Datasheet ACT0M Signal solation and Conversion NEW High quality signal isolation and conversion in a slim wide housing format is now available with Weidmuller s ACT0M range. Features include worldwide approvals for both standard and hazardous area installations. This series of single- and dual-channel models extends Weidmuller s signal conditioning portfolio with a package of solutions for industrial process measurement and control applications. ACT0M is designed to reduce the time and cost of building control panels. DN-rail mounted in Weidmuller s new -pole housing, module power can be distributed through the rail for minimized power wiring and reduced installation costs. This Rail provides the flexibility to add or remove individual modules quickly and easily without affecting the wiring or operation of other components on the rail. The ACT0M range offers D.C. and temperature isolators and converters for use in industrial and marine applications. Configuration is simple because the ACT0M modules require no calibration. Models with selectable temperature, voltage and current ranges feature DP switches. For the Universal input model, Weidmuller provides vendorindependent, FDT-based configuration software available for download from the Weidmuller website. Features: Very high density analog signal isolation and conversion Easy installation with Rail cross-connect option DP switches for calibration-free re-ranging Universal input model uses FDT configuration software (and CBX00 interface) CE, culus, cfmus Class Div. and Class Zone ATEX, ECEx Zone, DNV, GL approvals Ambient temperature range typically - F to F (- C to 0 C) Weidmuller, Canada 0 Spy Court Markham, Ontario LR H Telephone: (00) -00 Facsimile: () 00- Email: info@weidmuller.ca Website: www.weidmuller.ca Weidmuller, Mexico Blvd. Hermanos Serdán 9, Col. San Rafael Oriente Puebla, Puebla, Mexico C.P. 09 Telephone: 0 Facsimile: 0 9 Email: clientes@weidmuller.com.mx Website: www.weidmuller.com.mx Weidmuller, United States Southlake Blvd. Richmond, Virginia Telephone: (00) 9-9 Facsimile: (0) 9-9 Email: info@weidmuller.com Website: www.weidmuller.com
ACT0M Signal solation and Conversion Universal input converter solating and converting of temperature signals and DC signals Configuration using FDT/DTM software Optional power supply via the DN-railbus way isolation ACT0M-U-AO-S, U, R N, U OUT Sensor Potentiometer/Resistance current voltage resistance, voltage resistance, current input Sensor supply current voltage Load resistance, current Load resistance, voltage voltage consumption Ambient temperature (operational) Storage temperature nsulation coordination nsulation voltage Pollution degree Overvoltage category Length x width x height Clamping range (nominal / min. / max.) Thermocouples: B, E, J, K, L, LR, N, R, S, T, U, W, W RTD: PT00, PT000, Ni0, Ni00, Ni000 // wire 0 Ω 0 k Ω 0()...0 0()...0 V, 0()... V > 0 MΩ < 0 Ω > V DC at 0 0() 0 0() 0 V < 00 Ω > 0 k Ω V DC ± 0 % 0. W ( V supply / Passive input / 0 input & output / 00 Ω load) - C 0 C -0 C C < 0. % span (DC, RTD) < 0. % CJ error (TC) < 0.0 % /K. kv 00 V culus 00-, cfmus Div., ATEX zone, ECEx Zone, DNV, GL. x. x.. / 0. /. -wire active -wire -wire V active TC n n n n ACT0M-U-AO-S U,, ϧ U, U,, ϧ U, ACT0M-U-AO-S U,, ϧ U, U,, ϧ U, Out Out Out Out V V V V Accessories Marker USB interface ACT0M-U-AO-S 00000 MF /. MC NEUTRAL 0000 CBX00 USB 90000 DN-rail bus, refer to accessories page RTD Sense R R Sense ACT0M-U-AO-S U,, ϧ U, Out V
ACT0M Signal solation and Conversion Signal splitter solating, converting and splitting DC signals Configured using DP switch Optional power supply via the DN-rail bus way isolation ACT0M-C-CO-S ACT0M-A-AO-S N OUT OUT, U N, U OUT, U OUT current voltage resistance, current input Load resistance, voltage Sensor supply current voltage Load resistance, current Load resistance, voltage voltage consumption Ambient temperature (operational) Storage temperature Cut-off-frequency nsulation coordination nsulation voltage Pollution degree Overvoltage category Length x width x height Clamping range (nominal / min. / max.) 0() 0 < Ω 0() 0 < 00 Ω / channel 0 k Ω V DC ± 0 % 0. W ( V supply / Passive input / 0 input & output / 00 Ω load) - C 0 C -0 C C < 0.0 % of measurement range < 0.0 % /K 00 Hz. kv 00 V culus 00-, cfmus Div., ATEX zone, ECEx Zone, DNV, GL. x. x.. / 0. /. ACT0M-C-CO-S 990000 0() 0 0() 0 V 0() V < Ω > 00 k Ω > V DC at 0 0() 0 0() 0 V 0() V < 00 Ω / channel > 0k Ω / channel V DC ± 0 % 0.W ( V supply / Passive input / 0 input & output / 00 Ω load) - C 0 C -0 C C < 0.0 % of measurement range < 0.0 % /K 00 Hz. kv 00 V culus 00-, cfmus Div., ATEX zone, ECEx Zone, DNV, GL. x. x.. / 0. /. ACT0M-A-AO-S 00000 Accessories Marker MF /. MC NEUTRAL 0000 MF /. MC NEUTRAL 0000 DN-rail bus, refer to accessories page DN-rail bus, refer to accessories page
ACT0M Signal solation and Conversion Converters for DC and Volts solating and converting DC signals DP switch for range changes without re-calibration Optional power supply via the DN-rail-bus way isolation Choice of active or input ( E model is not hazardous location approved) ACT0M-A-AO-S ACT0M-A-AO-E-S, U N, U OUT, U N, U OUT current voltage resistance, current input resistance, voltage Sensor supply current voltage Load resistance, current Load resistance, voltage voltage consumption Ambient temperature (operational) Storage temperature Cut-off-frequency nsulation coordination nsulation voltage Pollution degree Overvoltage category Length x width x height Clamping range (nominal / min. / max.) 0() 0 0() 0 V; 0() V < Ω > 00 k Ω > V DC at 0 0() 0 0() 0 V; 0() V < 00 Ω > 0 k Ω V DC ± 0 % 0. W ( V supply / Passive input / 0 input & output / 00 Ω load) - C 0 C -0 C C < 0.0 % of measurement range < 0.0 % /K 00 Hz. kv 00 V culus 00-, cfmus Div., ATEX zone, ECEx Zone, DNV, GL. x. x.. / 0. /. 0() 0 0() 0 V; 0() V < Ω > 00 k Ω 0() 0 0() 0 V; 0() V < 00 Ω > 0 k Ω V DC ± 0 % 0. W ( V supply / Passive input / 0 input & output / 00 Ω load) 0 C 0 C -0 C C < 0. % of measurement range < 0.0 % /K 00 Hz. kv 00 V culus 00-, DNV, GL. x. x.. / 0. /. ACT0M-A-AO-S ACT0M-A-AO-E-S -wire n U, Out V, -wire V, active n U, Out V, U, V U, V ACT0M-A-AO-S 000000 ACT0M-A-AO-E-S 00000 Accessories Marker MF /. MC NEUTRAL 0000 DN-rail bus, refer to accessories page MF /. MC NEUTRAL 0000 DN-rail bus, refer to accessories page
ACT0M Signal solation and Conversion LP and OLP isolators solation of DC signals Takes power from the input loop (LP) or output loop (OLP) Available as either single-channel or double-channel version way isolation ACT0M-C-CO-LP-S ACT0M-C-CO-OLP-S N OUT N OUT N OUT N OUT current resistance, current input current Load resistance, current consumption Ambient temperature (operational) Storage temperature Cut-off-frequency nsulation coordination nsulation voltage Pollution degree Overvoltage category Length x width x height Clamping range (nominal / min. / max.) 0() 0 < Ω at C 0() 0 < 00 Ω 0 mw per channel - from input loop - C 0 C -0 C C < 0. % of measurement range < 0.0 % /K 00 Hz. kv 00 V culus 00-, cfmus Div., ATEX zone, ECEx Zone, DNV, GL. x. x.. / 0. /. 0() 0 typ. < Ω - 0 < 00 Ω mw per channel - from output loop - C 0 C -0 C C < 0. % of measurement range < 0.0 % /K 00 Hz. kv 00 V culus 00-, cfmus Div., ATEX zone, ECEx Zone, DNV, GL. x. x.. / 0. /. ACT0M-C-CO-LP-S ACT0M-C-CO-OLP-S -wire active n Out -wire n Out active -wire active n Out -wire n Out active Single-channel version Double-channel version ACT0M C-CO-LP-S 00000 ACT0M C-CO-LP-S 00000 ACT0M- C-CO-OLP-S 00000 ACT0M-C-CO-OLP-S 00000 Accessories Marker MF /. MC NEUTRAL 0000 MF /. MC NEUTRAL 0000
ACT0M Signal solation and Conversion DC isolator solating DC signals Optional power supply via the DN-rail-bus way isolation ACT0M-C-CO-S N OUT current Load resistance, current input current Load resistance, current voltage consumption Ambient temperature (operational) Storage temperature Cut-off-frequency nsulation coordination nsulation voltage Pollution degree Overvoltage category Length x width x height Clamping range (nominal / min. / max.) 0() 0 < Ω 0() 0 < 00 Ω V DC ± 0 % 0. W ( V supply / Passive input / 0 input & output / 00 Ω load) - C 0 C -0 C C < 0.0 % of measurement range < 0.0 % span/k 00 Hz. kv 00 V culus 00-, cfmus Div., ATEX zone, ECEx Zone, DNV, GL. x. x.. / 0. /. ² -wire active n ACT0M-C-CO-S Out V ACT0M-C-CO-S 90000 Accessories Marker MF /. MC NEUTRAL 0000 DN-rail bus, refer to accessories page
ACT0M Signal solation and Conversion Temperature transmitter Choice of isolating or non-isolating converters for J or K thermocouples and RTDs. Hundreds of min/max range combinations Configuration via DP switches supplied from the output loop -way isolation (OLP-S model only) is linear with temperature ACT0M-RTC-CO-OLP-S ACT0M-RT-CO-EOLP-S PT 00 TC Optional external CJC V DC... V DC PT 00 V DC... V DC Sensor measurement range Temperature input range current Load Resistance Wire break detection Configuration voltage consumption Galvanic isolation Step response time Ambient temperature (operational) nsulation coordination nsulation voltage Pollution severity Surge voltage category Clamping range (nominal / min. / max.) Depth x width x height ² PT00 / -/-/-wire, Thermocouple acc. to EC, type: J, Thermocouple acc. to EC, type: K PT00-00 0 C, Thermocouple type J -00 00 C, Thermocouple type K -00 0 C (internal or external CJC) Selectable by DP Switch...0, 0 <00 Ω. none Selectable by DP Switch DP switch... V DC Loop powered ca. W absolute accuracy: < ±0.0 % of the measurement range, RTD (PT00) Basic accuracy: < ±0. C of the measurement range, TC (J,K) Basic accuracy: < ±0. C of the measurement range RTD (PT00) 0.0 % of the measurement range C or 0.0 C C, TC (J,K) 0. C C -way isolator 0 ms / 00 ms Selectable by DP Switch -...0 C. kv eff 00 V eff culus; FMEX; ECEXKEM; KEMAATEX; DETNORVER; GL. / 0. /.. /. /. PT00 / -/-/-wire PT00-00 0 C Selectable by DP Switch...0, 0 <00 Ω. none Selectable by DP Switch DP switch... V DC Loop powered ca. W absolute accuracy: < ±0. % of the measurement range, Basic accuracy: < ±0. C of the measurement range RTD (PT00) 0.0 % of the measurement range C or 0.0 C C Without isolation 0 ms / 00 ms Selectable by DP Switch -...0 C N/A culus; FMEX; ECEXKEM; KEMAATEX; DETNORVER; GL. / 0. /.. /. /. ACT0M-RTC-CO-OLP-S 90000 ACT0M-RT-CO-EOLP-S 0000
ACT0M Signal solation and Conversion Temperature transmitter Choice of isolating or non-isolating converters for RTDs. Hundreds of min/max range combinations Optional Rail accessory simplifies jumpering and saves wiring time. Configuration via DP switches -way isolation (AO-S model only) ACT0M-RT-AO-S ACT0M-RT-AO-E-S PT 00, V PT 00, V OUT Sensor measurement range Temperature input range current voltage load impedance current load impedance voltage Wire break detection Configuration voltage consumption Galvanic isolation Step response time Ambient temperature (operational) nsulation coordination nsulation voltage Pollution severity Surge voltage category Clamping range (nominal / min. / max.) Depth x width x height ² PT00 / -/-/-wire PT00-00 0 C Selectable by DP Switch 0...0,...0 Selectable by DP Switch 0()... V, 0()...0 V Selectable by DP Switch 00 Ω 0 kω. none Selectable by DP Switch DP switch V DC ± 0 % W absolute accuracy: < ±0.0 % of the measurement range, Basic accuracy: < ±0. % of the measurement range -way isolator 0.0 % of the measurement range C or 0.0 C C 0 ms / 00 ms Selectable by DP Switch -...0 C. kv eff 00 V eff culus; FMEX; ECEXKEM; KEMAATEX; DETNORVER; GL. / 0. /.. /. /. PT00 / -/-/-wire PT00-00 0 C Selectable by DP Switch 0...0,...0 Selectable by DP Switch 0()... V, 0()...0 V Selectable by DP Switch 00 Ω 0 kω. none Selectable by DP Switch DP switch V DC ± 0 % W absolute accuracy: < ±0. % of the measurement range Without isolation 0.0 % of the measurement range C or 0.0 C C 0 ms / 00 ms Selectable by DP Switch -...0 C N/A N/A culus; FMEX; ECEXKEM; KEMAATEX; DETNORVER; GL. / 0. /.. /. /. ACT0M-RT-AO-S 0000 ACT0M-RT-AO-E-S 0000
ACT0M Signal solation and Conversion Temperature transmitter Choice of isolating or non-isolating converters for J or K thermocouples Hundreds of min/max range combinations Optional Rail accessory simplifies jumpering and saves wiring time. Configuration via DP switches -way isolation (AO-S model only) ACT0M-TC-AO-S ACT0M-TC-AO-E-S Optional external CJC TC, V Optional external CJC TC, V OUT Sensor measurement range Temperature input range current voltage load impedance current load impedance voltage Wire break detection Configuration voltage consumption Galvanic isolation Step response time Ambient temperature (operational) nsulation coordination nsulation voltage Pollution severity Surge voltage category Clamping range (nominal / min. / max.) Depth x width x height ² Thermocouple (Type J, K) Thermocouple type J -00 00 C, Thermocouple type K -00 0 C (internal or external CJC) Selectable by DP Switch 0...0,...0 Selectable by DP Switch 0()... V, 0()...0 V Selectable by DP Switch 00 Ω 0 kω. none Selectable by DP Switch DP switch V DC ± 0 % ca. W absolute accuracy: < ±0.0 % of the measurement range, TC (J,K) Basic accuracy: < ±0. C of the measurement range -way isolator < 0. % / C 0 ms / 00 ms Selectable by DP Switch -...0 C. kv eff 00 V eff culus; FMEX; ECEXKEM; KEMAATEX; DETNORVER; GL. / 0. /.. /. /. Thermocouple (Type J, K) Thermocouple type J -00 00 C, Thermocouple type K -00 0 C (internal or external CJC) Selectable by DP Switch 0...0,...0 Selectable by DP Switch 0()... V, 0()...0 V Selectable by DP Switch 00 Ω 0 kω. none Selectable by DP Switch DP switch V DC ± 0 % ca. W absolute accuracy: < ±0. % of the measurement range, Basic accuracy: < ± C Without isolation 0.0 % / C 0 ms / 00 ms Selectable by DP Switch -...0 C N/A N/A culus; FMEX; ECEXKEM; KEMAATEX; DETNORVER; GL. / 0. /.. /. /. ACT0M-TC-AO-S 0000 ACT0M-TC-AO-E-S 00000 9
ACT0M Signal solation and Conversion Bipolar converters ACT0M-BA-AO-S For use with center-zero sensors, e.g. actuator position control, or bi-directional flow monitoring. DP switches simplify configuration Conversion choices: bipolar in/unipolar out, or bipolar in/x unipolar out. Optional Rail accessory simplifies jumpering and saves wiring time. ACT0M-BA-AO-S current voltage resistance, voltage resistance, current inputs Cut-off frequency (- db) load impedance voltage Number of outputs load impedance current voltage, note current Configuration Galvanic isolation Mounting rail consumption consumption, max. Step response time voltage Type of connection nsulation coordination EMC standards Galvanic isolation nsulation voltage Pollution severity Standards Surge voltage category ROHS Depth x width x height () ±, ± V N, V OUT -0 0 0, -0 0 0 - V 0 V, -0 V 0 0 V Selectable by DP Switch MΩ 0 Ω at 0 00 Hz, 0 Hz Selectable by DP Switch 0 kω 00 Ω 0()...0 V, 0()... V Selectable by DP Switch 0...0,...0 Selectable by DP Switch < 0.0 % of measuring range DP switch -way isolator; TS Typ. 00 mw 0. W ms, 00 ms, Selectable by DP Switch V DC ± 0 % < 0.0% of span/ C (TU) Screw connection EN - -way isolator;. kv eff 00 V eff DN EN 00-, DN EN 009 culus, DNV, FM, ECEx, Ex Conform. x. x. ACT0M-BA-AO-S 0000 ±, ± V N OUT, V, V OUT -0 0 0, -0 0 0 - V 0 V, -0 V 0 0 V Selectable by DP Switch MΩ 0 Ω at 0 00 Hz, 0 Hz Selectable by DP Switch 0 kω x 00 Ω 0()...0 V, 0()... V Selectable by DP Switch 0...0,...0 Selectable by DP Switch < 0.0 % of measuring range DP switch -way isolator; TS Typ. 00 mw 0. W ms, 00 ms, Selectable by DP Switch V DC ± 0 % < 0.0% of span/ C (TU) Screw connection EN - -way isolator;. kv eff 00 V eff DN EN 00-, DN EN 009 culus, DNV, FM, ECEx, Ex Conform. x. x. ACT0M-BA-AO-S 0000 0
ACT0M Signal solation and Conversion Rail bus accessories CH0M BUS-PROFL TSx./000 Support section for bus PCB CH0M BUS-PROFL TSx/000 Support section for bus PCB CH0M BUS.0/0 AU/000 Bus PCB Support section for TS x. Length: 0, 00 or 0 CH0M BUS-PROFL TSx./0 0 0000 CH0M BUS-PROFL TSx./00 0 0000 CH0M BUS-PROFL TSx./0 0000 Support section for TS x Length: 0, 00 or 0 CH0M BUS-PROFL TSx/0 0000 CH0M BUS-PROFL TSx/00 90000 CH0M BUS-PROFL TSx/0 0000 Bus PCB for use on TS x. and TS x Length: 0, 00 or 0 Five conductor paths, gold plated Electrical rating: V AC, A/conductor path CH0M BUS.0/ 0 AU/0 0 0000 CH0M BUS.0/ 0 AU/00 0 0000 CH0M BUS.0/ 0 AU/0 0000 CH0M BUS-ADP TS/000 Cover plate CH0M BUS-AP L TSx. & End plate CH0M BUS-AP RE TSx. & End plate Cover plate for rail bus Length: 0, 00 or 0 CH0M BUS-ADP TS/0 0 0000 CH0M BUS-ADP TS/00 0 0000 CH0M BUS-ADP TS/0 0000 End plate for rail bus Fits on TS x. and TS x Left CH0M BUS-AP L TSx. & 0 90000 End plate for rail bus Fits on TS x. and TS x Right CH0M BUS-AP RE TSx. & 0 90000 SET CH0M BUS 0MM TS X Set SET CH0M BUS 0MM TS X. Set SET consists of one each of CH0M BUS.0/0 AU/0 CH0M BUS-ADP TS /0 CH0M BUS-AP L TS X. & CH0M BUS-AP RE TS X. & CH0M BUS-PROFL TS X/0 SET CH0M BUS 0MM TS X 0000 SET consists of one each of CH0M BUS.0/0 AU/0 CH0M BUS-ADP TS /0 CH0M BUS-AP L TS X. & CH0M BUS-AP RE TS X. & CH0M BUS-PROFL TS X./0 SET CH0M BUS 0MM TS X. 0000
ACT0M Signal solation and Conversion -current loop-powered Galvanic isolation Very low power consumption range selected via DP switch No calibration necessary OLP UL Class, Div. U/ voltage resistance, voltage/current current Rated current current signal limit Load impedance, voltage/current Cut-off frequency (- db) Configuration voltage Ambient temperature Default setting Step response time nsulation coordination Standards EMC standards mpulse withstand voltage nsulation voltage Surge voltage category Pollution severity Clearance & creepage distances Clamping range (nominal / min. / max.) Length x width x height ² 0...V: 0 kω; 0...0V: 0 kω / Ω 0()...0 0...0 (current loop) Approx. / R L = (U B - V) / 0 z.b. 00 Ω at V 0 Hz/ 00 Hz switchable DP switch min. V DC/ max. 0 V DC 0 C... C 0...0, 0 Hz 0.% of measuring range final value 0 ppm/k < 0 Hz: 0 ms; 00 Hz: 0 ms CE; culus DN EN 0, DN EN 000-- EN 0, EN 000-00 V kv kv eff / s.. / 0. /. 9. /. /. Setting options/switch position SW 0 0 n n n n 0 n n n 0 V n 0 0 V n n n Transmission frequency 0 Hz n n n 00 Hz n n n n = on n = off Example of application Sensor ~ 0 V AC V DC 0...0V WAVE ANALOGUE OLP 0000/0000 V DC 0 V AC 9 ~... 0 Screw connection WAS OLP 0000 R L SPS
ACT0M Signal solation and Conversion Thermal converter type: K,J,T,E,N,R,S,B -way isolation nternal cold-junction compensation supply can be cross-connected using plug-in jumpers Suitable for insulated and uninsulated thermocouples WAVETOOL software helps with configuration, download at www.weidmuller.com J V C U/ Sensor Temperature input range voltage / current Load impedance, voltage/current Offset current / Offset voltage Line resistance in measuring circuit Wire break detection Fine adjustment Status indicator Configuration voltage consumption Step response time Current-carrying capacity of cross-connect. Ambient temperature Storage temperature Default setting nsulation coordination Standards EMC standards mpulse withstand voltage nsulation voltage Surge voltage category Pollution severity Clearance & creepage distances Clamping range (nominal / min. / max.) Length x width x height ² Screw connection PRO Thermo UL Class, Div. Thermo element (EC ) type: K,J,T,E,N,R,S,B -00...0 C 0...0 V / 0()...0 kω / 00 Ω max. 00 µa / max. 0.0 V 0 Ω LED flashing (output value: > 0, >0 V) ± % (switchable) Module active: LED on/ wire breakage: LED flashing/ Error: LED off DP switch V DC ± % 00...0...90 mw at OUT = 0 without filter: max.. s; with filter: max.. s A 0 C... C -0 C... C Type K; 0...000 C;...0; filter: off; man. calibration: off CE; culusex; GL DN EN 0, DN EN 000-- EN 0, EN 000-00 kv kv eff / s. / 0. /. 9. /. /. WAS PRO Thermo 00000 Select of thermocoupler SW Typ K J T E N R S B Selection of temperature span SW Span 00 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 900 C 90 C 000 C 00 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C 00 C 00 C 00 C Selection of minimum temperature SW ϑ min 0 C 0 C 0 C 0 C 0 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C 0 C 00 C Special range Selection of output Switch 0... 0 V 0... 0 V... 0 V Switching on the manual fine adjustment man. SW adjust. off on Switching on the filter function SW Filter off on K -00 C -0 C ± (K 0. % of set range) -0 C 00 C ± (K 0. % of set range) 00 C C ± (K 0. % of set range) J -00 C -0 C ± (K 0. % of set range) -0 C 00 C ± (K 0. % of set range) T -00 C -0 C ± (K 0. % of set range) -0 C 00 C ± (K 0. % of set range) E -00 C -0 C ± (K 0. % of set range) -0 C 000 C ± (K 0. % of set range) N -00 C -0 C ± (K 0. % of set range) -0 C 00 C ± (K 0. % of set range) R -0 C 00 C ± (0K 0. % of set range) 00 C 0 C ± (K 0. % of set range) S -0 C 00 C ± (0K 0. % of set range) 00 C 0 C ± (K 0. % of set range) B 0 C 0 C ± (K 0. % of set range) 0 C 00 C ± (0K 0. % of set range) 00 C 0 C ± (K 0. % of set range) = on = off
ACT0M Signal solation and Conversion RTD signal isolator/converter Universally adjustable via DP switch -way isolation Linearisation supply can be cross-connected using plug-in jumpers WAVETOOL software helps with configuration,download at www.weidmuller.com PRO RTD UL Class, Div. RTD J,R U/ V C Sensor Temperature input range current / voltage Offset current / Offset voltage Load impedance, voltage/current Wire break detection Fine adjustment Status indicator Configuration voltage consumption Step response time Ambient temperature nsulation coordination Standards EMC standards mpulse withstand voltage nsulation voltage Surge voltage category Pollution severity Clearance & creepage distances Clamping range (nominal / min. / max.) Length x width x height ² PT00/-/-/-wire, Ni00/-/-/-wire, potentiometer: min. 000 Ω, max. 000 kω, Resistance: 00 Ω configurable 0()...0 / 0...0 V max. 00 µa / max. 0.0 V kω / 00 Ω LED flashing (output value: > 0, >0 V) ± %, Version and later:. % / potentiometer:.%...% Module active: LED on/ wire breakage: LED flashing/ Error: LED off DP switch, Potentiometer V DC ± % 0...0...90mW at OUT = 0 fast/slow: -/-/-conductor:. s/. s; potentiometer: 0. s/. s 0 C... C CE; culus; GL DN EN 0, DN EN 000-- EN 0, EN 000-00 V kv kv eff / s. / 0. /. 9. /. /. Screw connection WAS PRO RTD 000000
ACT0M Signal solation and Conversion PRO RTD Switch position / setting options Choice of inputs Switch PT00 -wire PT00 -wire PT00 -wire R -wire N00 -wire N00 -wire N00 -wire Potentiometer = on = off Choice of minimum input size Switch ϑ min R min Poti min 0 C 0 Ω 0 % -0 C 0 Ω 0 % -0 C 0 Ω 0 % - C 0 Ω % -0 C 0 Ω 0 % -0 C 0 Ω 0 % -0 C 0 Ω 0 % -0 C 0 Ω 0 % -0 C 0 Ω 0 % -0 C 0 Ω 0 % -90 C 90 Ω -00 C 00 Ω -0 C 0 Ω -00 C 00 Ω Special area Choice of measuring range Switch T R Poti 0 K 0 Ω 0 % 0 K Ω % 0 K 0 Ω 0 % 0 K Ω % 0 K 0 Ω 0 % 90 K Ω % 00 K 0 Ω 0 % 0 K Ω % 0 K 0 Ω 0 % K, Ω, % 0 K Ω % 0 K 0 Ω 0 % 0 K Ω % 0 K 0 Ω 0 % 0 K Ω % 0 K 90 Ω 90 % 90 K 9 Ω 9 % 00 K 00 Ω 00 % 0 K Ω --- 00 K 0 Ω --- 0 K Ω --- 00 K 00 Ω --- 0 K Ω --- 00 K 0 Ω --- 0 K Ω --- 00 K 00 Ω --- 0 K Ω --- 00 K 0 Ω --- 0 K Ω --- 00 K 00 Ω --- 0 K Ω --- 900 K 0 Ω --- Choice of outputs Switch on the manual fine Switch adjustments S. 0...0 V Man. adjustment 0... V off 0...0 on...0 Choice of step response time S. Step response time slow fast, slow/fast step response time PT 00,Ni 00: 0, % from measuring range 0, % from measuring range < 00 K / 0, K / 0, K Potentiometer: 0. % from end value / 0. % Resistance: 0. % from end value / 0. % Measuring range 00 K 00 ppm / C 00 K Measuring range < 00 K 0 ppm / C 0 K Measuring range < 00 K 00 ppm / C Adjustment example for zero and span Temperature adjustment: 0 DP switch -0 C 0 C Span 0 C Range 0 C Adjustment range ±. % C 0 C C C Zero Span Wavetool adjustment tool This service tool enables quick and straightforward configuration of the WAVEANALOG PRO. nternet download: http://www.weidmuller.com 9 C 0 C C 0 C C 0 C
ACT0M Signal solation and Conversion ACT0 power feed module Distributes the voltage supply on the busbar Compatible with Weidmuller s CH0 rail bus Optional backup supply connection Approved for installation in Ex Zone /Div. Monitors the supply voltage Alarm alerts via the status relay ACT0M-FEED-N-PRO-S ACT0-FEED-N-BASC-S Alarm supply, 0 V supply, V Backup, V Backup, 0 V NC Status relay, N.C. Status relay, shared Status relay, N.O. supply, V supply, 0 V NC NC 0 V V Status NC NC 0 V V NC supply Max. input current Backup power supply Trigger level for the power supply, power supply voltage power current, status relay in safe zone Max. voltage Max. current Max. AC power Efficiency degree Ambient temperature Storage temperature consumption Protection degree Weight Humidity Clamping range (nominal / min. / max.) Length x width x height... V DC A... V DC Fault < V DC voltage -0. V DC @ A max. 9 W max. A 0 AC / 0 V DC A AC / A DC 00 VA / 0 W > 9.9 % -0...0 C -0... C < W P0 0 g < 9 %, no condensation culus, cfmus, ATEX, ECEx Zone, DNV, GOST Screw connection. / 0. /. 9. /. /. ACT0-Feed-n-PRO-S 900000... V DC.A = U input = P input = input 00 % -...0 C -0... C < W P0 0 g < 9 %, no condensation culus, ATEX, ECEx Zone, GL, DNV, cfmus, GOST Screw connection. / 0. /.. /. /. ACT0-FEED-N-BASC-S 900000 Subject to technical changes 0/ LT