The MUSE experiment. Technical Overview. Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem

Similar documents
Stato del progetto RICH di LHCb. CSN1 Lecce, 24 settembre 2003

DAQ & Electronics for the CW Beam at Jefferson Lab

MuLan Experiment Progress Report

Status of the PRad Experiment (E )

A Novel Design of a High-Resolution Hodoscope for the Hall D Tagger Based on Scintillating Fibers

Micromegas for muography, the Annecy station and detectors

Study of the ALICE Time of Flight Readout System - AFRO

arxiv: v1 [physics.ins-det] 28 Feb 2018

A Real Time Digital Signal Processing Readout System for the PANDA Straw Tube Tracker

HPS Upgrade Proposal

1.1 The Muon Veto Detector (MUV)

Status of the PRad Experiment (E )

LHCb Preshower(PS) and Scintillating Pad Detector (SPD): commissioning, calibration, and monitoring

The LHCb Upgrade BEACH Simon Akar on behalf of the LHCb collaboration

Overall Design Considerations for a Detector System at HIEPA

Contents. Why waveform? Waveform digitizer : Domino Ring Sampler CEX Beam test autumn 04. Summary

Lecture 11. Complex Detector Systems

Electronic Readout System for Belle II Imaging Time of Propagation Detector

Cosmic Rays in MoNA. Eric Johnson 8/08/03

Hall D Report. E.Chudakov 1. PAC43, July Hall D Group Leader. E.Chudakov PAC43, July 2015 Hall D Report 1

Status of the LHCb Experiment

Development of large readout area, high time resolution RPCs for LEPS2 at SPring-8

Performance of the MCP-PMTs of the TOP counter in the first beam operation of the Belle II experiment

GEM beam test for the BESIII experiment

A tracking detector to study O(1 GeV) ν μ CC interactions

Contents. The AMADEUS experiment at the DAFNE collider. The AMADEUS trigger. SiPM characterization and lab tests

Status of UVa

Timing and cross-talk properties of Burle multi-channel MCP PMTs

arxiv: v1 [physics.ins-det] 25 Oct 2012

EUDET Pixel Telescope Copies

Data Acquisition System for the Angra Project

RF Time Measuring Technique With Picosecond Resolution and Its Possible Applications at JLab. A. Margaryan

Polarimetry Concept Based on Heavy Crystal Hadron Calorimeter

The CMS Outer HCAL SiPM Upgrade.

Muons & Particle ID. Muon/PID Studies

Development of High Granulated Straw Chambers of Large Sizes

The High-Voltage Monolithic Active Pixel Sensor for the Mu3e Experiment

arxiv: v1 [physics.ins-det] 9 May 2016

Particle ID in the Belle II Experiment

Design and Construction of Large Size Micromegas Chambers for the ATLAS Phase-1 upgrade of the Muon Spectrometer

DHCAL Prototype Construction José Repond Argonne National Laboratory

PoS(LHCP2018)031. ATLAS Forward Proton Detector

Construction and Performance of the stgc and Micromegas chambers for ATLAS NSW Upgrade

MICE PID & trigger Detectors

Plans for RPC DHCAL Prototype. David Underwood Argonne National Laboratory

Triple GEM detector as beam monitor Monitors for Crystal experiment at SPS A compact Time Projection chamber with GEM

Performance of 8-stage Multianode Photomultipliers

itop System Overview Kurtis Nishimura University of Hawaii October 12, 2012 US Belle II Firmware Review

Diamond sensors as beam conditions monitors in CMS and LHC

The HERA-B Ring Imaging Cerenkov ˇ Detector

optimal hermeticity to reduce backgrounds in missing energy channels, especially to veto two-photon induced events.

Construction and Performance of the stgc and MicroMegas chambers for ATLAS NSW Upgrade

MCP-PMT status. Samo Korpar. University of Maribor and Jožef Stefan Institute, Ljubljana Super KEKB - 3st Open Meeting, 7-9 July 2009

CMS Note Mailing address: CMS CERN, CH-1211 GENEVA 23, Switzerland

GEM Module Design for the ILD TPC. Astrid Münnich

GEM chambers for SoLID Nilanga Liyanage. University of Virginia

Gas Electron Multiplier Detectors

GEM Detector Assembly, Implementation, Data Analysis

Seminar. BELLE II Particle Identification Detector and readout system. Andrej Seljak advisor: Prof. Samo Korpar October 2010

Motivation Overview Grounding & Shielding L1 Trigger System Diagrams Front-End Electronics Modules

`First ep events in the Zeus micro vertex detector in 2002`

Trigger Rate Dependence and Gas Mixture of MRPC for the LEPS2 Experiment at SPring-8

PID summary. J. Va vra, SLAC. - Barrel PID - Forward PID

CLAS12 First Experiment Workshop Report

Resistive Micromegas for sampling calorimetry

Design of the forward straw tube tracker for the PANDA experiment

HERA-B RICH. Samo Korpar

Scintillators as an external trigger for cathode strip chambers

The LHCb VELO Upgrade. Stefano de Capua on behalf of the LHCb VELO group

The NA62 rare kaon decay experiment Photon Veto System

The PERDaix Detector. Thomas Kirn I. Physikalisches Institut B. July 5 th 2011, 6 th International Conference on New Developments In Photodetection

Test Beam Measurements for the Upgrade of the CMS Phase I Pixel Detector

Track Triggers for ATLAS

A Fast Waveform-Digitizing ASICbased DAQ for a Position & Time Sensing Large-Area Photo-Detector System

The on-line detectors of the beam delivery system for the Centro Nazionale di Adroterapia Oncologica(CNAO)

Data Compression and Analysis Methods for High- Throughput Radiation Detector Systems

Scintillation Counters

Goal of the project. TPC operation. Raw data. Calibration

Performance of High Pixel Density Multi-anode Microchannel Plate Photomultiplier tubes

Main Detectors for PREX and CREX

Beam Condition Monitors and a Luminometer Based on Diamond Sensors

1 Status of the Hall A Møller Polarimeter

irpc upgrade project for CMS during HL-LHC program

Time-of-flight PET with SiPM sensors on monolithic scintillation crystals Vinke, Ruud

ASIC/TRB Readout Status in Jülich

ATLAS Muon Trigger and Readout Considerations. Yasuyuki Horii Nagoya University on Behalf of the ATLAS Muon Collaboration

Full characterization tests of Micromegas with elongated pillars

Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4 Q1-2 Q3-4. Final design and pre-production.

Shower Max Detector Plans for MOLLER

High granularity scintillating fiber trackers based on Silicon Photomultiplier

Uva GEM R&D Update. Nilanga Liyanage

Development of TOP counter for Super B factory

Micromegas calorimetry R&D

IRST SiPM characterizations and Application Studies

A large area TOF-tracker

Development of Large Area and of Position Sensitive Timing RPCs

High counting rate, differential, strip read-out, multi gap timing RPC

The Multigap RPC: The Time-of-Flight Detector for the ALICE experiment

Tracking Detectors for Belle II. Tomoko Iwashita(Kavli IPMU (WPI)) Beauty 2014

Gas Electron Multiplier 2. Detectors Gas Electron Multiplier (GEM) is a thin insulating foil which have thin electrodes on both sides and many

Transcription:

The MUSE experiment Technical Overview Guy Ron (for the MUSE collaboration) Hebrew University of Jerusalem

MUSE is not your garden variety scattering experiment Low beam flux Large angle, non-magnetic detectors. Secondary beam (large emittance) Tracking of beam particles to target. Mixed beam Identification of beam particle in trigger. Scattered Particle Scintillators Target SciFi Beam Cerenkov Beam Scint. Target Chamber GEMs Veto Scintillator Straw Chambers SVN r380 K.Myers 15/Jan/2014

Experiment Overview PSI πm1 channel 115, 153, 210 MeV/c mixed beams of e ±, ± and π ± 20 o - 100 o Scattered Particle Scintillators Beam Scint. Q 2 0.002-0.07 GeV 2 About 5 MHz total beam flux, 2-15% 's, 10-98% e's, 0-80% π's Straw Chambers Beam monitored with SciFi, beam Cerenkov, GEMs Scattered particles detected with straw chambers and scintillators Target SciFi Beam Cerenkov Target Chamber GEMs Veto Scintillator SVN r380 K.Myers 15/Jan/2014 Not run like a normal cross section experiment - 7-8 orders of magnitude lower luminosity. But there are some benefits: count every beam particle, no beam heating of target, low rates in detectors,...

Experiment Overview 20 o - 100 o Q 2 0.0015-0.08 GeV 2 0.256-0.94 Essentially same coverage for all beam particles.

Minimal R&D. MUSE Design Choices Use existing designs as much as possible. Reuse equipment whenever possible. Maximal cost reduction. Modular construction (can run dress rehearsal with fewer components). Performance Requirements Angle reconstruction to few mr (limited by multiple scattering). Reduce multiple scattering as much as possible. Mostly timing used for PID - O(50ps) time resolution. 99% or better online π rejection.

Beamline Detectors Scattered Particle Scintillators Beam Scint. Straw Chambers Target SciFi Beam Cerenkov GEMs Veto Scintillator Target Chamber SVN r380 K.Myers 15/Jan/2014

Detectors - beam Cerenkov Improve timing at target. Muon decay event rejection. 140ps achieved with cosmics (~110ps from geometrical). Estimate 25-50ps resolution can be reached. Crystals placed at Cernekov angle -> better timing from prompt photons. Fast MCP-PMT photon detection. Likely to use Sapphire/Plastic. MCP-PMT Quartz Bars Sapphire Bars

Detectors - SciFis One scintillating fiber array near target Precise timing at target, less precise than Cerenkov, but with higher segmentation and rate capability RF to target TOF for beam PID Provide GEM trigger, spatial info for multi-hit / multi-track selection, to identify triggering track 3 SciFi planes + walk correction gives ~300ps timing resolution. YUV plane arrangement 40 2mm circular fibers / plane Double sided readout with mapmt Multiplexed to reduce channel cross-talk

Prototyping at Tel Aviv Detectors - SciFis

Determine trajectory for scattering angle and Q 2. 70um Spatial resolution. Third GEM rejects ghost tracks. Existing detector repurposed from OLYMPUS experiment @ DESY. Detectors - GEMs GEMs installed @PSI

Detectors - Veto 8 Segment annular detector around target entrance window. Discriminate against muon decay events. Beam flux normalization. Veto to remove Møller electrons. Detectors - Beam line Scintillators

Target Scattered Particle Scintillators Beam Scint. Straw Chambers Target SciFi Beam Cerenkov GEMs Veto Scintillator Target Chamber SVN r380 K.Myers 15/Jan/2014

Target LH 2 target cell Thin windows to limit backgrounds Small enough to limit multiple scattering Big enough so all but tails of beam go through cryogen, not side walls. Current plan - 4 cm wide x 8 cm high x 4 cm long.! Low power system LN 2 baffles reduce heating. Snow prevention using baffles + extra space.

Scattered Particle Detectors Scattered Particle Scintillators Beam Scint. Straw Chambers Target SciFi Beam Cerenkov GEMs Veto Scintillator Target Chamber SVN r380 K.Myers 15/Jan/2014

Straw Tube Tracker

PANDA STT Based on ~1.5m long straws (1cm diameter). Close packed straws, w/ minimal gaps. ~30um thick straws -> low material budget. Mechanical stability provided by overpressuring straws to ~2bar - allows significantly lower material budget. 3kg brick

Gas Mixture Ar (90%)/CO2(10%) mixture selected - achieves design goals. Non toxic/non flammable - easy to deal with. Achieved ~150um resolution and better than 8kHz/cm.

Construction Procedure Wires: Straws cut to length. End caps glued and 1 wire end crimped. 12h glue hardening. Wire stretched w/ 50g weight and pressure raised (2bar). 2nd wire end crimped. Straw planes: Straws placed on jig. Each monolayer glued @ predefined points. Additional layers stacked on first layer. Final arrangement clamped in place. Procedure designed to allow straws/wires to be positioned at the 25um level.

Gas distribution Mixture/Pressure controlled by pressure controllers/gas flow controllers from Bronkhorst inc. Gas distribution to individual chambers from single mixing chamber.

MUSE Electronics Straws provide low charge signal, suitable for discrimination with front end PADIWA board. MUSE will use the standard PADIWA->TRB3 setup that is planned for all timing detectors. HV distribution / readout card for the straw chambers will be designed and prototyped @ HUJI e- shop.

MUSE Design The tracker design has been modified to accommodate the MUSE requirements. Design calls for 2 chambers on each side of the detector. 5X/5Y planes per chamber. X-planes likely closer to target to allow for better resolution in scattering angle. ~3000 straws total.

Scintillators

Scintillator Overview Produced by USC based on design for CLAS12 upgrade. State-of-the-art production lab @ USC already set up. Expect at least 6 bars/week production rate once design is finalized.

Scintillator Overview Vertically oriented bars, covering the full acceptance (20-100 deg) - in 2 walls. Scattered Particle Scintillators Beam Scint. Back wall increased in size to account for multiple scattering. Straw Chambers Target SciFi Beam Cerenkov GEMs Veto Scintillator Target Chamber SVN r380 K.Myers 15/Jan/2014

Scintillator Overview Scattered Particle Scintillators Beam Scint. Straw Chambers Target SciFi Beam Cerenkov Target Chamber GEMs Veto Scintillator SVN r380 K.Myers 15/Jan/2014

Scintillator Readout R9779 PMTs with double output last dynode + anode. Dynode (slower) output readout into QDC. Anode (fast) readout fed directly into PADIWA for discrimination and TDC. Time-walk correction based on QDC. Scintillator efficiency better than 99%.

Triggering and Data Acquisition Scattered Particle Scintillators Beam Scint. Straw Chambers Target SciFi Beam Cerenkov GEMs Veto Scintillator Target Chamber SVN r380 K.Myers 15/Jan/2014

GSI designed Time-to-Digital converters (25ps resolution). FPGAs as front end discriminator/amplifier. High channel density (256ch/board). ADC signals into standard CAEN architecture (v792). Custom designed signal splitters where needed. Triggering implemented on same architecture. TRB3 Timing @ least as good as CAEN V1290

Data Acquisition Data Acquisition based on standard PSI DAQ software (MIDAS). Trivial integration with PSI slow controls. Distributed frontend allow for high event rate (not limited by software/daq). Test runs carried out with individual modules of each type of component needed for the DAQ.

New Equipment Summary Detector Who Technology Beam SciFi Tel Aviv conventional GEMs Hampton detector exists Sapphire Cerenkov Rutgers prototyped (Albrow et al) Trigger Rutgers TRB3 based Target Straw Tube Tracker Scintillators (including beam and veto) George Washington Hebrew U South Carolina conventional - very low power copy existing system (PANDA) copy existing system DAQ George Washington conventional, except TRB3