Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives

Similar documents
International Journal of Advance Engineering and Research Development

Study of Harmonics and THD of Nine Phase PWM Inverter Drive with CLC Filter for motor drive applications

ATYPICAL high-power gate-turn-off (GTO) currentsource

Speed Control of Induction Motor using Multilevel Inverter

A THREE PHASE SHUNT ACTIVE POWER FILTER FOR HARMONICS REDUCTION

Enhanced Performance of Multilevel Inverter Fed Induction Motor Drive

MODELLING AND SIMULATION OF DIODE CLAMP MULTILEVEL INVERTER FED THREE PHASE INDUCTION MOTOR FOR CMV ANALYSIS USING FILTER

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

Harmonics Elimination Using Shunt Active Filter

IN HIGH-POWER (up to hp) ac motor drives using

Mitigation of Harmonics and Interharmonics in VSI-Fed Adjustable Speed Drives

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

International Journal of Advance Engineering and Research Development

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

CHAPTER 6 THREE-LEVEL INVERTER WITH LC FILTER

Modeling and Analysis of Common-Mode Voltages Generated in Medium Voltage PWM-CSI Drives

SCOTT TRANSFORMER AND DIODE CLAMPED INVERTER FED INDUCTION MOTOR BASED ON FOC

Space Vector PWM Voltage Source Inverter Fed to Permanent Magnet Synchronous Motor

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Performance Analysis of Induction Motor Drive Fed by VSI for Various Modulation Index

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

ISSN Vol.03,Issue.42 November-2014, Pages:

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Simulation Analysis of Three Phase & Line to Ground Fault of Induction Motor Using FFT

Harmonics White Paper

Multi Level Inverter Based Active Power Filter for Harmonic Reduction

THE rapid development of power electronics in recent

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

ANALYSIS OF EFFECTS OF VECTOR CONTROL ON TOTAL CURRENT HARMONIC DISTORTION OF ADJUSTABLE SPEED AC DRIVE

Simulation of Three Phase Cascaded H Bridge Inverter for Power Conditioning Using Solar Photovoltaic System

International Journal of Research Available at

PERFORMANCE IMPROVEMENT OF CEILING FAN MOTOR USING VARIABLE FREQUENCY DRIVE WITH SEPIC CONVERTER

Comparative Study of Pulse Width Modulated and Phase Controlled Rectifiers

Modified Three-Phase Four-Wire UPQC Topology with Reduced DC-Link Voltage Rating

Control Of Shunt Active Filter Based On Instantaneous Power Theory

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

Study of Power Factor Correction in Single Phase AC-DC Converter

Introduction to Rectifiers and their Performance Parameters

Power Quality enhancement of a distribution line with DSTATCOM

Simulation Study of PWM Techniques for Voltage Source Converters

CHAPTER 4 MODIFIED H- BRIDGE MULTILEVEL INVERTER USING MPD-SPWM TECHNIQUE

DRIVE FRONT END HARMONIC COMPENSATOR BASED ON ACTIVE RECTIFIER WITH LCL FILTER

High Voltage DC Transmission 2

VFDs and Harmonics in HVAC Applications

COMPARATIVE ANALYSIS OF MULTIPULSE AC-DC CONVERTERS IN VCIMD

SVPWM Buck-Boost VSI

DIRECT TORQUE CONTROL OF THREE PHASE INDUCTION MOTOR BY USING FOUR SWITCH INVERTER

CHAPTER - 3 CONVENTIONAL SOURCE INVERTER FED INDUCTION MOTOR DRIVE. output voltage could be fixed or variable at a fixed or variable frequency.

Simulation & Implementation Of Three Phase Induction Motor On Single Phase By Using PWM Techniques

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Design and Simulation of DVR Used For Voltage Sag Mitigation at Distribution Side

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

IMPROVING THE OUTPUT OF CASCADED FIVE LEVEL MULTILEVEL INVERTER USING LOW PASS BROADNBAND FILTER

Z-SOURCE INVERTER BASED DVR FOR VOLTAGE SAG/SWELL MITIGATION

Analysis of Asymmetrical Cascaded 7 Level and 9 Level Multilevel Inverter Design for Asynchronous Motor

MODELING AND SIMULATON OF THREE STAGE INTERLEAVED BOOST CONVERTER BASED WIND ENERGY CONVERSION SYSTEM

Low Order Harmonic Reduction of Three Phase Multilevel Inverter

SHUNT ACTIVE POWER FILTER

VARIABLE FREQUENCY DRIVE

IJSTE - International Journal of Science Technology & Engineering Volume 2 Issue 12 June 2016 ISSN (online): X

IJSRD - International Journal for Scientific Research & Development Vol. 2, Issue 06, 2014 ISSN (online):

A Hybrid Cascaded Multilevel Inverter for Interfacing with Renewable Energy Resources

NPTEL

A Predictive Control Strategy for Power Factor Correction

Power Factor Improvement in Switched Reluctance Motor Drive

Hysteresis Controller and Delta Modulator- Two Viable Schemes for Current Controlled Voltage Source Inverter

Harmonic Analysis & Filter Design for a Novel Multilevel Inverter

PERFORMANCE ANALYSIS OF A NEW CONVERTER FOR SWITCHED RELUCTANCE MOTOR DRIVE WITH COMPONENT SHARING

REDUCTION OF THD IN POWER SYSTEMS USING STATCOM

Mitigating Voltage Sag Using Dynamic Voltage Restorer

Effective Harmonic Mitigation with Active Filters

ON-LINE NONLINEARITY COMPENSATION TECHNIQUE FOR PWM INVERTER DRIVES

Comparative Analysis of Space Vector Pulse-Width Modulation and Third Harmonic Injected Modulation on Industrial Drives.

Keywords Cascaded Multilevel Inverter, Insulated Gate Bipolar Transistor, Pulse Width Modulation, Total Harmonic Distortion.

Selective Harmonic Elimination (SHE) for 3-Phase Voltage Source Inverter (VSI)

Mitigation of Line Current Harmonics Using Shunt Active Filter With Instantaneous Real and Reactive Power Theory

II. L-Z SOURCE INVERTER

HARDWARE IMPLEMENTATION OF DIGITAL SIGNAL CONTROLLER FOR THREE PHASE VECTOR CONTROLLED INDUCTION MOTOR

Svpwm Technique to Eliminate Harmonics and Power Factor Improvement Using Hybrid Power Filter and By Using Dsp Tms 320lf2407

29 Level H- Bridge VSC for HVDC Application

Compensation for Inverter Nonlinearity Using Trapezoidal Voltage

Switching of Three Phase Cascade Multilevel Inverter Fed Induction Motor Drive

7/15/2002 PP.AFD.08 1 of 28

Power Factor Improvement Using a Three Phase Shunt Active Power Filter

Bhavin Gondaliya 1st Head, Electrical Engineering Department Dr. Subhash Technical Campus, Junagadh, Gujarat (India)

Power Quality Improvement of Unified Power Quality Conditioner Using Reference Signal Generation Method

Three Phase Induction Motor Drive Using Single Phase Inverter and Constant V/F method

Current Control Technique for Three Phase Shunt Active Power Filter by Using Adaptive Hysteresis Current Controller

Synchronous Reference Frame Theory For Nonlinear Loads using Mat-lab Simulink

DESIGN AND DEVELOPMENT OF ACTIVE POWER FILTER FOR HARMONIC MINIMIZATION USING SYNCHRONOUS REFERENCE FRAME (SRF)

Buck-Boost Converter based Voltage Source Inverter using Space Vector Pulse Width Amplitude modulation Jeetesh Gupta 1 K.P.Singh 2

Performance Analysis of SPWM and SVPWM Based Three Phase Voltage source Inverter. K. Latha Shenoy* Dr. C.Gurudas Nayak** Dr. Rajashekar P.

International Journal of Advance Research in Engineering, Science & Technology

High Power Factor Bridgeless SEPIC Rectifier for Drive Applications

Mitigation of Current Harmonics with Combined p-q and Id-IqControl Strategies for Fuzzy Controller Based 3Phase 4Wire Shunt Active Filter

A NOVEL SWITCHING PATTERN OF CASCADED MULTILEVEL INVERTERS FED BLDC DRIVE USING DIFFERENT MODULATION SCHEMES

CHAPTER 4 MULTI-LEVEL INVERTER BASED DVR SYSTEM

Power Quality Analysis in Power System with Non Linear Load

BLDC Motor Speed Control and PFC Using Isolated Zeta Converter

Enhancement of Power Quality using active power filter in a Medium-Voltage Distribution Network switching loads

Transcription:

Analysis of Advanced Techniques to Eliminate Harmonics in AC Drives Amit P. Wankhade 1, Prof. C. Veeresh 2 2 Assistant Professor, MIT mandsour E-mail- amitwankhade03@gmail.com Abstract Variable speed AC drives are finding their place in all types of industrial and commercial loads. This Work covers the current source converter technologies, including pulse width-modulated current-source inverters (CSIs) and in addition, this also addresses the present status of the direct converters & gives an overview of the commonly Used modulation schemes for VFD systems. The proposed work flow is that to work with the simulation of three phases PWM Current Source Inverter fed Induction Motor (CSI-IM) drive systems using Matlab/Simulink simulation Software. This work primarily presents a Unified approach for generating pulse width-modulated patterns for three-phase current-source rectifiers and inverters (CSR/is) that provides unconstrained selective harmonic elimination and fundamental current control. This conversion Process generates harmonics in the motor current waveform. This project deals with the analysis of motor current Harmonics using FFT analysis and use of filter for mitigating them for smooth operation of motor. The filter used for Reduction of harmonics is passive filter. The filter is such it reduces only the 5th & 7th order harmonics. Thus the Analysis of motor current harmonics is done firstly without filter & then it has been compared with the results after the Addition of filter. It is found that the 5th & 7th order harmonics has reduced considerably. Keywords: Harmonics, Total harmonic distortion (THD), variable frequency drives (VFD), power factor, and current Source inverter (CSI), Fast Fourier Transform (FFT). INTRODUCTION The proposed work is based on current source inverter fed induction motor scheme. At the front end a current source Rectifier is connected which converts the 6.6Kv ac voltage into dc by rectifying it. The inverter converts the dc voltage again into ac & then supplies to induction motor. As the switches used in the rectifier & inverter are GTO s & SCR s which requires triggering pulse? The triggering pulse is given by the discrete six pulse generator which is connected to the gate of both rectifier & inverter having six switching devices in each section. Due to the switching processes Harmonics are produced in the system. The output of the inverter which is ac but not sinusoidal due to switching time Taken by the switches & is in quazi square form which is the main cause of harmonics. As six switches are used the Harmonics which are dangerous to the system are 5th & 7th. Thus main focus is to reduce this harmonic order. For doing So low pass filter is to be used so as to reduce this harmonics. An LC filter is used by selecting the values of inductor & Capacitor. Thus it is a passive filter which is used in this scheme. The output of the induction motor is given to the bus - Bar which shows the stator, rotor & mechanical quantities. As our main focus is on current on stator side we choose Stator quantities from bus-bar. A scope is connected to observe the waveforms. METHODOLOGY Adding a variable frequency drive (VFD) to a motor-driven system can offer potential energy savings in a system in Which the loads vary with time. The operating speed of a motor connected to a VFD is varied by changing the Frequency of the motor supply 105

voltage. This allows continuous process speed control. Motor-driven systems are often Designed to handle peak loads that have a safety factor. This often leads to energy inefficiency in systems that operate For extended periods at reduced load. The ability to adjust motor speed enables closer matching of motor output to load And often results in energy savings. The VFD basically consist of a rectifier section which converts the ac supply into Dc, a dc choke which is used to smooth the dc output current & an inverter section which converts dc into ac supply Which is fed to induction motor? The VFD consists of a switching devices such as Diodes, IGBT, GTO, SCR etc.[1] Fig.1: Generalized Variable Frequency Drive A VFD can be divided into two main sections: A. Rectifier stage: A full-wave, solid-state rectifier converts three-phase 50 Hz power from a standard 208, 460, 575 or higher utility supply to either fixed or adjustable DC voltage. B. Inverter stage: Electronic switches power transistors or thyristor switch the rectified dc voltage on and off, And produce a current or voltage waveform at the desired new frequency. The amount of distortion depends On the design of the inverter and filter. III. SYSTEM SIMULATION The proposed work is based on current source inverter fed induction motor scheme. At the front end a current source Rectifier is connected which converts the 6.6Kv ac voltage into dc by rectifying it. For smoothing this voltage before Applying it to inverter a DC choke coil is used this removes the ripples. The inverter converts the dc voltage again into Ac & then supplies to induction motor. As the switches used in the rectifier & inverter are GTO s & SCR s which Requires triggering pulse. The triggering pulse is given by the discrete six pulse generator which is connected to the gate Of both rectifier & inverter. Six switching devices in each section. Due to the switching processes harmonics are Produced in the system. The output of the inverter which is ac but not sinusoidal due to switching time taken by the Switches & is in quazi square form which is the main cause of harmonics. As six switches are used the harmonics Which are dangerous to the system are 5th & 7th. Thus main focus is to reduce this harmonic order. For doing so low pass filter is to be used so as to reduce this harmonics. An LC filter is used by selecting the values of inductor & Capacitor. Thus it is a passive filter which is used in this scheme. The output of the induction motor is given to the bus - Bar which shows the stator, rotor & 106

mechanical quantities. As our main focus is on current on stator side we choose Stator quantities from bus-bar. A scope is connected to observe the waveforms. An FFT block is connected to the motor Current of any one phase whose order of harmonic is to be found out. To this FFT block an FFT spectrum window is connected which displays the order of harmonics from 0 to 19th order of harmonic. Also a bar graph is displayed which shows the order of harmonics which is shown by the FFT spectrum. Thus the work is divided into two sections one before use of filter and after the use of filter. After running the simulation it is observed that the 5th & 7th harmonic components are reduced than that without filter which is shown by the FFT spectrum block. Fig.2: Simulation Diagram of CSI Fed Induction. Table: Induction Motor Specifications Motor Supply Voltage 6600V Horse Power Rating of Motor 200 HP Supply Frequency 50 Hz Stator resistance [Rs], Stator inductance [Ls] 1.485Ω, 0.03027 H Pole Pairs 2 IV.HARMONICS Harmonics are the major problems in any industrial drives. They cause serious problems in the motor which is connected as a load fed from the VFD. The VFD is a current source inverter fed (CSI).At the front end a current source rectifier is connected which converts the 6.6Kv ac voltage into dc by rectifying it. For smoothing this voltage before applying it to inverter a DC choke coil is used this removes the ripples. The inverter converts the dc voltage again into ac & then supplies to induction motor. As the switches used in the rectifier & inverter are GTO s & SCR s which requires triggering pulse. The triggering pulse is given by the discrete six pulse 107

generator which is connected to the gate of both rectifier & inverter. Six switching devices in each section. Due to the switching processes harmonics are produced in the system. The output of the inverter which is ac but not sinusoidal due to switching time taken by the switches & is in quazi square form which is the main cause of harmonics. As six switches are used the harmonics which are dangerous to the system are 5th & 7th. Thus main focus is to reduce this harmonic order. For doing so low pass filter is to be used so as to reduce this harmonics. Total harmonic distortion is the contribution of all the harmonic frequency currents to the fundamental. Table 3.2.1: Harmonics & Multiples of Fundamental Frequencies The nonlinear loads such as AC to DC rectifiers produce distorted waveforms. Harmonics are present in waveforms that are not perfect sine waves due to distortion from nonlinear loads Around the 1830 s a French mathematician named Fourier discovered that a distorted waveform can be represented as a series of sine waves each an integer number multiple of the fundamental frequency and each with a specific magnitude. For example, the 5th harmonic on a system with a 50 Hertz fundamental waveform would have a frequency of 5 times 50 Hertz, or 2500Hertz. These higher order waveforms are called harmonics. The collective sum of the fundamental and each harmonic is called a Fourier series. This series can be viewed as a spectrum analysis where the fundamental frequency and each harmonic component are displayed. [8] Graphically in pu is shown in a bar chart in Figure 3.4.1 Figure 3: Harmonics order in per unit with respect to fundamental From above study it is clear that harmonic currents flow in an AC drive with a 6-pulse front end, let s address what, if any, problems this may cause. Power is only transferred through a distribution line when current is in phase with voltage. This is the very reason for concerns about input power factor. Displacement power factor in a motor running across the line can be explained as the cosine of the phase angle between the current and voltage. Since a motor is an inductive load, current lags voltage by about 30 to 40 degrees when loaded, making the power factor about 0.75 to 0.8 as opposed to about 0.95 for many PWM AC drives? In the case of a resistive load, the power factor would be 1 or unity. In such a case all of the current flowing results in power being transferred. Poor power factor (less than 1 or unity ) means reactive current that does not contribute power is flowing. 108

CONTROL STRATEGIES The induction motor control can be done with the help variable frequency drives. The high power drives can be divided into subparts depending upon the areas of applications. Following chart shows the high frequency drives with different schemes. Figure 4. Chart showing types of VFD schemes Adding a variable frequency drive (VFD) to a motor-driven system can offer potential energy savings in a system in which the loads vary with time. VFDs belong to a group of equipment called adjustable speed drives or variable speed drives. (Variable speed drives can be electrical or mechanical, whereas VFDs are electrical.) The operating speed of a motor connected to a VFD is varied by changing the frequency of the motor supply voltage. This allows continuous process speed control. Motor-driven systems are often designed to handle peak loads that have a safety factor. This often leads to energy inefficiency in systems that operate for extended periods at reduced load. The ability to adjust motor speed enables closer matching of motor output to load and often results in energy savings OVERALL WORKING OF MODEL The proposed work is based on current source inverter fed induction motor scheme. At the front end a current source rectifier is connected which converts the 6.6Kv ac voltage into dc by rectifying it. For smoothing this voltage before applying it to inverter a DC choke coil is used which removes the ripples. The inverter converts the dc voltage again into ac & then supplies to induction motor. As the switches used in the rectifier & inverter are GTO s & SCR s which requires triggering pulse. The triggering pulse is given by the discrete six pulse generator which is connected to the gate of both rectifier & inverter. Six switching devices in each section. Due to the switching processes harmonics are produced in the system. The output of the inverter which is ac but not sinusoidal due to switching time taken by the switches & is in quazi square form which is the main cause of harmonics. As six switches are used the harmonics which are dangerous to the system are 5th & 7th. Thus main focus is to reduce this harmonic order. For doing so low pass filter is to be used so as to reduce this harmonics. An LC filter is used by selecting the values of inductor & capacitor. Thus it is a passive filter which is used in this scheme. The output of the induction motor is given to the bus -bar which shows the stator,rotor & mechanical quantities. As our main focus is on current on stator side we choose stator quantities from bus-bar. A scope is connected to observe the waveforms. An FFT block is connected to the motor current of any one phase whose order of harmonic is to be found out. To this FFT block an FFT spectrum window is connected which displays the order of harmonics from 0 to 19th order of harmonic. Also a bar graph is displayed which shows the order of harmonics which is shown by the FFT spectrum. Thus the work is divided into 109

two sections one before use of filter and after the use of filter. After running the simulation it is observed that the 5th & 7th harmonic components are reduced than that without filter which is shown by the FFT spectrum block. The Total harmonic distortion is also found out by connecting a THD block available in simulink library. It is found that the THD is also reduced after the use of filter. Also a single tuned filter can be used to reduce the harmonics which takes care of only one frequency harmonic component which is to be reduced. The FFT analysis can also be done by using powergui which contains FFT tool. The motor current signal is imported in work space by connecting a simout block to the scope & by selecting structure with time option. Further the proposed work deals with the Wavelet analysis of motor current signal. The Wavelet analysis is performed by two methods. The first one by doing programming in M-file. The program is written so that the motor current without & with filter are compared. The Wavelet analysis uses the time scaling technique. Thus the Low & high frequency components of motor current are compared. It is observed that higher frequency components become zero after filter is used. FFT ANALYSIS OF MOTOR CURRENT The FFT analysis of motor current is done in two steps i.e without filter & after the addition of filter circuit. The output of the induction motor is given to the bus -bar which shows the stator,rotor & mechanical quantities. As our main focus is on current on stator side we choose stator quantities from bus-bar. A scope is connected to observe the waveforms. An FFT block is connected to the motor current of any one phase whose order of harmonic is to be found out. To this FFT block an FFT spectrum window is connected which displays the order of harmonics from 0 to 19th order of harmonic. Also a bar graph is displayed which shows the order of harmonics which is shown by the FFT spectrum. Thus the work is divided into two sections one before use of filter and after the use of filter. After running the simulation it is observed that the 5th & 7th harmonic components are reduced than that without filter which is shown by the FFT spectrum block. The Total harmonic distortion is also found out by connecting a THD block available in simulink library. It is found that the THD is also reduced after the use of filter. Also a single tuned filter can be used to reduce the harmonics which takes care of only one frequency harmonic component which is to be reduced. The FFT analysis can also be done by using powergui which contains FFT tool. Figure 5: Bar-graph showing magnitude of harmonics without filter FFT analysis of motor current with LC filter The FFT analysis of motor current harmonics is done after adding filter An FFT block is connected to the motor current of any one phase whose order of harmonic is to be found out as seen in the diagram. To this FFT block an FFT spectrum window is connected which displays the order of harmonics from 0 to 19th order of harmonic. After the simulation is run the FFT spectrum displays the 110

harmonic orders. As we are using six switches in both current source rectifier & current source inverter we are more concerned with 5th & 7th order harmonic. Also a bar graph is displayed which shows the order of harmonics which is shown by the FFT spectrum. The analysis is done for 5th & 7th harmonic components. The magnitude of this components is 6.19A & 6.18A respectively. Figure 6. Bar-graph showing magnitude of harmonics with filter VII Conclusion The simulation of CSI fed Induction Motor drive caused harmonics in the motor current. This harmonics are the byproduct of switching devices used in rectifier & inverter section. From all the harmonic orders 5th & 7th harmonic cause problem as we use 6 pulse rectifier & Inverter Sections. For the reduction of harmonics we have used LC filter with typical values of inductor & Capacitor. Thus reduction in the 5th & 7th harmonics components is done by passive filter. REFERENCES: 1. K. H. J. Chong and R. D. Klug, High power medium voltage drives, in Proc. Power Con, vol. 1, pp. 658 664. Nov. 21 24, 2004. 2. Bin Wu, S.B.Dewan and G.R.Slemon, PWMCSI Inverter Induction Motor Drives", IEEE Trans. IA, Vol. 28, NO. 1, pp. 64-71,Jan 1992. 3. P. M. Espelage, J. M. Nowak, " Symmetrical GTO current source inverter for wide speed range control of 2300 to 4160 volt, :350 tp 7000hp, induction motors," IEEE IAS Annual Meeting, pp302-307, 1988. 4. M.Salo and H.Tuusa, A vector-controlled PWM current-source-inverter fed induction motor drive with a new stator current control method, IEEE Trans. Ind. Electron., vol. 52, no. 2, pp. 523 531, Apr. 2005. 5. H. Karshenas, H. Kojori, and S. Dewan, Generalized techniques of selective harmonic elimination and current control in current source inverters/ converters, IEEE Trans. Power Electron., vol. 10, pp. 566 573,Sept. 1995. 111

6. B.Wu, G. R. Slemon, and S. B. Dewan, Stability analysis of GTO-CSI induction machine drive using constant rotor frequency control, in Proc. 6th Int. Conf. Elect. Machines and Drives, pp. 576 581,1993. 7. J. Espinoza and G. Joos, On-line generation of gating signals for current source converter topologies, ISIE, pp. 674 678, 1993 112