INSTRUCTIONS TS93 GSR PT RIGHT HAND ACTIVE LEFT HAND INACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE

Similar documents
TS93 STH. Surface applied door closer. Installation instructions: Pull side door mounted spring track Inverted closer with hold open (STH)

Installation Type. Edge of Door. Pull (Hinge) Side Mounted. Hinge Edge of Door. Push (Stop) Side Mounted

Installation Instructions

316R Series Installation Instructions

Installation Instructions. Installation Type

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUO (JO & JP9) ARMS

Installation Instructions. Installation Type

SARGENT 1331 DOOR CLOSER INSTALLATION INSTRUCTIONS WITH JUH (HOLD OPEN) ARMS

TOOLS REQUIRED Metal Wood Wood and Metal Screws. #16 Drill #12-24 Tap. 1/8 Drill

351 DOOR CLOSER WITH DOUBLE LEVER ARM (OP) INSTALLATION INSTRUCTIONS

(Wood Door and Frame)

INSTRUCTIONS FOR 1431 Door Closer with Hold Open Arms 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

Regular Arm Installation. Closer mounts on hinge side of door (pull side) See Page 3. Closer cover not shown. Top Jamb Installation

98/9927. Devices covered by these instructions: Surface Vertical Rod Exit Device

D3976 RECESSED EXIT INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CRL JACKSON

Calf-Tel Pen System Assembly Instructions

CONCEALED VERTICAL ROD PANIC EXIT DEVICE

ED5800 (A) Series. Installation Instructions. Concealed Vertical Rod. Exit Device WARNING

ED1300/1300F SERIES CONCEALED VERTICAL ROD DEVICE INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS CRL JACKSON

INSTALLATION INSTRUCTIONS FOR INSTALLING T-SERIES EXTRA HEAVY DUTY LEVER LOCKSET

*D-1030* 1 PARTS CHECK 8 REVERSING INSTRUCTIONS F-XX-C & XX-C D Customer Service. Installation Instructions. Exit Devices

How To Measure Your Finished Opening

DC3210. Recommended Closer Size

Note: The dimensions of the Template are shown in inches. See attached page for the Metric Conversion Table for millimeters.

5200 Series Door Closer Installation Instructions

PRO / PL SHOE REPLACEMENT & CONVERSION INSTRUCTIONS

These door closers should NOT be installed on the exposed side (weather side) of exterior doors. WOOD 3/16" 1/4"- 20

Safety glasses Measuring tape Level Pencil Power drill Center punch Phillips screw driver Saw horse

Important: Read this first!

INSTALLATION INSTRUCTIONS

1530(F) Mortise Exit Devices Installation Instructions

For installation assistance, contact SARGENT at DOORS SHOWN HERE SWING IN FOR ILLUSTRATION PURPOSES ONLY.

33/35A Series. Devices covered by these instructions: Rim Exit Device. CD33/35A Rim Exit Device EL33/35A Rim Exit Device SS33/35A Rim Exit Device

Active Push Bar. Safety glasses Measuring tape Level Pencil Power drill Drill bits: 5/32, 3/4 Center punch Phillips screw driver

INSTALLATION INSTRUCTIONS CRL JACKSON

TABLE OF CONTENTS REQUIRED TOOLS

Installation Instructions

Quill Stop V2 Installation Guide 11/16/2014

ASSA ABLOY Series Installation Instructions. Regular Arm. Parallel Arm. Top Jamb Mount. Multi-Sized 1 thru 6 Non-Hold Open and Hold Open Models

BOX-117 E-Z-Go RXV Utility Box Mounting Kit Installation Instructions

33/3547A. Special tools needed: #10-24 tap Drill bits: #25, 5/16, 13/32, 1/2

7110(F), 7170(F)(LBR) Surface Vertical Rod Exit Device Series Installation Instructions

Packing List MODEL TEL-IAL-481 For Inactive Leaf TRIDENT double door

TIRE RACK INSTALLATION INSTRUCTIONS Dodge Sprinter

BX2173 Installation Instructions Ford Focus (including the 2.3L engine) 2003 Ford Focus SVT

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

Introduction. Rocky Mountain Westy Swing Away Carrier Kit Installation Instructions

Shim (2) Supplied. Strike Plate. (3) x 5/8" PFHMS or 10 x 1" PFHWS. Top Latch. (3) x 1/4" PRHMS. Latch Cover. (2) 8 x 3/8" PFH AB SMS

EDGE2 DUAL MONITOR ARM

Assembly Instructions 10 X 10 Aluminum Roof Support

Strata. urniture. Adriana Instructions. Parts in the Arm Box: Parts in the Body Box: Watch our assembly videos at

Bulkhead Model Number and

ASSEMBLY AND ADJUSTMENT

Installation Instructions Model # TEL-100 / 200 Manual Locking or Self Locking

Installation and Assembly - Universal Articulating Swivel Double-Arm for 42" - 60" Plasma Screens

SwingSafe Swing-Away Mailbox Support Diagram

INSTALLATION INSTRUCTIONS

#916 CLASSIC 16 GUN CABINET ASSEMBLY INSTRUCTIONS

Installation Manual for Metal Toilet Partitions Standard Series

FRAME PREPARATION 3900/8900 SURFACE LATCH CONCEALED ROD EXIT DEVICE INSTALLATION INSTRUCTIONS HOW TO FIND BACKSET. Date: Appvd: *13/16 2 3/4" 3/4 HOLE

BOX-115 Club Car Precedent Utility Box Mounting Kit Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

33/3527A. Devices covered by these instructions: 33/3527A-F (Fire) Surface Vertical Rod Exit Device

EZ-Lock Assembly Manual

AR-15 Armorer s Essentials Kit. Product # Instructions # Revision: B

1431 DOOR CLOSER WITH STANDARD DUTY ARMS (WITHOUT HOLD OPEN) INSTALLATION INSTRUCTIONS 1431 SERIES ADJUSTABLE FROM SIZE 1 THRU 6

* * 98/9950WDC. Fire-Rated Devices include these. additional components. 1-Point Latch (LBL)

Series 1100 Aluminum Door Canopy

IDR assembly instructions:

Warnings. Description. Prior to Installation Tools Needed

4600 Series Rim Narrow Stile Exit Device Installation Instructions I-ED01162

OPERATOR ADAPTER SQDV

MantelMount. TM1A Installation Instructions IMPORTANT SAFETY INSTRUCTIONS - SAVE THESE INSTRUCTIONS

OPERATOR ADAPTER ECHV

Installation Instructions

Please read BOTH these Installation Instructions and the General Towing Instructions before attempting to install or operate this equipment.

BOX-118 E-Z-Go TXT Utility Box Mounting Kit Installation Instructions

INSTALLATION MANUAL. All Recessed Wall-Mount Modules Front-Loading, Rear-Loading, Parcel-Only, Collection Box, Trash/Recycling Bin

AndyMark DART 12.

Assembly Instructions

IMPORTANT: installation. FLOOR ANCHORED CEILING HUNG OVERHEAD BRACED FLOOR-TO- CEILING ANCHORED

INSTALLATION INSTRUCTIONS

Fig. 2 DORMA-Glas Stand/Issue 02/03 Seite/Page 1/7

Oxford Stalls Installation Instructions

Dublin Stalls Installation Instructions

ProLogic Xtreme L22 - Electromechanical Redundant Safe Lock System - Instructions

Installation for Full Size Polaris Ranger Crew Doors

Wooden Frame Type Instruction Manual

1500(F) Rim Exit Devices Installation Instructions

TorqueMaster Replacement Spring

Series 1500 Aluminum Door Canopy

MITCHELL WREATH RINGS NO-HAMMER ASSEMBLY INSTRUCTIONS

INSTRUCTION SHEET U19

Two Panel Frameless Bypass Door

INSTALLATION INSTRUCTIONS

FIGURE 1, TYPE B Active leaf opens both doors. Overlap plates installed on the inactive

P.O. Box 8400 Green Bay, WI (920)

Transcription:

INSTRUCTIONS ATTENTION!!! Before you begin, determine installation type (RIGHT HAND ACTIVE OR INACTIVE). Door coordinator suitable for door from 59 to 98 in width. Inactive door width in the case of unequal doors is a minimum. Also, you will need the tools listed below. LEFT HAND INACTIVE RIGHT HAND ACTIVE RIGHT HAND INACTIVE LEFT HAND ACTIVE Tool List: Tape Measure #0- Tap & Holder No. (.59 ) & /8 Drill Bits and Drill Hacksaw Center Punch & Hammer / Box Wrench # Cross-Point Screw Driver /6 Slotted Driver 0 Adjustable Wrench.5mm, mm & 5mm Hex Wrench (supplied) INS NO: 088850PAGE: of 9 REV: 0/

CAUTION: Sex nuts are required for attachment of components to unreinforced, wood or plastic faced composite type fire doors, unless an alternative method is identified in the individual door manufacture s listings. Make sure door efficiently operates prior to installing the closer. When Installing main arm, observe directions closely.. Prepare door and frame using the template (TMP No. 08800) provided in the back of the instructions. Attach both closer mounting plates to the doors using 8 flat head screws, ea. Arrows on plate pointing upwards. Attach left hand mounting angle to the frame with flat head screws. Attach right hand mounting angle to the frame with flat head screws. Left Hand Right Hand Cut middle filler angle as shown below Attach Middle Filler Angle with flat head screws. Parts List: No. Description ) Closer Mounting Plate ) Track Mounting Angle ) Middle Filler Angle (cut) ) Wood Door Screws 5) #0- Metal Door Screws Qty 6 6 Wood Door Screw 5 Cut #0- Metal Door Screw When cutting filler angle be sure to plan for the conduit hole 5/6 DIA [8mm]. INS NO: 088850 PAGE: of 9 REV: 0/

Attach active track assembly with two M5 flat head machine screws, be sure to insert the end cap as shown below. Attach the Inactive Track Assembly with two M5 Flat Head Machine Screws, be sure to insert the end cap. The following describes the process for a left-handed active leaf. The procedure for right-hand active leaf should be adapted accordingly. Left Hand Active Door Right Hand Inactive Door Parts List: No. Description ) Active Track Assembly ) Inactive Track Assembly ) M5 Metal Track Screws ) Plastic End Cap 5) TS9 Closer 6) M5 Closer Mounting Screws Qty 8 Attach closers with eight (8) M5 flat head machine screws. M5 Metal Track Screws 6 M5 Closer Mounting Screws 5 6 INS NO: 088850 PAGE: of 9 REV: 0/

5 Place wrench on bottom of pinion square and rotate approximately 5 degrees as shown. With the main arm parallel to the door. Place the main arm hub on to the top pinion square and fasten securely with pinion screw. 5mm Hex Key M6 Socket Head Screw Track Arm Left Hand Right Hand 6 Attach arm to slide shoe. Continue to rotate arm until parallel to track (door closed). Insert screw and tighten securely. 5mm Hex Key Slide Shoulder Bolt Note: Depress trigger dial, (see page 5) to allow the active slide shoe to move freely. Locking pin may fall out, (see page 6) and can be discarded after installation is complete. Parts List: No. Description ) Hex Key ) M6 Socket Head Screw ) Track Arm ) Slide Shoulder Bolt Qty M6 Socket Head Screw Slide Shoulder Bolt INS NO: 088850 PAGE: of 9 REV: 0/

7 Close both door leaves. Press lever with roller against the door (A) and tighten the hex screw (B). Remove Alignment screw (C). 7C D O O R DOOR 7B SIDE VIEW ROLLER 7A 8 Mark and cut the length of the connecting channel as shown. In doing so, it will ensure that the plastic guide element is pushed up against the slide shoe, and the trigger dial has been fully turned in (clockwise). Cut the connecting channel at the cut mark. Remove burrs and set the connecting channel in place by opening both doors leaves. Move arm with roller to maximum degree, in the direction of the open door leaf. Insert the channel into the trigger dial of the active leaf and then place into the plastic guide of the inactive leaf. Trigger Dial Plastic Guide Side view of Connecting Channel INS NO: 088850 PAGE: 5 of 9 REV: 0/

9 Close both door leaves. Unwind the trigger dial (counter clockwise) by hand until the pin drops out. The active door will starts to close. Ensure that the clamping plate remains perpendicular (90 deg) to the clamping rod. Tighten set screw to secure trigger dial. 0 The clamping rod will only operate smoothly if the clamping plate has been properly adjusted. Only then will the active leaf swing freely with the inactive leaf closed. Pin can be discarded once the system has been installed. INS NO: 088850 PAGE: 6 of 9 REV: 0/

Adjust sweep (S), latch (L), backcheck (BC) and delay action (DA) valves. L BC S DA CAUTION: DO NOT REMOVE VALVE!!! Adjust Sweep (S), Latch (L) valves. DECREASE SPEED INCREASE SPEED Adjust Backcheck (BC) and delay action (DA) valves. DECREASE (BC INTENSITY) INCREASE (DA TIME) S - Sweep speed from 70 deg opening to close (0 deg). L - Latch speed from approximately 7 deg to close (increase speed only). BC - Backcheck cushion effect (IMPORTANT Do NOT close valve completely)! DA - Delay speed from approximately 5 deg to 70 deg. Adjust spring power (IMPORTANT: Adjust clockwise according to chart). Barrier free openings should be adjusted to use the minimum closing force required to close and latch the door. INS NO: 088850 PAGE: 7 of 9 REV: 0/

INSTALL END CAP TRIM AND COVERS Clip on end cap trims. Break out marked recess in the active and inactive leaf track cover and clip cover into position ACTIVE LEAF COVER INACTIVE LEAF COVER End cap trim INSTALL CENTER COVER AND CENTER CAPS Determine the required length of centre cover and saw to size. Clip on cover. Break out marked recess on plastic trim for inactive leaf. Fit plastic jointing elements. JOINTING ELEMENTS CENTER COVER JOINTING ELEMENTS INS NO: 088850 PAGE: 8 of 9 REV: 0/

5 INSTALL CLOSER COVERS Install closer end covers and closer covers. 6 Slide end covers over closer body end caps. Remove tab that aligns with arm hub. Slide cover onto plate. INSTALL CARRY BAR A carry bar must be installed to insure that the active door is opened far enough for the inactive door to close. DORMA carry bar MK-98 ( -6 and wider door) is required! Installation instructions are included with the carry bar. Secure with locking screw. 7 FINAL INSTALLATION AND TEST. After installation is complete, check all connections.. Open doors to desired position.. For EMF activate system in alarm so the electromagnets release, and the doors close. Normal Operation - The unit s electromagnet will be energized by the alarm system, by applying VDC power supply. Fire Alarm - When the alarm activates, current will automatically be cut, causing the electromagnets to release, allowing the doors to close. IMPORTANT: The unit must be tested after installation, by the end user, to be certain the door closer unit functions properly when the alarm system is activated. The entire system must be tested periodically after the initial installation test, in conjunction with the testing of the fire alarm system. The end user is responsible for maintaining the door closing system. INS NO: 088850 PAGE:9 of 9 REV: 0/