RF Remote Control Unit SEAV

Similar documents
200, 201 Series Radio Telemetry Transmitters

118, 128, KEELOQ REMOTE CONTROL SYSTEMS, 12 / 24Vdc,

PRO Professional Radio Control Series Applications

Modular Radio Telemetry System

Operating Instructions

Lazerpoint TM RF RX-91 Basic Receiver Installation Instructions

PROFLY / PROBLADE Professional Radio Control PRO-BLADE8

Modular Radio Telemetry System

FIREFLY FIREBLADE RADIO REMOTE CONTROL SYSTEMS. Applications

COD GB / 1.0 RBAND/UMS - RBAND/CSM

SPA WIRELESS SWITCHES AND RECEIVERS MANUAL

RADIOBAND V3 Programming & Installation Manual

SABRETrap Control. Description

Installation & Operation Manual SAGA1-K Series Industrial Radio Remote Control

eguard EG2233, EG3333, EG3355, EG3388 & EG8406: Installation and Set-up Procedures Tx 2200 and Rx 4200 Boards

Radio Control Installation and Operating Instructions System 4

IMPULSES RADIO TRANSMISSION SYSTEM HL 630

Technical Description. DCF77 Receiver-Module 4460

Sesam. Robust radio remote control for industrial and mobile applications ROBUST SWEDISH DESIGN SINCE 1918

Installation instructions

English RACON SERIES II RADIO CONTROL SERVICE MANUAL

Blue Point Engineering Inc.

User Guide for Pager RX900-LED

WSA 8 BOX RELE Installation Manual

INDEX 1 - PRODUCT FEATURES

ET RXTX-RC Weatherproof Repeater Version 2011/010. Specifications. Encryption: Rolling Code. Frequency: MHz

Specification for Lightning Sensor

Pulse Scaler for DIN Rail Attachment

DatasheetDirect.com. Visit to get your free datasheets. This datasheet has been downloaded by

FMR ELSEMA 2-Channel 151MHz Receiver - FMR15102

FCC ID: SAGA1-L8 IC: 2802A-SAGAL8 CE0470

ENCODING PHOTOCELLS MF6

WEL-200 O P E R A T I N G I N S T R U C T I O N S W I R E L E S S E D G E L I N K

GLR43308 and GLR2708. Setup and programming instructions. for the 8 channel Gigalink receiver. Programming Videos

VIPER Remote Control Systems

AC2000 AMPLIFIER PLATFORM

Tele Radio T70 Jaguar

Receiver Type /Version Factory No. Frequency. Transmitter Type /Version Factory No. Frequency

OPERATING MANUAL SESAM 800 MOBILE TAIL LIFT EN -D0

INMOTION Controls Series INSTALLATION & OPERATION MANUAL. INMOTION Series - INMOTION INMOTION-260. Page: 1/15

Blue Point Engineering

HORNET Remote Control Systems

Tele Radio T60. Manual. Rev. IM-T A4

TONE ALERT RECEIVER MODEL 2TR9A. P.O. Box West Pacific. Lexington, NE 68850

OPERATING MANUAL SESAM 800 MOBILE TAIL LIFT C0

IRIS \ IRIS-I QUICK SET-UP GUIDE STEP 1 INSTALL

USERS GUIDE EAGLE SMR MOTION SENSOR

FMR ELSEMA 1-Channel 151MHz Receiver - FMR15101

Installation Instructions

CCR24T CCR24R. User s Guide WIRELESS TRANSMITTER SYSTEM WARRANTY SERVICE CARD WARRANTY CARD

Instruction. Actuator ICAD 600 / ICAD 900 / ICAD 1200 ICAD 600 ICAD 900 ICAD 1200 ICAD 600 ICAD 900. ICAD 1200 Fig. 2. Fig. 4

Accessories for Actuators

DR-TRC105-EV Evaluation Kit. User s Guide

AT-SL-ADR & AT-SL-ADR/SA

WPR400 Wireless Portable Reader

Radio receivers type DB317 and DBR1-M4

Photoelectrics Amplifier, µ-processor Controlled Type PAM, 2-10 Inputs/2-10 Transistor Outputs

WARRANTY. Long Range Systems, LLC, 20 Canal St, Suite 4N, Franklin, NH 03235

Radio receiver E17 2-channel, 27 MHz, 40MHz, or 433 MHz, 2 relay outputs. Operating voltage: 230 V/AC or 12 V or 24 V AC/DC available.

Operating manual. Radio remote V.5. a Look Solutions 1 product

9RCT4334 Four Button. 2 3/4 X 1 3/8 X 9/16 (70mm x 35mm x 14mm) 2 3/4 x 2 1/8 x 1 (70mm x 55mm x 25mm)

SA-505 Supervised Wireless Multi-Layer Repeater Installation Manual 1. General Description

Lewmar 3 & 5 Button Wireless Remote Control Issue 1

Warnings Valid for relay receivers with the following references: ARF7341B/7341F/7341D and serial receivers ARF7263K/S

TWINDRIVE TD32. Data sheet LINAK.COM/HOMELINE

TABLE OF CONTENTS. Keypad Programming Manual 1

INSTALLATION MANUAL. REMOTUS JUPITER Era 4/6/8B

User Manual. ProRF Encoder Transmitter & Receiver

MLR-1105 (DC battery type door chime receiver) LMLT-711 (push unit door chime transmitter)

AT-SL-DDR & AT-SL-DDR-SA

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15108 (No Case version)

The system (EF-7700) consists out of two parts: the transmitter (EF-7602) and the receiver including wiring (EF-7701).

Parts. Backplate. Battery Cover. Backup Key. Touchscreen Assembly. Inside Assembly. Thumbturn. Strike. Reinforcement Plate. Bolt.

TRC EV DR TRC EV DR TRC EV

Digital Electronic Thermostat With RF

EC5401B. B-Tronic EasyControl. Assembly and Operating Instructions. Wall/hand-held transmitter, 1-channel, bidirectional

CAME QP- V4.4 SPECIFICATION STANDARDS CABLE PLAN CABLE TYPES Z SERIES AUDIOCODE CONTROL SET FOR DOUBLE LEAF GATES

Frequency Coverage MHz RF Power Output 30W SSB / 9W AM/ 30W FM Dual Finals on Heat Sink Modes AM, FM, USB, LSB Microprocessor

AT-SL-DDR & AT-SL-DDR-SA

G703. Installation instructions. residential gate opener for sliding gates. remote control openers security at your fingertips

CordLift WireFree Programming & Operation Instructions CT-32RT-12V

USERS MANUAL TR-710.

AMERITRON RCS-12 AUTOMATIC ANTENNA SWITCH

FMT15101E, FMT15102E, FMT15104E, FMT15108E (Enclosed version) FMT15101, FMT15102, FMT15104, FMT15108 (No Case version)

FA401 Single Transmitter / Single Output Receiver. FA401R Single Transmitter / Single Relay Output Receiver. Installation Instructions 02305C

BandMaster V Manual. Installation

Wireless multizone receiver RDE-MZ6

Hub and Cluster. ogramming Manual. Pro MAN3090

SF C-Series. 900 MHz Wireless Switch Follower/Remote Control Receiver (with On-Board 10-Amp Relays) Typical Applications

IMPORTANT: READ AND UNDERSTAND ALL INSTRUCTIONS BEFORE BEGINNING INSTALLATION

Wireless Pulse Transmitter and Receiver System. Ideal for slumpstand wireless metering application

ECM3 EARTH CONTINUITY RELAY

IMPORTANT! Please take the time to read through the manual before you start to install/program your equipment.

Blue Point Engineering Inc.

First of all, power up the handsets and controllers!

Manufacturing Access Control since For more information, please visit or call toll free at

Mounting Instruction. Compact Mini EGC Amplifier and Application

VELA-RX MOTORE 220V 500W

K580M GUIDA ALL INSTALLAZIONE INSTALLATION GUIDE INSTALLATIONSANLEITUNG NOTICE D INSTALLATION GUÍA PARA LA INSTALACIÓN

# Made In USA. Simple GPS Tracker Parts List. Needed Tools and Materials

Transcription:

RF Remote Control Unit SEAV for LINAK TECH-systems Installation instructions

Foreword Dear producer, Thank you for choosing an actuator system from LINAK. LINAK systems consist of high-tech products based on many years' experience of manufacturing and developing actuators, electrical control boxes, control systems and chargers. This Instruction Manual explains how to install and set an RF Remote Control Unit of type SEAV for a TECH-system. Before our products leave the factory, they are subject to a full battery of function and quality tests. In the unlikely event that you experience problems with your systems, please contact LINAK Danmark A/S on (+45) 86803611. LINAK provides a guarantee for all of its products and systems. However, this guarantee is subject to the condition that the product is used in accordance with the specifications, that maintenance is performed correctly, and that any repairs are carried out at a workshop that is authorised to repair LINAK products. Any alterations to the installation and use of LINAK systems may affect their operability and durability. The products may not be opened by unauthorised persons. LINAK Danmark A/S Mønstedsvej 9 DK-8600 Silkeborg Page 2 of 10 oct. 2017 ver. 02.

Table of contents. Foreword... 2 Table of contents.... 3 Technical data... 4 Description of the system... 4 Dimensions... 4 Installation... 5 Installing the receiver:... 5 Connection... 6 Set relay function (SW1)... 6 Connecting receiver RXS 2224... 7 CB8-A / CB8-T / CB9 / CB12... 7 TR-EM-208... 9 TR-EM-239... 9 TR-EM-288... 9 Coding transmitter (control unit) TXS2... 10 Pairing transmitter and receiver... 10 Reset factory settings... 10 Page 3 of 10 oct. 2017 ver. 02.

Technical data Technical data The SEAV receiver and transmitter system comprises a two-channel transmitter and receiver: Transmitter: Model description: TXS 2 Power supply, alkaline battery: 12 VDC (23A) Transmission frequency: 433.92 Mhz Combinations: 1024 (12-bit code) Max. consumption: 25 ma Operating temperature: -20...+70 C Receiver: Model description: RXS 2224 Supply: 12/24 V AC/DC Max. consumption: 5 W Receiver frequency: 433.92 Mhz Circuit: 30 VDC Operating temperature: -20...+70 C Range: 50 100 m Ingress Protection rating: IP 54 Description of the system The SEAV receiver and transmitter system is intended for use in a TECH actuator solution to facilitate remote control of the system. The system uses radio frequencies to communicate between transmitter and receiver. Dimensions Receiver; RXS 2224 82 55 45 Page 4 of 10 oct. 2017 ver. 02.

Transmitter; TXS 2 Installation To achieve optimal conditions for communication between transmitter and receiver, it is important to choose transmitter location with care. Range is determined not solely by the technical specifications of the units in question. The range may therefore vary depending on radio-electrical conditions at the installation site. Installing the receiver: To remove receiver cover, unscrew screw C. Then, using the 3 screw holes (labelled A), mount the transmitter with three suitable screws. Page 5 of 10 oct. 2017 ver. 02.

Connection. SW1 Set relay function J1 Jumper to select power supply voltage 12 V DC/AC LED for channel 2 (CH2) LED for channel 1 (CH1) SEL button Push button to select channel to code the transmitter 24 V DC/AC Terminal 1: Supply +12/24 V DC/AC Terminal 2: Supply 0V Terminal 3: Output channel 1 Terminal 4: Output channel 1 Terminal 5: Output channel 2 Terminal 6: Output channel 2 Set relay function (SW1) Monostable function = Active while the transmitter button is pressed and held. Remote-controlled SEL button = Monostable function can be used to code new transmitter. 120 sec. delay circuit = Active for 120 sec. after the button is released. Bistable function = changeover relay function. Page 6 of 10 oct. 2017 ver. 02.

Connecting receiver RXS 2224 The receiver must be connected in accordance with the connection diagrams (see below) for the following LINAK control boxes and third-party controllers LINAK control boxes: CB8-A CB8-T CB9 CB12 Third-party controllers: TR-EM-208 TR-EM-239 TR-EM-288 LINAK control boxes: CB8-A / CB8-T / CB9 / CB12 The above-mentioned LINAK control boxes use a DIN connector for control. You can order a cable with DIN connectors for use between control box and receiver from LINAK Danmark A/S. Article no. 0015751 Page 7 of 10 oct. 2017 ver. 02.

Page 8 of 10 oct. 2017 ver. 02.

Third-party controllers TR-EM-208 TR-EM-239 TR-EM-288 Page 9 of 10 oct. 2017 ver. 02.

Coding transmitter (control unit) TXS2 Transmitters for use in the system must be coded individually. Each transmitter must have its own code, which can be changed by moving the positions of the 10 switches so that the pattern on each transmitter is different. Pairing transmitter and receiver To pair the respective transmitters to the receiver: Press SEL button once. LED for CH1 flashes. Then press button 1 on the transmitter (control unit). Constant light in LED for CH1 when pairing is completed. Press twice on the SEL button to repeat same procedure for CH2. NB! Disconnect the receiver's antenna before pairing transmitters (control units). LED for channel 2 (CH2) LED for channel 1 (CH1) SEL button Push button to select channel to code transmitter Reset factory settings To delete all codes recorded in the receiver, press and hold the SEL button for 5 sec. When the unit is reset, the LEDs for CH1 and CH2 respectively will flash 3 times. Page 10 of 10 oct. 2017 ver. 02.