PHYSICAL FACILITIES Consultant s Handbook Division 08 Openings 7400 Access Control Hardware. Page 1 of 6

Similar documents
Division 08. Openings

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

Victory Fire Door Inspections

DIVISION Hardware

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

.1 Comply with the General Conditions of the Contract, Supplementary General Conditions and the requirements of Division 1.

This section describes the design requirements and materials/products for door hardware.

OWNER S MANUAL STORAGE SHED MODELS: STOR-96-G-W-1RH & STOR-912-G-W-1RH

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

Sound-Tech Xpress Systems The Sound Choice for Acoustical Solutions. Schools/Univ. Commercial/Office. And Much More. Gov./Military

CONCEALED ROD CRASH BAR PR-7085 SERIES EXIT DEVICE ASSEMBLY DETAILS PR mm. 10mm. Lock cylinder. 10mm. Cross bar length (see note #8) Dogging

Infinity 20 Min. FIRE RATED DOORS WARNOCK HERSEY INFINITY - STANDARD RAISED - 20 MIN. RATING SOFTWOOD STILE

2.01 Standard Entrances Description

Installation Instructions for 45HW & 47HW Electrified Mortise Locks

APPENDIX 1H: DOOR HARDWARE 1

ADDENDUM #01. PROJECT: Saint Mary s University Student Centre Reorganization PROJECT N o : DATE:

Encore 20 Min. FIRE RATED DOORS WARNOCK HERSEY ENCORE - STANDARD PANEL - 20 MIN. RATING

LPM Series INSTALLATION INSTRUCTIONS. instructions cover all series from LPM110-LPM WIRE HARNESS (3-PRONG) PM300. LPM Series Includes

1. This Section specifies the ethernet Category 5E data cabling system for buildings and structures.

SD-996C-NUVQ Electric Door Strike with Vertical Adjustment

Installation Instructions

EXIT DEVICE OPERATION FIRE DOOR LABELS, STRIKES AND FRAME SCREWS FOR INFORMATION CALL OR VISIT RITEDOOR.COM

PROJECT LOCATION BOZEMAN HIGH SCHOOL. ELECTRICAL ENGINEER: Van Dykken Engineering 37 Spanish Peak Drive Bozeman, MT Phone:

DIVISION 8 DOORS AND WINDOWS. 1. Exterior and interior single doors shall be 1-3/4 inch thick, 3 feet wide, and 7 feet high, minimum.

Assembly Instructions

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

The following parts list is maintained for the UPI structural components.

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

FIRE RATED DOOR AND FRAME GENERAL REQUIREMENTS

OVERVIEW. Mounting Post (2 places) Cylinder Cam. Handing Pin

Post & Rail Crossbuck

Finish Hardware. Contents. Section 10

A & F Wood Products, Inc 5665 Sterling Drive Howell, Michigan Phone: Fax: Toll Free:

RENOVATION TO STUDENT SERVICES/HOUSING FROM HOSPITAL DAKOTA STATE UNIVERSITY MADISON, SOUTH DAKOTA

SECTION COMMUNICATIONS ELECTRICAL POWER DISTRIBUTION

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

Exit Devices 10 SERIES 1200 SERIES 20 SERIES

INTELLIKEY. Lock Identification GENIUS AT YOUR FINGERTIPS. 1 rev:

2. Skid should contain the following: A door & jamb B casing C seal cover kit & D extension jamb set (if ordered), E hardware box.

Assembly Instructions

10027 S. 51st Street, Ste 102 Phoenix, Arizona (800) Fax:(800)

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

The V2100 Series Steel Raceway provides wiring

ACME 50 Application Guide

SD-996C-NUQ. Universal Door Strike. Manual

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

PUSH BAR EXIT DEVICES CROSS BAR EXIT DEVICES NARROW STILE EXIT DEVICES FEATURING LCWD STRIKES... 20

Soft Suicide Prevention Door & Artwork

1790 Touchbar. Installation Instructions. Rim Panic Device ININST Index:

Tubular Deadbolts. Deadbolt Series HDD Features Ordering String HDD Functions Trim Sets Suggested Specification

HandPunch Installation Guide

HEAVY DUTY 11 STEEL CABINET

STANDARD STALL INSTALLATION DETAIL

IMPORTANT NOTICE WARRANTY WILL BE HONORED ONLY IF THE JAMBS HAVE BEEN INSTALLED IN ACCORDANCE WITH THESE INSTALLATION INSTRUCTIONS

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

ASSA ABLOY. Installation Instructions. MP9800 Series Multi-Point Lock. MP9800 Series Multi-Point Lock Wood Doors. Wood Doors ASSA ABLOY.

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

BEFORE STARTING INSTALLATION

Metal Sound Retardant Door Hardware Information Bulletin

Series D200 Narrow Stile Series D300 Medium Stile * D500 Wide Stile ** Standard Aluminum Swing Entrance Doors

Privacy Wall & Glass Selections Pivot-Hinged Door (For products manufactured after September 14, 2009)

series 9500 top load bi4fold installation instructions

Tubular Latches. 3 a. Heavy Duty Lever Latches Series HLL Features Ordering String Functions Dummy Mounts Trim Sets Specifications

FLUSHLINE ENTRANCES. Features

Solid Core Wood Door / Steel Frame Packages

Congratulations! You are now on your way to enriching your life with! Figure #5. Step 5 Install the Dummy Deadbolt. Step 3 Drill the Door

WD WD7000 Series

Door Hardware Installation Instructions. For Assistance Call:

55 Series. Exit device

Floor Boxes. Concealed Service Floor Boxes. Engineering Data 663 Series. Faces Plates for 663 Floor Box. 663 Series Floor Box

Acoustical Surfaces, Inc.

DHI FALL TECHNICAL. Education COURSE REGISTRATION FORMS FLEXIBLE CONVENIENT AFFORDABLE EMBASSY SUITES SCOTTSDALE, AZ

Design Considera ons & Installa on Guidance

#916 CLASSIC 16 GUN CABINET ASSEMBLY INSTRUCTIONS

Installing Your Electronic Deadbolt

INSTALLATION INSTRUCTIONS CRL JACKSON

Security Products & Services...That Never Sleep. Sur-Lock. I/O 2000L Family of Exit Control Alarm Locks. Installation Instructions

101B, 210X, ELM, VSTB Installation Manual

SECTION FINISH HARDWARE

C-Series & S-Series Classic Frame with Transom (Single or Pair)

June, 2018 Page 1 of 12

Pre-Hanging Information

Round/Octagon Boxes and Accessories

Masonry Frames Interior/Exterior* Drywall Frames Interior**

Installation Instructions for Vista Air Vertically Folding Walls

CLOSED CIRCUIT TELEVISION SYSTEM (CCTV) DOCUMENT NUMBER: APPLICATION: MIDDLE AND HIGH SCHOOL

Versatrac Bypass Door Units, Conventional and Top Track, 300 and 400 Series

INSTALLATION MANUAL. All Recessed Wall-Mount Modules Front-Loading, Rear-Loading, Parcel-Only, Collection Box, Trash/Recycling Bin

19-in. Mini-Rack Cabinet, Type 1

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

STC 42 3-Sided Single Frame (Double Rabbet Only)

SECTION DOOR HARDWARE

Electrical Power Transfer Products

SMARTfit Functional and Brain Fitness Training Multi-Station Trainer Installation for Stud and Concrete Walls (US)

* * 9875/ Customer Service #10-24 # Dogging Key (use to lock down pushbar)

Senior Swing. Caution

Transcription:

1 Definitions Vending Laundry Copy Office/Retail Outlet Door Switch Controlled Door Card Reader Door LX Switch RX Switch Power Transfer Mortise Type Non- consisting of beverage and/or snack machines to be controlled by a card slot mounted on each machine and is controlled by the central system CPU consisting of laundry machines (washers, driers) to be controlled by a card slot mounted on each machine and is controlled by the central system CPU consisting of at least one (1) copy machine controlled by a card slot in same vicinity or on the machine itself and is controlled by the central system CPU Any singe gang RJ-45 type outlet for connection of point of sale device and controlled by central system CPU. (Not a standard PIC) Flush mounted magnetic switch installed at the top of the door frame near the side opposite to the hinges for monitoring of door position Any door consisting of at least (1) door switch, but without a card slot near the controlled door and monitored by the central system CPU. (Referred to as a Point Door) Any door consisting of at least (1) card slot, (1) door switch, (1) electrified piece of door hardware and that is monitored and controlled by the central system CPU Switch located in panic bar mounted on door or inside a mortise type latch to monitor position of the latch Switch located in magnetic lock panic bar mounted on door to monitor position of the panic bar (Request to Exit) Device connected to the door, on hinged side, and to the door frame for the purpose of transferring wires from the door frame to the door for monitoring and controlling the latches Device located in or on door frame, opposite the hinged side of door Electrified Device (Electric Strike) 2 Scope directly across from door latch mechanism 2.1 The work required under this section consists of providing labor and material to install necessary conduit and junction box rough-in s for future access control of doors and for future point of sale control of vending facility, laundry facility, copy facility and office/retail point of sale device. 3 Controlled Door Installations 3.1 Controlled door consists of (1) Hoffman #A- 12N124 box and (1) Hoffman #A-12N12P backplate installed near door. Location of box should not be in front of or above the door. 3.1.1 When the box elevation would be higher than ten feet above finished floor, consider installing the box below the floor or contact the Construction Manager who is responsible to obtain a location that shall be determined by a University representative. 3.2 If door is equipped with ADA Auto Door Opener install ½ EMT from the operator to the 12 x12 x4 Hoffman box. 3.3 New Construction Wooden or Aluminum Doors 3.3.1 From the 12 x12 x4 Hoffman box to each door, (1) ½ EMT shall be installed inside the door frame to a box located at the top of the door frame, opposite of the hinged side for the magnetic door switch. 3.3.2 With Electrified Panic Hardware or Mortise Type Electrified Lock. 3.3.2.1 From the 12 x12 x4 Hoffman door frame, on the hinged side of the door, approximately 6 above the middle hinge for the power transfer. 3.3.3 With Mortise Type Non-Electrified 3.3.3.1 From the 12 x12 x4 Hoffman door frame, opposite the hinged side of the door, directly across from the latch in the door for an electrified door strike. 3.4 Existing Construction Wooden or Aluminum Doors. 3.4.1 From the 12 x12 x4 Hoffman box, Page 1 of 6

Wiremold type #700 shall be either combination connector that is flush to the top of door frame, opposite of the hinge side for magnetic door switch. Only to be used if the door frame is hollow. Installed to a Wiremold #V57242 utility box mounted flush to the top of the door frame opposite to the hinged side with a path into the door frame for magnetic door switch. Only to be used if door frame is hollow. 3.4.2 With Electrified Panic Hardware or Mortise Type Electrified Latch. 3.4.2.1 From the 12 x12 x4 Hoffman #V57242 utility box located near the door frame, on the hinged side of the door, approximately 6 above the middle hinge for the power transfer. 3.4.3 With Mortise Type Non-Electrified 3.4.3.1 From the 12 x12 x4 Hoffman #V57242 utility box located near the door frame, opposite of the hinged side of the door, directly across from the latch in the door for the electrified door strike. 4 Card Reader Door Installations 4.1 Controlled door consists of (1) Hoffman #A- 12N124 box and (1) Hoffman #A-12N12P backplate installed near door. Location of box should not be in front of or above the door. 4.1.1 When the box elevation would be higher than ten feet above finished floor, consider installing the box below the floor or contact the Construction Manager who is responsible to obtain a location that shall be determined by a University representative. 4.2 If door is equipped with ADA Auto Door Opener install ½ EMT from operator to the 12 x12 x4 Hoffman box. 4.3 New Construction Wooden or Aluminum Doors. 4.3.1 Card Reader door consists of flush mounted single gang junction box on latch side of door with (1) ¾ EMT in wall construction to new 12 x 12 x4 Hoffman junction box. 4.3.2 With Electrified Panic Hardware or Mortise Type Electrified Lock 4.3.2.1 From the 12 x12 x4 Hoffman door frame, on the hinged side of the door, approximately 6 above the middle hinge for the power transfer. 4.3.3 With Mortise Type Non-Electrified 4.3.3.1 From the 12 x12 x4 Hoffman door frame, opposite the hinged side of the door, directly across from the latch in the door for an electrified door strike. 4.4 Existing Construction Wooden or Aluminum Doors 4.4.1 Card Reader door consists of a Wiremold #V57242 utility box or Owner supplied card slot back box install on latch side of door. Install Wiremold #700 from box to 12 x 12 x4 Hoffman box. 4.4.2 From the 12 x12 x4 Hoffman box, Wiremold type #700 shall be either combination connector that is flush to the top of door frame, opposite of the hinge side for magnetic door switch. Only to be used if the door frame is hollow. Installed to a Wiremold #V57242 utility box mounted flush to the top of the door frame opposite to the hinged side with a path into the door frame for magnetic door switch. Only to be used if door frame is hollow. 4.4.3 With Electrified Panic Hardware. 4.4.3.1 From the 12 x12 x4 Hoffman #V57242 utility box located near the door frame, on the hinged side of the door, approximately 6 above the middle hinge for the power transfer. 4.4.4 With Mortise Type Electrified Latch. 4.4.4.1 From the 12 x12 x4 Hoffman box, Wiremold type #700 shall be either combination connector that is flush to the door frame. Only to be used if the door frame is hollow. Installed to a Wiremold #V57242 utility box mounted flush to the top of the door frame opposite to the hinged side with a path into the door frame. Only to be used if door frame is hollow. Page 2 of 6

4.4.4.2 From the 12 x12 x4 Hoffman #V57242 utility box located near the door frame, on the hinged side of the door, approximately 6 above the middle hinge for the power transfer. 4.4.5 With Mortise Type Non-Electrified 4.4.5.1 From the 12 x12 x4 Hoffman box, Wiremold type #700 shall be either combination connector that is flush to the door frame. Only to be used if the door frame is hollow. Installed to a Wiremold #V57242 utility box mounted flush to the top of the door frame opposite to the hinged side with a path into the door frame. Only to be used if door frame is hollow. 4.4.5.2 From the 12 x12 x4 Hoffman #V57242 utility box located near the door frame, opposite of the hinged side of the door, directly across from the latch in the door for the electrified door strike. 5 Laundry 5.1 Install 12 x12 x6 Hoffman #A12N126 box, location shall be determined by a University Representative. Vending Vendor is responsible for equipment connect to vending machine. 5.2 Install 4 x4 box behind the laundry machines. This equipment requires (1) 4 x4 box for every 4 laundry machines. Install ¾ EMT from each 4 x 4 box to new 12 x12 x6 Hoffman box. 5.3 Each 4 x4 box shall have ¾ seal-tite flexible conduit installed to each of the four laundry machines. for equipment connection to machine. 6.2.2 Existing Construction Blackboard Vending 6.2.2.1 (1) Wiremold #5747 surface mount box for each machine with (1) Wiremold #700 type raceway to the Hoffman box. 6.2.3 New Construction Blackboard Vending 6.2.4 (1) Single gang flush mount box for each machine with (1) ¾ EMT to the Hoffman box. 7 Copy Reader 7.1 (1) Wiremold #5747 surface mount box or Owner supplied card slot back box mounted on either the copy machine itself or on a box shown on Blackboard details. 7.2 (1) Wiremold #5747 surface mount boxes. First Wiremold #700 type raceway is to be installed from one of the 5747 boxes to discrete location where it can be converted to (1) ¾ EMT continuous from the box to within 18 to 24 from the hallway distribution system. 8 Office/Retail Outlet 8.1 New Construction outlet box shall be a 4 11/16" square flush mounted box. Boxes are to be 2 1/8" deep with single gang, square drawn extension or tile ring. Outlet box shall have (1) ¾ EMT continuous from the box to within 18 to 24 from the hallway distribution system. 6 Vending 6.1 New Vending Machines may utilize wireless credit card technology, therefore eliminating the need for connection to BLACKBOARD. Verify the type of Vending Machines to be utilized. 6.2 Existing Vending Machines still utilizing Blackboard 6.2.1 Install (1) Hoffman # A-12N124 box mounted near the vending machines. Location of Hoffman box shall be determined by a university representative. Vending vender is to be responsible Page 3 of 6

Page 4 of 6

Page 5 of 6

Page 6 of 6