Electronic timer CT-SDE Star-delta change-over with 1 n/c + 1 n/o contact

Similar documents
Electronic timer CT-EBE Flasher starting with OFF, 1 c/o (SPDT) contact

Electronic timer CT-AHE OFF-delayed with 1 c/o (SPDT) contact

Electronic timer CT-YDE Star-delta change-over with 1 c/o (SPDT) contact

Electronic timer CT-AWE Impulse-OFF with auxiliary voltage, 1 c/o (SPDT) contact

Three-phase monitoring relay CM-PVE

Three-phase monitoring relays CM-PFE and CM-PFE.2

Electronic timer CT-TGD.12 Pulse generator with 1 c/o (SPDT) contact

Electronic timer CT-SDS.22

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-WBS.22 Impulse generating and flashing with 2 c/o (SPDT) contacts

Three-phase monitoring relays CM-PSS CM-PSS.31 and CM-PSS.41

Three-phase monitoring relays CM-PVS.81

Voltage monitoring relays CM-ESS.1 for single-phase AC/DC voltages

Current monitoring relays CM-SRS.2 for single-phase AC/DC currents

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Current monitoring relays CM-SRS.1 for single-phase AC/DC currents

Three-phase monitoring relay CM-PBE

Electronic timer CT-AHS.22 OFF-delayed with 2 c/o (SPDT) contacts

Voltage monitoring relays CM-ESS.M For single-phase AC/DC voltages

Current monitoring relays CM-SRS.M1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.1 For single-phase AC/DC currents

Current monitoring relays CM-SRS.2 For single-phase AC/DC currents

Voltage monitoring relays CM-ESS.2 For single-phase AC/DC voltages

Electronic timer CT-SDD.22

Three-phase monitoring relay CM-PFS

Liquid level monitoring relay CM-ENS.2x

Voltage monitoring relay CM-EFS.2 For single-phase AC/DC voltages

Three-phase monitoring relays CM-PVS CM-PVS.31, CM-PVS.41 and CM-PVS.81

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23

Electronic timer CT-SDS.22 Star-delta change-over with 2 n/o contacts Data sheet

Temperature monitoring relays CM-TCS Monitoring relays for monitoring temperatures with a PT100 sensor (2- or 3-wire connection)

Multifunctional three-phase monitoring relays CM-MPN CM-MPN.52, CM-MPN.62 and CM-MPN.72

ABB 1. Multifunctional three-phase monitoring relays. CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. Features. Approvals. Marks.

Electronic timer CT-MBS.22 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-MVS.12 Multifunctional with 1 c/o (SPDT) contact

Three-phase monitoring relay

ABB 1. Multifunctional three-phase monitoring relays. CM-MPN.52, CM-MPN.62 and CM-MPN.72 Data sheet. Features. Approvals. Marks.

Electronic timer CT-MFS.21

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Electronic timer CT-MVS.23 Multifunctional with 2 c/o (SPDT) contacts

Electronic timer CT-TGD.22

Electronic timer CT-MXS.22 Multifunctional with 2 c/o (SPDT) contacts

Multifunctional three-phase monitoring relays CM-MPS CM-MPS.23 and CM-MPS.43

Electronic timer CT-SDE

Three-phase monitoring relays

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

ABB NEW. Three-phase monitoring relays. CM-PVS.31 and CM-PVS.41 Data sheet. Features J. Approvals. Marks. Order data. Order data - Accessories

Electronic timer CT-MFS.21 Multifunctional with 2 c/o (SPDT) contacts

CM-MPS.11, CM-MPS-21, CM-MPS.31 and CM-MPS.41 Data sheet. UL 508, CAN/CSA C22.2 No.14 GL GOST CB scheme CCC

Power supply CP-T 48/20.0 Primary switch mode power supply

Insulation monitoring relay CM-IWS.2 For unearthed AC systems up to U n = 400 V AC

Power supply CP-D 12/2.1

ABB NEW. Multifunctional three-phase monitoring relays. CM-MPS.23 and CM-MPS.43 Data sheet. Features J. Approvals. Marks.

Measuring and monitoring relays CM-SRS.1 Current monitoring relays, single-phase AC/DC

Power supply CP-T 24/20.0 Primary switch mode power supply

Three-phase monitoring relay

Electronic timer CT-ERS ON-delayed with 2 c/o contacts Data sheet

Type CP-S, CP-C & CP-A Switch mode

Power supply CP-T 48/5.0 Primary switch mode power supply

Electronic timer CT-AWS Impulse-OFF with 1 c/o contact Data sheet

Power supply CP-T 24/10.0 Primary switch mode power supply

Insulation monitoring relay CM-IWN.5 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Coupling unit CM-IVN For expansion of the insulation monitoring relay CM-IWN.x measuring range up to U n = 690 V AC and 1000 V DC

Power supply CP-T 24/40.0 Primary switch mode power supply

Power supply CP-D 24/4.2 Primary switch mode power supply

CP-E range Benefits and advantages

CP-T range Product group picture

Insulation monitoring relay CM-IWN.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

CP-T range Benefits and advantages

Pluggable interface relays CR-U Universal relays

Insulation monitoring relays CM-IWN.4/5/6 For unearthed AC, DC and mixed AC/DC systems up to U n = 400 V AC and 600 V DC

Power supply CP-E 24/2.5

Power supply CP-E 24/20.0

Three-phase monitoring relays Product group picture

Insulation monitoring relay CM-IWS.1 For unearthed AC, DC and mixed AC/DC systems up to U n = 250 V AC and 300 V DC

Primary switch mode power supplies Product group picture

Power supply CP-E 24/0.75

Three-phase monitoring relays Table of contents

Three-phase monitoring relays Product group picture

Thermistor motor protection relays

Power supply CP-E 24/2.5

Power supply CP-E 48/5.0 Primary switch mode power supply Data sheet

Power supply CP-E 12/10.0 Primary switch mode power supply Data sheet

Power supply CP-D 24/1.3

Control module CP-A CM

Thermistor motor protection relays

s s s 3-60 s min min 3-60 min h h 3-60 h V AC, 50/60 Hz

Analog signal converters CC-E I/I

Analog signal converters CC range

V2UM230V10 Art.Nr.: V2UM230V10P Art.Nr.: Control elements. Tripping delay. Function selector. Status indication 230 V AC/DC

Moeller Electric Corporation

DATASHEET - ETR4-70-A. Delivery program. Timing relay, 2W, 0.05s-100h, multi-function, VAC/DC, potentiometer connection

Liquid level monitors and controls

DATASHEET - ETR4-51-A. Delivery program. Technical data General. Timing relay, star-delta, 50 ms, 1W, 3-60s, VAC/DC

Type: EASY719 AC RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 115/230 V AC. Description

Subject to changes 11/2003 Page 1/7

VEO. V2PF480Y/277VS01 Art.Nr.: B TECHNICAL DATA

3RF A A 0 2. Switching function. Control voltage Operating voltage with heat sink 10 = 10.5 A. A = Zero-point switching

Control module CP-A CM

Type: EASY719 DA RC Article No.: Ordering information Relay outputs Quantity 6 Power supply V DC 12 V DC. Description

Transcription:

Data sheet Electronic timer CT-SDE Star-delta change-over with n/c + n/o contact The CT-SDE is an electronic time relay with star-delta change-over. It is from the CT-E range. The CT-E range is the economic range of ABB s time relays and offers a cost effective price-performance ratio for OEM users. This is achieved by simplified functionality and results in the simplest of setup procedures. The CT-E range is ideally suited for repeat applications. CDC 09 F000 Characteristics versions: single time range (0.-0 s) and different rated control supply voltage ranges ( V AC/DC / 0-0 V AC, 0-0 V AC and 80- V AC) Single-function timer with star-delta change-over Starting time (star) adjustable Transition time 0 ms fixed n/c and n/o contact with common contact. mm (0.89 in) width LEDs for the indication of operational states Order data Type Rated control supply voltage Time range Order code CT-SDE 0-0 V AC 0.-0 s SVR 0 0 R00 V AC/DC, 0-0 V AC SVR 0 7 R00 80- V AC SVR 0 R00

Functions Operating controls Indication of operational states U: green LED Control supply voltage applied R: red LED Output relay energized Thumbwheel for the fine adjustment of the starting time CDC 09 F000 Application Their conception makes the CT-E range timers ideal for repeat applications. Operating mode The fine adjustment of the time delay is made via the front-face thumbwheel. Examples of application L F L L L F S 0 9 9 -F I S KT K KT 8 K K -K -K -K K K -F 97 98 9 9 N KT B A A K A A A K K A A A Y N CDC 00 F00 W V U -M M ~ W V U CDC 009 F00 Star delta change over, control circuit diagram Star delta change over, power circuit diagram - Electronic timer CT-SDE Data sheet

Function diagram F Star-delta change-over (Star-delta starting) Applying control supply voltage energizes the star contactor (K) and the line contactor (K) and begins the set starting time. When the starting time is complete, contact - de-energizes the star contactor (K). Now, the fix transition time starts. When the transition time is complete, contact -8 energizes the delta contactor (K). A-A/B -8 - green LED red LED Star contactor Delta contactor t t CDC F00 t = adjustable starting time t = fixed transition time of 0 ms Electrical connection A A A-A Rated control supply voltage U s : Depending on device 0-0 V AC: SVR 0 0 R00 80- V AC: SVR 0 R00 - n/c contact -8 n/o contact with common contact A 8 8 A CDC F000 Connection diagram SVR 0 0 R00 and SVR 0 R00 A A B A-A Rated control supply voltage U s : 0-0 V AC A-B Rated control supply voltage U s : V AC/DC - n/c contact -8 n/o contact with common contact A B 8 8 A CDC F000 Connection diagram SVR 0 7 R00 Data sheet Electronic timer CT-SDE -

Technical data Data at T a = C and rated values, unless otherwise indicated Input circuits Supply circuit Rated control supply voltage U s A-A 0-0 V AC A-A 0-0 V AC A-A 80- V AC A-B V AC/DC Rated control supply voltage U s tolerance -...+0 % Rated frequency AC/DC version DC or 0/0 Hz AC version 0/0 Hz Typical current / power consumption V AC/DC approx..0 VA/W 0-0 V AC approx..0 VA 0-0 V AC approx..0 VA 80- V AC approx..0 VA Release voltage > 0 % of the minimum control supply voltage Timing circuit Starting time 0. - 0 s Star-delta transition time 0 ms fixed Recovery time < 00 ms Repeat accuracy (constant parameters) Dt < % Accuracy within the rated control supply voltage tolerance Dt < 0. % / V Accuracy within the temperature range Dt < 0. % / C Setting accuracy of time delay ± 0 % of full-scale value User interface Indication of operational states Control supply voltage U: green LED V: control supply voltage applied Relay status R: red LED V: output relay energized Output circuit Kind of output -, -8 relay, n/c and n/o with common contact Contact material silver alloy Rated operational voltage U e 0 V Minimum switching voltage / current V / 00 ma Maximum switching voltage / current see Load limit curves Rated operational current I e AC- (resistive) at 0 V A AC- (inductive) at 0 V A DC- (resistive) at V A DC- (inductive) at V A AC rating (UL 08) Utilization category (Control Circuit Rating Code) B 00 max. rated operational voltage 00 V AC Maximum continuous thermal current at B00 A max. making/breaking apparent power at B00 00 VA / 0 VA Mechanical lifetime 0 x 0 switching cycles Electrical lifetime AC-, 0 V, A 0. x 0 switching cycles Frequency of operation with/without load 0/7000 - Maximum fuse rating to achieve n/c contact 0 A fast short-circuit protection n/o contact 0 A fast - Electronic timer CT-SDE Data sheet

General data MTBF on request Duty time 00 % Dimensions see Dimensional drawings Weight net weight SVR00R00 0.08 kg (0.0 lb) SVR07R00 0.077 kg (0.70 lb) SVR0R00 0.079 kg (0.7 lb) gross weight SVR00R00 0.079 kg (0.7 lb) SVR07R00 0.089 kg (0.9 lb) SVR0R00 0.090 kg (0.98 lb) Mounting DIN rail (IEC/EN 07), snap-on mounting without any tool Mounting position any Minimum distance to other not necessary units Material of housing lower section UL 9 V-0 upper section UL 9 V- Degree of protection housing IP0 terminals IP0 Electrical connection Connecting capacity fine-strand with wire end ferrule x 0.7-. mm ( x 8- AWG) fine-strand without wire end ferrule x -. mm ( x 8- AWG) rigid x 0.7-. mm ( x 8- AWG) Stripping length 0 mm (0.9 in) Tightening torque 0.-0.8 Nm (.-7.08 lb.in) Environmental data Ambient temperature ranges operation -0...+0 C storage -0...+8 C Relative humidity range x h cycle, 0 C, 9 % RH Vibration, sinusoidal IEC/EN 008-- 0 m/s², 0-8/0-0 Hz Shock, half-sine IEC/EN 008--7 0 m/s², ms, shocks/direction Isolation data Rated insulation voltage U i between all isolated circuits Control supply voltage up to 0 V: 00 V Control supply voltage up to 0 V: 00 V Rated impulse withstand voltage U imp between all isolated circuits kv /.-0 μs Power frequency withstand voltage between all isolated circuits. kv, 0 Hz, min. (test voltage) Basic insulation (IEC/EN 0) input/output 00 V Protective separation (IEC/EN 0, EN 078) input/output - Pollution degree Overvoltage category III Standards / Directives Standards IEC/EN 8- Low Voltage Directive 0//EU EMC Directive 0/0/EU RoHS Directive 0//EU Data sheet Electronic timer CT-SDE -

Electromagnetic compatibility Interference immunity to IEC/EN 000-- electrostatic discharge IEC/EN 000-- Level ( kv / 8 kv) radiated, radio-frequency, IEC/EN 000-- 0 V/m ( GHz), V/m ( GHz), V/m (.7 GHz) electromagnetic field electrical fast transient / burst IEC/EN 000-- Level ( kv / khz) surge IEC/EN 000-- Level ( kv L-L) conducted disturbances, IEC/EN 000-- Level (0 V) induced by radio-frequency fields Interference emission IEC/EN 000-- high-frequency radiated IEC/CISPR, EN 0 Class B high-frequency conducted IEC/CISPR, EN 0 Class B Technical diagrams Load limit curves V V 00 00 V V 00 00 00 80 0 0 0 0 00 80 0 0 0 0 0 0 0 0. 0. 0. 0 I A CDC 9 F00 0 0. 0. 0. 0 I A CDC 9 F00 AC load (resistive) DC load (resistive) F.0 0.9 0.8 0.7 0. 0. 0. 0. 0. 0. 0. 0. 0.7 0.8 0.9.0 cos ϕ CDC 9 F00 0 9 8 N 0 Contact lifetime /switching cycles N 0 V 0 Hz AC, 0 cycles/h 7 8 I A CDC 0 F008 CDC 9 F00 Derating factor F for inductive AC load - Electronic timer CT-SDE Data sheet

Dimensions in mm and inches 88,.8 8.9,.88 78.07 78,.09 CDC 89 F000 Further documentation Document title Document type Document number Electronic relays and controls Catalog CDC 0 00 C0xx You can find the documentation on the internet at www.abb.com/lowvoltage -> Automation, control and protection -> Electronic relays and controls -> Time relays. CAD system files You can find the CAD files for CAD systems at http://abb-control-products.partcommunity.com -> Low Voltage Products & Systems -> Control Products -> Electronic Relays and Controls. Data sheet Electronic timer CT-SDE - 7

Contact us ABB STOTZ-KONTAKT GmbH P. O. Box 0 80 900 Heidelberg, Germany Phone: +9 (0) 7 0-0 Fax: +9 (0) 7 0- E-mail: info.desto@de.abb.com You can find the address of your local sales organisation on the ABB home page http://www.abb.com/contacts -> Low Voltage Products and Systems Document number CDC 7 D00 (0.07) Note: We reserve the right to make technical changes or modify the contents of this document without prior notice. With regard to purchase orders, the agreed particulars shall prevail. ABB AG does not accept any responsibility whatsoever for potential errors or possible lack of information in this document. We reserve all rights in this document and in the subject matter and illustrations contained therein. Any reproduction, disclosure to third parties or utilization of its contents in whole or in parts is forbidden without prior written consent of ABB AG. Copyright 07 ABB All rights reserved