Two- and three-phase MagneX interrupter

Similar documents
Figure 1. Two- and Three-phase MagneX Interrupter.

VariSTAR Type AZU heavy-duty distribution-class under-oil MOV surge arrester

Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

35 kv Class M.O.V.E. DirectConnect elbow arrester

Eaton s Cooper Power Series DEADFRONT ARRESTERS

VariSTAR Type AZL heavy-duty distribution-class MOV arrester

Comparison of recloser and breaker standards

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

POSI-BREAK Metal Oxide Varistor Elbow (M.O.V.E.) Surge Arrester

Distribution/Substation Transformer

Distribution Transformers

Effective February 2017 Supersedes January 2012 (CP1122)

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

Three-Phase VFI Padmount Transformers. Double Duty in a Single Package. www. ElectricalPartManuals. com

WESTERN UNDERGROUND COMMITTEE GUIDE 2.6 (2.6/00/0868)

COOPER POWER SERIES. External application of a motor start capacitor on a single-phase voltage regulator. Voltage Regulators MN225063EN

MV ELECTRICAL TRANSMISSION DESIGN AND CONSTRUCTION STANDARD. PART 1: GENERAL 1.01 Transformer

How to maximize reliability using an alternative distribution system for critical loads

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Transformer Protection

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

Mica Element Support High Current Interruption Element. Welded Element Joints

COOPER POWER. UltraSIL Polymer-Housed VariSTAR Type U2Surge Arrester for Systems through 275 kv IEC 10-kA; Line Discharge Class 2 SERIES

Series NRX with PXR - Instructions for Neutral Current Sensor Type NF

Power-Sure 700. Technical Data TD158001EN. Contents

Protection of Electrical Networks. Christophe Prévé

TABLE OF CONTENT

Course 11 Distribution Transformer Applications Instructor: David R. Smith, PE Due: April 24, 2017 (EV), April 25, 2017 (LC)

This document covers common questions concerning the design of an effectively grounded system.

NOVA-TS Triple-Single Recloser and Form 5/TS Control Frequently Asked Questions

Howard Smart Transformer Specification Guide

Short-Circuit Current Calculations

Variable Transformers Product Design & Engineering Data

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

Table of Contents. Introduction... 1

UltraSIL Polymer-Housed Evolution Distribution Class Surge Arrester Certified Test Report

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Electrical Description

BUCK-BOOST TRANSFORMERS

S. C. Electric Cooperative s Specification for a Single-Phase, Single Bushing Overhead Distribution Transformer (Revised 10/2013)

Protective Relays Digitrip 3000

Article 225: Outside Branch Circuits And Feeders

SECTION 5 TRANSFORMERS

Three-phase pad-mounted compartmental type transformer

GENERATOR INTERCONNECTION APPLICATION Category 5 For All Projects with Aggregate Generator Output of More Than 2 MW

Section 2 Outdoor Voltage Transformers

E N G I N E E R I N G M A N U A L

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Single-Phase Mini Pad-Mounted Transformer Specification: Energy+ MPDL

Unit 29 Three-Phase Transformers

Certificate of Compliance

Transformer Protection Principles

UltraSIL Polymer-Housed VariSTAR Normal-Duty, Heavy-Duty and Riser Pole Distribution-Class Arresters

Busbars and lines are important elements

R Distribution Transformers. Mineral Oil-Immersed, Self-Cooled, 60 Hertz Voltages and Connections. Reference Data

Description & Applications Questions & Answers Selection Charts Single Phase Selection Charts Three Phase...

TRANSMISSION ENGINEERING STANDARD TES-P , Rev. 0 TABLE OF CONTENTS 1.0 SCOPE 2.0 BONDING METHODS

ARC FLASH PPE GUIDELINES FOR INDUSTRIAL POWER SYSTEMS

HPS Universal BUCK-BOOST TRANSFORMERS

7. INSPECTION AND TEST PROCEDURES

No. SSIEC-SEW SHINSUNG. Solid Insulation Eco Load Break Switch (SILO) SILO SERIES 15kV, 27kV 400A, 630A

Training Fees 3,300$ per participant including Materials/Handouts, Tea/Coffee Refreshments & International Buffet Lunch.

PACSystems* RX3i IC695MDL765

PJM Manual 07:: PJM Protection Standards Revision: 2 Effective Date: July 1, 2016

Warehouse Stock Transformers

Protective Relaying for DER

Are snubbers required with Eaton s Cooper Power series liquid-filled hardened transformers?

NORTH CAROLINA INTERCONNECTION REQUEST. Utility: Designated Contact Person: Address: Telephone Number: Address:

R10. IV B.Tech I Semester Regular/Supplementary Examinations, Nov/Dec SWITCH GEAR AND PROTECTION. (Electrical and Electronics Engineering)

BE1-67N GROUND DIRECTIONAL OVERCURRENT RELAY FEATURES ADDITIONAL INFORMATION. FUNCTIONS AND FEATURES Pages 2-4. APPLICATIONS Page 2

Surge Arresters. VariSTAR Type AZS Normal Duty Distribution Class MOV Arrester

NERC Protection Coordination Webinar Series June 9, Phil Tatro Jon Gardell

Catalog 200 Contactors up to 115 A Motor Starters up to 55 kw 03/2009

Issued: September 2, 2014 Effective: October 3, 2014 WN U-60 Attachment C to Schedule 152, Page 1 PUGET SOUND ENERGY

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

INTERIM ARRANGEMENTS FOR GRID TIED DISTRIBUTED ENERGY RESOURCES. Technical Requirements for Grid-Tied DERs

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

POWER FACTOR CORRECTION. HARMONIC FILTERING. MEDIUM AND HIGH VOLTAGE SOLUTIONS.

Effective November 2017 Supersedes May 2017

BC145 SIGNAL ISOLATOR BOARD

Supplemental Motor Protection Devices Specifications

National Marine Manufacturers Association Compliance Specialist Examination A.C. Electrical (2018 Model Year) ABYC E-11 Supplement 56

Tertiary Winding Design in wye-wye Connected Transformers Restricted Siemens Energy 2013 All rights reserved.

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

IDAHO PURPA GENERATOR INTERCONNECTION REQUEST (Application Form)

ET 51 - Electrician Theory Examination Marking Schedule

AMENDMENT NO. 1 SEPTEMBER IS (Part 1) : 2001/IEC (1991) SURGE ARRESTORS

Section L5: PRE-ENERGIZATION TEST PROCEDURES FOR LOAD-ONLY ENTITIES AND TRANSMISSION-ONLY ENTITIES

Supplemental Motor Protection Devices Specifications

GENERATOR INTERCONNECTION APPLICATION Category 3 For All Projects with Aggregate Generator Output of More Than 150 kw but Less Than or Equal to 550 kw

ELECTRICAL POWER TRANSMISSION TRAINER

Grounding Recommendations for On Site Power Systems

NEO TELE-TRONIX PVT. LTD. 6/7 Bijoygarh, Kolkata , Tel : ; Fax :

SECTION LOW VOLTAGE ACTIVE HARMONIC FILTER SYSTEM NEMA 1 ENCLOSED

The Isolator/Surge Protector (ISP)

PRE COMMISSIONING TESTS ON EQUIPMENT AT 33/11 KV SUB STATIONS. IR Values are to be read on the megger by meggering the Power transformer

The Isolator/Surge Protector (ISP)

OPERATING, METERING AND EQUIPMENT PROTECTION REQUIREMENTS FOR PARALLEL OPERATION OF LARGE-SIZE GENERATING FACILITIES GREATER THAN 25,000 KILOWATTS

Arc Sensor User Manual

SECTION LOW-VOLTAGE ELECT. DIST. DESIGN AND CONSTRUCTION STANDARDS _ February 2015 PART I: GENERAL

Transcription:

Fusing Equipment Catalog Data CA132017EN Supersedes 2-33 July 2011 COOPER POWER SERIES Two- and three-phase MagneX interrupter General Eaton protects distribution transformers from damaging overloads and secondary faults with its Cooper Power series MagneX interrupter, an overcurrent protective device, also used for switching the transformer on or off. As a transformer protective device, the MagneX interrupter combines safety and efficiency with economic operation. It is an integral assembly, which does not use a troublesome linkage or require calibration, making installation and operation fast and trouble free. The housing is made of an ultraviolet stabilized, high-strength, glass-filled thermoplastic material. The operating shaft is sealed against leakage with a double-viton O-ring seal. Application The three-phase MagneX interrupter combines the functionality of three Bay-O-Net fuses and one three-phase on/off loadbreak switch into one protective device. This allows transformer manufacturers more flexibility in application of the product and potentially reduces the space required to install the device on the transformer front plate. This product is ideal for three-phase pad-mounted transformer applications. The two-phase MagneX interrupter is designed for single-phase applications where disconnecting both primary coil leads is desirable. This feature is ideal for two-bushing transformers, where a fault on either leg of the transformer may cause activation of the protective device. Secondary faults and overloads will trip the MagneX interrupter open. However, the device can be reset once the condition is corrected. The MagneX interrupter, in coordination with either an isolation link or current-limiting fuse, also clears primary faults. The MagneX interrupter can also be used as a primary switch to disconnect the transformer windings not just the load. This eliminates core (no-load) losses on transformers not in service. Residual voltage problems associated with secondary breakers during banking of transformers are also eliminated.

Catalog Data CA132017EN Two- and three-phase MagneX interrupter Electrical ratings Table 1. Voltage Ratings and Characteristics kv Amps Impulse 1.2 x Microsecond Wave 1 60 Hz, 1 Minute Voltage Withstand Continuous Current Rating 42 Switching Load Currents 42 Table 2. Interrupting Rating Voltage kv-lg (A) RMS Symmetric (A) 8.3 20 4200 15.5 10 22 23.0 0 7 RMS Asymmetric (A) Interrupter Chambers Ganged Trip Figure 1. Three-phase MagneX interrupter, single-phase sense, single-phase trip. Three-phase MagneX interrupter operation Figure 1 demonstrates the circuit diagram for the three-phase MagneX interrupter with single-phase sense, single-phase trip. The three-phase MagneX interrupter with single-phase sense, single-phase trip contains one sensors per phase. It reacts to fault currents on one phase and will cause tripping of that phase only. The MagneX interrupter then can be reset via the single operating handle by opening all three phases and closing all phases back in simultaneously. Figure 2 demonstrates the circuit diagram for the three-phase MagneX interrupter with single-phase sense, three-phase trip, containing one sensor in two of the three phases. This product should only be applied to delta-connected primary transformers, where any fault current flow in one phase will also flow in an adjacent phase. It reacts to fault currents on one phase and will cause tripping of all three phases. The MagneX interrupter then can be reset via the single operating handle by opening all three phases and closing all phases back in simultaneously. The three-phase MagneX interrupter with single-phase sense, threephase trip should always be used in series with at least one backup current-limiting fuse in each of the three-phases. The backup current limiting fuses (see ELSP catalog section CA132013EN) provide high-current interruption capability. Figure 3 shows the circuit diagram for the two-phase MagneX interrupter. The two-phase MagneX interrupter was specifically designed for single-phase, two bushing transformers, where disconnection of both bushings is desired following fault/overload detection. The MagneX interrupter will react to a fault sensed in either leg of the transformer primary. Interruption takes place in both interruption chambers simultaneously, disconnecting both legs of the transformer from the circuit. Interrupter Chambers Figure 2. Three-phase MagneX interrupter, single-phase sense three-phase trip. Interrupter Chambers Ganged Trip Ganged Trip Figure 3. Two-phase MagneX interrupter. 2

Two- and three-phase MagneX interrupter Catalog Data CA132017EN Optional handle assemblies A standard handle, as shown in Figures 5, is typically used in overhead pole-type transformers. It is also used in underground pad-mounted transformer applications. The MagneX interrupter handle is reversible to enhance functionality and provide for optimal orientation of the handle in pad-mounted transformer applications. It is made of an ultraviolet stabilized high-strength, glass-filled thermoplastic material. The lower slotted portion of the handle is made of a flexible ultraviolet stabilized elastomeric material. The handle requires five pounds (2.27 kg) of force to operate manually. It allows flexibility for excessive force during operation. 2.25 (57 mm) 1.125 (28.5 mm) 0.156 rad. (4 mm) Figure 6. Tank mounting hole detail. Note: Exterior mounting surface extending 1 / 2 outward from the tank hole outer edge shall be flat and clear of surface obstructions. Figure 4. Open/Closed handle positions (Standard positions shown). Figure 5. MagneX interrupter assembly front/side/back views (with standard handle hardware kit). NNote: Dimensions given are for reference only, inches (mm) 3

Catalog Data CA132017EN Two- and three-phase MagneX interrupter Installation The MagneX interrupter is mounted under-oil on the primary side of the transformer. No special tools are required. The MagneX interrupter assembly is mounted through the transformer wall. The incoming high voltage lead is connected first to the isolation link or to the current-limiting fuse and then to the MagneX interrupter. The coil lead is then connected to the lower MagneX interrupter connection point (See Figure 7). Refer to Service Information MN132005EN Two- and Three-Phase MagneX Interrupter Installation Instructions for details. Figure 7. Lead connection points. Production tests CONNECTION POINT FOR ISOLATION LINK (2 PHASE ONLY) OR ELSP (PARTIAL RANGE CURRENT LIMITING) FUSE (2 OR 3 PHASE) [THE HIGH VOLTAGE LEAD (FROM BUSHING) IS CONNECTED TO THE OTHER END OF THE ISOLATION LINK OR ELSP FUSE] CONNECTION POINT BETWEEN MAGNEX AND CORE COIL Tests are conducted in accordance with Eaton requirements. % Physical Inspection % Electrically Tested to Meet Minimum Trip and Maximum Trip Clear TCC Curves Periodic Fluoroscopic Analysis Ordering information The three-phase MagneX interrupter is available in two design variations. The first is a single-phase sense, single-phase trip version, for wye-connected transformers. This design is ideal for applications where customers desire fault sensing on one phase and tripping on that phase only. This option can be used with either an isolation link4(recommended as a minimum) or backup current- limiting fuse. The second three-phase MagneX interrupter design option is a single-phase sense, three-phase trip version, for delta connected transformers. This design is well suited for three-phase delta connected transformer applications (this design should NOT be used on wye-connected transformer primaries). The three-phase MagneX interrupter with single-phase sense, three-phase trip should always be used with backup current-limiting fusing. For three-phase delta primary connected transformers, use Table 3 to determine the correct MagneX interrupter sensor size and the appropriate ELSP backup current-limiting fuse required for the application. Use Table 7 to determine the exact MagneX interrupter catalog number. For three-phase wye primary connected transformers, use Table 4 to determine the correct MagneX interrupter sensor size and the appropriate ELSP backup current-limiting fuse required for the application, or refer to Table 6 for the appropriate isolation link. Use Table 7 to determine the exact MagneX interrupter catalog number. For the two-phase MagneX interrupter, refer to Table 5 to determine the correct MagneX interrupter sensor size for the application. Use Table 6 to determine the appropriate isolation link, or Table 9 to determine the appropriate ELSP backup current-limiting fuse for the application. Use Table 7 to determine the exact MagneX interrupter catalog number. NNote: When ordering a MagneX interrupter, the standard handle kit and hardware must be ordered separately. See Table 8 for the appropriate handle and hardware kit catalog number. Table 3. 3-Phase MagneX Interrupter Recommendations for Transformers with Delta Connected Primary Windings (Single-Phase Sense, Three-Phase Trip) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX 1.60 65 75 1.60 112.5 1. E25 125 4.16 1 2.00 E 1 225 3.00 E 1 0 3. E 165 1.60 75 1.60 65 112.5 1. 1 7.2-7.96 2.00 225 3.00 E25 0 3. E 125 0 4.00 E 1 ELSP Rating without Emergency Overload 4

Two- and three-phase MagneX interrupter Catalog Data CA132017EN Table 3. 3-Phase MagneX Interrupter Recommendations for Transformers with Delta Connected Primary Windings (Single-Phase Sense, Three-Phase Trip) (continued) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX 1.60 75 1.60 112.5 1. 1 2.00 65 12-12.47 225 3.00 0 3. E25 0 4.00 E 7 5.75 E 1 1.60 75 1.60 112.5 1. 1 2.00 225 13.2 3.00 65 0 3. 0 4.00 E 7 5.75 125 0 5.75 E 1 1. 75 2.00 112.5 2.00 1 3.00 65 225 4.00 20 0 4.00 E25 0 4.00 E 7 5.75 0 5.75 E 12 5.75 E 1 1. 75 2.00 112.5 2.00 1 3.00 65 225 4.00 22 0 4.00 0 4.00 E25 7 5.75 E 0 5.75 12 5.75 E 125 ELSP Rating without Emergency Overload Notese: MagneX interrupter recommendations based on Minimum trip curves, and Maximum trip and clear curves, R2-91-2. Deration factor of 0.5% per degree C above ambient (25 C). Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard Guide for Loading Distribution Transformers, Table 6. MagneX/ELSP coordinations based on coordination requirements of single-phase sense, three-phase trip version MagneX interrupter. Proper coordination requires delta connected transformer primary. Proper protection requires that a backup current-limiting fuse be used in series with each MagneX interruption chamber. DO NOT USE AN ISOLATION LINK WITH THE THREE-PHASE MAGNEX INTERRUPTER. Failure to use backup current-limiting fuse in series with the MagneX interrupter can result in an unprotected phase. Backup current limiting fuse may be rated for line-to-neutral voltage, as the three-phase MagneX interrupter is three-phase rated. Added backup protection can be achieved using phase-to-phase rated backup current-limiting fuse. 5

Catalog Data CA132017EN Two- and three-phase MagneX interrupter Table 4. 3-Phase MagneX Interrupter Recommendations for Transformers with WYE Connected Primary Windings (Single-Phase Sense, Single-Phase Trip) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX 1.60 75 1.60 112.5 1. E25 4.16 1 2.00 E 125 225 3.00 1 0 3. E 1 1.60 75 1.60 112.5 1. 1 7.2-7.96 2.00 225 3.00 E25 0 3. E 0 4.00 E 1 1.60 75 1.60 112.5 1. 1 2.00 12-12.47 225 3.00 0 3. E25 0 4.00 E 7 5.75 E 125 1.60 75 1.60 112.5 1. 1 2.00 13.2 225 3.00 0 3. 0 4.00 E 7 5.75 1.60 75 1.60 112.5 1. 1 2.00 225 20.8 3.00 0 3. E25 0 4.00 E25 7 5.75 0 5.75 E 1.60 75 1.60 112.5 1. 1 2.00 225 22.86 3.00 0 3. 0 4.00 7 5.75 0 5.75 E 125 ELSP Rating without Emergency Overload 6

Two- and three-phase MagneX interrupter Catalog Data CA132017EN Table 4. 3-Phase MagneX Interrupter Recommendations for Transformers with WYE Connected Primary Windings (Single-Phase Sense, Single-Phase Trip) (continued) Transformer kva Rating Primary Voltage Assumed Minimum Impedance Recommended MagneX 1.60 75 1.60 112.5 1. 1 2.00 225 3.00 0 24.94 3. 0 4.00 7 5.75 E25 0 5.75 E 10 5.75 E 125 2000 5.75 E 1 1.60 75 1.60 112.5 1. 1 2.00 225 3.00 0 27.6 3. 0 4.00 7 5.75 E25 0 5.75 E 10 5.75 2000 5.75 E 125 1.60 75 1.60 112.5 1. 1 2.00 225 3.00 0 3. 34.5 0 4.00 7 5.75 0 5.75 E25 10 5.75 2000 5.75 E 125 20 5.75 E 125 ELSP Rating without Emergency Overload Notese: Line-to-neutral rated fuses can be used on Gnd Y-Gnd Y transformers with less than % delta loading MagneX Interrupter recommendations based on Minimum trip curves, and Maximum trip and clear curves, R2-91-310. Deration factor of 0.5% per degree C above ambient (25 C). Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard Guide for Loading Distribution Transformers, Table 6. MagneX/ELSP coordinations based on coordination requirements of single-phase sense, single-phase trip version of the MagneX interrupter. Proper coordination requires WYE connected transformer primary. Backup current limiting fuses may be rated for line-to-neutral voltage for Gnd Y-Gnd Y connections, with less than % delta loading ONLY. If this guideline is not followed, recovery voltages exceeding the backup current-limiting fuse may cause fuse failure. In all other cases, voltage rating of the backup current-limiting fuse must be line-to-line rated. Notee: The MagneX Interrupter recommendations above 22 kv are for Gnd Y-Gnd Y transformers with less than % delta loading ONLY. 7

Catalog Data CA132017EN Two- and three-phase MagneX interrupter Table 5. Two-Phase MagneX Interrupter Recommendations Primary Voltage kv kva/kv 2.4 4.16-4.8 6.9-8.0 12.00-14.4 19.92 10 15 25 37.5 75 167 E E - E25 E Notese: Recommendations are based on: Minimum trip curves, and Maximum trip and clear curves, R2-91-310. Deration factor of 0.5% per C above 25 C. Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard, Guide for Loading Distribution Transformers, Table 6. Table 6. Isolation Link MagneX Interrupter Correlation Chart Number Isolation Link 36373B01 36373B08 36373B02 36373B09 36373B10 36373B03 E25 36373B03 E 36373B05 36373B05 E 36373B05 Table 7. Hardware Kit Description Catalog Number Standard Handle Kit & Hardware, w/o Emergency Overload 3638535A09 Hotstick Adapter 3639585A01 Two- and three-phase MagneX interrupter is not yet available with emergency overload feature. Table 8. MagneX Interrupter Significant Digit Catalog Number System Example: To order a three-phase MagneX Interrupter with single-phase sense, three-phase trip, with float and sensor, the catalog number would be MX3BN1MD Standard Options Digits: 1 2 3 4 5 6 7 8 9 10 11 M X 3 B N 1 M D E 1 2 Product MagneX Phases 2-Two 3-Three Indicator B-w/o Indicator Overload N-Non EO Float 1-w/Float 2-w/o Float Trip Type M-Multi-Phase Trip* S-Single-Phase Trip** Notee: For 2-Phase MagneX must be M * If M, only select D for System Connection (digit 8) **If S, only select Y for System Connection (digit 8) System Connection D-Delta Y-Wye Notee: For 2-Phase MagneX must be D Size E25 E E Digits 7 8 M D MD-Multi-Phase Trip with Delta System Connection S Y SY-Single-Phase Trip with Wye System Connection Notee: Choose MD for Two-Phase MagneX interrupter 8

Two- and three-phase MagneX interrupter Catalog Data CA132017EN Table 9. Recommended Two-Phase MagneX Interrupter and ELSP Current-Limiting Fuse Combinations 8.3 kv 15.5 kv 23 kv Nominal Single Phase (kv Phase to ground) 2.4 4.16-4.8 6.9 8.0 12.0 14.4 16.34 19.92 10 kva 15 kva. 25 kva 37.5 kva kva 75 kva kva 167 kva 1 1 E 1 1 1 2 E 65 125 E25 1 165 165 1 E Notese: Table shows minimum recommended ELSP Fuse ratings. Recommended ELSP backup fuse (described in Catalog Section 2-) will coordinate with the MagneX interrupter and melt on internal transformer faults. The MagneX interrupter recommendations are based on: Minimum trip curves, and Maximum trip and clear curves R2-91-310. Deration factor of 0.5% per C above 25 C. Allowable loading greater than 1% for four hours in accordance with IEEE Std C57.91 1981 standard, Guide for Loading Distribution Transformers, Table 6. 125 1 9

Catalog Data CA132017EN Two- and three-phase MagneX interrupter 10

Two- and three-phase MagneX interrupter Catalog Data CA132017EN 11

Catalog Data CA132017EN Two- and three-phase MagneX interrupter Eaton 0 Eaton Boulevard Cleveland, OH 44122 United States Eaton.com Eaton s Cooper Power Systems Division 20 Badger Drive Waukesha, WI 53188 United States Eaton.com/cooperpowerseries 2015 Eaton All Rights Reserved Printed in USA Publication No. CA132017EN Eaton, Cooper Power, and MagneX are valuable trademarks of Eaton in the U.S. and other countries. You are not permitted to use these trademarks without the prior written consent of Eaton. IEEE Std C57.91-1981 standard is a trademark of the Institute of Electrical and Electronics Engineers, Inc., (IEEE). This publication is not endorsed or approved by the IEEE. Viton is a registered trademark of the E. I. DuPont Demours and Company. For Eaton's Cooper Power series MagneX interrupter product information call 1-877-277-4636 or visit:.