Precipitation Monitor ,

Similar documents
Precipition Sensor with analogue Intensity Output ,

Wind Transmitter compact xx

Wind Transmitter - with frequency output xx.xxx

Wind Transmitter - compact

Wind Transmitter - with analogue output xxx

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter - compact - TMR, analogue output x.xxx xxx

FINAL. Hygro-ThermoTransmitter-compact xxx xxx MEETINSTRUMENTATIE. Instruction for use /06/ x4.0xx/1xx/4xx/8xx...

Instruction for Use /05/09. Wind Transmitter - compact x0.xxx x0.xx x0.xx0

Wind Direction Transmitter - compact - GMR, analogue output xxx xxx

Combined Wind Transmitter - with analogue output xxx

Wind Direction Transmitter First Class analogue output x0.1xx

Wind Transmitter First Class Advanced Classified according to IEC ( )

Brightness Transmitter

Wind Direction Transmitter First Class analogue output x0.1xx

Precipitation Transmitter / 008 / 009 / 010 / 011 / 107 / / 009

Baro Transmitter PTB x1.073

Brightness Transmitter - direction-independent xxx

Wind Direction Transmitter First Class Low Power Device with digital output, 8 Bit serial-synchronous x0.000

Hygro-ThermoTransmitter-compact xxx

Precipitation transmitter

Wind Transmitter First Class

Wind Transmitter First Class / 141 / / 141 / 161

Wind Transmitter compact xx

Precipitation Transmitter xxx / xxx

Baro Transmitter xxx

Wind Direction Transmitter - compact - GMR, analogue output xxx

Digital Anemometer

Wind Direction Transmitter - compact - with Poti Output xx.712

Wind Direction Transmitter First Class - Device with digital output, RS Wind velocity signal acquisition x0.400

Wind Direction Transmitter - compact

Wind Direction Transmitter - compact - with serial output x0.x00

Sensor PAR xxx

SEPARATOR P20G TYPE USER S MANUAL

TETRIS 1000 High Impedance Active Probe. Instruction Manual

Liquid level monitoring relay CM-ENS.2x

INSTRUCTION MANUAL. TC041-L Precipitation Sensor (Precipitation Occurrence & Rainfall Intensity) Sept 2008

Operating Instructions Wind Sensor with Heating Heating Transformer Rain Sensor

VFSC9 ELECTRONIC SPEED CONTROLLER. Mounting and operating instructions

QUINT-PS AC/24DC/40

Operating Instructions / Voltage Tester per IEC with Phase and Polarity Tester and Phase Sequence Indicator

Power supply CP-D 12/2.1

Operating Manual * * Differential pressure transmitter. Table of Contents. 1 Safety guidelines. 1.1 General Information

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO-E

ProGap Microwave barrier

Instruction Manual MSC710 MSC710-U MSC710-I

TEMPERATURE CONTROLLER RE21 TYPE

LMM31. Dimmer Micromodule, 1 load USER MANUAL 20410/ LMM31 ALL RIGHTS RESERVED MARMITEK

AC/DC Current Probe GCP-100 QUICK START GUIDE ISO-9001 CERTIFIED MANUFACTURER

PHOENIX CONTACT - 05/2008. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

Radio System Strobe Wizard Plus Freemask

MTV-1-CP 230 VAC POTENTIOMETER WITH MIN & MAX SETTINGS, DRY CONTACT. Mounting and operating instructions

Accessories Solar Datatechnology Wireless-Set485-01/-Set485-02

Combi sensor C B1. A: Wind wheel. west, east, south C: Dawn sensor D: Rain sensor. Ref.-No. with DCF77 receiver WS 10 KSDCF (No KNX device)

QUINT-PS-24DC/24DC/10

POWER TRANSDUCERS FOR SINGLE-PHASE AND THREE-PHASE NETWORK ISO P11P, P13P and P13B mm SERVICE MANUAL

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

ERV-M ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

Franck-Hertz Control Unit

Panther. Installation instructions. Receivers PN-R15-1 PN-R15-2 PN-R15-13 PN-R IM-PN-RX103-A03-EN Language: English (original)

PHOENIX CONTACT - 06/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

Operating Instructions for Pressure Sensor with Ceramic Sensor Element. Model: SEN-9601

Endress Hauser. SmarTec M CLD 133 Conductivity Measurement

TRANSDUCER of TEMPERATURE and STANDARD SIGNALS P20 type

RE17RCMU off-delay timing relay - 1 s..100 h V AC - 1 OC

QUINT-PS/ 3AC/24DC/10

OPERATION MANUAL ELECTRONIC FREQUENCY CONVERTER HFO E

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

MDW-45 Converter RS RS-422/485

RE17LLBM asymmetrical flashing relay s V AC - solid state output

Top spin Nr /

RAIL MOUNTED NETWORK METER TYPE N27D USER S MANUAL

OEM miniature resistance thermometer Models TR31-3 and TR31-K, thread-mounted

Three-phase monitoring relay CM-PFS

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

METEOROLOGICAL INSTRUMENTS

HAWK5000 Operators Manual

METEOROLOGICAL INSTRUMENTS

Technical manual. Microstep driver SMC11. NANOTEC ELECTRONIC GmbH & Co. KG Gewerbestraße 11 D Landsham near Munich, Germany

Active Transmitter Combiner 8:1 AC 3200-II. Instruction manual

RE17RAMU on-delay timing relay - 1 s..100 h V AC - 1 OC

RSMFX-2R MULTIFUNCTIONAL

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

MD-45 AC MD-45 LV/HV INSTALLATION MANUAL

MINI MCR-SL-UI-I-LP-NC

Weather Station for KNX

Original operating instructions Fail-safe inductive sensor GG507S / / 2013

BENNING. CM7 Electrical Tester. Service Information

Power supply CP-E 24/2.5

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

RE17RMMW time delay relay 10 functions - 1 s..100 h V AC/DC - 1 OC

Power supply CP-D 24/1.3

RE17RMMU time delay relay 10 functions - 1 s..100 h V AC - 1 OC

4-Port Antenna ircu / /65 16/18.5dBi 0 10 /0 10 T V01

UMG 96L / UMG 96. UMG 96L / UMG 96 Universal measurement device. Threshold value monitoring. Pulse outputs. Networks TN-, TT-Networks

METRATESTER 5+ Tester for DIN VDE /6.15

Power supply CP-E 24/20.0

English. Operating manual. Temperature measuring transducer MU125. Save for later reference. Company / brands of GHM

Instruction manual for STA 1 sectional door operator

Transcription:

THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA - THE WORLD OF WEATHER DATA Instruction for use 021197/11/09 Precipitation Monitor 5.4103.10.000, 5.4103.10.700 ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com

Safety Instructions Before operating with or at the device/product, read through the operating instructions. This manual contains instructions which should be followed on mounting, start-up, and operation. A non-observance might cause: - failure of important functions - Endangering of persons by electrical or mechanic effect - Damages at objects Mounting, electrical connection and wiring of the device/product must be carried out only by a qualified technician who is familiar with and observes the engineering regulations, provisions and standards applicable in each case. Repairs and maintenance may only be carried out by trained staff or Adolf Thies GmbH & Co. KG. Only components and spare parts supplied and/or recommended by Adolf Thies GmbH & Co. KG should be used for repairs. Electrical devices/products must be mounted and wired only in voltage-free state. Adolf Thies GmbH & Co KG guarantees proper functioning of the device/products provided that no modifications have been made to the mechanics, electronics or software, and that the following points are observed: All information, warnings and instructions for use included in these operating instructions must be taken into account and observed as this is essential to ensure trouble-free operation and a safe condition of the measuring system / device / product. The device / product is designed for a specific application as described in these operating instructions. The device / product should be operated with the accessories and consumables supplied and/or recommended by Adolf Thies GmbH & Co KG. Recommendation: As it is possible that each measuring system / device / product under certain conditions, and in rare cases, may also output erroneous measuring values, it is recommended to use redundant systems with plausibility checks with security-relevant applications. Environment As a longstanding manufacturer of sensors Adolf Thies GmbH & Co KG is committed to the objectives of environmental protection and is therefore willing to take back all supplied products governed by the provisions of "ElektroG" (German Electrical and Electronic Equipment Act) and to perform environmentally compatible disposal and recycling. We are prepared to take back all Thies products concerned free of charge if returned to Thies by our customers carriage-paid. Make sure you retain packaging for storage or transport of products. Should packaging however no longer be required, arrange for recycling as the packaging materials are designed to be recycled. Documentation Copyright Adolf Thies GmbH & Co KG, Göttingen / Germany Although this operating instruction has been drawn up with due care, Adolf Thies GmbH & Co KG can accept no liability whatsoever for any technical and typographical errors or omissions in this document that might remain. We can accept no liability whatsoever for any losses arising from the information contained in this document. Subject to modification in terms of content. The device / product should not be passed on without the/these operating instructions. 2-12 021197/11/09

Contents 1 Model... 4 2 Application... 4 3 Mode of Operation... 4 4 Installation... 4 4.1 Mechanical Mounting... 5 4.2 Electrical Mounting for Precipitation with Cable Gland... 5 4.3 Electrical Mounting for Precipitation with Plug Connection... 6 4.3.1 Plug Mounting... 6 5 Taking into Operation... 6 6 Maintenance... 6 7 Setting of Incidences and Switch-off Delay... 7 8 Connecting Diagram... 8 9 Technical Data... 9 10 Dimension diagram... 10 11 Accessories... 10 12 EC-Declaration of Conformity... 11 Tables Table 1: DIP switch adjustment... 7 3-12 021197/11/09

1 Model Order - No. Measuring value Electrical Output Operating Voltage Connection 5.4103.10.000 Precipitation status Relay 24 V AC/DC Cable gland 5.4103.10.700 Precipitation status Relay 24 V AC/DC 7- pole plug connection 2 Application The precipitation monitor transmits signals to determine the beginning and the end of precipitation and the duration of the period of precipitation as required by meteorological services. In addition, the precipitation monitor can be used to report status or to transmit control signals to connected rain protection devices such as windows, air vents, awnings, or Venetian blinds. 3 Mode of Operation Precipitation in the form of drizzle, rain, snow or hail is detected by means of a light barrier system and triggers a signal. A built-in incidence-filter shall smooth the triggering of switching signals in case of individual incidences, as for example leafs, bird droppings, insects etc. For this, a certain number of at least n incidences should have occurred within a time-window of 50 sec. The number of drop incidences (1 15) can be selected through the DIP-switch on the pc-board. With the precipitation end the switching signal is reset after a selectable switch-off delay. Thanks to the immediate evaluation of the incidences it is possible to determine precisely the beginning and end of the precipitation period. The instrument is equipped with a heating system for extreme weather condition. This avoids ice and snow forming on the housing surface. In addition, the surface retains a temperature of >0 by means of a regulated heating. 4 Installation Please Note: The electrical connection is to be carried out by experts only. Please open the instrument only with dry ambient conditions. Do not damage the exposed electronics! 4-12 021197/11/09

Remark: In order to achieve an optimal electro-magnetic immunity (> 20 V/m) please use shielded cable. 4.1 Mechanical Mounting The mounting system of the instrument is designed for attachment to a mast. When mounting make sure, that the precipitation can easily reach of the sensor field, and that the instrument, while operating, is not exposed to strong vibrations or shocks. Sensor field 4.2 Electrical Mounting for Precipitation with Cable Gland To connect the instrument electrically, remove the cover with its 5 screws. The connecting terminals and the DIP-switches for selecting the number of incidences and switch-off delays are then accessible. The electrical connection is carried out according to the Circuit diagram. Insert the cable from below through the screwed cable gland on the bottom of the case and connect it to the connecting terminals and the shield connection. After the wiring and mounting work is done, the nuts of the screwed cable gland, and die screws of the cover are to be screwed evenly tight with the case so that water cannot penetrate it. The fixing screws for the cover must be srewed down with a torsional of 1 Nm to 2 Nm. 5-12 021197/11/09

4.3 Electrical Mounting for Precipitation with Plug Connection The electrical connection is carried out by plug in accordance with the connecting diagram. 4.3.1 Plug Mounting Applies only to instruments with connection plug. Coupling socket, Typ:Binder, Serial 423, EMC with cable clamp Cable connection: without cable shield Cable- pull- relief 1. Stringing parts on cable acc. to plan given above. 2. Stripping cable sheath 20 mm 3. Cutting uncovered shield 20 mm 4. Stripping wire 5mm. 5. Soldering wire to the insert 6. Positioning shield in cable clamp. 7. Screwing-on cable clamp. 8. Assembling remaining parts acc. to upper plan. 9. Tightening pull-relief of cable by screw-wrench (SW16 und 17). Cable clamp Wire Cable sheath 5 Taking into Operation After the electrical connection has been established, and the case has been screwed, the operating voltage can be switched on. The setting of the relay output is undefined after switching on the operating voltage and shows no precipitation. 6 Maintenance The device is maintenance free. Cleaning: The pollution and the pollution level is dependent on the location. Therefore, we recommend the unit be checked at appropriate intervals and cleaned if necessary. For the cleaning should use a damp cloth without chemical cleaning agents are used. 6-12 021197/11/09

7 Setting of Incidences and Switch-off Delay In the factory a setting is carried out for 12 drop incidences within 50 seconds with a switchoff delay of 25 seconds. If this setting is to be changed, the switch-off delay, and the number of drop incidences are set through the DIP-switches acc. to the table. DIP2 DIP1 DIP1- switch-off delay DIP2- drop incidences-filter S 1 S 2 S 3 S 4 Time(sec) S 1 S 2 S 3 S 4 drops ON OFF OFF OFF 25 ON OFF OFF OFF 1 OFF ON OFF OFF 50 OFF ON OFF OFF 2 ON ON OFF OFF 75 ON ON OFF OFF 3 OFF OFF ON OFF 100 OFF OFF ON OFF 4 ON OFF ON OFF 125 ON OFF ON OFF 5 OFF ON ON OFF 150 OFF ON ON OFF 6 ON ON ON OFF 175 ON ON ON OFF 7 OFF OFF OFF ON 200 OFF OFF OFF ON 8 ON OFF OFF ON 225 ON OFF OFF ON 9 OFF ON OFF ON 250 OFF ON OFF ON 10 ON ON OFF ON 275 ON ON OFF ON 11 OFF OFF ON ON 300 OFF OFF ON ON 12 ON OFF ON ON 325 ON OFF ON ON 13 OFF ON ON ON 350 OFF ON ON ON 14 ON ON ON ON 375 ON ON ON ON 15 Table 1: DIP switch adjustment Grey marked squares = factory settings DIP switch adjustment OFF, OFF, OFF, OFF : not defined 7-12 021197/11/09

8 Connecting Diagram Order-No. 5.4103.10.000 yes precipitation no R W A + - Pg 1 2 3 4 5 switch loading max. 230V AC/DC max. 4A AC/DC max. 1000VA (Ohm) power supply 24V AC/DC earth Order-No. 5.4103.10.700 Plug connection yes Precipitation no View on the soldering side of the counter plug. R W A + - 3 4 7 pin Binder Plug 2 7 5 1 2 3 4 5 6 7 1 6 Switching load max. 60 V AC / DC max. 4A AC / DC max. 1000VA (Ohm) Power Supply 24V AC/DC Earth 8-12 021197/11/09

9 Technical Data Measuring value Output : Status of precipitation (rain, snow, hail, etc.) : Precipitation = relay OFF ( also at U B = 0); no precipitation = relay ON Sensor area : 25 cm 2 Drop size : 0,2 mm Switch-on condition : 1... 15 incidences within 50 sec. Switch-on delay : none Switch-off delay : 25... 375 s ; see Adjusting incidences and switch-off delay Contact loading (relay) with model 5.4103.10.000 : max. 230 V AC; 4 A with model 5.4103.10.700 : max. 60 V AC; 4 A Operating voltage : 24 V AC/DC ± 15 % Operation current : approx. 300 ma @20 C ambient temperature max. approx. 1 A Ambient temperature : -30... +60 C Protection : IP 65 acc. to DIN 40050 EMV : EN 61000-6-2 ; EN 61000-6-3 Weight : 0,4 kg Connection See model 9-12 021197/11/09

10 Dimension diagram 11 Accessories Power Supply Unit 9.3388.00.002 The power supply unit serves for the current supply of the precipitation monitor, order-no. 5.4103.10.000. It supplies the necessary operation voltage for the electronics and the heating. Primary : 230 V / 50 Hz Secondary : 24 V AC / 25 VA Housing : synthetic Protection : IP 65 acc. with DIN 40050 Dimensions : 107 x 125 x 100 mm Weight : 1,2 kg 10-12 021197/11/09

12 EC-Declaration of Conformity Document-No.: 000902 Month: 06 Year: 08 Manufacturer: A D O L F T H I E S G m b H & C o. K G Hauptstr. 76 D-37083 Göttingen Tel.: (0551) 79001-0 Fax: (0551) 79001-65 email: Info@ThiesClima.com Description of Product: Precipitation Transmitter Article No. 5.4103.10.000 5.4103.10.012 5.4103.10.700 5.4103.20.041 5.4103.20.741 5.4103.30.000 5.4103.30.700 specified technical data in the document: 021324/10/04; 021196/12/04; 021334/04/05; 021469/08/05 The indicated products correspond to the essential requirement of the following European Directives and Regulations: 2004/108/EC 2006/95/EC DIRECTIVE 2004/108/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 15 December 2004 on the approximation of the laws of the Member States relating to electromagnetic compatibility and repealing Directive 89/336/EEC DIRECTIVE 2006/95/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 12 December 2006 on the harmonisation of the laws of Member States relating to electrical equipment designed for use within certain voltage limits 552/2004/EC Regulation (EC) No 552/2004 of the European Parliament and the Council of 10 March 2004 on the interoperability of the European Air Traffic Management network (the interoperability Regulation) The indicated products comply with the regulations of the directives. This is proved by the compliance with the following standards: Reference number IEC 61000-6-2: 2005 IEC 61000-6-3: 2006 IEC 61010-1: 2001 Specification Electromagnetic compatibility Immunity for industrial environment Electromagnetic compatibility Emission standard for residential, commercial and light industrial environments Safety requirements for electrical equipment for measurement, control and laboratory use. Part 1: General requirements Place: Göttingen Date: 27.06.2008 This declaration certificates the compliance with the mentioned directives, however does not include any warranty of characteristics. Please pay attention to the security advises of the provided instructions for use. 11-12 021197/11/09

ADOLF THIES GmbH & Co. KG Hauptstraße 76 37083 Göttingen Germany P.O. Box 3536 + 3541 37025 Göttingen Phone +49 551 79001-0 Fax +49 551 79001-65 www.thiesclima.com info@thiesclima.com - Alterations reserved- 12-12 021197/11/09