User s Manual. F2 Calculator. A metering component for thermal energy applications

Similar documents
SVM F2 Calculator. A small competent calculator for compact or wall montage. Users manual

SVM F22. Calculator for heating or cooling applications. Data sheet

SVM F27 Compact. Ultrasonic heatmeter. Data sheet

SVM F27 Compact. Compact heat meter. Users manual

SVM F27 / C27. Ultrasonic BTU meter for heating or cooling. Data sheet

SVM F22 SVM F27. Calculator for heating or cooling applications. Ultraljudsmätare. Installation Guide. Datablad

Brunata Optuna H. Properties. Counter

SONOMETER TM 1100 Ultrasonic compact energy meter

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

Brunata Optuna H Ultrasonic energy meter Type 775 Installation Guide Edition 1.2

SonoMeter 31 Energy Meters

SONOMETER TM 1100 Ultrasonic compact energy meter

INFOCAL 8 Energy calculator

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approved according EN 1434 and MID in class 2 with dynamic range of 1:250 (qi:qp) in class 2

SHARKY 775 ULTRASONIC COMPACT METER. 4 Approval with dynamic range up to 1:250 (qi:qp) MID in class 2 (depends on meter size), standard 1:100

Supercal 531 Multi function Integrator that lives up to Your highest expectations

Infocal 9 Energy calculator

3 PHASE ENERGY ELECTRONIC METERS MKT & MKT2. (Code to ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.

1.2 M-Bus (optional) The M-Bus is a galvanically isolated interface for the transmission of meter data (absolute values).

6000 W, 2450 MHz Microwave Generator GMP 60K SM 56T400 FST 3 IR

SUPPLY NETWORK ANALYZER. CVMk SERIES. CVMk-4C SERIES INSTRUCTION MANUAL. ( M / 00 B - Manual 1 / 2 ) (c) CIRCUTOR S.A.

ENCORE 300 SERIES INSTALLATION AND OPERATING INSTRUCTIONS

Eltek TU GenII GD900A Energy monitor (multidrop NDRail350) transmitter user instructions

RAY MECHANICAL COMPACT METER. 4 MID approved class 2 from ND 15 mm qp 0,6 m3/h up to ND 40 mm qp 10 m3/h

ULTRASONIC D. Compact ultrasonic heat meter

ENA33LCD. Power line analyzer. User and service manual. Obrezija 5 SI-1411 Izlake

RAY COMPACT ENERGY METER MECHANICAL

12/2 Product overview. 12/3 7KT1 14, 7KT1 53 E-counters. 12/9 7KT1 11, 7KT1 12 digital measuring devices. 12/11 7KT1 0 analog measuring devices

USER MANUAL ENGLISH 1450 COIN COUNTER & SORTER

SONOMETER TM 1000 Ultrasonic compact heat meter

R PROFLAME Instruction Book Collection

Electronic Heating Energy Meters

INSTALLATION & OPERATION MANUAL

MULTICAL Energy meter TS PTB. Application

SonoSelect 10 and SonoSafe 10 Energy Meters

Installation & User Manual Radio Remote RCS-10E

SULTANATE OF OMAN METERING AND DATA EXCHANGE CODE

RAY MC COMPACT ENERGY METER MECHANICAL

PREMIER INSTALLATION AND OPERATING INSTRUCTIONS

PLA 33. Power line analyzer. User and service manual. version 2.4

Micromate User Manual

Heat meter Q heat 5 US

Dial-type digital bar graph. LEDs for Open Collector, Relays and Warning Indicator

Signet 9900 Transmitter

impact VC-500LR Monolight INSTRUCTIONS

MULTICAL 601 DATA SHEET

Installation & Operation Manual

FLOMID-MX Control unit for electromagnetic flowmeters USERS MANUAL. instrumentación para fluidos. Realitzat: Revisat R+D Electrònic: Aprovat: Data:

A1000 ALPHA and A1200 ALPHA Meter Installation Instructions. General. Installation. For A1000 ALPHA Type R, A1000 ALPHA Type C, and A1200 ALPHA Meters

M1 Series. Humidity - Temperature Transmitter INSTRUCTION MANUAL

Aqua-Gen 3BR INSTRUCTIONS

Instruction. INFOCAL 8 Energy calculator. 1.0 Table of contents. 2.0 Safety notes and product information

MultiCube Multi-Function Electricity Meter. Installation and Operation

ME162 Single-Phase Electronic Meter

Siemens Switzerland Ltd HVAC Products. SIEMECA Electronic Heat and Cooling Meters

Instruction. SONOMETER 1100 Ultrasonic compact energy meter. 1.0 Table of contents. 2.0 Safety notes and product information

Contents. Introduction and description Package contents Device identification PM Options... 80

Power-meters three-phase

Signet 9900 Transmitter

WIRELESS Energy Monitor - Smart Meter

MULTICAL 602 DATA SHEET

INTRODUCING SOME GREAT NEW PRODUCTS FROM OUR DWYER INSTRUMENTS RANGE:

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

SONOMETER 2000 Ultrasonic heat meter

3-phase meter with direct connection and pulse or Modbus RS485 output

Operating manual IMPORTANT! READ CAREFULLY BEFORE USE. KEEP FOR THE ENTIRE LIFE OF THE PRODUCT. Heat meters. Deltamess TKS-WM compact heat meter

SolarEdge Export Limitation Application Note

MA7200 PLUS INVERTER SERIES PID Quick Start Manual For Fan and Pump Applications

I n s t a l l a t i o n M a n u a l. T E D P r o L i t e A B C. f o r. Shop for The Energy Detective products online at: Rev 3.

Temperature Controller model MFC-301/T-Dry. Version for Dry Transformers and Motors. Technical Manual. Licht

RI-F200 Series. Single and Three Phase Multifunction Energy Meter. Telephone : +44 (0) Displayed Parameters

Technical Information

1: Introduction : Caution : Tips for Reading this Manual : Preface : System Highlights : Receiver

RI-D440. Three Phase easywire Multifunction DIN Rail Energy Meter. Telephone : +44 (0) Displayed Parameters

Signet 9900 Transmitter

Operating Guide October 2006

Keyed latch. Cover. Service Outlet 115VAC, 15A. Plastic base. Unpack. Operator. the Operator

Dual T/C & RTD Calibrator With Auto Stepping

Laboratory Grade Instruments Series & 4021 Power Meter SERIES Power Sensor

Signet 9900 Transmitter

INSTALLATION & PROGRAMMING MANUAL PROGRAMMABLE TIMER (MODEL LP-2)

RAY MC COMPACT ENERGY METER MECHANICAL

GIMA Multi-Function Electricity Meter OPERATOR S MANUAL

Single phase meter with direct connection and pulse or Modbus RS485 output

ultego III smart plus

TROVIS 5500 Automation System TROVIS 5578 Heating and District Heating Controller. Mounting and Operating Instructions EB 5578 EN

Installation & User Manual Radio Remote RCS 20E

Aqua-Gen 3PV INSTRUCTIONS

HEAT CALCULATOR MODEL 212

DIGEM f 96 x 48 EK. Applications. Description

Energate Foundation Meter Data Collector Installation Guide

HDU-SF (Horizontal Distribution Units - Single Flat)

Centrale de mesure Power Meter PM500 Merlin Gerin

MULTICAL 602. Data sheet. Heat and cooling meters with unlimited communication

ND 510 ND 550 Y Z SPEC FCT MOD

FIELD MOUNTED RATE TOTALISER MODEL 202D

Instruction Manual. The AquaSun 3RP is a premium automatic solar controller with temperature adjustment, manual, winter mode features.

INSTALLATION MANUAL FOR RADIO CONTROL SESAM 6099 TRANSMITTER

Measurement. SITRANS F US Inline. 3/262 Siemens FI Transmitter SITRANS FUS080/FUE080

Energy Management Energy Meter Type EM21 72R Retro-Fit

Transcription:

User s Manual F2 Calculator A metering component for thermal energy applications Rev 08.24.2007

1 Installation 1.1 At delivery F2 calculators are delivered in the Transport Mode. Only the clock is active and no measurements can take place in this mode. The Transport Mode is indicated by a "no" in the upper left hand corner of the display screen. Before beginning installation, the meter needs to be set to operating mode. To move the F2 out of transport mode, simply press and hold the display button for approximately five seconds. Depending on the factory settings of the calculator, it will then enter either Service Mode, or go directly into Operation Mode. You can tell which mode the calculator has entered by looking at the upper left hand portion of the display window no will have been replaced by 00 when entered into Service Mode, or 10 if entered into Operation Mode. If your calculator goes into Service mode, please refer to section 4 for further details. Fig. 1.1a, Transport Mode Note: In order to complete the installation the F2 must be set to Operation Mode.

1.2 Connections The screw terminal blocks are located under the plastic cover on the rear side of the calculator. Note: a seal protects the cover s retaining screws. Fig. 1, Connection terminal F2 3V Kt 0 F F R R P1 0 P2 A A1 B1 MBus MBus 9 11 5 6 7 8 16 17/19 18 50 60 61 24 25 This Calculator is equppped with pulse outputs Fig. 6, Labels on the on the backside of the F2 cover. Numbering according to EN1434 Terminal Block Marking Description 9 3V Flow sensor power supply (+) 10 Kt Flow sensor (+) 11 0 Flow sensor (-) 5 F High temperature sensor (H) 6 F High temperature sensor (H) 7 R Low temperature sensor (L) 8 R Low temperature sensor (L) 16 P1 Pulse input/output 1 (+) 17/19 0 Pulse input/output 1 and 2 (-) 18 P2 Pulse input/output 2 (+) 60 A1 Siox input (option) 61 B1 Siox input (option) 24 MBUS M-Bus input 25 MBUS M-Bus input 4

2 Mounting The F2 can be mounted either on a wall, or on the flow meter itself. 2.1 Mounting on a flow sensor The adapter allows the calculator to be mounted vertically or horizontally, see fig 2.1. Attach the calculator to the adapter with the provided retaining screw. 1. Screw for attaching the adapter 2. Guide rails 3. Adapter 2.2 Wiring 2 1 Fig. 2.2 Fig 2.1 The F2 has six holes for connecting cables. To ensure proper sealing, it is vital that the diameters of cables are of the following gauges: 1. Flow sensor and temperature sensor: 16-18 gauge. 2. Spare (communication) 16-18 gauge. 1. 2. 3. 2.3 Dimensions All dimensions are in [mm]. Fig. 2.3b, Wall Adapter 5

2.4 Installation test When installation has been completed, a simple test can be done to verify that the calculator has been installed correctly. Watch the very lower left hand corner of the main display. If the flow sensor is supplying a pulse, it will result in a blinking square. If the F2 is receiving a pulse from the flow meter, then installation has been a success. Now is also a good time to become familiar with recognizing and cycling through the display sequences provided by the F2. Simply press and hold the Display button on the front of the calculator. 2.5 Instantaneous values Calculations for instantaneous power (display sequence 20 ) and instantaneous flow (display sequence 21 ) follow these rules: As long as the time between the flow sensor pulses is longer than five seconds, flow and power are calculated and displayed for each flow sensor pulse. When the time between pulses is less than five seconds, the pulses are added together for approximately five seconds and then displayed. 6

3 Handling 3.1 Display Every F2 is equipped with an LCD (Liquid Crystal Display). The data retrieved by the calculator is organized and accessible through display sequences visible on the LCD. The left-most digits indicate the current selected sequence. The right-hand digits show the relevant value for the currently selected sequence. A tap of the display button results in a move to the next value in the your current sequence. To change to a new sequence, press and hold the Display button until the left-hand digits starts to increment. Release the button at the desired sequence. The right-hand digits will now display the values and readings related to your newly selected sequence. If you wish to return the display to the original sequence, simply do not press the display button for ~60 seconds. The display is configured as below: 1. Sequence digits 2. Flow sensor pulse indicator 3. Relevant value shown here, maximum 7 digits 4. Arrow that indicates unit for displayed value m³ C m³/h kw F2 Made in Sweden Nr: 000433 OPTO interface Display button HOLD 10 11 xx 16 20 xx xx PUSH 70 xx Fig. 3.6.1.1, Tap to toggle to next value. Press and hold to enter next sequence.

3.2 Display sequence table 10 Accumulated energy (Default position) 11 Accumulated volume according to flow sensor 1 12 Display test, see fig.3.2 13 Accumulated volume for pulse input 1 14 Accumulated volume for pulse input 2 15 Error code, see Error code 16 Error time, [Minutes] 20 Momentary power 21 Momentary flow 22 High temperature, 0 decimals 23 Low temperature, 0 decimals 24 Temperature difference, 1 decimal 30 Account days, when values are stored, [YYMMDD] 31 Account days, Accumulated energy 32 Account days, Accumulated volume according to flow sensor 33 Account days, Accumulated volume according to energy calculation 34 Account days, Accumulated volume pulse input 1, [gal] 35 Account days, Accumulated volume pulse input 2, [gal] 36 Possible error code, at time of storage of account days 37 Possible accumulated error time, at the time of storage account days, [Minutes] 40 Monthly registers, date when values are stored, [YYMMDD] 41 Monthly registers, Accumulated energy 42 Monthly registers, Accumulated volume according to flow sensor 43 Monthly registers, Accumulated volume according to energy calculation 44 Monthly registers, Accumulated volume pulse input 1, [m3] 45 Monthly registers, Accumulated volume pulse input 2, [m3] 46 Possible error code, at time of storage of monthly register 47 Possible accumulated error time, at the time of storage, [Minutes] 4x Following monthly registers (loop back) 50 Operating time, [Hours] 51 Relevant date, [YYMMDD] 52 Relevant time, [HH.MM] 53 Recommended date for battery replacement, [YYMMDD] 60 Communication address, Primary address A0 Communication address, Secondary address (normally same as meter S/N) bx Calculator serial number (S/N) 63 Pulse value [l/p] 64 Placing of flow sensor, [H/L], L = Low, H = High 70 Accumulated volume corresponding to accumulated energy 73 Last remote reading of accumulated energy 74 Time since latest remote reading of accumulated energy, [Hours] 75 Accumulated total error time, [Minutes] 1 The calculator has two values for accumulated volume. Sequence 11 is calculated relative to flow pulses. Value 70 is incremented in conjunction with energy calculation. 8

Error codes Error codes are shown in display sequence 15. Code Description 0001 Break in low temperature sensor (L) 0002 Short circuit in low temperature sensor (L) 0004 Break in high temperature sensor (H) 0008 Short circuit in high temperature sensor (H) 0005 Error code combination 0001 + 0004 000A Error code combination 0002 + 0008 0040 Low flow 0100 Battery replacement recommended Display sequence 15 - error codes 9

4 Service Note: Do not attempt to change any values until you have read and understand all sections of this manual. If you have any questions, please contact TCT before attempting to access or alter any values in this mode. After installing the F2, please bypass this mode by skipping through to the exit sequence as shown below in table 4.1 As mentioned in section 1, most calculators will enter the Service Mode upon installation and exit of the Transport Mode. The Service Mode allows for changes to certain parameters of the calculator. If you wish to re-enter the Service Mode, use the following steps: 1. Break the seal to the Service button (fig 3.2) on the rear side of the calculator with a small screwdriver. 2. Press and hold down the Display button on the front of the calculator. 3. While holding the Display button pressed, use the screwdriver to press and hold the Service button. 4. Keep the Service button and Display button pressed for ~5 seconds. 5. First release the Display button, then release the Service button. The calculator is now in the Service mode, and the display will show 00 in the upper left-hand corner as confirmation. To leave the Service mode follows the same procedure described above. Navigating through the Service sequence and changing values This is similar to cycling through the F2 s main LCD sequences as discussed in section 3. Tapping the Display button alters the value for the blinking digit. To change to the next digit, hold the Display button pressed until next digit starts to blink. To change to the Service sequence hold, the Display button pressed until next service sequence is reached (indicated by the left-hand digits). Note: The changed values are not saved until the next sequence is displayed. Service Sequences 2.1.0 Time 00 is the real time clock, with the right hand digits representing the format HHMM. 2.2.1 Date 01 the relevant date in the format YYMMDD 2.2.2 Pulse value 02 and 03 indicate pulse values. 02 is the sequence for the pulse value itself and 03 denotes the number of decimals applied for the pulse value. Example 1 The pulse value shall be 2.5 [l/p]. 02 shall be 2500, and 03 shall be 3. E.g. 2500 with 3 decimals = 2.5 [l/p]. Example 2 The pulse value shall be 10 [l/p]. 02 = 1000, 03 = 2. E.g. 10 [l/p]. 2.2.3 Account days 04 and 05 are account days with the format MMDD. F2 calculators can store up to two. To deactivate the account days set MMDD to 0000. For most applications, this sequence can be skipped.

2.2.4 Communication address 06 is the communication address. The address is set with four digits. Skip this sequence unless intending to implement a remote reading device, such as Mcomm. 2.2.5 Flow sensor placing 08 sets flow sensor placing, format 0 or 1. 0 = Flow sensor installed in low (cold) 1 = Flow sensor installed in high (hot) 2.2.6 Reset the accumulated error time 07 is the reset value for accumulated error time. Format 0 or 1. 0 = Reset error time 1 = Do not reset error time 2.2.7 Recommended date for battery replacement 09 sets the battery replacement date, format YYMMDD. 2.2.A Exit service mode 0A allows you to exit the service mode depending on which value is set: 0 = Return to sequence 00 1 = Exit Service Sequence 4.1 Service sequence table Service sequence Description 00 Time [hhmm] 01 Date [YYYMMDD] 02 Pulse value for flow meter, without decimal placing, 4 digits 03 Pulse value decimal placing, 0-4 04 Account days 1, MMDD 05 Account days 2, MMDD 06 Primary communication address, set with 3 digits, e.g. 5 is set 005. 07 Reset stored error time 0 = Reset stored error time (default) 1 = Do not reset error time 08 Flow sensor placing, 0 = Installed at low end (L / cold) 1 = Installed at high end (H / hot) 09 Recommended battery replacement date. Do not change without consulting with TCT Solar. 0A Exit service sequence, 1 = EXIT 2 = return to service sequence 00 Table 4.1, Service sequence, Servic e Test Save data Fig. 3.2a, Service button Service button 12

5 Seals 1. Service seal 2. Test seal 3. Electronic seals 4. Installation seals 1 SV SV SV SV SV 3 4 13

6 Technical data 6.1 Power supply Battery 3V 2.2Ah Maximum operation time: 10 yrs Table 7.1, Power supply 6.2 Temperature sensors Approved and matching pairs of temperature sensors of the type Pt 100 or Pt 500 are to be used, with a maximum current of 4 A for PT100. Cable area [gauge] Maximum cable length for PT100 sensors [ft] 24 8.2 20 16.4 18 24.6 15 49.2 Table 7.2, Cable areas for PT100 6.3 Flow sensors Flow sensor with pulse output. Max. frequency [Hz] 12 Pulse value range [l/p] 0.0001-9999 Min. pulse length [ms] 40 Max. voltage [V] 3 Max. cable length [ft] 49.2 Table 7.2, Technical specifications 6.4 Temperature range Temperature range 0-374 F Temperature difference 2 120K Table 7.4, Temperature range 6.5 Ambient temperature & temperature class F2 complies with the prerequisites for Environmental Class C according to EN1434. Ambient temperature storage/transport -4 F to 158 F Ambient temperature operation 41 F to 131 F Table 7.5, Ambient temperature ranges

6.6 Flow sensor placing F2 can be configured for flow sensor placement in high or low end of the pipe (supply or return pipe). This is marked H = high (hot) or L = low (cold) in display sequence 64. 6.7 Maximum values for power The values below represent MWh and standard decimal setting Pulse value [l/p] Maximum power [ MW ] 1.0 3.3 10.0 33.0 100.0 330.0 2.5 3.3 25.0 33.0 250.0 330.0 Table 7.7, maximum power displays relative to pulse values 6.8 Dynamic behavior Instantaneous measurements are calculated for each flow sensor pulse, when the time between the pulses is five (5) seconds or longer. If the time between pulses is less than five seconds, measurements takes place every pulse and are added for 5 seconds. When the period between the flow sensor pulses exceeds 60 seconds, a measurement takes place every 60th second. For this kind of measurement, only the temperature is updated. 6.9 Data output interface M-Bus acc. to EN1434-3 Via OPTO-interface (EN60870-5) bus connection (terminals) Table 7.9, data output interfaces 16

6.10 Pulse outputs F2 can be equipped with two pulse outputs for Energy (pulse output 1) and Volumetric values (pulse output 2). The last digit and unit of energy will determine pulse weight. Example: sequence 10 (energy) on display is shown 1001.01 MWh => pulse weight = 0.01 MWh/pulse. Pulse output 1 Energy - one pulse per display update in the energy register (sequence 10 ). Pulse output 2 Volume - one pulse per display update in the flow register (sequence 11 ). Pulse value [ms] 250 Voltage [V] 3 30 Maximum current [µa] 20 Table 7.10, Pulse output data 6.11 Pulse inputs Standard F2s are equipped with two pulse inputs. The pulse inputs can be used for measuring another meter equipped with pulse outputs. The pulse inputs can be set as volume registers. These registers accumulate the pulses into two volume registers with the value [gal]. Frequency [Hz] 12 Min. pulse duration [ms] 40 Max. Voltage [V] 3 Table 7.11, Pulse inputs +3V 6.12 Alarm output The F2 is equipped with one alarm output. The alarm output sends a pulse every hour as long as an error code exists. The pulse duration 250 [ms] can be altered using the Service program version 2 or higher in 125 [ms] increments. Alarm frequency when an Once every hour error exists Pulse [ms] 250 17

7 Appendix Displayed values on the F2 calculator will vary depending on the set pulse value, and follow the diagram below. Smaller pulse values result in readings to more decimal places than larger pulse values. 7.1 Decimal placing F2 The decimal setting for F2 follows utility standards. Pulse value [l/p] MWh GJ m³ KWh MBTU kw m³/h 1.0 0.001 0.001 0.001 0.1 0.001 0.01 0.001 10 0.01 0.01 0.01 1 0.01 0.1 0.01 100 0.1 0.1 0.1-0.1 1 0.1 1000 1 1 1-1 1 1 2.5 0.001 0.01 0.01 0.1 0.01 0.01 0.001 25 0.01 0.1 0.1 1 0.1 0.1 0.01 250 0.1 1 1-1 1 0.1 2500 1 1 1-1 1 1 Table A1 7.1.1 Decimal placing Pulse value [l/p] m³ 1.0 0.001 10 0.01 100 0.1 1000 1 2.5 0.01 25 0.1 250 1 2500 1

7.2 Ordering Key F2 ABCDEFGHIJ KLM A 1 Pt100 2-wire measurement, flow in low temperature A 2 Pt100 2-wire measurement, flow in high temperature A 5 Pt500 2-wire measurement, flow in low temperature A 6 Pt500 2-wire measurement, flow in high temperature B 1 Battery supply B 2 Bus supply B 5 24 VAC C 0 Kt Input 2.5 l/p C 1 Kt Input 25 l/p C 2 Kt Input 250 l/p C 3 Kt Input 2500 l/p C 4 Kt Input 1 l/p C 5 Kt Input 10 l/p C 6 Kt Input 100 l/p C 7 Kt Input 1000 l/p C 8 KWh D A MWh C B GJ C C MBTU D 0 Standard order D 1 Special, Extra information at the order, e.g. customer information D 2 Pulse Inputs, 2.5 l/p, dec. 2 D 3 Pulse Inputs, 25 l/p, dec. 1 E - Pulse Inputs, 250 l/p, dec. 0 E S Pulse Inputs, 1 l/p, dec. 3 F 1 Pulse Inputs, 10 l/p, dec. 2 F 2 Pulse Inputs, 100 l/p, dec. 1 F 3 Pulse Inputs, 1000 l/p, dec. 0 F 5 Pulse Outputs F 6 Backlight on display (not recommended on battery supplied meters) F 7 No Backlight F 8 For wall mounting, with adapter incl. F 9 Compact mounted with Hydrometer BR431 G 0 Compact mounted with other flow sensor, with adapter incl. G 1 With adapter for BR471 G 4 With out adapter G 5 Standard H 0 Standard H 1 Country code, 3 = Standard English H 2 Standard H 3 Standard H 4 Pt100 2-wire measurement, flow in low temperature I - Pt100 2-wire measurement, flow in high temperature J 1 Pt500 2-wire measurement, flow in low temperature K 1 Pt500 2-wire measurement, flow in high temperature L 0 Battery supply M 0 Bus supply 19

101 Copeland Street Jacksonville, Florida 32204 Phone: 904.358.3720 Fax: 904.358.3728 www.tctsolar.com info@tctsolar.com