ABSTRACTS of SESSION 6

Similar documents
PREVENTING FLASHOVER NEAR A SUBSTATION BY INSTALLING LINE SURGE ARRESTERS

Analysis of lightning performance of 132KV transmission line by application of surge arresters

Session Four: Practical Insulation Co-ordination for Lightning Induced Overvoltages

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

Lightning performance of a HV/MV substation

APPLICATION OF LONG FLASHOVER ARRESTERS FOR IMPROVEMENT OF LIGHTNING PROTECTION AND OPERATING VOLTAGE RELIABILITY OF DISTRIBUTION LINES

The line-lightning performance and mitigation studies of shielded steelstructure

Earthing of Electrical Devices and Safety

Modeling insulation in high-voltage substations

MODIFICATION OF THE ARRESTER ARRANGEMENT WHEN CONVERTING THE METHOD OF NEUTRAL TREATMENT

Simplified Approach to Calculate the Back Flashover Voltage of Shielded H.V. Transmission Line Towers

Protection against unacceptable voltages in railway systems

2000 Mathematics Subject Classification: 68Uxx/Subject Classification for Computer Science. 281, 242.2

High voltage engineering

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters

Hazard of Induced Overvoltage to Power Distribution Lines Jiang Jun, Zhao Rui, Chen Jingyang, Tian Hua, Han Lin

B2-301 IMPROVING DOUBLE CIRCUIT TRANSMISSION LINE RELIABILITY THROUGH LIGHTNING DESIGN

A Case Study on Selection and Application of Lightning Arrester and Designing its Suitable Grounding Grid

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

The Effect of Lightning Parameters on Induced Voltages Caused by Nearby Lightning on Overhead Distribution Conducting Line.

Lightning Protection of Distribution Substations by Using Metal Oxide Gapless Surge Arresters Connected in Parallel

Lightning overvoltage and protection of power substations

The Role of the Grounding System in Electronics Lightning Protection

X International Symposium on Lightning Protection

Computation of Lightning Impulse Backflashover Outages Rates on High Voltage Transmission Lines

Utility System Lightning Protection

Tab 8 Surge Arresters

The Many Uses of Transmission Line Arresters

LIGHTNING OVERVOLTAGES AND THE QUALITY OF SUPPLY: A CASE STUDY OF A SUBSTATION

TECHNICAL NOTE 2.0. Overvoltages origin and magnitudes Overvoltage protection

ABSTRACT 1.0 INTRODUCTION LIST OF SYMBOLS

Introduce system protection relays like underfrequency relays, rate of change of frequency relays, reverse - power flow

Lightning transient analysis in wind turbine blades

Parameters Affecting the Back Flashover across the Overhead Transmission Line Insulator Caused by Lightning

7P Series - Surge Protection Device (SPD) Features 7P P P

Effect of Surge Arrester on Overhead Transmission Lines as Shield against Over Voltage

Lightning Overvoltage Performance of 110 kv Air-Insulated Substation

INSTALLATION OF LSA ON A 400 KV DOUBLE-CIRCUIT LINE IN RUSSIA

Modeling for the Calculation of Overvoltages Stressing the Electronic Equipment of High Voltage Substations due to Lightning

Lightning Overvoltages on Low Voltage Circuit Caused by Ground Potential Rise

Modeling of overhead transmission lines with line surge arresters for lightning overvoltages. Poland

CHOICE OF MV FEEDER BIL TO MAXIMIZE QOS AND MINIMIZE EQUIPMENT FAILURE

In order to minimise distribution (11 and 22 kv) feeder breaker

Coordination of surge arresters in DC 3 kv railway traction system field tests

Lightning Performance Improvement of 115 kv and 24 kv Circuits by External Ground in MEA s Distribution System

Energy Division. Bowthorpe LV/MV Surge Arresters

10. DISTURBANCE VOLTAGE WITHSTAND CAPABILITY

IMP/007/011 - Code of Practice for the Application of Lightning Protection

DEPARTMENT OF ELECTRICAL AND ELECTRONICS ENGINEERING QUESTION BANK SUBJECT CODE & NAME : EE 1402 HIGH VOLTAGE ENGINEERING UNIT I

EE 1402 HIGH VOLTAGE ENGINEERING

Electric Stresses on Surge Arrester Insulation under Standard and

EXPERIMENTAL ISSUES OF OVERVOLTAGE COORDINATION

Chapter 1. Overvoltage Surges and their Effects

Transmission of Electrical Energy

ABSTRACT 1 INTRODUCTION

Lightning current field measurement on a transmission line, comparison with electromagnetic transient calculations

ROEVER ENGINEERING COLLEGE ELAMBALUR, PERAMBALUR DEPARTMENT OF ELECTRICAL & ELECTRONICS ENGINEERING

International Journal of Advance Engineering and Research Development. Analysis of Surge Arrester using FEM

The relationship between operating maintenance and lightning overvoltage in distribution networks based on PSCAD/EMTDC

Secondary Arresters. Figure 1. Type L secondary surge arrester rated 175 Vac, 125 Vdc.

Protection of low power mains against pulse power of natural lightning using spark gap arresters. Abstract

Overvoltage Protection

Cable Protection against Earth Potential Rise due to Lightning on a Nearby Tall Object

High Voltage Generation

A Study on Lightning Overvoltage Characteristics of Grounding Systems in Underground Distribution Power Cables

Journal of Asian Scientific Research SUBSTATION PROTECTION AND THE CLIMATIC ENVIRONMENT OF NIGER DELTA. John Tarilanyo Afa

CHAPTER 2. v-t CHARACTERISTICS FOR STANDARD IMPULSE VOLTAGES

Influence Of Lightning Strike Location On The Induced Voltage On a Nearby Overhead Line

HIGH VOLTAGE Insulation Coordination

Simulation of Lightning Transients on 110 kv overhead-cable transmission line using ATP-EMTP

MAHALAKSHMI ENGINEERING COLLEGE

EMC Philosophy applied to Design the Grounding Systems for Gas Insulation Switchgear (GIS) Indoor Substation

Comparison between Different InstallationLocations of Surge Arresters at Transmission Line Using EMTP-RV

The Analysis Results of Lightning Overvoltages by EMTP for Lightning Protection Design of 500 kv Substation

Computer Based Model for Design Selection of Lightning Arrester for 132/33kV Substation

The Lightning Event. White Paper

EXPERIMENTAL INVESTIGATION OF A TRANSIENT INDUCED VOLTAGE TO AN OVERHEAD CONTROL CABLE FROM A GROUNDING CIRCUIT

Effect of High Frequency Cable Attenuation on Lightning-Induced Overvoltages at Transformers

Overvoltage Protection of Light Railway Transportation Systems

Investigation of skin effect on coaxial cables

Lightning Performance of Transmission Lines with Tall Sections

Effective Elimination Factors to the Generated Lightning Flashover in High Voltage Transmission Network

Precautions to be considered for use of surge arresters tested according to Class 1 of IEC

Basics of Partial Discharge. Prepared for 2015 Phenix RSM Meeting January 2015

RF Surge Protection. Protection of the radiocommunication equipment. RF surge protection technology. RF Surge Protectors diagrams P8AX PRC CXP-DCB

WORLD MEETING ON LIGHTNING Lightning Performance Research on Mexican High Voltage Transmission Lines

Investigation on the Performance of Different Lightning Protection System Designs

Effect of Shielded Distribution Cables on Lightning-Induced Overvoltages in a Distribution System

Power Engineering II. High Voltage Testing

Research on Lightning Over-voltage and Lightning Protection of 500kV. HGIS Substation

Maximum Lightning Overvoltage along a Cable due to Shielding Failure

EVALUATION OF THE EARTH RESISTANCE VALUE FOR ESE LIGHTNING ARRESTOR TECHNIQUE FOR THE SOLAR PLANTS IN INDIA

INTERNATIONAL STANDARD

MAHALAKSHMI ENGINEERING COLLEGE

PRACTICAL PROBLEMS WITH SUBSTATION EARTHING

THE PROPAGATION OF PARTIAL DISCHARGE PULSES IN A HIGH VOLTAGE CABLE

Analysis of MOV Surge Arrester Models by using Alternative Transient Program ATP/EMTP

Experimental Study on Lightning Surge Response of 500kV Transmission Tower with Overhead Lines

Simulation Study on Transient Performance of Lightning Over-voltage of Transmission Lines

Back-flashover Investigation of HV Transmission Lines Using Transient Modeling of the Grounding Systems

Transcription:

ABSTRACTS of SESSION 6 Paper n 1 Lightning protection of overhead 35 kv lines by antenna-module long flashover arresters Abstract: A long-flashover arrester (LFA) of a new antenna-module type is suggested for lightning protection of 35 kv overhead lines. The model, designated LFA-AM, combines advantages of earlier LFA-Antenna and LFA-Modular types, getting triggered as the lightning channel approaches the line. The discharge develops in a number of relatively small modules so that a flashover of a module leaves the insulation of the arrester s cable unaffected by the voltage. Efficient performance of the new arrester was proved by its tests on a large-scale 35 kv line simulator, involving a 4 MV, 14 m long leader discharge from a 6 MV impulse generator. Keywords: Overhead distribution lines, Lightning protection, Long Flashover Arresters. Paper n 22 A methodology to the calculation of lightning performance of conventional and nonconventional transmission lines Abstract: It is presented in this paper a new methodology for the calculation of the number of direct flashes incident to distribution or transmission lines conductors, as well as for the calculation of the number of short circuits in the line provoked by these flashes. Keywords: Lightning, Transmission Line, HSIL, Non-Conventional Bundle Paper n 38 Lightning protection problems for 110 AND 220 kv overhead lines in areas with permafrost low-conductivity soils and methods of solving them Abstract: Findings of research in lightning proofness of twin-circuit 110 and 220 kv overhead lines, footing resistance being 70-100 Ohms, typical for the northern part of Tyumen Oblast, are described in this report. Furthermore, possible methods to solve the problem of poor lightning proofness are proposed. The investigation was aimed at:? assessment of operational and calculated lightning proofness characteristics of overhead lines for these conditions; and? assessment of lightning proofness enhance-ment using both traditional (insulation strengthening, footing resistance reduction) and non-traditional measures (suspension lightning arresters, modified tower design). Overhead lines operation experience as far as lightning outage is concerned has been studied. Nu-merical (computer) simulation of lightning vulnerabil-ity and field tests of natural and artificial tower grounding conductors for pulse currents have been carried out. Keywords: lightning proofness of overhead lines, grounding resistance, lightning outage rate. Paper n 40 Lightning transients In control circuit wiring in HV substations Abstract: This paper presents the mathematical model of a direct lightning stroke into an open air high-voltage HV substation. Lightning current flowing through the conductive-earthed structures over the ground and in grounding grids induced transients in control, measurement

and secondary circuits. Some calculation results of these transients in low-voltage cables are presented. Keywords: Lightning protection, lightning overvoltages, control systems, HV substation Paper n 52 Effects of Lightning Strokes to Transmission Lines on Distribution Cable Systems Abstract: Lightning surge can be transfer from one side of transformer to the other side of transformer through transformer couplings. Therefore overvoltage transfer from high voltage side of transformer will affect distribution cables, which are not directly exposed to the lightning overvoltage. The resulting overvoltage may damage the distribution systems. In this paper by choosing proper models for different parts of system in the EMTP simulation has been done for different conditions and the results have been discussed. Keywords: Lightning stroke, Transmission line, Cable system Paper n 65 Non-conventional measures for improvement of lightning performance of transmissio lines Abstract: This paper describes the evaluation of some non-conventional practices to improve the lightning performance of transmission lines, comprising the employment of auxiliary conductors and modification of grounding electrodes configuration. The results are obtained by simulation, employing a hybrid electromagnetic model to determine the amplitude of the overvoltage developed across insulator strings, due to direct strikes. The efficiency of such practices was evaluated for the actual conditions of a 230 kv line. Passed one rainy season since their implementation, the number of lightning associated outages was drastically diminished. Keywords: Lightning performance of transmission lines, Non-conventional practices to improve line performance, Grounding behavior for lightning currents. Paper n 70 A methodology based on severity indexes to determine critical spots along transmission lines concerning lightning performance Abstract: This paper is dedicated to a comparative analysis of the results provided by the application of a methodology for identifying critical spots along transmission lines, in terms of lightning performance to two different lines. This technique is based on processing Lightning Location System indications and some line parameters. Keywords: Lightning Performance of Transmission Lines, Lightning Location System, Lightning Protection Paper n 72 Damages in equipment of a hydroelectric power plant substation due to lightning - qase study Abstract: This work presents some solutions proposed for lightning protection of a hydroelectric power plant substation. Analyses of the substation damage reports denoted that two types of events may involved: direct strikes to the substation telecommunication tower and direct strikes to the 13.8kV unshielded distribution line (used for substation internal services power supply). The occurrences caused the establishment of significant overvoltage

values at the substation grounding grid. Additionally, this work presents some solutions for equipment protection. Simulation results predicted voltage mitigation at the grounding grid (for the investigated occurrences) up to 70% in case of implementation of the proposed solutions. Keywords: Lightning protection of substations, GPR mitigation. Paper n 88 Evaluation of the effects of the lightning discharges in the overhead-line conductors used in electric rural distribution Subject: This paper presents some experimental results of the behaviour investigation of typical overhead-line conductors used in rural distribution when subjected to atmospheric discharges. Paper n 101 Effect of multiple lightning impulse currents on zinc oxide arrester blocks Abstract: This paper presents the effect of multiple lightning impulse currents on zinc oxide (ZnO) surge arrester blocks. In order to investigate the dynamic characteristics of ZnO arrester blocks with respect to multiple impulse voltages, we have been designed and fabricated the multiple combination wave generator. The multiple combination wave generator can produce quintuple1.2/50? impulse voltages of 100 kv and quintuple 8/20? impulse currents of 12 ka. The electrical and physical properties of ZnO arrester blocks were evaluated. The multiple impulse failures of ZnO arrester blocks are mainly caused by the surface flashover. In the case of multple impulse voltages, the charge enhancement near the joined edges of ZnO arrester block and metal electrodes plays a decisive role on the surface flashover or breakdown initiation and developments. Also, it was found that the changes in the residual voltage and quiescent current of ZnO arrester blocks after the injection of the quintuple 8/20? impulse currents of 10? were markedly occurred. Paper n 124 Evaluation of fuses forprotection of lightning current arresters close to transformers of high rated power. Abstract: Class I lightning current arresters in low voltage power systems need a protection by a fuse if the actual short circuit current at the location of the arrester is higher than the rated short circuit current. The aim of this paper is to focus on the installation problems near a transformer station with high rated power. Keywords: Class I arrester, mains follow current, evaluation of a fuse Paper n 131 Breakdown characteristics of air spark-gaps stressed by short tail lightning impulses : test results and comparison of different time to sparkover models Abstract: The paper reports the results of an investigation carried out in order to determine the critical flashover voltage, and the relevant standard deviation, of the rod-rod air gaps (10 and 20 cm) under standard lightning impulse (LI: 1.2/50 µs) and an impulse voltage with short tail (STLI: 1.2/4 µs). The volt-time characteristics of these spark-gaps are also determined under LI and STLI and the experimental test results are compared and discussed. Models based on the disruptive effect, as proposed by Kind [4], and modified by Chowdhuri [6], are

considered and applied in order to predict the Volt-time characteristics under standard and non standard lightning voltages. The viability of the application of these models to the insulation under consideration is considered and discussed. Paper n 136 Lightning surge response on actual 500kV transmission tower with overhead ground wires Abstract: This paper quantitatively shows the effect of the configuration of current lead wire used for measurement on tower surge response of an actual 500kV transmission tower with overhead ground wires. The measured voltages across insulator strings of each crossarm depended on the configuration of auxiliary current wire. The above measurements confirmed that 45-60% of the injection current flowed into ground wires. Assuming that surge impedance of ground wires is constant under lightning surge, this suggests that the tower surge impedance is affected by lightning path. Keywords: Tower surge impedance, Lightning, Voltage across insulator strings, Tower surge response Paper n 145 Observation of lightning over-voltages at a Japanese EHV station Abstract: This paper describes observation results of lightning overvoltages at an EHV switching station of Kansai Electric Power Co. The observation results show that the lightning overvoltage due to a back flashover is not always higher than operation voltage of surge arrester. This paper investigates an influence of electromagnetic fields generated by returnstroke current in a lightning channel on the lightning overvoltage. Keywords: Lightning overvoltage, Back flashover, Direct lightning hit, Lightning-induced voltage, Observation, EHV station Paper n 160 Lightning current evaluation for arrester application in buildings with medium voltage supply Abstract: In this work numerical calculations of the lightning stress of a typical electrical system used in a building was carried out, if a medium voltage supply unit is located inside the building. The impedances of all electrical circuits have an essential influence on the protection quality of the building. So a different transient current distribution is given in comparison to a closely meshed earthing situation. Due to the single feeder situation in most cases one cannot proceed from the parallel connection of all grounding systems as this is the case with closely meshed networks in the low voltage level usually. Apart from theoretical considerations a system model is provided. The results are compared on the basis of the standards and give new ideas for the application in the field of the overvoltage protection in buildings, when the low voltage system and the medium voltage system are connected or close together. Keywords: Lightning protection, overvoltage, arrester, modelling, numerical calculation. Paper n 176 Optimisation of the High Voltage Substation - Direct Lightning Stroke Protection System Abstract - This paper presents results of the study dealing with the application of lightning rods for the substation direct stroke protection. Lightning rod locations and heights are determined using simulation software sigma ssh. This software uses a three-dimensional

Monte Carlo electro geometric modelling. Study results for one particular 275 kv and one 500 kv substation are presented. Keywords - Lightning, Direct stroke shielding, Substation, Lightning rod, Shield wire Paper n 182 Response of pole-type distribution transformers to ligthning overvoltages Abstract: Pole-type transformers on a power distribution line are vulnerable to lightning overvoltages, and their response draws great concern. In this paper, an equivalent circuit of transformers whereby one can cope with their response to overvoltages both on mediumvoltage and low-voltage lines is presented. The dependency of the response of transformers on the rated power is investigated. By comparing response of the transformer calculated by using the developed circuit with that calculated by using a circuit represented by capacitance, the characteristics of the developed circuit are demonstrated. Keywords: Pole-type transformer, lightning overvoltage, distribution line, equivalent circuit Paper n 185 Development of 22kV tubular ligthning protection devices Abstract: Kyushu Electric has newly developed a tubular lightning protection device for overhead distribution lines, which functions by discharging inside the tube. This development will significantly contribute to a reduction in arrester production costs as well as enhancement of discharge withstand current ratings. While the authors have already created a 6.6kV tubular lightning protection device, which does not lead to AC follow current after the lightning impulse current flows. There is a focus on the development of a 22kV tubular lightning protection device tube horn which leads to AC follow current for half cycle after the lightning impulse current flows. Keyword: Lightning protection, distribution line, power quality, expulsion-type arrester Paper n 188 Line surge arrester application pilot project Abstract - This paper describes a pilot project of line surge arresters installation on a 123 kv overhead line Ston- Komolac in Croatia. Determination of the arrester number and selection of their installation configuration was based on the software simulations. Line lightning performance is determined for the different arrester installation configurations, taking into account measured tower footing resistance. Line surge arresters with a gap and gapless line arresters are used. In order to follow this project certain number of surge arrester monitors was envisaged. Keywords - Lightning performance, Line surge arrester, Lightning location system Paper n 201 Ligthning performance of overhead power distribution lines considering effect of nearby trees Abstract: Some theoretical researches have been done to clarify the manner of a lightning stroke attachment to power lines considering nearby trees. But few experimental researches have been done related to the above problem. Several Japanese electric power companies have observed the manner of lightning stroke attachment on power distribution lines using still cameras. Recently, the attachment manner of a lightning stroke was observed at a location where trees grow nearby overhead distribution line. In this case protective effect of

trees can be expected, but the fact was contrary to the expectation. In order to develop better lightning protection methods of power distribution lines, we have investigated about the manner with which a lightning stroke approaches power distribution lines. Experimental results shows that the existence of nearby trees do not always give better lightning performance. Sometimes the existence of nearby trees leads to extra outages of power distribution lines. The flow chart of the calculation program for a lightning performance of overhead power distribution lines taking the effect of nearby trees into account is described. Keywords: Lightning, lightning protection, distribution line, tree Paper n 209 Lightning-Induced Overvoltages on MV Distribution Lines: Spacer-Cable Versus Conventional Line Configurations Abstract: In this paper, it is presented a comparative study concerning the influence of lightning-induced voltages on two different medium voltage line configurations, namely spacer-cable and conventional lines. Main results indicate that the presence of two periodically grounded conductors makes spacer-cable lines more sensitive to the variation of grounding parameters than conventional lines. In most cases, this fact contributes to reduced levels of induced voltages on the spacer-cable configuration. Keywords: Lightning-induced voltages, distribution lines, spacer-cable lines. Paper n 214 High performance triggered lightning current arresters Abstract: Triggered lightning current arresters are used to build up compact multistage surge protective systems with energetically coordinated type 1- and type 2-arresters. A new triggered spark gap generation with high distance electrode configuration and its behaviour concerning lightning current capability, protection level and power following current is presented in this paper. In connection with enhanced type 2-arresters an extensive protective system with several new benefits is created. Keywords: SPD, Triggered spark gap, type 1-arrester, energetic coordination Paper n 237 Examples of errors causing lightning damages in electrical installations Abstract: Examples of erroneously made electrical installations are presented. Most of them were the causes of lightning damages. A discussion of design and mounting errors is provided. Photographs of lightning destructive actions are shown. Keywords: Grounding, lightning protection system, equipotentialization, overvoltage protection, damages. Paper n 242 Evaluation and improvement of lightning protection on transmission and distribution lines Using lightning detection network Abstract : Very high records of outage of transmission and distribution lines have taken place at the oil company region located in central Sumatra. The operational area of this oil company located along the equator line and has a very high lightning density. Medium voltage 13.8 kv

line which has a very high outage rate connected directly to the electrical pumps on the field. The failure of the supply caused very high loss of daily oil production. A one whole year study was carried out in this region and lightning detection network was installed which has 5 sensors that cover the whole area of the region. Lightning characteristic for the evaluation and improvement of the lightning performance of the power lines were derived from this Indonesia Lightning Detection Network using Time of Arrival Technology. The improvement of overhead lines lightning performance was carried out in two ways. The first one is using a conventional way which is commonly used to improve the lightning performance of the lines, such as ; installing the overhead ground wire, installing lightning arrester on the poles, increasing insulator levels to have higher the critical flashover values and improving the grounding system. The second one is using freestanding mast (fsm) or extended tower equipped with air terminal, which is connected to the grounding system using insulated down conductor. This arrangement will prevent the ground wire and poles being hit directly by lightning. No line parameters will be read by the lightning current and no back flashover (low inductance of cables) and shielding failures (higher coverage area of the air terminal) will take place. Installation of the second protection system in 13.8 kv lines at site Bangko could give significant improvement of the lightning performance. Paper n 250 Estimation of lightning-caused stresses in MV distribution line Abstract: An approach is developed for the estimation of lightning-associated ovorvoltage stresses coming from MV overhead distribution lines. Analysis is performed for surges caused by both direct and nearby lightning, taking into consideration their attenuation along the line due to effects of corona and finite ground conductivity. Calculations are made considering a typical 10-kV line in Ukraine, represented by a single wire. Numerical results are presented in terms of voltage surge amplitudes and front steepnesses, and period of their occurrence at the considered point (end, middle of the line). Discussion is provided on possible applications (surge protective devices, etc.) and further developments. Keywords: Lightning, surges, distribution MV line.