Welcome to the rd. Annual Northern Ohio. 3 rd Energy Management Conference September 30, 2008

Similar documents
3/29/2012 MAIN TOPICS DISCUSSED ELECTRICAL SYSTEMS AND ELECTRIC ENERGY MANAGEMENT SECTION K ELECTRIC RATES POWER COMPUTATION FORMULAS.

Introduction to Harmonics and Power Quality

Effective Harmonic Mitigation with Active Filters

PQ01. Harmonic Solutions for VFD s. Review of Power Control Harmonics, Power Factor, Distortion & Displacement

Fundamentals of Power Quality

Electrical Theory. Power Principles and Phase Angle. PJM State & Member Training Dept. PJM /22/2018

An Introduction to Power Quality

ECET Modern Power

Thyristorised Automatic Power Factor

Power Quality Monitoring and Power Metering Tutorial

Harmonics and Their Impact on Power Quality. Wayne Walcott Application Engineering Manager June, 2017

World Academy of Science, Engineering and Technology International Journal of Electrical and Computer Engineering Vol:7, No:6, 2013

Harmonic Filters for Power Conversion Equipment (Drives, rectifiers, etc) Effects of Harmonics IEEE Solutions

How adjustable speed drives affect power distribution

Low Pass Harmonic Filters

CASE STUDY. Implementation of Active Harmonic Filters at Ford Motor Company SA Silverton Plant

CHAPTER 5 POWER QUALITY IMPROVEMENT BY USING POWER ACTIVE FILTERS

McGill Power Sales & Engineering, INC.

PRUDENT PRACTICES TO IMPROVE POWER FACTOR AND REDUCE POWER LOSS.

VFDs and Harmonics in HVAC Applications

Section 11: Power Quality Considerations Bill Brown, P.E., Square D Engineering Services

ELG 4125: ELECTRICAL POWER TRANSMISSION AND DISTRIBUTION: TUTORIAL 1: - BY:

Active Harmonic Filter (AF3)

Generator Advanced Concepts

Power Factor improved by Variable Speed AC Drives By Mauri Peltola, ABB Oy, Drives

Guide to Harmonics. Reactive Power and Harmonic Compensation POWER QUALITY. The Basics of Harmonics

7/15/2002 PP.AFD.08 1 of 28

ASSOCIATION OF ENERGY ENGINEERS NORTHERN OHIO CHAPTER APRIL 21, 2005

ENERGY SAVINGS THROUGH POWER CONDITIONING WITH THE PowerGUARD SYSTEM

Harmonics, its Mitigation & Result of Case study of Spinning Mill

SOUTH CENTRAL INDIANA REMC Application for Operation of Member-Owned Small Power Generation Systems

DSP-BASED CURRENT SHARING OF AVERAGE CURRENT CONTROLLED TWO-CELL INTERLEAVED BOOST POWER FACTOR CORRECTION CONVERTER

Power Quality Monitoring:

POWER QUALITY A N D Y O U R B U S I N E S S THE CENTRE FOR ENERGY ADVANCEMENT THROUGH TECHNOLOGICAL I NNOVATION

Technical Paper. Harmonic Distortion in Data Centers

Power Factor & Harmonics

Power Quality Analysers

Do You Have a Harmonic Problem?

PQ for Industrial Benchmarking with various methods to improve. Tushar Mogre.

Electric Power Quality: Voltage Sags Momentary Interruptions

EASTERN ILLINI ELECTRIC COOPERATIVE Application for Operation of Member-Owned Generation

TRANSFORMER OPERATION

PART 1 OWNER/APPLICANT INFORMATION

APQline Active Harmonic Filters. N52 W13670 NORTHPARK DR. MENOMONEE FALLS, WI P. (262) F. (262)

Reducing Total Harmonic Distortion with Variable Frequency Drives

Understanding Harmonics

Harmonics White Paper

Liebert AF2 Next Generation Active Harmonic Filter. Power Protection for Business-Critical Continuity TM

E S C R I P T I V E B U L L E T I N .,.,.,. Bulletin DB-106. October, Square D Company Power System Studies ---1 I SQU ARED COMPANY --

Owner/Customer Name: Mailing Address: City: County: State: Zip Code: Phone Number: Representative: Address: Fax Number:

Power. Power is the rate of using energy in joules per second 1 joule per second Is 1 Watt

Please use the Q & A utility to ask us any questions concerning the material being presented.

VARIABLE FREQUENCY DRIVE OPERATION AND APPLICATION OF VARIABLE FREQUENCY DRIVE (VFD) TECHNOLOGY

POWER FACTOR CORRECTION USING BOOST CONVERTER

Dynamic Harmonic Mitigation and Power Factor Correction

Understanding Power Quality

Power Quality in Metering

Power Quality and Circuit Imbalances Northwest Electric Meter School Presented by: Chris Lindsay-Smith McAvoy & Markham Engineering/Itron

+ 24V 3.3K - 1.5M. figure 01

Power Quality Testing

6L]LQJ$8366\VWHP )RU1RQ/LQHDU/RDGV

ENGINEERING DATA SUBMITTAL For the Interconnection of Generation System

1C.4.1 Harmonic Distortion

There s Gold in Those Waveforms Richard P. Bingham, Dranetz-BMI

Harmonic Mitigation for Variable Frequency Drives. HWEA Conference February 15, Kelvin J. Hurdle Rockwell Bus. Dev. Mgr.

A Guide to Power Quality Testing

UNIVERSAL MEASURING INSTRUMENTS. TNM 34xx. TNM 3410 / 3420 / 3430 / 3440 Universal measuring instrument 1/49

DISTRIBUTION SYSTEM VOLTAGE SAGS: INTERACTION WITH MOTOR AND DRIVE LOADS

SECTION 1 INTRODUCTION

Power Factor. Power Factor Correction.

Harmonic Solutions in Electrical Systems. Raed Odeh Application Specialist - Power Quality & Electrical Distribution

UNDERSTANDING POWER QUALITY

Harmonics I Harmonics White Paper. Power Protection Products, Inc. by Dan Maxcy l 2018 Update

Electrical Motor Power Measurement & Analysis

HARMONICS CAUSES AND EFFECTS

Power IT LV Active Filters PQFA - PQFL - PQFT

Open-Delta Systems Affect Variable Frequency Drives

HARMONICS THE BASICS H A R M O N I C M I T I G A T I O N A N D D I S P L A C E M E N T P O W E R F A C T O R C O R R E C T I O N

Power Factor Improvement Using Thyristor Switched Capacitor Using Microcontroller Kacholiya Saurabh 1, Phapale Sudhir 2, Satpute Yuvraj 3, Kale.S.

Electromagnetic Harmonic Filters Technical Guide

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Power Factor and Power Factor Correction

CHAPTER 3 IMPROVEMENT OF LOAD POWER FACTOR USING FACTS CONTROLLERS

Harmonic Requirements

AC Sources for IEC 1000 Harmonics and Flicker Testing

APPENDIX B: Generation Interconnection Application Form

Presents. Harmonics Years

With any other power quality analyzer you re just wasting energy.

Understanding Harmonic Suppression Systems

Harmonic Filters for Single Phase Equipment

Figure 1 Typical Inverter Block Diagram

ARE HARMONICS STILL A PROBLEM IN DATA CENTERS? by Mohammad Al Rawashdeh, Lead Consultant, Data Center Engineering Services

SIMPLE SOLUTIONS FOR IMPROVING LIFE OF BREAKERS USED IN TRANSMISSION AND DISTRIBUTION SYSTEMS

Thermal Imaging, Power Quality and Harmonics

Power Analysis Summary

Power Quality Analysis: A Study on Off-Line UPS Based System

ACS 1000 Transformer Failure Investigation. Nathan Schachter, Peng

MICROPROCESSOR-BASED METERING EQUIPMENT SECTION 16901C PART 2

NJWA - Harmonics and Drives Proper System Design

Fluke 40/41 Power Harmonics Analysers

Transcription:

Welcome to the rd Annual Northern Ohio 3 rd Energy Management Conference September 30, 2008

Recover Lost Dollars Demand Side Electrical Energy Savings By Improving Distribution System Efficiency, Capacity and Power Quality Presented by Benjamin Rosolowski

Basic Issues Related to Electrical Distribution Reliability Capacity Safety Operating Costs

Terms & Definitions Sinusoidal Wave Forms Power Quality Electrical Loads Types Harmonics RMS Power Factor

Nature of a Sine Wave 1 cycle 360 degrees 1/60 second Positive peak AMPLITUDE AMPLITUDE Negative peak ZERO CROSSING 0 90 180 270 360 450 540 630 720 WAVE ANGLE IN DEGREES (OR TIME)

Utilities Typically Supply Pure Efficient Power

Terms & Definitions Sinusoidal Wave Forms Power Quality

What is Power Quality? Power Quality is the quality of the electric power supplied to electrical equipment. There is no single way to completely quantify the quality of Power. Poor power quality can result in misoperation of the equipment and higher energy costs.

Most Common Power Quality Issues Voltage sags, dips & swells Voltage & Current Distortion Transients Harmonics Voltage Unbalance & Regulation Flicker Frequency variations Inrush Poor Power Factor

Poor power quality is reflected in your monthly electric bill as increased kw/kva (Demand) and kwh (Usage).

Symptoms of power quality problems can be categorized into two main areas: Equipment failure and misoperation Economic considerations

Terms & Definitions Sinusoidal Wave Forms Power Quality Electrical Load Types Resistive, Inductive Linear vs. Non Linear

Electrical Distribution System 64kV Utility Feed Typical Plant Loads Buss Duct DC Drives VFD s Outlets 480V/277V Xformer Motors Lighting 13.2kV/480V Dist. Xformer 2000A 3 Switchgear UPS s PC s MDP 400A 208V/120V HVAC Robotics Induction Furnace ARC Welder VFD s Typical Office Loads

Examples of Resistive Loads Incandescent Light Bulb Hot Plate Electric Hot Water Tank

Examples of Inductive Loads Transformers Motors Lighting Ballasts Induction Furnaces

Linear & Non-Linear Linear Load - The current waveform looks like the voltage waveform Non-linear Load The current waveform does not look like the voltage waveform The more the current looks like the voltage, the more linear the load

What do Non-Linear Loads have in common? Convert AC into DC Contain some kind of rectifier Induce harmonic currents React with the source to produce harmonic voltage distortion

Linear & Non-Linear Loads What is important? Linear Loads Draw their power at 60 Hz Non-linear Loads Draw their power from 60 Hz ; however, they reflect large amounts of harmonic current back into the distribution system

Single-Phase 2-pulse Diode Bridge (Schematic Diagram) + _

Electrical Distribution System 64kV Utility Feed Typical Plant Loads Buss Duct DC Drives VFD s Outlets 480V/277V Xformer Motors Lighting 13.2kV/480V Dist. Xformer 2000A 3 Switchgear UPS s PC s MDP 400A 208V/120V HVAC Robotics Induction Furnace ARC Welder VFD s Typical Office Loads

Three-Phase 6-Pulse Diode Bridge (Schematic Diagram) + _

Typical Non-Linear Loads (Two Pulse and Six Pulse Rectifiers) Computers Copy & Fax Machines Solid-State Lighting Ballasts Programmable Controllers DC Drive Systems VFD s Electroplating Processes Solid State UPS s Induction Furnace

Terms & Definitions Sinusoidal Wave Forms Power Quality Electrical Loads Types Harmonics

What are Harmonics? Integer multiples of the fundamental frequency (Voltage or Current at 60 hertz)

Table of Harmonics HARMONIC 1 2 3 5 7 9 11 49 FREQUENCY U.S. POWER 60 120 180 300 420 540 660 2940 AIRCRAFT 400 800 1200 2000 2800 3600 4400 19600

Harmonic Waveforms Algebraically add and subtract to distort the fundamental waveform FUNDAMENTAL 3rd HARMONIC AMPLITUDE 5th HARMONIC 0 90 180 270 360 WAVE ANGLE

Poor Power Quality ( Dirty ) <60%

Symptoms of Harmonic Problems Overheated phase conductors, panels, and transformers Random tripping of circuit breakers Premature failure of transformers and UPS systems Reduced system capacity Very high neutral currents Low Power Factor

Electrical Distribution System 64kV Utility Feed Typical Plant Loads Buss Duct DC Drives VFD s Outlets 480V/277V Xformer Motors Lighting 13.2kV/480V Dist. Xformer 2000A 3 Switchgear UPS s PC s MDP 400A 208V/120V HVAC Robotics Induction Furnace ARC Welder VFD s Typical Office Loads

Terms & Definitions Sinusoidal Wave Forms Power Quality Electrical Loads Types Harmonics RMS

What is RMS? (Root Mean Square) & Why is it Important?

Definition of RMS Values (rms means root mean square) Q I ( rms ) = I 2 n n= 1 I I 2 I 2 I 2... I ( rms ) = + + + + w 1 3 5 2 n I ( rms ) 2 2 2 = 70 + 50 + 30 + 20 2 = 93 amps

Why is RMS Important? The importance of RMS voltage and current are that they can be directly used to calculate the total or true power.

Single-Phase 2-pulse Diode Bridge (Schematic Diagram) + _

Single-Phase 2-Pulse Diode Bridge (Waveform) Voltage Current 0 90 180 270 360 450 540 630 720 WAVE ANGLE IN DEGREES

Single-Phase 2-Pulse Rectifier (Typical for Personal Computers) CURRENT % FUNDAMENTAL 100 90 80 70 60 50 40 30 20 10 0 1 3 5 7 9 11 HARMONIC NUMBER 13 15 17 19

Electrical Distribution System 64kV Utility Feed Typical Plant Loads Buss Duct DC Drives VFD s Outlets 480V/277V Xformer Motors Lighting 13.2kV/480V Dist. Xformer 2000A 3 Switchgear UPS s PC s MDP 400A 208V/120V HVAC Robotics Induction Furnace ARC Welder VFD s Typical Office Loads

Three Phase Variable Frequency Drive (VFD)

Three-Phase 6-Pulse Diode Bridge (Schematic Diagram) + _

Electrical Distribution System 64kV Utility Feed Typical Plant Loads Buss Duct DC Drives VFD s Outlets 480V/277V Xformer Motors Lighting 13.2kV/480V Dist. Xformer 2000A 3 Switchgear UPS s PC s MDP 400A 208V/120V HVAC Robotics Induction Furnace ARC Welder VFD s Typical Office Loads

6-Pulse Diode Bridge Rectifier Harmonic Current Spectrum (Half & Full Speed Operation) CURRENT % FUNDAMENTAL 100 90 80 70 60 50 40 30 20 10 0 1 3 5 7 9 11 13 HARMONIC NUMBER 15 17 19 HALF LOAD FULL LOAD

Unloaded

Fully Loaded

7 th Harmonic Current Distortion (420Hz)

Terms & Definitions Sinusoidal Wave Forms Power Quality Electrical Loads Types Harmonics RMS Power Factor

Utility Billing Parameters kw kwh kva kvar kvarh PF Thousand Watts Thousand Watt hours Thousand Volt Amps Thousand Volt Amps Reactive Thousand Volt Amps Reactive Hours* Power Factor * No unit cost typically associated with this parameter. Used by utility to calculate PF.

kw Kilowatts Working power (kw) to perform the actual work of creating light, heat, torque, etc. Measured on a wattmeter in kilowatts. kw (Watts) Working power

kwh Kilowatt-Hour Number of actual watts times the hours they do work

kvar Kilo-Volt Amperes Reactive Power required to sustain the magnetic field of an inductive load. Performs no useful work Circulates between the power supply and the load Measured by the utility as kvar demand Reactive Power

Power Factor Triangle Working Power in watts Reactive Power in kvar

kva Kilovolt-Amperes (Supplied Power) Supplied Power (kva) is made up of working power (kw) and reactive power (kvar). Measured in kilovolt-amperes (kva) Working Power Supplied Power Reactive Power

POWER FACTOR θ kw (Working Power) kva (Total Supplied Power) kvar (Reactive Power) Power Factor = kw (working power) kva (total supplied power)

How Poor Power Factor Relates to Wasted System Capacity Working Power (kw) Wasted System Capacity Supplied Power (kva) Reactive power (kvar)

Simply Put! Poor Power Factor means more current is flowing through the electrical distribution system than is necessary to do the required work.

Line Loss (I 2 R) = Watt Loss Working Power (kw) Wasted System Capacity Supplied Power (kva) Reactive power (kvar)

Total Power Factor with Harmonics kw 60 kva rms kvar 60 kva 60 DISPLACEMENT PF = kw 60 kva 60 = 0.87 TOTAL PF = kw 60 kva rms = 0.77 Harmonic Content

Poor Power Quality & Poor Power Factor Putting it all together

Unloaded Electrical System, Perhaps Your Transformer Capacity 1000 kva Total System Capacity

Poor Power Quality Low PF No Available System Capacity Poor PQ & Low PF No Available System Capacity (kw) Total System Capacity

Good Power Quality High Power Factor More Available System Capacity Good PQ & High PF More Available System Capacity (kw) Total System Capacity

How efficient is your system?

You can t control what you don t measure!

You can t capture ($ s) if you don t invest in expertise and equipment that pays you back!

Applied Technologies

Basic Steps Toward Improving Electrical Efficiency 12 Months Billing History Power & Energy Study Determine Load Ratio Power Quality Assessment Evaluate Data & Information Design a Comprehensive Strategy Select Appropriate Technology/Operational Adj. Life Cycle Cost Analysis Submit a Project Appropriation Request

Thank You! Phone : 216-525-0046 Fax : 216-525-0047 Web : cpigroupltd.com Email: br@cpigroupltd.com