Dual Reversing Module

Similar documents
Hexa Multi Module 366HMM. Introduction. Design Specifications. Key Features

TECHNICAL PRODUCT DATASHEET

Smart Power Relay E I...

Electronic Circuit Breaker ESS20-0..

PRODUCT SPECIFICATION. This specification defines the detailed requirements for the Minitek Pwr3.0 wire to wire and wire to board connectors.

sealed mini usb connectors

From dc to 10 GHz the. VSWR shall not exceed 1.3 &.04 (f) where f is the frequency in Gigahertz (GHz).

KILOVAC EV200 Series Contactor With 1 Form X (SPST-NO) Contacts Rated 500+ Amps, Vdc

200 Watt Passive Shunt Module

2.4mm coaxial connectors for frequency test measurements

Electronic Circuit Breaker with reset input ESS20-1..

242, , FAX.

Small-sized, plastic type, push-pull lock connectors

LENORD. PowerDRIVE-Positioning GEL 6109 Compact positioning drive for installation situations with little space. +BAUER... automates motion.

Low Profile. 3 Year Warranty

Sealed Interface Control: EC20300

242, , FAX.

JDX Hybrid Mixed Power & Signal

POWER RELAYS CONTINUOUS DUTY, TYPE II, UNSEALED INTERMITTENT DUTY, TYPE III, UNSEALED

Schottky Barrier Rectifier

.093 [2.36] Commercial Pin and Socket Connectors

Tru products are now under the Tru-Win brand from Winchester Interconnect.

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

SMB Connectors. Adaptors-50Ω. Plug to Plug. Jack to Jack. Plug to Jack. Bulkhead Jack to Jack

TECHNICAL DATASHEET #TDAX Universal Input, Single Output Valve Controller CAN (SAE J1939)

YL SERIES RELAY LATCH DC COIL 4PDT, LOW LEVEL TO 5 AMP

PKG-171-MBC25-PS-CBL System Diagram and Specifications

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE

HIGH VOLTAGE AND CURRENT CUT-OFF CAPACITY IN A COMPACT PACKAGE FEATURES

DSA150 Series. xxx Series. 150 Watts. AC-DC Power Supplies. Models & Ratings. Mechanical Details 3.92 (99.8) 2.18 (55.5) 4.92 (125.

P/N: AX Applications: Off-highway construction equipment Municipal vehicles. Ordering Part Numbers:

NOsparc! MHXAC1F120! MHXAC1F240! MHXAC1F480 PATENTS AND PATENTS PENDING. Contact Arc Suppressor


Ø1,37 (.054) MIN Ø2,67 (.105) MAX Ø1,35 (.053) MAX Ø4,83 (.190) MAX 1,78 (.070) MAX 0,84 (.033) SEE NOTE # 2 1,91 (.075) MIN MIN CLOSED ENTRY CONTACT

242, , FAX.

Series 291 Optical Encoder

Schottky Barrier Rectifier

EN2 SERIES SEALED CONNECTORS

Polarized, latching hermetically sealed relay Contact arrangement. 3 PDT Coil supply

SPECIFICATION AND PERFORMANCE CHARACTERISTICS SERIAL ATA CABLE ASSEMBLIES

CAPSULE CONTACT MECHANISM AND HIGH-CAPACITY CUTOFF COMPACT RELAY FEATURES

Single-output models feature wide-range output adjustability to meet a wide variety of standard and user-specific output voltage requirements.

Rotary Measurement Technology Incremental Encoders

TPP 40 Series, 40 Watt. Order code Output voltage Output current max. Efficiency. max. screw terminal pin connector Vout 1 Vout 2 Vout 3

WORLD-BEAM QS18AFF200 Sensors with Foreground Suppression

S24SE/S24DE series 30W Single/Dual Output DC/DC Converter

SMB Connectors. RF Coax Connectors. Product Facts

Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

This convection-cooled series is designed for use in commercial and industrial environments in temperatures up to 50 C.

The outputs can also be programmed as 0-5 Vdc, 0-10 Vdc, 0-20 ma, 4-20 ma, Frequency, RPM, PWM or digital on/off signals.

General. Environmental. EMC & Safety

SERIESN50, COAXIAL CONNECTORS

100W Wide Band Power Amplifier 6GHz~18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz Gain db


Aegis Power Systems, Inc., P.O. Box 429, 805 Greenlawn Road, Murphy, NC Tel: (828) Table 1: Maximum Ratings

Resilient 3000 EP3000AC48IN Rectifier 3000W Output at 48 58Vdc

PRODUCT DESCRIPTION PAG ES. E110 Series 1PDT, 10 AMP RELAY 2-6. E310 Series 3PDT, 10 AMP RELAY E210 / E215 Series 2PDT, 10/15 AMP RELAY 13-19

DC Output Voltage range: 5 to 50VDC Current range: 0 to 40A Power range: 0 to 500W Peak power: Up to 750W for up to 4 seconds.

20W Solid State Power Amplifier 26.2GHz~34GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units. Frequency Range GHz.

TECHNICAL DATASHEET #TDAX Universal Signal Inputs CAN Controller V, ma, Digital, PWM, Hz/RPM, Counter Inputs CANopen P/N: AX030121

S24SE/S24DE series 15W Single/Dual Output DC/DC Converter

Powerpole Connectors - PP75: up to 120 Amps

SERIES KC RELAY NONLATCH 3PDT, 25 AMP

(*) Reference the User Manual or contact the factory for parallel operation between modules plugged into slots 1/2/3/4 and slots 5/6/7/8.

Control module CP-A CM

MX150 Sealed Connector System

200A type has been added. High Capacity of Max. 1,000 V DC Cut-off Possible

Universal Radius Mounting Option. Fixed Radius Mounting Option

5W Ultra Wide Band Power Amplifier 2-18GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

U5300 Industrial Pressure Transducer

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

PERFORMANCE SPECIFICATION SHEET

High Capacity of Max. 1,000 V DC Cut-off Possible

8W Wide Band Power Amplifier 1GHz~22GHz

Applications: Power generation, Cogeneration, Stationary power Large engines

2 or 4 pole changeover contact Plug-in/Faston 187

3.6. Control Relays and Timers D A M D 2. Contents. Product Overview. Catalog Number Selection. Solid-State Relays

Amphenol RF. MMCX Micro-Mate (MMCX) Connectors MMCX. Description. Features/Benefits. Applications

PKG-232-MBC12-PS-CBL System Diagram and Specifications

MIL-PRF-83536/5C 08 June 2010 SUPERSEDING MIL-PRF-83536/5B 04 December 2008 PERFORMANCE SPECIFICATION SHEET

Current / residual current and voltage transformers. Current / residual current and voltage transformers

SINGLE-PHASE VSV SWITCH

ACTUATOR LA36 PRODUCT DATA SHEET

30W Solid State High Power Amplifier 2-6 GHz. Parameter Min. Typ. Max. Min. Typ. Max. Units

WORLD-BEAM QS18AF Sensor with Background Suppression

ADC5000 SERIES. AC/DC Switch Mode Power Supplies and Rectifiers for Industrial and Telecom Applications. 60W, 125W and 250 W

2-Way Proportional Logic Cartridge Valve Model FE.. (Series 1X and 2X) PSI (315 bar) F with electrical connection 12 X Y

Model 97 & 99-5/8 Square Single-Turn Panel Control with Rotary Switch

DC/DC Converter 9 to 36Vdc and 18 to 75Vdc input voltage, 20 Watt Output Power; 3.3 to 15Vdc Single Output and ±12Vdc to ±15Vdc Dual Output

SilverMax Datasheet. QuickSilver Controls, Inc. NEMA 23 Servomotors.

PRODUCT SPECIFICATION

AU INSTALLATION INSTRUCTIONS. Revision B1 Rapid City, SD, USA, 02/2010 II_201A-AU_B1

SMA 50 Ohm Connectors Alphabetical Index INCHES (MILLIMETERS) CUSTOMER DRAWINGS AVAILABLE ON REQUEST

Alternating Current Power

XXXX e. X d.. X X X a

4W Ultra Wide Band Power Amplifier 0.1GHz~22GHz

Lexium integrated drives

847H. Description. Features. Specifications

S24SP series 60W Single Output DC/DC Converter

PERFORMANCE SPECIFICATION SHEET RELAY, ELECTROMAGNETIC PERMANENT MAGNET DRIVE, 25 AMPERES, SPDT, HERMETICALLY SEALED

Transcription:

Dual Reversing Module Introduction The E-Plex 425DRM has been designed to simplify wiring in electronic systems by providing the reversing function local to the motor devices thus eliminating long cable runs back to common control systems. This is accomplished with four DPST relays with the common connections of two relays wired to either side of a motor. When one relay is active, power is supplied in one direction. When the motor is reversed the relays switch states allowing the power to flow in the opposite direction. A solid state switch monitors the current draw of the motors which allows for intelligent feedback as to the condition of the motor. A typical operation would show an initial surge of current as the motor begins to move which decays to a steady state level as the motor gets underway. When it reaches its limit the motor will again begin to draw additional current which can be detected and the power halted stopping the motor from further movement. For additional safety, in the unlikely event of a thermal runaway condition, a thermal disconnect is used to remove power from the solid state outputs. Local electronic override capabilities allow independent operation of the device loads. Key Features Relays switch polarities to drive motors in both directions. Local electronic override operation. 35A inrush capable. Current sensing of loads. LEN value 2. Design Specifications Shock: Mil Std 202 Method 213 test condition 1. Vibration: Tested to Lloyds Register Approval Vibration Test 2. Transient voltage suppression: EN6100-6-1. Moisture resistance: IP66. PCB characteristics: UL94V-0. Power distribution: UL 1077 compliant (except highvoltage dielectric test). Ignition protection: UL 1500 compliant. Salt spray: Tested to Lloyds Register Approval Salt Spray Test. Operating Temperature: -40 C to 60 C. Storage Temperature: -40 C to 85 C. Operating Humidity: 0% to 100% (condensing). Weight: 0.86 lb (390 grams).

Electrical Specifications Description Min Nominal Max Absolute Max (Surge) Voltage 7 VDC 12 / 24 VDC 32 VDC 45 VDC 2 Current, Total 0.025 A 16 A 1 33 A 2 Current, per channel continuous 0 5 A 70 A 4 Current, per channel intermittent duty 3 0 8 A 70 A 4 Inrush capable per channel 35 A 70 A 4 Lead inductance 0 100 µh 5 Load Inductance 6 0 15 mh Trip Speed Characteristics NOTES: 1. De-rate max current by 0.2A per C above ambient, 25 C. 2. Measured at 8.3ms single half sine wave. (JEDEC Method), 10,000 pulses. 3. Duty cycle at 1 minute on time, 5 minutes off. Trip delay must be set to maximum rating. 4. Single pulse only. 5. Specified as 50 feet of 2 AWG (43mm2) wires with a 6 diameter spool for both power and ground. 6. For resistance greater than 10 ohms load inductance is unlimited.

Wiring Specifications Pin # Pin Description A1 Motor 2- E1 Motor 2+ B1 Motor 1- F1 Motor 1+ C1 E-Plex Data Bus + G1 E-Plex Data Bus D1 E-Plex Data Bus + H1 E-Plex Data Bus M5-T1 Batter Power M5-T2 Battery Return Outputs and Returns: 0 to 8A, 7-32VDC Battery Power (+): 0.025A to 16A, 7-32VDC Status LEDs: ON - Channels 1-4 indicates Load ON, E-Plex channel indicates module responding. OFF - Channels 1-4 indicates Load OFF, E-Plex channel indicates module not responding³. BLINKING - Channels 1-4 indicates Load FAULT, E-Plex channel indicates module responding. Power / Battery Connections: Must be fused at a maximum of 16A. Maximum wire size should be sized based on upstream fuse. When connecting the power source to the power studs on the module, torque the hex nuts to 18~20 in-lb (200~225 N-cm). Failure to properly torque hex nuts may result in intermittent operation due to terminals loosening over time. Note: External surge suppression is required when the module battery supply cable is longer then 50. Reversed Battery Conditions: The loads will turn on, but no damage will occur to the module if disconnected within 1 minute (Under nominal operating load conditions).

Pin Specifications Cable Range AWG (mm 2 ) Female Terminal Terminal Insulation Range 18-16 (1.0-0.75 mm 2 ) 15304716 1.70-2.25 mm 16-12 (2.50-1.50 mm 2 ) 15304717 2.20-3.00 mm Seal Insulation Range Seal P/N 1.20-1.85 mm 15366063 1.85-2.25 mm 15356064 2.09-2.66 mm 15366061 2.70-3.2 mm 15336674 Typical Wiring Diagram Ch. 4 M5 - T2 Ch. 3 Status LEDs, Channels 1-4 and E-Plex 3 M5 - T1 A1 E1 B1 F1 Motor Motor E-Plex Ch. 2 H1 C1 D1 E-Plex + E-Plex G1 E-Plex E-Plex + Ch. 1 Channels 1-4, Override Switches 1,2 Fuse / Disconnect, maximum 16A 12VDC or 24VDC, Battery Power + Battery Return (Ground) NOTES: 1. Switch is meant to be used as local electronic manual override in emergency situations. 2. Function may be defined in E-Logic as toggle or momentary operation. 3. LED will be off if system is not functioning / present however manual overrides will still function

Dimensional Diagram 125.91mm [4.96 ] 37.64mm [1.48 ] 41.40mm [1.63 ] Ø 5.8mm [0.23 ] x2 5.59mm [0.22 ] 11.68mm [0.46 ] 12.95mm [0.51 ] 97.03mm [3.82 ] 56.97mm [2.24 ] 2.23 [56.64] 5.08mm [0.20 ] 31.24mm [1.23 ] 13.72mm [0.54 ] 24.89mm [0.98 ] 63.50mm [2.50 ] 113.28mm [4.46 ] 39.12mm [1.54 ]

Mounting Specifications Screw assembly to a flat mounting surface in two places, as shown in the illustration. Mounting Instructions Metric fasteners: Use M5 size screw, M5 split lock washer and M5 washer. Torque to 250~280 N-cm. Do not exceed this torque as it could cause damage to the electronics. Imperial (English) fasteners: Use #10 size screw, #10 split lock washer, #10 washer. Torque to 20~22 in-lb. Do not exceed this torque as it could cause damage to the electronics. Mechanical Specifications Connectors: J1 - Brown: Mates to Delphi P/N 15317308 J2 - Blue: Mates to Delphi P/N 15317304 Cavity Plug: Delphi P/N 12059168 Power Stud Connections: M5 nickel plated brass Ordering Information Description 425DRM Series - Quad Multi Module E-Plex Part Number EP-SW-REV-2CH-425DRM

Powering Systems - Empowering Designers 52 54 Riverside, Sir Thomas Longley Road, Medway City Estate, Rochester, Kent ME2 4DP tel: +44 (0)1634 711622 fax: +44 (0)1634 290773 email: sales@e-plex.co web: www.e-plex.co Important Notice: E-Plex Ltd. (E-Plex) reserves the right to make changes to or discontinue any product or service identified in this publication without notice. E-Plex advises its customers to obtain the latest version of the relevant information to verify, before placing any orders, that the information being relied upon is current. E-Plex assumes no responsibility for infringement of patents or rights of others based on E-Plex applications assistance or product specifications since E-Plex does not possess full access concerning the use or application of customers products. E-Plex also assumes no responsibility for customers product designs.