SK Series Pure Sine Wave Inverter. User s Manual

Similar documents
SK Series Pure Sine Wave Inverter User s Manual

SA-150, SA-300 Series Pure Sine Wave Inverter User s Manual

SK200,SK350 Series Pure Sine Wave Inverter User s Manual

Pure sine wave inverter USER S MANUAL

User s Manual Before using the inverter, you need to read and save the safety instructions.

NOVA ELECTRIC A DIVISION OF

TS-700/1000 INVERTER Instruction Manual

SHI Series Pure Sine Wave Inverter (SHI2000 AND SHI3000) User s Manual

Sine Wave Power Inverter GD150/GD300 Series User s Manual

AC MASTER Switch mode sine wave inverter

SR-1600 User s Manual. Telecom / Datacom PURE SINE WAVE INVERTER

SD Series User s Manual SD2500 / SD3500 PURE SINE WAVE INVERTER

Pure Sine Wave Inverter Driver Board Egs002 Eg8010 Ir2110

Operation Manual. Congratulations on purchasing your high quality AIMS Power pure sine inverter!

Freedom HF 1000 Freedom HF Owner s Guide. Freedom HF Inverter/Charger

Freedom HW 1000 Inverter/Charger. Installation Guide

SEC. Technical Manual. SEC America, LLC. Model SFQ1K400 Frequency Converter

INSTALLATION & OPERATION MANUAL

DPA-1200 ORDERCODE D4180 DPA-2400 ORDERCODE D4181 DPA-3400 ORDERCODE D4182

Freedom HF 1000 Freedom HF Owner s Guide. Freedom HF Inverter/Charger

INSTALLATION & OPERATION MANUAL

Owner s Manual 7000 WATTS RMS WATTS RMS COMPETITION D HIGH CLASS D AMPLIFIER HIGH CLASS D AMPLIFIER MADE IN KOREA

SD Series User s Manual SD2500 / SD3500 PURE SINE WAVE INVERTER

ProfiScale MULTI Multimeter

MODEL: Duo Product id:duomk214f Duo OWNER S MANUAL

INSTALLATION & OPERATION MANUAL

AV30MX-2 Operation Manual

CLASS D MONOBLOCK AMPLIFIER DM1500, DM2500 OWNER S MANUAL

M30 SPOT WELDER INSTRUCTION MANUAL 230V 1PH.

R-Series R235LS 2-Channel Power Amplifier with Local Source Switching

INSTRUCTION MANUAL UTL260

AC-DC BATTERY CHARGER 120~230W Portable Battery Charger 300~1000W Stationary Battery Charger

AMPLIFIERS. Bi2200Tx Bi4200Fx. Bi1400Mx Bi2400Mx Bi3000Mx

DPA-1.2. Instruction Manual. 2 Channel Amplifier with Auto A/B Selector DPA-1.2 DPA-1.2 POWER SERIAL # LINE INPUT SENSING SPEAKER B OUT

MODEL 3810/2 Line Impedance Stabilization Network

AC-DC BATTERY CHARGER 120~326W Portable Battery Charger 300~1000W Stationary Battery Charger

CP /240-MC4 User Manual

Amplifier Series BASIC. Installation & Operations Manual

ATBG280/6 Bench Grinder Bench Grinder ATBG280/6 230V-50Hz 280 Watt 150mm x 25mm Wheel size

12V Victor 888 User Manual

PRODUCT SAFETY SOLUTIONS MODEL HWI-01. Model HWI-01 Serial Number:

Explosion Proof Page/Talk Paging Amplifier

Challenger 400. Instruction manual

High Frequency Sinewave Guardian TM Filter

2015 RIGOL TECHNOLOGIES, INC.

MAJORSINE Power Inverter

MODEL W Power Amplifier

AMPLIFIERS BI BI BI BI4400.4

SI-125 Power Amplifier Manual 6205 Kestrel Road; Mississauga, Ontario; Canada; L5T 2A1 November 2016, Rev 0.5

USER'S GUIDE. EcoQuest International 310 T. Elmer Cox Drive Greeneville, TN (423) Setup. Operation. Specifications.

Power-Sure 700. Technical Data TD158001EN. Contents

POWER AMPLIFIER. Owner s Manual Mode d emploi Bedienungsanleitung Manual de instrucciónes CLIP SIGNAL TEMP PROTECTION POWER

DD1-1300S. 500 Watts RMS Watts RMS Watts RMS- 1. Mono-Bloc Digital Power Amplifier

24 VDC, 1000 Watt/ 48 VDC, 2000 Watt Rectifier Installation / Operation Manual

user s manual PLA2170 PLA2270 PLA2370 PLA2470 PLA2570 PLA4170 PLA4270 PLA4370 limited warranty policy Brooklyn, NY 11204

Tel: Fax:

MASS SINE 24/ V

OPERATION & SERVICE MANUAL FOR FC 110 AC POWER SOURCE

CR31. Companion. Instruction Manual

PROAUDIO AMPLIFIERS BI2400PRO BI3400PRO

High Frequency SineWave Guardian TM Filter

INSTRUCTION MANUAL. Type SWF. Sine Wave Filters 690 Volts, 50Hz

CLASS D MONO AMPLIFIER GM-D8601 GM-D9601. Owner s Manual

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

BRIDGEABLE FOUR-CHANNEL POWER AMPLIFIER GM-A6604 GM-A4604. Owner s Manual

Instruction Manual. Manual de instrucciones. Guide d utilisation ET PMET Rev 808

INTRODUCTION FEATURES SPECIFICATIONS. Built-in Crossover

XES-M50 Operating Instructions

Power supply CP-E 24/0.75

TOSHIBA International Corp

Ambient Conditions Storage Conditions Installation Minimum Clearances and Air Flow...2 3

INVERTEC 135S, 150S & 170S

The table below lists the symbols used on the Clamp and/or in this manual. Important Information. See manual.

damage. expiration date. also include a check or money order for $18.00 for return shipping, and R.A. number

ECA COMMERCIAL AMPLIFIER OWNER S MANUAL ECA-70MIXAMP V / 70V / 4Ω Amplifier ECA-70MIXAMP-1-60 OUTPUT LEVEL POWER MASTER MIC 1

15" 500W self-powered subwoofer

IM /2016 REV03 POWERTEC 305S, 365S, 425S, 505S

HOT ROD 500S OPERATOR S MANUAL IM /2016 REV05 ENGLISH

ATS22C21Q soft starter-ats22-control 220V-power 230V(55kW)/ V(110kW)

Dawson DDM190. Digital Multimeter User s Manual

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

INVERTEC V145-S (MANUAL IN ENGLISH) IM /2012 Rev. 7 ENGLISH

SXD SXD SXD SXD Dynamic Audio

IM /2016 REV08 INVERTEC V205, V270 & V405

KX120.2 / KX150.2 / KX200.2

ENCOUNTER AMPLIFIER MANUAL EN-1502 EN-3001 EN-3004

Warnings. Elite Series Waterproof Amplifiers

MASS SINE 12/ V; 24/ V; 12/ V & 120V; 24/ V & 120V

OSCILLATING SPINDLE SANDER

MA6004 MA6002 MARINE AUDIO POWER AMPLIFIER OWNER S MANUAL. The Official Brand of Live Music.

CANARY AUDIO. Power Amplifier CA-309 OWNER S MANUAL. Handcrafted in California MADE IN USA

DSM Dynamic Shunt

BENCH GRINDER OWNER S MANUAL

MUSE : IP+POWER+RS-232 Transmitter

PWM60. PWM Charge Regulator SELECTRONIC PWM CHARGE REGULATOR OUTPUT BATTERY NEGATIVE CHARGE NEGATIVE

DC/AC Inverter/Charger.

200 Watt Passive Shunt Module

THMS WATT WATT PEAK Other Models

INSTALLATION MANUAL ECA-70VMINI-60W ECA-70VMINI-60W L VOLUME SPEAKER OUTPUTS 12VDC IN + L+ L- GND R+ R- S GND GND Tx Rx

AM/FM DUAL ALARM CLOCK RADIO WITH DIGITAL TUNING

Transcription:

SK Series Pure Sine Wave Inverter User s Manual

Table of Contents 1. Important Safety Information. 1 1-1 General Safety Precautions 1 1-2 Battery Precautions.... 1 2. Features... 2 2-1 Application. 2 2-2 Electrical Performance 3~7 2-3 Mechanical Drawings.. 8~9 3. Introduction 10 3-1 Front Panel operation.... 10~13 3-2 Rear Panel operation. 14~15 3-3 Protections Features 15 3-4 Installation. 16 3-5 Making DC Wiring Connections... 17~19 3-6 AC Safety Grounding.. 20 3-7 Inverter Operation 21 4. Troubleshooting guide 22 5. Maintenance 23 6. Warranty.. 23

1 1. Important Safety Instructions WARNING! Before using the Inverter, read and save the safety instructions. 1-1. General Safety Precautions 1-1-1. Do not expose the Inverter to rain, snow, spray, bilge or dust. To reduce risk of hazard, do not cover or obstruct the ventilation openings. Do not install the Inverter in a zero-clearance compartment. Overheating may result. 1-1-2. To avoid a risk of fire and electronic shock, make sure that existing wiring is in good electrical condition and not undersized. Do not operate the Inverter with damaged or substandard Wiring. 1-1-3. There are some components in the inverter can cause arcs and sparks. To prevent from fire or explosion, do not put batteries, flammable materials, or anything should be ignition protected around the inverter. 1-2. Precautions When Working with Batteries 1-2-1. If battery acid contacts skin or clothing, you shall wash it out with soap and water immediately. If battery acid contacts your eyes, you shall wash it out with cold running water for at least 20 minutes and get medical attention immediately. 1-2-2. Never smoke or make a spark or flame in the vicinity of the battery or the engine. 1-2-3. Do not drop a metal tool on the battery. The resulting spark or short-circuit on the battery of other electrical part may cause an explosion. 1-2-4. Remove personal metal items such as rings, bracelets, necklaces, and watches when operating with a lead-acid batteries. Doing so may cause short circuit and very high temperature, which can melt metal items and even burn you. 1

2. Features Pure sine wave output (THD < 3%) Output frequency:50 / 60Hz switch selections Input & output fully isolated design Power Saving Mode to conserve energy High efficiency 89~94% Driving highly reactive & capacitive loads at start moment Tri-Color indicators show input voltage & output load level Loading controlled cooling fan Advanced microprocessor Protection:Input low voltage Overload Short circuit Low battery alarm Input over voltage Over temperature 2-1. Application 2-1-1. Power tools circular saws, drills, grinders, sanders, buffers, weed and hedge trimmers, air compressors, etc. 2-1-2. Office equipment computers, printers, monitors, facsimile machines, scanner, etc. 2-1-3. Household appliances vacuum cleaners, fans, fluorescent and incandescent lights, shavers, sewing machines. 2-1-4. Kitchen appliances coffee makers, blenders, ice markers, toasters, etc. 2-1-5. Industrial equipment metal halide lamp, high pressure sodium lamp, etc. 2-1-6. Home entertainment electronics television, VCRs, video games, stereos, musical instruments, satellite equipment, etc. 2

2-2. Electrical Performance Specification Item Continuous Output Power Maximum Output Power Surge Rating (Max.) Model No. SK700-112 SK700-124 SK700-148 SK700-212 SK700-224 SK700-248 700W 770W 1400W Input voltage 12V 24V 48V 12V 24V 48V Output Voltage 100 / 110 / 120V +/- 5% 220 / 230 / 240V +/- 3% Frequency (Switch Selections) 50 / 60Hz +/- 0.05% Output Waveform Pure Sine Wave ( THD < 3% ) Efficiency (full load) Max. *1 89.0% 91.0% 92.0% 91.0% 93.0% 94.0% No Load Current Draw (Max.) 1.25A 0.64A 0.31A 1.20A 0.60A 0.28A Stand-By Current Draw (Max.) 0.25A 0.15A 0.08A 0.25A 0.15A 0.08A Input Voltage Regulation 10.5-15 21.0-30 42-60 10.5-15 21.0-30 42-60 Input Level Indicator Load Level Indicator Failure Indicator Red / Orange / Green Red LED LED Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over / Under Input Voltage, Over Temperature. Remote Control Unit CR-6 / CR-7 / CR-8 Optional Safety Cert. Meet UL458 EN60950-1 EMC FCC Class A EN55022: 1997 EN55024: 1997 EN61000-3-2: 1998 EN61000-3-3: 1995 e-mark e13 022986 Operating Temperature Range 0-40 Storage Temperature Range -30 to 70 Cooling Dimensions Weight Loading controlled cooling fan 295(L)*180(W)*72(H)mm / 11.61(L)*7.09(W)*2.83(H) Inch 2.7kg / 5.4 Lbs. Note: The specifications are subject to change without notice. 3

Specification Item Continuous Output Power Maximum Output Power Surge Rating (Max) Model No. SK1000-112 SK1000-124 SK1000-148 SK1000-212 SK1000-224 SK1000-248 1000W 1100W 2000W Input voltage 12V 24V 48V 12V 24V 48V Output Voltage 100 / 110 / 120V +/- 5% 220 / 230 / 240V +/- 3% Frequency (Switch Selectable) 50 / 60Hz +/- 0.05% Output Waveform Pure Sine Wave ( THD < 3% ) Efficiency (full load) Max. *1 89.0% 92.0% 93.0% 91.0% 94.0% 95.0% No Load Current Draw (Max.) 1.43A 0.75A 0.38A 1.25A 0.65A 0.35A Stand-By Current Draw (Max.) 0.25A 0.15A 0.09A 0.25A 0.15A 0.09A Input Voltage Regulation 10.5-15 21.0-30 42-60 10.5-15 21.0-30 42-60 Input Level Indicator Load Level Indicator Failure Indicator Red / Orange / Green Red LED LED Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over / Under Input Voltage, Over Temperature. Remote Control Unit CR-6 / CR-7 / CR-8 Optional Safety Certification UL458 EN60950-1 EMC FCC Class A EN55022: 1997 EN55024: 1997 EN61000-3-2: 1998 EN61000-3-3: 1995 e-mark e13 022694 Operating Temperature Range 0-40 Storage Temperature Range -30 to 70 Cooling Dimensions Weight Loading controlled cooling fan 383(L)*182(W)*88(H)mm / 15.08(L)*7.17(W)*3.46(H) Inch 4 kg / 8.8 Lbs. Note: The specifications are subject to change without notice. 4

Specification Item Continuous Output Power Maximum Output Power Surge Rating (Max) Model No. SK1500-112 SK1500-124 SK1500-148 SK1500-212 SK1500-224 SK1500-248 1500W 1650W 3000W Input voltage 12V 24V 48V 12V 24V 48V Output Voltage 100 / 110 / 120V +/- 5% 220 / 230 / 240V +/- 3% Frequency (Switch Selectable) 50 / 60Hz +/- 0.05% Output Waveform Pure Sine Wave ( THD < 3% ) Efficiency (full load) Max. *1 88.0% 91.0% 92.0% 90.0% 93.0% 94.0% No Load Current Draw (Max) 1.45A 0.75A 0.40A 1.40A 0.70A 0.40A Stand-By Current Draw (Max) 0.28A 0.15A 0.09A 0.28A 0.15A 0.09A Input Voltage Regulation 10.5-15 21.0-30 42-60 10.5-15 21.0-30 42-60 Input Level Indicator Load Level Indicator Failure Indicator Red / Orange / Green Red LED LED Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over / Under Input Voltage, Over Temperature. Remote Control Unit CR-6 / CR-7 / CR-8 Optional Safety Certification Meet UL458 EN60950-1 EN55022: 1997 EN55024: 1997 e-mark EMC FCC Class A EN61000-3-2: 1998 e13 22876 EN61000-3-3: 1995 Operating Temperature Range 0-40 Storage Temperature Range -30 to 70 Cooling Dimensions Weight Loading controlled cooling fan 415(L)*191(W)*88(H)mm / 16.34(L)*7.52(W)*3.46(H) Inch 4.8 kg / 10.56 Lbs. Note: The specifications are subject to change without notice. 5

Specification Item Continuous Output Power Maximum Output Power Surge Rating (Max) Model No. SK2000-112 SK2000-124 SK2000-148 SK2000-212 SK2000-224 SK2000-248 2000W 2200W 4000W Input voltage 12V 24V 48V 12V 24V 48V Output Voltage 100 / 110 / 120V +/- 5% 220 / 230 / 240V +/- 3% Frequency (Switch Selectable) 50 / 60Hz +/- 0.05% Output Waveform Pure Sine Wave ( THD < 3% ) Efficiency (full load) Max. *1 89.0% 92.0% 93.0% 91.0% 94.0% 95.0% No Load Current Draw (Max) 2.8A 1.5A 0.7A 2.64A 1.32A 0.65A Stand-By Current Draw (Max) 0.60A 0.30A 0.15A 0.60A 0.25A 0.15A Input Voltage Regulation 10.5-15 21.0-30 42-60 10.5-15 21.0-30 42-60 Input Level Indicator Load Level Indicator Failure Indicator Red / Orange / Green Red LED LED Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over / Under Input Voltage, Over Temperature. Remote Control Unit CR-6 / CR-7 / CR-8 Optional Safety Certification Meet UL458 EN60950-1 EN55022: 1997 EN55024: 1997 e-mark EMC FCC Class A EN61000-3-2: 1998 e13 22846 EN61000-3-3: 1995 Operating Temperature Range 0-40 Storage Temperature Range -30 to 70 Cooling Dimensions Weight Loading controlled cooling fan ( 65 ON, 45 OFF) 422(L)*208(W)*166(H)mm / 16.6(L)*8.18(W)*6.53(H) Inch 9 kg / 19.8 Lbs. Note: The specifications are subject to change without notice. 6

Specification Item Continuous Output Power Maximum Output Power Surge Rating (Max) Model No. SK3000-112 SK3000-124 SK3000-148 SK3000-212 SK3000-224 SK3000-248 3000W 3300W 6000W Input voltage 12V 24V 48V 12V 24V 48V Output Voltage 100 / 110 / 120V +/- 5% 220 / 230 / 240V +/- 3% Frequency (Switch Selectable) 50 / 60Hz +/- 0.05% Output Waveform Pure Sine Wave ( THD < 3% ) Efficiency (full load) Max. *1 88.0% 91.0% 92.0% 90.0% 93.0% 94.0% No Load Current Draw (Max) 3.0A 1.6A 0.8A 2.8A 1.5A 0.7A Stand-By Current Draw (Max) 0.55A 0.35A 0.19A 0.55A 0.35A 0.19A Input Voltage Regulation Input Level Indicator Load Level Indicator 10.5-15 21.0-30 42-60 10.5-15 Red / Orange / Green LED 21.0-30 42-60 Failure Indicator Red LED Protection Overload, Short Circuit, Reverse Polarity (Fuse), Over / Under Input Voltage, Over Temperature. Remote Control Unit CR-6 / CR-7 / CR-8 Optional Safety Cert. Meet UL458 EN60950-1 EN55022: 1997 EN55024: 1997 e-mark EMC FCC Class A EN61000-3-2: 1998 e13 22845 EN61000-3-3: 1995 Operating Temperature Range 0-40 Storage Temperature Range -30 to 70 Cooling Dimensions Weight Loading controlled cooling fan 452(L)*208(W)*166(H)mm / 17.80(L)*8.18(W)*6.53(H) Inch 9.8 kg / 22 Lbs. Note: The specifications are subject to change without notice. *1 : This test condition is normal DC input (13.5V) and Temperature 25 C.

INPUT LEVEL LOAD LEVEL STATUS FREQ. PWR. SAV. O S4 S3 S2 S1 I 2-3. Mechanical Drawings DC INPUT POS(+) NEG(-) REMOTE PORT CHASSIS GROUND REVERSE POLARITY WILL DAMAGE UNIT SK700 273.00 [10.75] SK1000 340.00 [13.39] SK1500 370.00 [14.57] 196.00 [7.72] Pure Sine Wave Power Inverter SK700 151.00[5 94] SK1000 154.00 [6.06] SK1500 163.00[6.42] ON I OFF 0 REMOTE PURE SINE WAVE INVERTER AC OUTPUT 1000W SK700 71.50[2.83] SK1000 88.00[3.46] SK1500 88.00[3.46] SK700 179.00[7.05] SK1000 182.00[7.17] SK1500 191.00[7.52] 8

3000W SK2000 368.00 [14.49] SK3000 398.00 [15.67] 245.00 [9.65] 2000W Pure Sine Wave Power Inverter 177.00 [6.97] 165.25 [6.51] I 0 ON OFF REMO. INPUT LEVEL LOAD LEVEL PURE SINE WAVE INVERTER STATUS S4 FREQ. S3 PWR. S2 S1 SAV. O I AC OUTPUT 209.00 [8.23] 9

3. Introduction This power inverter series is one of the most advanced line of mobile AC power systems. To get the most effective power inverter, it must be installed and used properly. Please read the instructions of this manual before you install and operate this model. 3-1. Front Panel Operations: 3-1-1. Front view: I 0 ON OFF REMOTE PURE SINE WAVE INVERTER INPUT LEVEL LOAD LEVEL STATUS FREQ. PWR. SAV. O S4 S3 S2 S1 I SK700 SK1000 SK1500 AC OUTPUT I 0 ON OFF REMO. PURE SINE WAVE INVERTER SK2000 SK3000 INPUT LEVEL LOAD LEVEL STATUS S4 S3 S2 S1 O I FREQ. PWR. SAV. AC OUTPUT 3-1-2. ON / OFF/ REMOTE (Main) switch: a. Before installing the inverter, you need to ensure the main switch must be OFF. b. Before using the remote unit, you need to ensure the main switch must be REMOTE. 10

3-1-3. Input Level:Display Input Voltages LED Status DC 12V DC 24V DC 48V RED Slow Blink 10.3~10.6 20.5~21.2 40.8~42.4 RED 10.6~11.0 21.2~21.8 42.4~43.5 ORANGE 11.0~12.1 21.8~24.1 43.5~48.1 GREEN 12.1~14.2 24.1~28.6 48.1~56.3 ORANGE Blink 14.2~15.0 28.6~30.0 56.3~59.6 OVER RED Blink 15.0 30.0 59.6 3-1-4. Load Level:Display AC Loads (Watts) LED status DARK GREEN ORANGE RED RED BLINK SK700 0 ~ 56W 56 ~ 230W 230 ~ 525W 525 ~ 672W Over 672W SK1000 0 ~ 80W 80 ~ 330W 330 ~ 750W 750 ~ 960W Over 960W SK1500 0 ~ 120W 120 ~ 495W 495 ~ 1125W 1125 ~ 1450W Over 1450W SK2000 0 ~ 160W 160 ~ 660W 660 ~ 1500W 1500 ~ 1920W Over 1920W SK3000 0 ~ 240W 240 ~ 990W 990 ~ 2250W 2250 ~ 2880W Over 2880W 3-1-5. AC Frequency:Selected by S4 Dip Switch Frequency S4 50 HZ OFF 60 HZ ON 11

3-1-6. Status:Display Power & Fault Status Green LED LED Signal Status Solid Slow Blink Power OK Power Saving Red LED LED Signal Status Fast Blink OVP Slow Blink UVP Intermittent Blink OTP Solid OLP 3-1-7. Power Saving Mode: Power Saving Mode is adjustable and SK700 set by the Dip Switches, S1, S2 and S3 on the front panel. Example: With the watt setting at 15W, a 15W load will make the inverter operate normally, a 15W load will enter into the Power saving mode. SK1000 SK1500 SK2000 SK3000 S1 S2 S3 DISABLE DISABLE DISABLE OFF OFF OFF 15W 20W 40W ON OFF OFF 25W 40W 80W OFF ON OFF 40W 55W 125W ON ON OFF 50W 75W 170W OFF OFF ON 65W 95W 210W ON OFF ON 75W 115W 245W OFF ON ON 85W 135W 280W ON ON ON 12

3-1-8. AC outlets (available): North America (GFCI) NEMA 5-20R NEMA 5-15R Continental European Australia / New Zealand United Kingldom Universal IEC-1 IEC-2 HARD WIRE 13

3-2. Rear Panel Operations: DC INPUT REMOTE PORT POS(+) NEG(-) SK700 SK1000 SK1500 CHASSIS GROUND REVERSE POLARITY WILL DAMAGE UNIT SK2000 SK3000 3-2-1. Remote Port: The SK Series Inverter is compatible with any of the remote controllers, CR-6, CR-7 or CR-8. Before using the remote unit, you need to ensure the main switch is in the REMOTE position and the input voltage of the power inverter is the same as it of the remote unit. 3-2-2. Fan Ventilation: Be sure to keep it a distance (at least 1 inch) form surrounding things. 14

3-2-3. DC Input Terminal: Connect DC input terminal to 12V / 24V / 48V battery or the other power sources. + represents positive, and - represents negative. Reverse polarity connection will blow the internal fuse and may damage the inverter permanently. Model Minimum DC Input Voltage Maximum 12 V 10.5 15.0 24 V 21.0 30.0 48 V 42.0 60.0 3-2-4. Use wire # 8 AWG to connect Chassis ground with vehicle chassis. WARNING! Operating the inverter without a proper ground Connection may cause an electrical hazard. 3-3. Protections Features: Model Over Voltage Restart DC Input () Under Voltage Alarm Under Voltage Shutdown Shutdown Shutdown Restart Over Temperature Protection INTERIOR Restart Shutdown HEAT SINK Restart 12 V 15.3 14.3 11.0 10.2 12.7 24 V 30.6 28.8 22.0 20.3 25.2 70 45 90 60 48V 61.0 58.1 44.0 40.8 49.7 15

3-4. Installation: The power inverter should be installed in an environment that meets the following requirements: 3-4-1. Dry Do not allow water to drip on or enter into the inverter. 3-4-2. Cool Ambient air temperature should be between 0 and 40, the cooler the better. 3-4-3. Safe Do not install the inverter in a battery compartment or other areas where flammable fumes may exist, such as fuel storage areas or engine compartments. 3-4-4. Ventilated Keep the inverter a distance (as least 1 inch) away from surrounding things. Ensure the ventilation shafts on the rear and the bottom of the unit are not obstructed. 3-4-5. Dust Do not install the Inverter in a dusty environments The dust can be inhaled into the unit when the cooling fan is working. 3-4-6. Close to batteries Avoid excessive cable lengths. Do not install the Inverter in the same compartment as batteries. Use the recommended wire lengths and sizes (see section 3-5). Do not mount the Inverter where it will be exposed to the gases produced by the battery. These gases are very corrosive, and prolonged exposure will damage the Inverter. WARNING! Shock Hazard. Before proceeding further, carefully check that the Inverter is NOT connected to any batteries, and that all wiring is disconnected from any electrical sources. Do not connect the output terminals of the Inverter to an incoming AC source. 16

3-5. DC Wiring Connections: Follow this procedure to connect the battery cables to the DC input terminals of the Inverter. The cables should be as short as possible (less than 10 feet / 3 meters ideally) and large enough to handle the required current in accordance with the electrical codes or regulations applicable to the installation. Cables that are not an adequate gauge (too narrow) or too long will deteriorate inverter performance such as poor surge capability and frequent low-input voltage warnings and shutdowns. These low input voltage warnings are due to DC voltage drop across the cables from the inverter to the batteries. The longer and narrower the cables, the greater the voltage drop. Increasing DC cable size helps improve the situation. COTEK recommends the following cables for optimum inverter performance. (Apply both 120V and 230V versions ) Model No Wire AWG Inline Fuse SK700-112 / 212 # 4 100 A SK700-124 / 224 # 6 50 A SK700-148 / 248 # 8 30 A SK1000-112 / 212 # 2 150 A SK1000-124 / 224 # 4 80 A SK1000-148 / 248 # 6 40 A SK1500-112 / 212 # 2 200 A SK1500-124 / 224 # 4 100 A SK1500-148 / 248 # 6 50 A SK2000-112 / 212 # 2/0 250 A SK2000-124 / 224 # 1/0 125 A SK2000-148 / 248 # 2 70 A SK3000-112 / 212 # 4/0 400 A SK3000-124 / 224 # 2/0 200 A SK3000-148 / 248 # 1/0 100 A 17

3-5-1. Connect the cables to the power input terminals on the rear panel of the inverter. The red terminal is represents positive (+) and black terminal represents negative (-). Insert the cables into the terminals and tighten the screw to clamp the wires securely. WARNING! Ensure all the DC connections are tight (torque to 9 10 ft-lbs, 11.7 13 Nm). Loose connections may cause overheat and fire. WARNING! The installation of a fuse must be on a positive cable. Failure to place a fuse on + cables running between the inverter and battery may cause damage to the inverter and will void warranty. Also, use only high quality copper wire and keep cable length short, a maximum of 3-6 feet. Battery to inverter cable connection AWG#2 - #6 Do not place anything between battery cable lug and terminal surface. Assemble exactly as shown. 18

REVERSE POLARITY WILL DAMAGE UNIT USER SERVICEABLE PARTS INSIDE. PORT REMOTE PORT CHASSIS GROUND SK1000 SK1500 DC INPUT POS(+) NEG(-) REMOTE CHASSIS GROUND INLINE FUSE SK2000 SK3000 Battery to inverter cable connection DC INPUT POS(+) WARNING: NEG(-) SHOCK HAZARD. DO NOT OPEN. NO SPRING WASHER INLINE FUSE PVC WIRE Do not place anything between battery cable lug and terminal surface. Assemble exactly as shown. 19

3-6. AC Safety Grounding: The AC output ground wire should go to the grounding point for your loads ( for example, a distribution panel ground bus ). 3-6-1. Neutral Grounding (GFCI S): 3-6-1-1. 120V models:the neutral conductor of the AC output circuit of the Inverter is automatically connected to the safety ground during inverter operation. This conforms to National Electrical Code requirements that separately derived from AC sources (such as inverters and generators) which have their neutral conductors tied to ground in the same way as the neutral conductors from the utility tied to ground at the AC breaker panel. For models configured with a transfer relay, while AC utility power is present and the Inverter is in bypass mode, this connection (the neutral of the Inverter s AC output to input safety ground) is not present so that the utility neutral is only connected to ground at your breaker panel, as required. Ground Fault Circuit Interrupters (GFCI): Installations in Recreational Vehicles (for North American approvals) will require GFCI protection of all branch circuit connected to the AC output of the hardwire terminal equipped with Inverter. In addition, electrical codes require GFCI protection of certain receptacles in residential installations. While the pure sine wave output of the Inverter is equivalent to the waveform provided by utilities, compliance with UL standards requires us to test and recommend specific GFCI. Cotek has tested the following GFCI protected 20A receptacles and found that they functioned properly when connected to the output of the Inverter. 20

3-7. Inverter Operation: To operate the power inverter, use the ON / OFF switch on the Front panel to turn the power on. Then the power inverter is ready to deliver AC power to your loads. If there is several loads use, turn them on separately after the inverter is ON in order to prevent OVP resulted from the surge power. 3-7-1. Set the power switch to ON position and the buzzer will send out Beep sounds at the moment. Then the inverter will make selfdiagnosis, and the LED s indicators will also appear various colors. Finally the buzzer will Beep again and the Input Level and Status LED indicators will turn to Green color, then the inverter starts to work successfully. 3-7-2. Set the power switch to the OFF position, then the inverter stops and all the lights go Off. 3-7-3. Set the power inverter switch to ON position and turn the test load On. The inverter should supply power to the load. If you plan to accurately measure the true output r.m.s. voltage of the inverter, a meter such as FLUKE 45 BECKMAN 4410 or TRIPLETT 4200 must be used. 21

4. Troubleshooting: WARNING! Do not open or disassemble the Inverter. Attempting to service the unit yourself may cause the risk of electrical shock or fire. Problems and Symptoms Possible Cause Solutions No AC Power Output STATUS illuminates the red LED a. Blinking fast Over input voltage. ( OVP ) b. Blinking slowly. Low input voltage. ( UVP ) Check input voltage. Reduce input voltage. Recharge battery. Check connections and the cable. c. Blinking Intermittently. Thermal shutdown. ( OTP ) d. Solid ON. Short circuit or Wiring error. Overload.(OLP) Improve ventilation. Make sure ventilation shafts in the inverter are not obstructed. Lower ambient temperature. Check AC wiring for short circuit. Reduce the load. 22

5. Maintenance: To keep your inverter operating properly, there is very little maintenance required. You should clean the exterior periodically with a damp cloth to prevent accumulation of dust and dirt. At the same time, tighten the screws on the DC input terminals. 6. Warranty: We guarantee this product against defects in materials and workmanship for a period of 24 months from the date of purchase and will repair or replace any defective power inverters if you directly returned them to us with postage paid. Please note that Cotek is only responsible for ensuring our products are operational before delivering. This warranty will be considered void if the unit has been misused, altered, or accidentally damaged. Cotek is not liable for anything that occurs as a result of the user s fault. 23

No. 33, Rong Hsin Rd., Pa Teh City, Tao Yuan County, Taiwan Phone:886-3-3661581 FAX:886-3-3676029 E-mail:sales@cotek.com.tw http:// www.cotek.com.tw 2007.06A