartz radiator as a DIRC. Photons are detected with photon detectors. Different ring image for the pion and kaon of the same momentum Need large screen... 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 3

TOP counter 2D position information Position+Time Compact detector! Linear array PMT (~5mm) Time resolution s~40ps Simulation 2GeV/c, q=90 deg. ~2m ~200ps Different opening angle for the same momentum Different propagation length(= propagation time) + TOF from IP works additively. 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 4 K p

Old test counter Beam test @ KEK PS p2 line 3 GeV/c p - beam q in =f in =90 degree Test counter 1mm pitch readout Clear ring image Reasonable time resolution Enough bar quality 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 5

TOP counter Quartz: 255cm L x 40cm W x 2cm T Focus mirror at 47.8deg. to reduce chromatic dispersion Multi-anode MCP-PMT Linear array (5mm pitch), Good time resolution (<~40ps) Measure Cherenkov ring image with timing information MCP-PMT 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 6

Multi-anode MCP-PMT (1) SL10 R&D with Hamamatsu for TOP counter Size 27.5 x 27.5 x 14.8 mm Effective area 22 x 22 mm(64%) Photo cathode Multi-alkali Q.E. ~20%(l=350nm) MCP Channel diameter 10 mm Number of MCP stage 2 Al protection layer No Aperture ~60% Anode 4 channel linear array Anode size (1ch) 5.3 x 22 mm Anode gaps 0.3 mm Large effective area 64% by square shape Position information 4ch linear anode (5mm pitch) 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 7

Multi-anode (2) Raise time ~400ps Single photon detection Fast raise time: ~400ps Gain=1.5x10 6 @B=1.5T T.T.S.(single photon): ~30ps @B=1.5T Position resoltion: <5mm Correction eff.: ~50% Nucl. Instr. Meth. A528 (2004) 768. T.T.S.: s~30ps Basic performance is OK! Same as single anode MCP-PMT 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 8

Chromaticity Detection time depending on the wavelength of Cherenkov photons Worse time resolution Worse ring-image separation Propagation velocity depending on l in the quartz bar 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 9

Chromatic dispersion Variation of propagation velocity depending on the wavelength of Cherenkov photons Light propagation velocity inside quartz GaAsP photo-cathode ( alkali p.c.) Higher quantum-efficiency at longer wavelength less chromatic error Photon sensitivity at longer wavelength shows the smaller velocity fluctuation. 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 10

GaAsP MCP-PMT development Square-shape MCP-PMT with GaAsP photo-cathode is developed with Hamamatsu Photonics. Prototype GaAsP photo-cathode Al protection layer 2 MCP layers f10mm hole 4ch anodes Slightly large structure Less effective area Performance test Time resolution PLP PMT ATTN AMP DIV λ=407nm Jitter~10ps FILTER BLACK BOX there 100mV Target structure 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 11 DISC 36dB DISC there 20mV CAMAC ADC GATE START 25ps/1bin TDC

GaAsP MCP-PMT performance Wave form, ADC and TDC distributions for single photon pedestal single photon peak TTS~35ps Single p.e. 0.5ns/div 20mV/div Gain~ 0.64 10 6 Enough gain to detect single photo-electron Good time resolution (TTS=35ps) for single p.e. Need to improve production rate 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 12

Focusing TOP Remaining chromatic effect makes ~100ps fluctuation for TOP. Use l dependence of Cherenkov angle to correct chromaticity Focusing system to measure q c l q c y position Reconstruct ring image from 3D information (time, x and y). ー θ c ( λ ) = cos 1 1 ( ) n( λ ) β Mirror image Focus Mirror Side view 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 13

Focusing TOP (2) Dq c ~1.2mrad over sensitive l range Dy~20mm (~quartz thickness) We can measure l dependence and obtain good separation even with narrow mirror and readout plane, because of long propagation length. Dq c ~1.2mrad Not need focusing block Not need fine readout channels Focusing mirror Virtual readout screen 22mm x 5mm matrix 1850mm 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 14

Performance of focusing TOP K/p separation power GaAsP photo-cathode(+>400mm filter), CE=36% 4.3s separation for 4GeV/c 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 15

Expected performance K/p separation power Current Belle GaAsP photo-cathode + Focusing mirror >4s K/p upto 4 GeV/c, q<90, <2% fake rate 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 16

Design studies Better performance and robustness for additional fluctuation Start timing T 0, tracking resolution, beam BG etc. Simple structure Less systematic error for analysis (Cost reduction) TOP with small standoff block (proposed by Hawaii univ.) Larger readout plane Relax the complicated ring image Reduce the occupancy of PMT hit channels 2 readout 1 readout Standoff 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 17

Performance check Ideal case (Preliminary) MCP-PMT GaAsP CE=35% l>400nm T 0 fluctuation; Robust for big DTOP region (Time resolution is not good due to Chromaticity.) T 0 : 10ps jitter 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 18

Performance check With 10ps T 0 jitter GaAsP, CE=35% l>400nm (Preliminary) Multi-alkali, CE=60% l>350nm Propagation length optimized for QE variation is limited. 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 19

Prototype development Demonstration of the performance Glued Glued PMT 915mm 400mm quartz 20mm Prototype overview 400mm 20mm 915mm quartz 400mm 20mm Photon detector Time resolution Efficiency Filter (l>400nm) Suppression of chromatic dispersion Quartz radiator (Fused silica) Flatness:<1.2mm/m Roughness:0.5nm 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 20

QE [%] Photon detector Square-shape multi-anode MCP-PMT Multi-alkali photo-cathode Single photon detection Fast raise time: ~400ps Gain=1.5x10 6 @B=1.5T T.T.S.(single photon): ~35ps @B=1.5T Position resoltion: <5mm Semi-mass-production (14 PMTs) σ=34.2±0.4ps QE:24%@400nm TDC [1count/25ps] TTS<40ps for all channels Wavelength [nm] Ave. QE:17%@400nm 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 21

MCP-PMT + CFD CFD on PMT module Digitize with low noise Low PMT gain operation Robust against cross-talk Able to determine PMT timing by (approximately) pulse peak. 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 22

PMT module HV divider + AMP + Discriminator Small size (28mm W ) Prototype Fast AMP (MMIC, 1GHz, x20) Fast comparator (180ps propagation) CFD with pattern delay Performance Test pulse ~5ps resolution MCP-PMT s<40ps Working well amp input low voltage supply AMP+CFD comparator to ADC to TDC 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 23

Time resolution [ps] Quartz radiator Made by Okamoto optics Check the quality for time resolution Single photon pulse laser l=407nm MCP-PMT Several incident position No degradation of time resolution Enough quartz quality Quartz s<40ps MCP-PMT 47.2 deg. MCP-PMT Line 1 Line 2 Line 3 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 24 Propagation length [mm]

QE [%] Check chromatic effect by beam test Light propagation velocity inside quartz Wavelength [nm] Range of detectable wavelength of Cherenkov photons Time fluctuation of the Cherenkov ring image Time resolution depends on the propagation length. Check the degradation of time resolution by beam test 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 25

Beam test At Fuji beam line in June and Dec. Using real size quartz and MCP-PMT MCP-PMT: Multi-alkali p.c., C.E.=60% Quartz + support jig TOP counter Quartz bar (1850 400 20mm) Timing counter 10mm f quartz + MCP-PMT s t0 < 15ps MWPC 1 MWPC 2 Check Ring image Number of photons Time resolution MCP-PMT (10PMT) Trigger counter Lead glass + Finemesh PMT 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 26

Timing counter Based on our high resolution TOF s=6.2ps with 6mm MCP-PMT, Cherenkov light in quartz and special electronics Time difference btw two counters Check time resolution DT distribution 14.8ps 10mm f quartz + MCP-PMT Limited by elec. 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 27

TDC [1count/25ps] TDC [1count/25ps] Ring image Data Simulation (4) (3) (2) (1) ch ch Proper ring image Same time interval with simulation quartz (4) 915mm (2) 358mm (1) Beam 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 28

Number of detected photons Ave. num. of photons:15.7 Normal incidence (90 deg.) Num. of photons Obtained number of photons as expected We can expect ~22 photons/event, if we use 14 PMTs. Normalized by active area (10 14 PMTs) 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 29

Time resolution TDC distribution of ch.29 Compare with the distribution expected by a simulation including PMT resolution and chromatic dispersion effect Data 1 st 2 nd Simulation 3 rd 1 st 2 nd 3 rd quartz ch29 Focus mirror [1count/25ps] Data Simulation Resolution(1 st peak) 76.0±2.0 [ps] 77.7±2.3 [ps] [1count/25ps] 1850mm 875mm 3 rd 2 nd 1 st Beam (875mm ) MCP-PMT(ch29) 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 30

Separation (s) [ps] Time resolution 1 st peak time resolution vs. ch Data Simulation Ave. of data:70.6ps Ave. of simulation:74.6ps Separation power vs. ch Separation Power s DTOF DTOP s top N det 4s separation achieved If we calculate from time resolution and number of photons for normal incidence condition. 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 31

Time resolution [ps] Time resolution vs. propagation length Check time resolution For several incidence condition and channel Simulation Propagation length [mm] Data agrees well with simulation expectation. Confirmed the level of chromatic dispersion effect 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 32

Summary R&Ds of Cherenkov detector are in progress! TOP counter for barrel PID upgrade at Belle II experiment Cherenkov ring imaging with precise timing information (s<40ps) Several design studies are going. MCP-PMT R&D with Hamamatsu Enough performance for TOP counter Prototype development Multi-anode MCP-PMT Integrated module with amplifier and CFD Quartz radiator Enough quartz quality for single photon detection Performance test with beam Proper ring image, number of detected photons (15.7 photons) Time resolution as expected by simulation Confirmed chromatic dispersion effect 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 33

2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 34

MCP-PMT Timing properties under B=0~1.5T parallel to PMT HPK6 BINP8 HPK10 Burle25 MCP-PMT HPK6 R3809U-50-11X BINP8 N4428 HPK10 R3809U-50-25X Burle25 85011-501 PMT size(mm) 45 30.5 52 71x71 Effective size(mm) 11 18 25 50x50 Channel diameter(mm) 6 8 10 25 Length-diameter ratio 40 40 43 40 Max. H.V. (V) 3600 3200 3600 2500 photo-cathode multi-alkali multi-alkali multi-alkali bi-alkali Q.E.(%) (l=408nm) 26 18 26 24 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 35

Pulse response Pulse shape (B=0T) Fast raise time (~500ps) Broad shape for BINP8 Due to mismatch with H.V. supply divider No influence for time resolution Gain v.s. B-field Small channel diameter shows high stability against B-field. Explained by relation btw hole size and Larmor radius of electron motion under B-field. 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 36

Time response TTS v.s. B-field Small channel diameter shows high stability and good resolution. Single photon TTS v.s. Gain For several HV and B-field conditions 30~40ps resolution was obtained for gain>10 6 Hole size need <~10mm to get time resolution of ~30ps under 1.5T B-field. Single photon 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 37

Lifetime How long can we use MCP-PMT under high hit rate? (Nucl. Instr. Meth. A564 (2006) 204.) HPK (x2) Russian (x5) Al protection O X O X 55- Correction eff. 37% 65% 40-60 60% Effective area 11mm f 18mm f Gain 1.9x10 6 1.5x10 6 3~4x10 6 TTS 34ps 29ps 30~40ps Photo-cathode Multi-alkali (NaKSbCs) Quantum eff. at 400nm 21% 19% 16-20% Bias angle 13deg 5deg Light load by LED pulse (1~5kHz) 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 38 20~100 p.e. /pulse (monitored by normal PMT)

Lifetime - Q.E. - Relative Q.E. by single photon laser Without Al protection Drop <50% within 1yr. With Al protection Long life Not enough for Russian PMTs Enough lifetime for HPK s MCP-PMT with Al protection layer 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 39

Lifetime - Q.E. vs wavelangth - Q.E. after lifetime test (Ratio of Q.E. btw. before,after) Large Q.E. drop at longer wavelength Number of Cherenkov photons;only 13% less (HPK w/al) Number of generated Cherenkov photon:~1/l 2 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 40

Lifetime - T.T.S. - Time resolution for single photon No degradation! Keep ~35ps Russian w/ Al(#32) Russian w/o Al (#6) -before -after s=31ps s=36ps s=43ps s=32ps HPK w/ Al s=29ps s=33ps HPK w/o Al s=34ps s=34ps 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 41

Lifetime - Gain - Estimate from output charge for single photon irradiation <10 13 photons/cm 2 Drop fast >10 13 photons/cm 2 Drop slowly Single photon detection: OK Can recover gain by increasing HV 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 42

Rate dependence Gain vs. photon rate For high intensity beam Gain drop for high rate >10 5 count/cm 2 /s Due to lack of elections inside MCP holes Dep. on RC variables MCP resistance (M cm 2 ) MCP capacitance (pf/cm 2 ) SL10 HPK6 BINP 96 143 380~1000 16 31 24~39 Enough for TOP counter 2009/5/11-13 Workshop on fast Cherenkov detectors at Giessen 43