PERFORMANCE SPECIFICATION SHEET

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

DEFENSE LOGISTICS AGENCY DLA LAND AND MARITIME POST OFFICE BOX 3990 COLUMBUS, OH

DEFENSE LOGISTICS AGENCY LAND AND MARITIME P.O. BOX 3990 COLUMBUS, OHIO

PERFORMANCE SPECIFICATION SHEET SWITCH, ASSEMBLIES, SENSITIVE, TRIGGER, 7 AMPERES, UNSEALED

MILITARY SPECIFICATION SHEET COILS, RADIO FREQUENCY, MOLDED, ENCAPSULATED, VARIABLE, MICRO-MINIATURE, IRON CORE, TYPES LT11V001 TO LT11V021 INCL.

FIGURE 1. Design, dimensions, and circuit diagram.

DETAIL SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, 10 AMPERES, 2 PDT TYPE I, MAGNETIC LATCH, STUD MOUNTED, SOLDER HOOKS, HERMETICALLY SEALED

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET TRANSFORMERS, AUDIO FREQUENCY, MICRO-MINIATURE

PERFORMANCE SPECIFICATION SHEET SWITCHES, PUSH, 10 AMPERES OR LOW LEVEL, DUSTTIGHT

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

MILITARY SPECIFICATION SHEET TRANSFORMER, POWER, STEP-DOWN, AUTOTRANSFORMER. Inactive for new design after 13 March 1991

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET SWITCH, SENSITIVE, LIMIT, HERMETIC SEAL

This specification is approved for use by all Departments and Agencies of the Department of Defense. Dimensions

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET MICROPHONE ASSEMBLY AND MICROPHONE, DYNAMIC, M26542/9-01 AND M-133/U

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET CONNECTOR, PLUG, ELECTRICAL, TRIAXIAL, RADIO FREQUENCY (SERIES TRB, PIN CONTACT, CLASS 2)

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET FUSES, INSTRUMENT, POWER, AND TELEPHONE (NONINDICATING), STYLE F03

PERFORMANCE SPECIFICATION SHEET TRANSFORMERS, AUDIO FREQUENCY

PERFORMANCE SPECIFICATION TRANSFORMERS, AUDIO FREQUENCY

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET SOCKETS AND ACCESSORIES FOR PLUG-IN ELECTRONIC COMPONENTS (ELECTRON TUBE, BOTTOM MOUNTING, SADDLE TYPE 8 CONTACT, RADIAL)

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, RADIATION COUNTER TYPE 8767

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE 8943

DETAIL SPECIFICATION SHEET

This specification is approved for use by all Departments and Agencies of the Department of Defense.

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET

The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-DTL

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 75 OHMS, M17/6-RG11 UNARMORED, M17/6-RG12 ARMORED

DETAIL SPECIFICATION SHEET CONNECTORS AND ASSEMBLIES, ELECTRICAL, AIRCRAFT GROUNDING: PLUGS, FOR TYPES I AND II GROUNDING ASSEMBLIES

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/28-RG058

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/60-RG142.

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/75-RG214 AND M17/75-RG365

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 303, DC RESISTANCE

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, NEGATIVE GRID (MICROWAVE) TYPE 8727

DETAIL SPECIFICATION SHEET

HEADSET-MICROPHONE H-161F/GR. Inactive for new design after xxx xx, 2012

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, SEMIRIGID, COAXIAL, SEMI-AIR-DIELECTRIC,.875 TO INCHES OUTSIDE DIAMETER, 50 OHMS

DEFENSE LOGISTICS AGENCY LAND AND MARITIME P.O. BOX 3990 COLUMBUS, OHIO

DETAIL SPECIFICATION SHEET CABLES, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, UNARMORED M17/74-RG213, AND ARMORED M17/74-RG215

MAGNETIC-LATCHING DPDT HALF-SIZE CRYSTAL CAN HIGH POWER RF RELAY DC-3 GHZ

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, RECTANGULAR, PLUG, MICROMINIATURE, POLARIZED SHELL, PIN CONTACTS, CLASS M, CRIMP TYPE

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPE 8660

DETAIL SPECIFICATION SHEET INSERT, SCREW THREAD, LOCKED IN, KEY-LOCKED, MINIATURE AND LIGHTWEIGHT

DETAIL SPECIFICATION SHEET CONNECTORS, PLUG, ELECTRICAL, CRIMP TYPE, CABLE-CONNECTING, BAYONET COUPLING, SERIES 1, CLASSES E, F AND P

DETAIL SPECIFICATION SHEET

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, POWER TYPES 7203 AND 7203A

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CABLE, SPECIAL PURPOSE, ELECTRICAL, TWELVE INDIVIDUALLY SHIELDED PAIRS 22 (7 X 30) AWG

PERFORMANCE SPECIFICATION SHEET ELECTRON TUBE, MAGNETRON TYPE DOD-011

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 311, LIFE, LOW LEVEL SWITCHING

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 204, VIBRATION, HIGH FREQUENCY

DETAIL SPECIFICATION SHEET HINGE, BUTT STRUCTURAL, EXTRUDED

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, MODULAR, TYPE IV, CONNECTOR, 200 CONTACT, CENTER

DETAIL SPECIFICATION SHEET TERMINAL, WIRE ROPE, SWAGING, FORK END

PERFORMANCE SPECIFICATION SHEET TRANSISTOR, NPN, SILICON, POWER, TYPES 2N6274 AND 2N6277, JAN, JANTX, AND JANTXV

COMMERCIAL ITEM DESCRIPTION SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET SWITCH, TOGGLE, SPST, AND SPDT, 24 VOLT DC, 25 AMPERE (WATERPROOF)

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 201, VIBRATION

Table of Contents. Kilovac Time Delay Relays

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, FLANGE MOUNTING, MINIATURE, CLASSES E, F, G AND R

The requirements for acquiring the product described herein shall consist of this specification sheet and MIL-PRF

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 307, CONTACT RESISTANCE

DETAIL SPECIFICATION SHEET CONNECTORS, ELECTRICAL, RECTANGULAR, PLUG, MICROMINIATURE, POLARIZED SHELL, PIN CONTACTS, CLASS M, SOLDER TYPE

DETAIL SPECIFICATION SHEET SHACKLE, ANCHOR, FORGER CARBON STEEL SCREW PIN. Inactive for new design after 16 June 1997, For new design, use RR-C-271.

DEPARTMENT OF DEFENSE TEST METHOD STANDARD METHOD 213, SHOCK (SPECIFIED PULSE)

MILITARY SPECIFICATION SHEET CABLE, RADIO FREQUENCY, FLEXIBLE, COAXIAL, 50 OHMS, M17/

PERFORMANCE SPECIFICATION SHEET

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET FITTINGS, PIPE, CAST BRONZE, SILVER-BRAZING; REDUCING COUPLING, BUSHING, AND ADAPTER, PIPE

PERFORMANCE SPECIFICATION SHEET

DETAIL SPECIFICATION SHEET CONNECTORS, RECEPTACLE, ELECTRICAL, SINGLE HOLE MOUNT, MINIATURE, CLASSES E, F, G, H AND R

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19

Transcription:

DEFENSE LOGISTICS AGENCY DLA Land and Maritime POST OFFICE BOX 3990 COLUMBUS, OH 43218-3990 23 August 2018 MEMORANDUM FOR MILITARY/INDUSTRY DISTRIBUTION SUBJECT: Initial Draft of MIL-PRF-39016/54E. Project number 5945-2018-044. The draft of the above subject document is being sent to you for review and comments. The draft consists of the following changes: Revised document to include the following changes: Revised document to include the following MIL-STD-961 updates: insert QR Code, clarify reference to MIL-STD-202 to include test methods 204, 214, and 213, change Air Force 11 code to 85, update Changes from previous revision paragraph, and update NOTE paragraph. If the document is of interest to you, please provide your comments electronically. This can be in the form of a return e-mail, with or without an attached text file. A 30-day coordination cycle from the date of this letter has been allotted. Please provide your comments within that time period. If no comments are received in the allotted 30 day coordination cycle, concurrence is assumed and all comments received after will be held to the first amendment. Since Navy-EC is a custodian for this document; all Navy review activities should forward their comments directly to this Center. If an electronic response is not possible we will still accept comments via letter, facsimile or phone call but only after you have contacted the project officer listed below. The draft document can be found at the following DLA LAND AND MARITIME-VA web page: https://landandmaritimeapps.dla.mil/programs/milspec/initialdrafts.aspx This process still requires military departments to identify their comments as Essential or Suggested. Essential comments must be justified with supporting data. Military review activities should forward comments to their custodians or this office, as applicable, in sufficient time to allow for consolidating the department reply. If there are any questions, please contact Erika Baker by the preferred method of E-Mail at Erika.Baker@dla.mil or by telephone at commercial 614-692-4481, DSN 850-4481; or by facsimile at 614-692-6939. Our mailing address as a last resort is DLA Land and Maritime-VAT, P.O. Box 3990, Columbus, OH 43218-3990. If you have further questions or concerns you may contact me at Michael.Radecki@dla.mil by telephone at 614-692-0561 or by DSN 850-0561. RADECKI.MICHAE Digitally signed by RADECKI.MICHAEL.A.1230152051 L.A.1230152051 Date: 2018.08.23 10:54:52-04'00' MICHAEL A. RADECKI Chief Electronic Components Branch

NOTE: This draft, dated 23 August, 2018 prepared by DLA-CC has not been approved and is subject to modification. DO NOT USE FOR ACQUISITION PURPOSES. (Project # 5945-2018-044) INCH-POUND MIL-PRF-39016/54E DRAFT SUPERSEDING MIL-PRF-39016/54D 19 September 2006 PERFORMANCE SPECIFICATION SHEET RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, HERMETICALLY SEALED, 4PDT, LOW LEVEL TO 2 AMPERES (.150-INCH TERMINAL SPACING) WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION AND REVERSE POLARITY PROTECTION This specification sheet is approved for use by all Departments and Agencies of the Department of Defense. The complete requirements for acquiring the relays described herein shall consist of this specification sheet and the latest issue of MIL-PRF-39016. FIGURE 1. Configuration and circuit diagram. AMSC N/A FSC 5945

MIL-PRF-39016/54E Inches mm Inches mm.001 0.03.100 2.54.002 0.05.150 3.81.003 0.08.187 4.75.005 0.13.300 7.62.015 0.38.320 8.13.020 0.51.450 11.43.030 0.76.500 12.70.050 1.27.610 15.49.080 2.03.850 21.59.094 2.39 1.062 26.97.096 2.44 NOTES: 1. Dimensions are in inches. 2. Metric equivalents are given for general information only. 3. Unless otherwise specified, tolerance is ±.010 (0.25 mm). 4. Terminal locating dimensions shown are applicable to all type mounts. 5. Terminal numbers in circuit diagram are for reference only. Numbers do not appear on relay. 6. Indicated terminal shall be identified with contrasting bead. 7. The shape of lug terminals is optional. 8. Coil symbol is optional per MIL-STD-1285. 9. Finish: Finish shall provide the operational, environmental, and interface characteristics to provide a reliable interconnect to gold plated contacts. One system for gold plating that may be used is ASTM B488, type 3, class 1.25, knoop hardness shall be a minimum of 200 to 240, nickel underplate 50 to 150 microinches thick. The gold plating shall enable the product to meet the performance requirements of this specification and shall be approved by the qualifying activity. FIGURE 1. Configuration and circuit diagram - Continued. 2

REQUIREMENTS: MIL-PRF-39016/54E CONTACT DATA: Load ratings: High level (relay case grounded): Resistive: 2.0 ampere at 28 V dc; 0.125 ampere at 115 V ac, (60 and 400 Hz); 0.5 ampere at 115 V ac, (60 and 400 Hz) with case not grounded. Inductive: 0. 5 ampere at 200 millihenries inductive at 28 V dc. Lamp: 0.10 ampere at 28 V dc. Low level: 10 µa to 50 µa at 10 mv to 50 mv dc or peak ac. Intermediate current: Applicable. Contact resistance or voltage drop: Initial: 0.050 ohm maximum. High level: During life: Not more than 5 percent of open circuit voltage. After life: 0.150 ohm maximum. Low level: During life: 33 ohms maximum. After life: 0.150 ohm maximum. Intermediate current: During intermediate current: 1 ohm maximum. After intermediate current: 3 ohms maximum. Contact bounce: 2.0 milliseconds (ms) maximum. (Applicable to failure rate level L ). Contact stabilization time: 2.5 milliseconds (ms) maximum. (Applicable to failure rate levels M, P, and R ). Overload (high level only): 4 amperes resistive at 28 V dc, 1.0 ampere inductive at 28 V dc. (AC not applicable). COIL DATA: See table I. Operate time: 4.0 ms maximum over temperature range with rated coil voltage. Release time: 6.0 ms maximum over temperature range from rated coil voltage. 3

ELECTRICAL DATA: MIL-PRF-39016/54E Insulation resistance: 1/ 10,000 megohms minimum, except the resistance between coil and case at high temperature shall be 1,000 megohms minimum. Dielectric withstanding voltage: 1/ Sea level V rms (60 Hz) Altitude V rms (60 Hz) Between case, frame, or enclosure, and between all contacts in the energized and de-energized position 750 350 Between case, frame, or enclosure and coil(s) 500 Between all contacts and coil(s) 750 Between open contacts in the energized and de-energized positions 500 Between contact poles 750 DIODE CHARACTERISTICS: 2/ Maximum negative transient: 1.0 V. Breakdown voltage: 100 V dc at 10 microamperes (µa). Maximum leakage current: 1 µa at 50 V dc. Coil transient suppression: Applicable. All terminals to case Semiconductor in process screening: Applicable, visual inspection of semiconductors shall be in accordance with MIL-STD-750, method 2074. ENVIRONMENTAL DATA: Temperature range: -65 C to +125 C. Vibration (sinusoidal): MIL-STD-202-204. Contact chatter shall not exceed 10 microseconds maximum for closed contacts and 1 microsecond maximum closure for open contacts. Vibration (random): MIL-STD-202-214, test condition IG. Contact chatter shall not exceed 10 microseconds maximum for closed contacts, and 1 microsecond maximum closure for open contacts (applicable to qualification and group C testing only). Shock (specified pulse): MIL-STD-202-213, test condition C (100 g s). Contact chatter shall not exceed 10 µs maximum for closed contacts, and 1 µs maximum closure for open contacts. 1/ Insulation resistance and dielectric with standing voltage tests shall always precede all other specified measurements. Connect all coil terminals together to avoid damage to the diodes. 2/ In all tables relating to qualification testing and group A testing, delete coil resistance and substitute the following test: Diode breakdown and block integrity with applicable voltage applied to the relay coil circuit in the reverse direction, monitor leakage current with dc microammeter or reverse direction, monitor leakage current with dc microammeter or oscilloscope. Leakage current shall not exceed the specified. 4

MIL-PRF-39016/54E Magnetic interference: Applicable. Resistance to soldering heat: Applicable. Acceleration: Applicable. PHYSICAL: Terminals: See figure 1 and table I. Terminal strength: 1.5 ±0.2 pounds (pull). Solderability: Applicable (except to gold plated terminals). Terminal twist test: Applicable to wire leads. Dimensions and configurations: See figure 1 and table I. Weight: 8.5 grams (0.30 ounce) maximum. Identification marking (full): Applicable. LIFE TEST REQUIREMENTS: High level: 100,000 cycles. Low level: 100,000 cycles plus 900,000 cycles mechanical life. PART NUMBER: M39016/54 - (dash number from table I and suffix letter designation failure rate level). 5

MIL-PRF-39016/54E TABLE I. Dash number and characteristics. 1/ Dash number 2/ 001 002 015 016 003 004 017 018 005 006 019 020 007 008 021 022 009 010 023 024 011 012 025 026 013 014 027 028 Mount Leads Coil voltage V dc 3/ Rated Max Coil resistance (Ref only) Ohms ±10% Max. Coil Current (ma) Min. Coil Current (ma) At 25 C pickup V dc hold dropout Over temperature range pickup hold dropout 6 7 28 218.25 162.34 3.7 2.3 0.5 4.8 2.9 0.4 9 11 73 129.38 99.63 5.2 3.2 0.6 6.6 4.1 0.5 12 14 115 111.11 86.96 6.4 3.9 0.8 8.6 5.0 0.6 18 22 280 69.44 55.19 9.4 5.7 1.0 12.2 7.4 0.7 22 27 430 55.56 44.40 11.3 6.7 1.2 15.0 8.7 0.8 26.5 35 720 40.12 32.20 14.5 8.8 1.7 19.0 11.5 1.1 36 42 1,040 37.93 30.59 18.1 11.1 2.1 23.8 15.0 1.3 1/ Each relay possesses high level and low level capabilities. However, relays previously tested or used above 10 ma resistive at 6 V dc maximum or peak ac open circuits not recommended for subsequent use in low level applications. 2/ The suffix letter L, M, P, or R to designate the applicable failure rate level shall be added to the applicable listed dash number. Failure rate level (percent per 10,000 cycles): L, 3.0; M, 1.0; P, 0.1; R, 0.01. EXAMPLE, 001L- - - - - - - - -003R. 3/ CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. 4/ Coil resistance not directly measurable at relay terminals. When rated voltage is applied to the coil terminals, the coil circuit current shall be within the limits shown. Measure at 25 C at nominal voltage for 5 seconds maximum. 6

QUALIFICATION INSPECTION: MIL-PRF-39016/54E Qualification inspection and sample size: See table II. TABLE II. Qualification inspection and sample size. 1/ Single submission Group submission 22 units plus 1 open unit. level L at C = 0 1/ M39016/54-011 22 units plus 1 open unit. level L at C = 0 1/ 33 units plus 1 open unit. level M at C = 0 1/ Qualification inspection as applicable 33 units plus 1 open unit. level M at C = 0 1/ Qualification inspection as applicable. M39016/54-001 2 units, each PIN, M39016/54-003 qualification inspection M39016/54-007 table, Q1. M39016/54-009 M39016/54-013 M39016/54-006 M39016/54-026 2 units, qualification inspection table, Q1, and shock, vibration, acceleration, terminal strength, and seal. 1/ The number of units required for qualification testing will be increased as required in Q5, table II, MIL-PRF-39016, if the relay manufacturer elects to test the number of units permitting one or more failures. Prior to performance of qualification inspection testing, the relay manufacturer shall preselect the sample size. Referenced documents. In addition to MIL-PRF-39016, this document references the following: MIL-STD-202-204 MIL-STD-202-214 MIL-STD-202-213 MIL-STD-750 MIL-STD-1285 ASTM-B488 Changes from previous issue: The margins of this specification are marked with vertical lines to indicate where changes from the previous issue were made. This was done as a convenience only and the Government assumes no liability whatsoever for any inaccuracies in these notations. Bidders and contractors are cautioned to evaluate the requirements of this document based on the entire content irrespective of the marginal notations and relationship to the previous issue. Custodians: Army - CR Navy - EC Air Force - 85 DLA - CC Preparing activity: DLA - CC Review activities: (Project 5945-2018-044) Army - AR Navy - AS, MC, OS, SH Air Force - 19 NOTE: The activities listed above were interested in this document as of the date of this document. Since organizations and responsibilities can change, you should verify the currency of the information above using the ASSIST Online database at https://assist.dla.mil/. 7