LH630 LH635 LH1035. Operating Instructions Mode d emploi Bedienungsanleitung Istruzioni per il funzionamento Instrucciones de Funcionamiento

Similar documents
LH240 LH1040 LH2040 LH2015

USER'S MANUAL ACDC-100 TRMS ACDC-100. Versatile AC/DC Clamp-on Multimeter Series

AC/DC CLAMP METER USER S MANUAL

USER'S MANUAL. ACD-6 Pro. ACD-6 TRMS Pro. Versatile Clamp-on Multimeter Series

DC/AC CLAMP METER ISO-TECH 2000 USERS MANUAL

INSTRUCTION MANUAL ACD-10 PRO & TRMS PRO

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com # # AAC Clamp Meter. Instruction Manual

NOTE: Fully read and understand this manual before using this Digital Multimeter.

User Manual Digital Clamp Multimeter. model no.: MSR-C600

Instruction Manual ICM 135R Electrical Clamp Multimeter EN FR IT DE ES

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL: MODEL: Multimeter Service Information

Digital Clamp Meter Model: &

BENNING. CM7 Electrical Tester. Service Information

User s Guide. 400A AC/DC Clamp Meter. Model MA220

200Amp AC Clamp Meter + NCV Model MA250

AC/DC Clamp Meter. Owner's Manual. Model No Safety Operation Maintenance Español

CM605. User Manual AC/DC LOW CURRENT CLAMP-ON METER ENGLISH

User Guide. Digital AC/DC Clamp Meter Model 38394

ICM 136R Operating Instruction Electrical Clamp-Multimeter

User s Guide. Digital AC/DC Clamp Meter Model 38394

MS2030 CAT III 600 V A V AUTO RS232

INSTRUCTION MANUAL IDM17 PEN-TYPE MULTIMETER

USER'S MANUAL DMR-6700

AC / DC STROOMTANG MULTIMETER NI 30 AC / DC CLAMP MULTIMETER NI 30. Handleiding / Manual

312, 316, 318. Clamp Meter. Users Manual

MW3105 DIGITAL CLAMP MULTIMETER

Pen-type DIGITAL MULTITESTER

1. SAFETY 1.1. SAFETY INFORMATION 1.2. SAFETY SYMBOLS

Instruction Manual ICM 3091N Digital AC Clampmeter EN FR IT DE ES

AM-510 Commercial / Residential Multimeter. AM-510-EUR Digital Multimeter. Users Manual

User's Guide. 800 Amp AC/DC True RMS Clamp Meter. Model EX Washington Street Melrose, MA Phone Toll Free

600A Clamp Meters w/tightsight Display

USER MANUAL 600A AC Clamp Meter + NCV Model MA610

UT207A/208A/209A Operating Manual. Table of Contents

DVM645BI BENCH MULTIMETER TAFELMULTIMETER MULTIMETRE DE TABLE BANCO MULTÍMETRO TISCHMULTIMETER. User Manual. Gebruikershandleiding

36 AC/DC True RMS. Clamp Meter. P Read First: Safety Information

IDEAL INDUSTRIES, INC. TECHNICAL MANUAL MODEL:

USER'S MANUAL AM-100 AM-105 TRMS AM-110 TRMS. Digital Multimeters

User s Manual. MiniTec TM Series. Model MN26 (Model MN26T includes temperature probe) Mini Autoranging MultiMeter

DM-45 Digital Multimeter

OPERATOR S INSTRUCTION MANUAL DIGITAL MULTIMETER

400Amp True RMS AC Clamp Meter + NCV

TRMS LEAKAGE CURRENT CLAMP-ON METER 565

AC68C. Users Manual. True RMS AC/DC Clamp Multimeter. PN July Amprobe Test Tools. All rights reserved.

User s Guide. 400A AC/DC Clamp Meter. Model MA Washington Street Melrose, MA Phone Toll Free

DVM98. True RMS Digital Multimeter. 1 Safety information. 1.1 Preliminary. 1.2 During use

2000 A AC TRUE RMS DIGITAL CLAMP METER WITH NON-CONTACT EF-DETECTION

Safety. This symbol, adjacent to a terminal, indicates that, under normal use, hazardous voltages may be present.

270 manual.qxd 5/9/2005 3:04 PM Page 1. Digital Clamp-on Meter Instruction Manual

Thank you again for choosing AstroAI, if you have any questions or concerns regarding your product, please contact us at

30XR-A Professional Digital Multimeter Users Manual

DM-46 Instruction Manual

MM V 10A ENGLISH. INSTRUCTION MANUAL Auto-Ranging DATA HOLD AUDIBLE CONTINUITY MIN / MAX TEMPERATURE DIODE TEST CAPACITANCE

AM-500 Autoranging Mulitmeter. AM-500-EUR Digital Multimeter. Users Manual

USER'S MANUAL TBM061 TBM062 TBM063 TBM065

Model 77 Series IV. Digital Multimeter. Users Manual

MM700. True RMS ENGLISH. INSTRUCTION MANUAL Auto-Ranging. Measurement Technology

400Amp True RMS AC/DC Clamp Meter Model EX613

OPERATOR S INSTRUCTION MANUAL

Instruction Manual ICM A9 Electrical Clamp Multimeter EN FR IT DE ES

CONTENTS MS2033A. 1.Introduction Safety Information...01

Autoranging Multimeter Extech EX503

MM700. INSTRUCTION MANUAL Auto-Ranging Digital Multimeter True RMS

Table of Contents Title Page

BENNING. Service Information MODEL: MM1-1 / MM1-2 / MM1-3

1. SAFETY INFORMATION.1 2. DESCRIPTION SPECIFICATIONS.6 4. OPERATING INSTRUCTION Voltage measurement Current measurement 10

2000 A DCA/ACA CLAMP + DMM,

AMM-1022 Digital Multimeter USER`S MANUAL

CL900. True RMS 1000V 2000A 60MΩ ENGLISH. INSTRUCTION MANUAL 2000A Digital Clamp Meter. Measurement Technology

OPERATOR S INSTRUCTION MANUAL

DL6508 User's Guide. 1500Amp True RMS AC/DC Clamp Meter

Compact Autoranging Clamp Meters. Models (400 A AC), (400 A AC/DC)

Model UT201/202: OPERATING MANUAL. Table of Contents

1587/1577. Insulation Multimeters. Technical Data. Two powerful tools in one.

Pince Multimètre - Courants de fuites Leakage Clamp-on Meter Multimeter und Fehlerstrom-Messzange Pinza Multimetro - Correnti di fuga

79/26 Series III Multimeter

ET-3888 True RMS Clamp Meter. User Manual

AC/DC DIGITAL CLAMP METER OPERATION MANUAL

USER'S MANUAL. ACD-16 Pro ACD-16 TRMS Pro ACD-40PQ

Not for Reproduction

Multifunction Digital

DIGITAL DUAL DISPLAY AC/DC CLAMP METER MODEL-860A OPERATION MANUAL

DM-46 Instruction Manual

Dawson DDM190. Digital Multimeter User s Manual

KMD-S04 Multímetro de bolsillo

175, 177, 179. True-rms Multimeters. Users Manual

80i-110s AC/DC CURRENT PROBE

MS8268 HANDHELD DIGITAL MULTIMETER OPERATOR S INSTRUCTION MANUAL

2,000 counts, 200 Amp ACA/DCA, 600 V ACV/DCV, True RMS, OHMS, Continuity, Hold, Peak Hold FORK CURRENT TESTER. Model : FT-9950

INSTRUCTION MANUAL UTL260

CT238A. AC/DC Current Probe. User Manual. For detailed specifications and ordering info go to

CLAMP-ON METER 670. User Manual

Dawson DDM181. Pocket-Size Autorange Digital Meter User s Manual

User Manual Digital Multimeter

902 FC. HVAC True-rms Clamp Meter

Item ref: UK MTM01 DIGITAL MULTITESTER. User Manual

Fluke 345. Power Quality Clamp Meter. The ideal meter for commissioning and troubleshooting modern electrical loads

Instruction Manual IDM 61/62T Digital Multimeter EN DE ES IT FR

Digital Clamp Meter (TRMS) Model : 2727

DVM1190 DIGITAL MULTIMETER

Transcription:

LH630 LH635 LH1035 AC/DC Clamp On Multimeters Pinces Multimétriques AC/DC AC/DC Zangen-Multimeter Multimetri tenaglia c.a./c.c. Multímetros de incerción de C.A./C.C. Operating Instructions Mode d emploi Bedienungsanleitung Istruzioni per il funzionamento Instrucciones de Funcionamiento

CONTENTS Page 1 INTRODUCTION... 2 1.1 Instrument Features... 3 2 SPECIFICATION... 4 2.1 Electrical Data... 4 2.2 General Data... 6 3 OPERATING INSTRUCTIONS... 8 3.1 Current Measurement... 8 3.2 Resistance Measurement... 9 3.3 Voltage Measurement... 10 3.4 Diode Test... 10 4 SAFETY... 11 5 BATTERY REPLACEMENT... 12 6 WARRANTY... 13 7 OTHER PRODUCTS... 13 Issue 4. 14/01/97. 1. INTRODUCTION 1148

The advanced design of the LH30 Series AC/DC Clamp On Multimeters ensure reliable and accurate measurements under a wide range of operating conditions. Measurement features include: Non-intrusive AC/DC current LH635/1035. True RMS for complex and distorted currents LH630. Average responding, RMS calibrated AC/DC current component analysis Autoranging and Autozeroing AC/DC Volts Ohms, Continuity and Diode Test Max RMS (surge) Current and Voltage (LH635/1035) Data Hold The LH series of instruments conform to the latest international directives and standards concerning safety and electromagnetic compatibility. European Low Voltage Directives 73/23/EEC and 93/68/EEC European EMC Directives 89/336/EEC and 93/68/EEC Submitted for approval to UL 3111-1 Safety Standards IEC 1010-1 : 1992-09 Safety requirements for electrical equipment for measurement, control and laboratory use. Part 2-032 : 1994-12 Particular requirements for hand held current clamps for electrical measurement and test. Part 2-031 : 1993-02 Particular requirements for hand held probe assemblies for electrical measurement and test. 600V Cat III Pollution degree 2 EMC Standards RF Susceptibility EN 50082-1 : 1992 3V/m Residential, Commercial and Light Industry RF Emissions EN 50081-1 : 1992 Residential, Commercial and Light Industry FCC Part 15 Class B 1.1 Instrument Features 2148

The main operating features of the instrument are as follows. See Fig. 1. (1) Clamp-on jaws for current measurement (2) Jaw opening lever (3) Rotary switch for function selection (4) Push button switch for MAX / )))) selection. (MAX: LH635/1035) MAX holds the maximum RMS value when in the current or volts mode. )))) selects continuity buzzer when in Ohms mode (5) Push button switch for display HOLD (6) and (7) - Test lead input terminals Fig. 1 Instrument Features 2. SPECIFICATION 2.1 Electrical data 3148

(All accuracies stated at 23 C ± 1 C) 2.1.1 Current measurement LH1035 (DC, ACRMS) Measuring range... 0-1500A DC 0-1000A AC RMS Autorange facility... 400A / 1500A Resolution... 100mA in 400A range 1A in 1500A range Accuracy I > 10A... ± 1.9% rdg ± 3 digits I 10A... ± 1A Frequency range... DC in DC 15Hz to 1kHz in ACRMS Frequency characteristics above 1kHz Signal Amplitude... -3dB @ 5kHz -6dB @ 10kHz Crest factor... 6 maximum Maximum overload... 10,000A or ACRMS x frequency < 400,000 Amps ACRMS is a true RMS measurement. LH635 (DC, ACRMS) Measuring range... 0-1000A DC 0-600A AC RMS Autorange facility... 400A / 1000A Resolution... 100mA in 400A range 1A in 1000A range Accuracy I > 10A... ± 1.3% rdg ± 3 digits I 10A... ± 0.5A Frequency range... DC in DC 15Hz to 1kHz in ACRMS Frequency characteristics above 1kHz Signal Amplitude... -3dB @ 5kHz -6dB @ 10kHz Crest factor... 6 maximum Maximum overload... 10,000A or ACRMS x frequency < 400,000 Amps ACRMS is a true RMS measurement. LH630 (DC, AC) Measuring range... 0-1000A DC 4148

0-600A AC Autorange facility... 400A / 1000A Resolution... 100mA in 400A range 1A in 1000A range Accuracy I > 10A... ± 1.3% rdg ± 3 digits I 10A... ± 0.5A Frequency range... DC in DC 15Hz to 400Hz in AC Maximum overload... 10,000A or AC x frequency < 400,000 Amps AC is average responding, sinewave calibrated. 2.1.2 Max RMS Current (LH635/1035) This function is actuated by pressing MAX/ )))) when in DC or ACRMS. No polarity indication is given for DC readings.typical acquisition time is 100ms Accuracy... I > 10A... ± 2% rdg ± 4 digits I 10A... ± 1A Frequency Range... DC and15 Hz to 1kHz in ACRMS Crest Factor... 6 maximum 2.1.3 Voltage measurement DC, AC (RMS on LH635/1035) Measuring range... 0-600V Autorange Facility... 400V / 600V Resolution... 100mV in 400V range 1V in 600V range Accuracy AC/DC... ± 1% rdg ± 3 digits AC 10V... ± 1% rdg ± 5 digits Frequency Range... DC in DC AC: LH 630 AC 15Hz to 400Hz LH 635/1035 ACRMS 15Hz to 1kHz Maximum Overload... 1000V Crest Factor... 6 maximum 2.1.4 Max RMS Voltage (LH635/1035) This function is activated by pressing MAX/ )))) when in DC or ACRMS. No polarity indication is given in DC. Typical acquisition time is 100mS Accuracy V > 10V... ± 2% rdg ± 4 d V 10V... ± 0.5V Frequency Range.... DC and 15 Hz to 1kHz in ACRMS 5148

Crest Factor... 6 maximum 2.1.5 Diode Test Measurement of the voltage drop across a forward biased diode. Measuring range... 0-2V Resolution... 1mV Accuracy... Input protection... ± 1% rdg ± 2 digits 600V (DC or sinewave RMS) 2.1.6 Resistance Measurement Measuring range... 0-4 kω Autorange Facility... 400Ω / 4kΩ Resolution... 100mΩ in 400Ω range 1Ω in 4kΩ range Accuracy... ± 1% rdg ± 3 digits Input protection... 600V (DC or sinewave RMS) 2.1.7 Continuity This function is actuated by pressing the MAX / )))) button when in Ω measurement. The buzzer will sound for values of resistance below approximately 50Ω. 2.2 General Data 2.2.1 Display Display 4000 count 12mm high characters. - + Low battery indicator Pk Max RMS Amps or Volts (LH635/1035) 6148

AC ---- DC Diode kω Ohms )))) Continuity H Hold 2.2.2 Power Supply Battery Type 9V Alkaline PP3,NEDA1604 or IEC 6LR61 Battery life typically 40 hours continuous operation. 2.2.3 Environmental FOR INDOOR USE ONLY Reference conditions. All accuracies stated at 23 C ± 1 C Temperature coeff. of current ± 0.1% of rdg per C Operating Temperature 0 C to 50 C (32 F to 122 F) Maximum Relative Humidity 80% for temperatures up to 31 C (87 F) decreasing linearly to 50% Relative Humidity at 40 C (104 F) Storage Temperature - 20 C to + 60 C (- 4 F to 140 F) Maximum operating altitude 2000m. 2.2.4 Mechanical Dimensions Length LH630/635... 230mm / 9.05 Length LH1035... 251mm / 9.88 Width 98mm / 3.86 Depth 52mm / 2.05 Weight... 500g / 1.1 lbs. Case Material... Bayblend T85MN Jaw Opening LH630/635... 35mm / 1.37 LH1035... 55mm / 2.2 Accessories... Voltage probes Carrying case Operators manual 7148

Cleaning... The unit can be cleaned with an isopropanol impregnated cloth. Do not use abrasives or other solvents. 3. OPERATING INSTRUCTIONS The instrument function is selected by a rotary switch with the following positions :- OFF V ---- V Ω A A ---- Instrument off Volts DC Volts AC (LH635/1035 - true RMS) Diode measurement Ohms measurement Amps AC (LH635/1035 - true RMS) Amps DC 3.1 Measurement of AC or DC current Remove any Voltage test leads from the instrument. Move the rotary switch to Amps AC or DC Wait until the autozero operation has completed and the display reads 000.0 Press the trigger to open the jaws and clamp them around the current carrying conductor as shown in Fig. 2 Read the display Use the HOLD button to freeze the display. Use the )))) / MAX button to measure the max RMS current (LH635/1035) Note that the Amps autozero is initiated by the movement of the rotary switch from the Ω position to the Amps measurement positions. If, after a high current measurement, the display does not return to zero, then a reautozero can be initiated by the movement of the rotary switch into and out of the Ω selection position. 8148

Fig. 2 Current Measurement 3.2 Resistance Measurement Insert the test leads into the sockets on the front of the instrument, the red lead to the VΩ terminal and the black lead to the COM terminal. Move the rotary switch to the Ω position. Apply the test leads across the component whose resistance is to be measured. Read the displayed value. Use the HOLD button to freeze the display. Use the )))) / MAX button to select the continuity facility. The buzzer will sound for resistance measurements below approximately 50Ω. 3.3 Measurement of AC or DC Voltage 9148

SAFETY WARNING To avoid possible electric shock and damage to the instrument, do not attempt to measure any voltage that might exceed the maximum range of the instrument - 600Vrms and 1kHz. Move the rotary switch to the VDC or VAC position Insert the test leads into the sockets on the front of the instrument. Connect the RED lead to the VΩ terminal and the black lead to the COM terminal. Apply the test leads to the circuit under test and read the displayed voltage. See Fig. 3 Use the HOLD button to freeze the display. Use the )))) / MAX button to measure the max RMS voltage (LH 635/1035) Fig. 3 Voltage Measurement 3.4 DiodeTest 10148

Insert the test leads into the sockets on the front of the instrument, the red lead to the VΩ terminal and the black lead to the COM terminal. Move the rotary switch to the position. Apply the test leads across the diode to be tested. Read the displayed value. Use the HOLD button to freeze the display. 4. SAFETY The instrument has been designed to comply with IEC1010-2-032 Installation Category (Overvoltage Category) III 600V Pollution degree 2 and UL 3111-1. The product range conforms with the EEC Low Voltage Directive 73/23/EEC and 93/68/EEC. IEC 1010 is a safety standard which has the following features: Installation categories I to IV relate the maximum working voltage to overvoltage transients that can be expected in the measuring environment. For the LH range of instruments, 600V CATIII, the maximum expected transients must not exceed 6kV peak. In a pollution degree 2 environment the internal design of the instrument can cope with transient conductivities due to condensation. Safe operation of the instrument is the responsibility of the operator who must be suitably qualified and/or authorised. Users of this equipment and or their employees are reminded that Health and Safety Legislation require them to carry out valid risk assessments of all electrical work so as to identify potential sources of electrical danger and risk of electrical injury such as from inadvertent short circuits. Where the assessments show that the risk is significant then the use of fused test leads constructed in accordance with the HSE guidance note GS38 Electrical Test Equipment for use by Electricians is advised. Maximum Safe Voltage Current :- 600V MAXIMUM AC RMS or DC between uninsulated conductor and ground and maximum frequency of 1kHz. This limitation applies to bare conductors only. Voltage:- 600V MAXIMUM AC RMS or DC between live conductor and ground. 600V MAXIMUM AC RMS or DC between VΩ and COM terminals and a maximum frequency of 1kHz. Important Information The instrument is intended for indoor use only. 11148

Do not attempt to take any measurement of current or voltage higher than the maximum range of the instrument. The unit is not hermetically sealed and should NOT be brought into contact with surface water. Frequently inspect the test leads and the instrument for damage. If the instrument is physically damaged or does not function properly, it should not be used. USE ONLY SUITABLY RATED VOLTAGE TEST LEADS TO IEC 1010-2-031. (600V CAT III Pollution Degree 2). 5. BATTERY REPLACEMENT Replacement with other than the specified battery will invalidate the warranty. Fit only Battery Type 9V Alkaline MN1604, IEC 6LR61 or equivalent. - + will appear on the top row of the LCD display to indicate that the minimum operating battery voltage has been reached. SAFETY WARNING Before removing the battery cover, make sure that all external voltages are disconnected from the instrument. For certainty remove the leads. To change the battery, see Fig. 4 Switch off the instrument Undo the retaining screw on the battery cover and lift the cover clear of the unit. Replace the used battery Ensure the battery cover is replaced and the locking screw tightened, before further use. 6. WARRANTY Fig. 4 12148

Your LEM HEME clamp on multimeter is guaranteed for one year from the date of purchase against defective material or workmanship. If the meter fails during the warranty period, we shall at our discretion, repair or replace it with a new or reconditioned unit provided we are satisfied that the failure is due to defective material or workmanship. To make a claim under warranty, the meter should be returned to us, postage prepaid, with a description of the defect. The use of a battery, other than that specified invalidates this warranty. Goods alleged by the buyer to be defective shall not form the subject of any claim for injury, loss, damage, or any expense howsoever incurred whether arising directly or indirectly from such alleged defects other than death or personal injury resulting from the seller s negligence. No condition is made or to be implied nor is any warranty given or to be implied as to the life or wear of goods supplied or that they will be suitable for any particular purpose or for use under specific conditions, notwithstanding that such purpose or conditions may be made known to the seller. 7. OTHER PRODUCTS The LEM group offer a wide range of non-invasive transducers, probes and instrumentation for the measurement and analysis of current, voltage and power. Since the introduction of the world s first digital AC/DC clamp-on ammeter in 1982, LEM HEME has continued to provide innovative test and measurement solutions encompassing current measurement from 5mA to 2000A. LEM HEME policy is one of the continuous product improvement and the company reserves the right to revise the above specifications without notice 13148

DECLARATION OF CONFORMITY Equipment Name/Type Number: LH630 / LH635 / LH1035 Manufacturer: LEM HEME LIMITED Address: 1 Penketh Place, West Pimbo, Skelmersdale, Lancashire, WN8 9QX. United Kingdom. European Standards: - EMC EN50082-1 : 1992 Generic Immunity Standard. Part 1. Residential, commercial and light industry. EN50081-1 : 1992 Generic Emission Standard. Part 1. Residential, commercial and light industry. Safety use:- EN61010-1 : 1993. General Requirements. Safety requirements for electrical equipment for measurement, control and laboratory IEC1010-2-032 : 1994-12. Particular requirements for hand held current clamps for electrical measurement and test. IEC1010-2-031 : 1993-12. Particular requirements for hand held probe assemblies for electrical measurement and test. Description of Equipment: AC/DC Clamp On Multimeter. I certify that the apparatus identified above conforms to the requirements of Council Directives:- (1) Electromagnetic Compatibility Directive 89/336/EEC (2) Low Voltage Directive 73/23/EEC (3) CE Marking Directive 93/68/EEC Signed: Name : BRIAN M. HOPKINS OPERATIONS DIRECTOR Date : 20/2/97 14148