C400-TMTM-30-X Product Classification Brand Product Series Product Type CNT-400-FR CNT Jumper with interface types TNC Male and TNC Male, 9.14 m CNT CNT-400 Braided cable assembly General Specifications Body Style, Connector A Straight Body Style, Connector B Straight Interface, Connector A TNC Male Interface, Connector B TNC Male Length 9.140 m 29.987 ft Nominal Size 0.400 in Attachment, Connector A Field attachment Attachment, Connector B Field attachment Specification Sheet Revision Level A Electrical Specifications DTF, Connector A DTF, Connector B -28.00 db -28.00 db Jumper Assembly Sample Label page 1 of 14 most current information. Revised: November 10, 2017
C400-TMTM-30-X Regulatory Compliance/Certifications Agency ISO 9001:2008 Included Products Classification Designed, manufactured and/or distributed under this quality management system 400PTM-C TNC Male for CNT-400 braided cable CNT-400-FR CNT-400-FR, CNT 50 Ohm Braided Coaxial Cable, black non-halogenated, fire retardant polyolefin jacket, Dca s2 d2 Compliant 400BPTM-C TNC Male for CNT-400 braided cable 400BPTM-C-CRCR TNC Male for CNT-400 braided cable page 2 of 14 most current information. Revised: November 10, 2017
400PTM-C TNC Male for CNT-400 braided cable OBSOLETE This product was discontinued on: February 25, 2015 Replaced By 400BPTM-C TNC Male for CNT-400 braided cable Product Classification Brand Product Type General Specifications Interface Body Style Electrical Specifications Operating Frequency Band Cable Impedance Connector Impedance RF Operating Voltage, maximum (vrms) dc Test Voltage Outer Contact Resistance, maximum Inner Contact Resistance, maximum Insulation Resistance, minimum Average Power Peak Power, maximum Insertion Loss, typical CNT Braided cable connector TNC Male Straight 0 6000 MHz 50 ohm 50 ohm 500.00 V 1500 V 0.40 mohm 1.50 mohm 5000 MOhm 580.0 W @ 900 MHz 5.00 kw 0.05 db page 3 of 14
400PTM-C Outline Drawing Mechanical Specifications Outer Contact Attachment Method Clamp Outer Contact Plating Trimetal Inner Contact Plating Gold Inner Contact Attachment Method Captivated Interface Durability 500 cycles Interface Durability Method IEC 61169-17:17 Connector Retention Tensile Force 330 N 74 lbf Connector Retention Torque 0.56 N-m 0.41 ft lb Coupling Nut Proof Torque 1.70 N-m 1.25 ft lb Coupling Nut Proof Torque Method IEC 61169-17:9.3.6 Coupling Nut Retention Force 445.00 N 100.04 lbf Coupling Nut Retention Force Method IEC 61169-17:9.3.11 Dimensions Nominal Size Diameter Length Weight 0.405 in 20.00 mm 0.79 in 44.95 mm 1.77 in 44.22 g 0.10 lb page 4 of 14
400PTM-C Width 20.00 mm 0.79 in Environmental Specifications Operating Temperature Storage Temperature Immersion Depth Immersion Test Mating Immersion Test Method Regulatory Compliance/Certifications * Footnotes -40 C to +85 C (-40 F to +185 F) -65 C to +125 C (-85 F to +257 F) 1 m Mated IEC 60529:2001, IP68 Mechanical Shock Test Method IEC 60068-2-27 Climatic Sequence Test Method IEC 60068-1 Damp Heat Steady State Test Method IEC 60068-2-3 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 C 68 F Average Power, Ambient Temperature 40 C 104 F Average Power, Inner Conductor Temperature 100 C 212 F Return Loss/VSWR Frequency Band VSWR Return Loss (db) 0 3000 MHz 1.05 33.00 3000 6000 MHz 1.17 22.00 Agency ISO 9001:2008 Classification Designed, manufactured and/or distributed under this quality management system Immersion Depth Insertion Loss, typical Immersion at specified depth for 24 hours 0.05v freq (GHz) (not applicable for elliptical waveguide) page 5 of 14
CNT-400-FR CNT-400-FR, CNT 50 Ohm Braided Coaxial Cable, black nonhalogenated, fire retardant polyolefin jacket, Dca s2 d2 Compliant Product Classification Brand Product Series Product Type CNT CNT-400 Braided coaxial cable Standards And Qualifications EN50575 CPR Cable EuroClass Dca s2 d2 Construction Materials Jacket Color Jacket Material Braid Material Shield Tape Material Dielectric Material Inner Conductor Material Dimensions Cable Weight Diameter Over Dielectric Diameter Over Jacket Diameter Over Tape Inner Conductor OD Nominal Size Outer Conductor OD Electrical Specifications Cable Impedance Capacitance dc Resistance, Inner Conductor Black Non-halogenated, fire retardant polyolefin Tinned copper Aluminum Foam PE Copper-clad aluminum wire 0.07 kg/m 7.240 mm 0.285 in 10.290 mm 0.405 in 7.391 mm 0.291 in 2.7400 mm 0.1080 in 0.400 in 8.080 mm 0.318 in 50 ohm 78.0 pf/m 24.0 pf/ft 4.490 ohms/km 1.370 ohms/kft page 6 of 14
CNT-400-FR dc Resistance, Outer Conductor 5.610 ohms/km 1.710 ohms/kft dc Test Voltage 2500 V Jacket Spark Test Voltage (rms) 4000 V Maximum Frequency 16.20 GHz Operating Frequency Band 30 6000 MHz Peak Power 16.0 kw Shielding Effectiveness >90 db Velocity 85% Environmental Specifications Installation Temperature -40 C to +60 C (-40 F to +140 F) Operating Temperature -40 C to +60 C (-40 F to +140 F) Storage Temperature -40 C to +60 C (-40 F to +140 F) General Specifications Cable Type Braid Coverage Packaging Type CNT-400 90% braid Reel Mechanical Specifications Bending Moment Fire Retardancy Test Method Flat Plate Crush Strength 0.7 N-m 0.5 ft lb UL VW1/CATVX 0.7 kg/mm 40.0 lb/in Minimum Bend Radius, Single Bend 25.40 mm 1.00 in Smoke Index Test Method IEC 61034 Tensile Strength 73 kg 160 lb Toxicity Index Test Method IEC 60754-2 Electrical Performance Frequency Attenuation (db/100 m) Attenuation (db/100 ft) 30 MHz 2.49 0.76 50 MHz 3.18 0.97 150 MHz 4.92 1.50 220 MHz 6.23 1.90 450 MHz 8.86 2.70 900 MHz 12.80 3.90 1500 MHz 16.70 5.10 1800 MHz 18.40 5.60 2000 MHz 19.40 5.90 2400 MHz 21.65 6.60 2500 MHz 22.00 6.70 3000 MHz 24.60 7.50 page 7 of 14
CNT-400-FR 4000 MHz 28.87 8.80 4500 MHz 30.84 9.40 5000 MHz 32.81 10.00 5200 MHz 33.46 10.20 5500 MHz 34.78 10.60 5800 MHz 35.76 10.90 6000 MHz 36.42 11.10 Regulatory Compliance/Certifications Agency RoHS 2011/65/EU China RoHS SJ/T 11364-2006 ISO 9001:2008 Classification Compliant Below Maximum Concentration Value (MCV) Designed, manufactured and/or distributed under this quality management system page 8 of 14
400BPTM-C TNC Male for CNT-400 braided cable Product Classification Brand Product Type General Specifications Interface Body Style Electrical Specifications Operating Frequency Band Cable Impedance Connector Impedance RF Operating Voltage, maximum (vrms) dc Test Voltage Outer Contact Resistance, maximum Inner Contact Resistance, maximum Insulation Resistance, minimum Peak Power, maximum Insertion Loss, typical CNT ConQuest Braided cable connector TNC Male Straight 0 6000 MHz 50 ohm 50 ohm 500.00 V 1500 V 0.40 mohm 1.50 mohm 5000 MOhm 5.00 kw 0.05 db page 9 of 14
400BPTM-C Outline Drawing Mechanical Specifications Outer Contact Attachment Method Clamp Outer Contact Plating Trimetal Inner Contact Plating Gold Inner Contact Attachment Method Captivated Interface Durability 500 cycles Interface Durability Method IEC 61169-17:9.5 Connector Retention Tensile Force 330 N 74 lbf Connector Retention Torque 0.56 N-m 0.41 ft lb Coupling Nut Proof Torque 1.70 N-m 1.25 ft lb Coupling Nut Proof Torque Method IEC 61169-17:9.3.6 Coupling Nut Retention Force 445.00 N 100.04 lbf Coupling Nut Retention Force Method IEC 61169-17:9.3.11 Dimensions Nominal Size Diameter Length Weight 0.405 in 18.00 mm 0.71 in 41.24 mm 1.62 in 41.85 g 0.09 lb page 10 of 14
400BPTM-C Environmental Specifications Operating Temperature Storage Temperature Immersion Depth Immersion Test Mating Immersion Test Method Regulatory Compliance/Certifications -40 C to +85 C (-40 F to +185 F) -65 C to +125 C (-85 F to +257 F) 1 m Mated IEC 60529:2001, IP68 Mechanical Shock Test Method IEC 60068-2-27 Climatic Sequence Test Method IEC 60068-1 Damp Heat Steady State Test Method IEC 60068-2-3 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 C 68 F Average Power, Ambient Temperature 40 C 104 F Average Power, Inner Conductor Temperature 100 C 212 F Return Loss/VSWR Frequency Band VSWR Return Loss (db) 0 3000 MHz 1.05 33.00 3000 6000 MHz 1.17 22.00 Agency RoHS 2011/65/EU China RoHS SJ/T 11364-2006 ISO 9001:2008 Classification Compliant by Exemption Above Maximum Concentration Value (MCV) Designed, manufactured and/or distributed under this quality management system * Footnotes Immersion Depth Insertion Loss, typical Immersion at specified depth for 24 hours 0.05v freq (GHz) (not applicable for elliptical waveguide) page 11 of 14
400BPTM-C-CR TNC Male for CNT-400 braided cable Product Classification Brand Product Type General Specifications Interface Body Style Electrical Specifications Operating Frequency Band Cable Impedance Connector Impedance RF Operating Voltage, maximum (vrms) dc Test Voltage Outer Contact Resistance, maximum Inner Contact Resistance, maximum Insulation Resistance, minimum Peak Power, maximum Insertion Loss, typical CNT ConQuest Braided cable connector TNC Male Straight 0 6000 MHz 50 ohm 50 ohm 500.00 V 1500 V 0.40 mohm 1.50 mohm 5000 MOhm 5.00 kw 0.05 db page 12 of 14
400BPTM-C-CR Outline Drawing Mechanical Specifications Outer Contact Attachment Method Crimp Outer Contact Plating Trimetal Inner Contact Plating Silver Inner Contact Attachment Method Captivated Interface Durability 500 cycles Interface Durability Method IEC 61169-17:17 Connector Retention Tensile Force 330 N 74 lbf Connector Retention Torque 0.56 N-m 0.41 ft lb Coupling Nut Proof Torque 1.70 N-m 1.25 ft lb Coupling Nut Proof Torque Method IEC 61169-17:9.3.6 Coupling Nut Retention Force 445.00 N 100.04 lbf Coupling Nut Retention Force Method IEC 61169-17:9.3.11 Dimensions Nominal Size Diameter Length Weight 0.405 in 16.00 mm 0.63 in 40.74 mm 1.60 in 21.52 g 0.05 lb page 13 of 14
400BPTM-C-CR Environmental Specifications Operating Temperature Storage Temperature Water Jetting Test Mating Water Jetting Test Method Regulatory Compliance/Certifications -40 C to +85 C (-40 F to +185 F) -65 C to +125 C (-85 F to +257 F) Mated IEC 60529:2001, IP65 Mechanical Shock Test Method IEC 60068-2-27 Climatic Sequence Test Method IEC 60068-1 Damp Heat Steady State Test Method IEC 60068-2-3 Thermal Shock Test Method IEC 60068-2-14 Vibration Test Method IEC 60068-2-6 Corrosion Test Method IEC 60068-2-11 Standard Conditions Attenuation, Ambient Temperature 20 C 68 F Average Power, Ambient Temperature 40 C 104 F Average Power, Inner Conductor Temperature 100 C 212 F Return Loss/VSWR Frequency Band VSWR Return Loss (db) 0 3000 MHz 1.05 33.00 3000 6000 MHz 1.17 22.00 Agency RoHS 2011/65/EU China RoHS SJ/T 11364-2006 ISO 9001:2008 Classification Compliant by Exemption Above Maximum Concentration Value (MCV) Designed, manufactured and/or distributed under this quality management system * Footnotes Insertion Loss, typical 0.05v freq (GHz) (not applicable for elliptical waveguide) page 14 of 14