User's Manual. ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R

Similar documents
Ex instruction manual. Rotamass Coriolis mass flow meter. IECEx. IM 01U10X02-00EN-R_002, 2nd edition,

Ex instruction manual. Rotamass Coriolis mass flow meter ATEX. IM 01U10X01-00EN-R_002, 2nd edition,

DPharp Differential Pressure and Pressure Transmitters

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Power supply. Calibration. Surface finishing. Seal. Process connection

Rev ECN Description Approval Date AA Release to Approvals RCS 10/9/12

Temperature Input Module for Zone 1 Series 9482/32

Analog Input Module HART Ex i / I.S. Inputs, Channels Type 9461/

IECEx Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Annex 1 to Certificate of Conformity IECEx KEM X Issue No. 8 Rota Yokogawa Rotamass 3 Series Coriolis Mass Flowmeter

INSTRUCTION MANUAL (ATEX / IECEx)

Pressure transmitters MBS 4201, MBS 4251, MBS 4701 and MBS 4751

Digital Input Module NAMUR Ex i / I.S. Inputs, 16 Channels for Zone 1 / Div. 1 Series 9470/22

OPTIWAVE 7300 C Supplementary instructions

Safety Instructions Nivotester FTC625, FTC325

Analog Universal Module HART for Zone 2 Series 9468/33

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 1.5 s adjustable. 20 ms. 60 ms. 60 ms. Approx. 1.

CoriolisMaster FCB130, FCB150, FCH130, FCH150 Coriolis Mass Flowmeter

Glass-fibre-reinforced polycarbonate. Dead zone Adaptive or fixed from % 20 ms. 60 ms. 60 ms. Approx. 1.3 kg. Approx. 0.9 kg. Approx. 5.

Transducer transmitter BILT 4 II 2(1) G. Technical Manual

General Specifications

Safety Instructions Proline Promag 500

Attachment to Certificate IECEx PTB X

Digital Input Output Module for Zone 2 Series 9470/33

Digital Input Output Module for Zone 2 Series 9470/33

2-WIRE UNIVERSAL TEMPERATURE TRANSMITTER

Rotamass TI Coriolis Mass flow meter

Digital Input Output Module for Zone 1 Series 9470/32

Installation guide 971 SmartRadar LTi

ATEX Installation Drawings and Instructions

Safety Instructions Proline Promass 300

PROline promag 53 Division 1

Intrinsically safe pressure transmitter MBS 4201, MBS 4251, MBS 4701 and MBS 4751

OPTITEMP TT 10 C/R Technical Datasheet

Solexy USA, LLC International Blvd Cincinnati, Ohio Phone: Fax:

[ Rosemount 648 Wireless Temperature Transmitter. Rosemount 648 Wireless. Quick Installation Guide , Rev CA August 2011

Rosemount 848L Logic Transmitter with FOUNDATION Fieldbus

Inductive sensor slot-type SI2-K08-AP7

Page 1 of 5 Attachment to IECEx TUN X Issue 0

Specifications. Specifications. Transfer Characteristics Accuracy at 20 C (68 F) Temperature Drift

Digital Input Output Module 24 V for Ex n Zone 2 Series 9472/35

Introduction. Additional Information. Temperature transmitter for HART protocol. Suitable for all standard requirements. Measurement made easy

Rudder or propeller angular position transmitter KINAX WT720

YTA610 and YTA710 Temperature Transmitters (Hardware)

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

Micro Motion Model 5700 Transmitter IECEx Zone 2/22 Installation Instructions EPL Gc and EPL Dc

Rotamass TI Coriolis Mass flow meter

Safety Instructions Proline Promass 100

Installation guide 877 FDI Field Display & Interface

Installation guide 970, 971 and 973 series SmartRadar

FLEX Ex V ac In/Quad-Ex dc Out Power Supply

YTA610 and YTA710 Temperature Transmitter (Hardware)

FLEX Ex Power Supplies

Proline Promass 40. Safety Instructions. NEPSI Zone 1, Zone 21

Isolators A3/1. Vibration Transducer Supply Unit Series

Miniature resistance thermometer Explosion-protected version Model TR34, thread-mounted

Mid-West. Instrument. Model 140 Electrical Installation and Operating Instructions. Gauge Front ELECTRICAL

Intrinsic Safety Control Drawing

Intrinsically Safe Compact Controller CTR 210i. Intrinsically Safe Bargraph Indicator. BGI 210i

PROCESS AUTOMATION MANUAL FIELDBARRIER

Expert 1400 / Expert 3400 Submersible Hydrostatic Level Transmitters

MT MOTORI ELETTRICI. Installation, operation, maintenance and safety manual for motors used in hazardous areas 1-II-2G 21-II-2D

Digital Input Module 24 V Ex n Inputs, 16 Channels Series 9471

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Description. Annexe to: IECEx CML X Issue 1. Isolating Amplifier D461

Installation guide 873 SmartRadar Control Unit & Antenna Unit

General Specifications

General Specifications

User manual. Load cell with one built in amplifier KOSD-FA KIMD-FA KEND-FA Load cell with two built in amplifiers KOSD-FAD KIMD-FAD KEND-FAD

OPTIMASS / 300 / 010 Guidelines for the use of Coriolis meters in hazardous areas

CSA Hazardous Area Approvals Fisher FIELDVUE DVC6005 Series Remote Mount Digital Valve Controllers

Proline Promass 83, 84

Certificate of Compliance

TÜV NORD CERT. TÜV NORD CERT GmbH & Co. KG Am TÜV 1 D Hannover. Annexe to IECEx TUN , issue No. 0 Page 1 of 5.

FM Hazardous Area Approvals Fisher FIELDVUE DVC6200 Series Digital Valve Controllers

Operator Manual. Transmitters Series KAT-... Analog transmitters in 2-wire technique

STT 3000 Series STT170 SMART TEMPERATURE TRANSMITTER Models STT171, STT173, STT17H, STT17F, STT17C

Remote I/O. 74 Remote I/O. Remote I/O System

Isolators A3/1.

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160 Rev. F

Process transmitter Model UPT-20, with pressure port Model UPT-21, with flush diaphragm

DMP 343. Industrial Pressure Transmitter. Without Media Isolation. appmeas.co.uk +44 (0)

Micro Motion Model 5700 Transmitter ATEX Zone 2/22 Installation Instructions II 3 G or II 3 (2) G/EPL Gc & II 3 D/EPL Dc

Installation guide 970 SmartRadar ATi

Binary Output without Power Supply Series 9176

SINEAX TI 807 Passive DC signal isolator. SINEAX TI 807 Passive DC signal isolator

Isolators A3/1. Ex i Power Supply Field Circuit Ex i Series

Field indicator for current loops with HART communication Models DIH50, DIH52

RHE11. Hazardous Area Multifunction Coriolis Flow Transmitter. Features. Applications. Benefits

Digital temperature transmitter for resistance sensors Model T15.H, head mounting version Model T15.R, rail mounting version

SINEAX TI 807 Passive DC signal isolator

CERTIFICATE OF COMPLIANCE

User s Manual. Manual Change No V-E. Please use the attached sheets for the pages listed below in IM 01F06F00-01EN (7th).

MFC 300 Handbook. Signal converter for mass flowmeters. Electronic Revision: ER 3.3.xx (SW.REV. 3.3x)

Installation Instructions P/N MMI , Rev. AA July ATEX Installation Instructions for Micro Motion Model RFT9739 Transmitters

Binary Output Series 9175

ProcessMaster / HygienicMaster

Installation guide 854 XTG Level Gauge

Isolators A3/1. Transmitter Supply Unit Field Circuit Ex i Series 9160

M224. M C bis. TYPE CODE M K Y 45 / 18 x 60 - / / / - #

Transcription:

User's Manual ROTAMASS Total Insight Coriolis Mass Flow and Density Meter Explosion Proof Type Manual IECEx IM 01U10X02-00EN-R IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Table of contents Table of contents 1 Introduction... 4 1.1 Scope of application... 4 1.2 Applicable documents... 4 1.3 Explanation... 4 2 Nameplates... 5 2.1 Sensor, integral type... 6 2.2 Transmitter, integral type... 7 2.3 Sensor, remote type... 8 2.4 Transmitter, remote type... 9 3 Ordering information... 10 3.1 Model code... 10 4 Installation... 11 4.1 General installation rules... 11 4.2 Threads for cable glands... 12 4.3 Flameproof transmitter threads... 15 5 Wiring... 16 5.1 General rules... 16 5.2 Grounding connections and intrinsically safe circuits... 17 5.3 Transmitter connection terminals... 18 5.3.1 Configuration for HART communication... 18 5.3.2 Configuration for Fieldbus communication... 20 5.3.3 Configuration for Modbus communication... 21 5.4 Installation diagrams... 23 5.4.1 Integral type without intrinsically safe I/O outputs... 23 5.4.2 Integral type with intrinsically safe I/O outputs... 24 5.4.3 Integral type for Fieldbus communication (intrinsically safe)... 25 5.4.4 Remote type without intrinsically safe I/O outputs... 26 5.4.5 Remote type with intrinsically safe I/O outputs... 28 5.4.6 Remote type for Fieldbus communication (intrinsically safe)... 30 6 Operation, maintenance and repair... 32 6.1 General rules... 32 6.2 Replacing the sensor... 33 6.3 Replacing the transmitter... 35 7 Approvals and standards... 37 8 Technical data... 38 8.1 Integral type... 39 8.2 Remote type... 41 8.2.1 Nano, CNG, LPG sensor... 41 8.2.2 Supreme, CNG, LPG, Intense and Giga sensor... 42 8.2.3 Prime and Hygienic sensor... 43 8.2.4 Transmitter... 44 8.2.5 Connecting cable... 46 8.2.6 Connection to Rotamass 3 sensor... 47 2 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Table of contents 8.3 Ex code... 48 8.3.1 Determining the maximum temperatures based on the Ex code... 48 8.4 specification by temperature classes... 53 8.4.1 Identification via MS code... 53 8.4.2 Identification via MS code and Ex code... 56 8.4.3 Rotamass Nano, CNG, LPG... 57 8.4.4 Supreme, CNG, LPG and Intense... 58 8.4.5 Rotamass Giga... 61 8.4.6 Rotamass Prime and Hygienic... 64 2018-02-23IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 3 / 70

Explosion Proof Type Manual IECEx Introduction Scope of application 1 Introduction 1.1 Scope of application These instructions apply to the following Rotamass Total Insight product families: Rotamass Nano Rotamass Supreme Rotamass Giga Rotamass Prime Rotamass Intense Rotamass Hygienic Rotamass CNG Rotamass LPG Rotamass Total Insight transmitter in combination with any Rotamass Total Insight sensor or Rotamass 3 sensor The availability of product families is defined by the applicable General Specifications. 1.2 Applicable documents The following documents are part of these instructions: Quick Reference User s Manual Software Instruction Manuals General Specifications 1.3 Explanation is used as a placeholder for a single character. 4 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Explosion Proof Type Manual IECEx Nameplates 2 Nameplates The sensor as well as the transmitter each contain a main nameplate and an additional nameplate that feature different information. NOTICE For individual applications (e.g. marine applications with option MC ) additional limitations to those on the nameplate may apply according to the respective applicable regulations. The variants of the nameplates are described below. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 5 / 70

Explosion Proof Type Manual IECEx Nameplates Sensor, integral type 2.1 Sensor, integral type Main nameplate 5 6 7 1 ES34S-50BD40-OE90-SF21-4-JA1 2 1234567 304/1.4301 2015 40bar 60bar 3 8 o -40 to +60 C 150 o C 4 i 12 11 10 9 1 MS code 2 Serial number 3 Year of manufacture 4 Ambient temperature range 5 Material wetted parts 6 Flow direction 7 Warning that requires reading of the documentation 8 Area for conformity marking 9 Manufacturer's address 10 Test pressure 11 Maximum allowed working pressure at room temperature 12 Maximum allowed process temperature Additional nameplate 1 3 4 5 2 7 6 1 Calibration constants of sensor 2 Customer-specific identification 3 Identification field for use according to Ex db or Ex db eb 4 Reference to documentation 5 Identification of type of protection, explosion group, temperature classes and equipment protection level 6 IP code 7 Ex code 6 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Transmitter, integral type Explosion Proof Type Manual IECEx Nameplates 2.2 Transmitter, integral type Main nameplate 1 2 3 4 5 ES34S-50BD40-OE90-SF21-4-JA1 1234567 i 2015 24VAC or 100...240VAC, 50/60Hz 24VDC or 100...120VDC; 10W -40...+60 o C 6 7 8 1 MS code 2 Serial number 3 Year of manufacture 4 Power supply range 5 Ambient temperature range 6 Warning that requires reading of the documentation 7 Area for conformity marking 8 Manufacturer's address Additional nameplate 1 3 4 2 5 1 Identification field for use according to Ex db or Ex db eb 2 Maximum r.m.s. a.c. or d.c. voltage 3 Reference to documentation 4 Identification of type of protection, explosion group, temperature classes and equipment protection level 5 IP code IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 7 / 70

Explosion Proof Type Manual IECEx Nameplates Sensor, remote type 2.3 Sensor, remote type Main nameplate 5 6 7 1 ES34S-50BD40-OE90-SF21-4-JA1 2 1234567 304/1.4301 2015 40bar 60bar 3 8 o -40 to +60 C 150 o C 4 i 12 11 10 9 1 MS code 2 Serial number 3 Year of manufacture 4 Ambient temperature range 5 Material wetted parts 6 Flow direction 7 Warning that requires reading of the documentation 8 Area for conformity marking 9 Manufacturer's address 10 Test pressure 11 Maximum allowed working pressure at room temperature 12 Maximum allowed process temperature Additional nameplate 1 2 3 4 5 1 Calibration constants of sensor 2 Customer-specific identification 3 Reference to documentation 4 Identification of type of protection, explosion group, temperature classes and equipment protection level 5 Ex code 6 IP code 6 8 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Transmitter, remote type Explosion Proof Type Manual IECEx Nameplates 2.4 Transmitter, remote type Main nameplate 1 2 3 4 5 ES34S-50BD40-OE90-SF21-4-JA1 1234567 i 2015 24VAC or 100...240VAC, 50/60Hz 24VDC or 100...120VDC; 10W -40...+60 o C 6 7 8 1 MS code 2 Serial number 3 Year of manufacture 4 Power supply range 5 Ambient temperature range 6 Warning that requires reading of the documentation 7 Area for conformity marking 8 Manufacturer's address Additional nameplate 1 3 4 2 5 1 Identification field for use according to Ex db or Ex db eb 2 Maximum r.m.s. a.c. or d.c. voltage 3 Reference to documentation 4 Identification of type of protection, explosion group, temperature classes and equipment protection level 5 IP code IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 9 / 70

Explosion Proof Type Manual IECEx Ordering information Model code 3 Ordering information 3.1 Model code The MS code of the Rotamass Total Insight is explained below. Items 1 through 14 are mandatory entries and must be specified at the time of ordering. Device options (item 15) can be selected and specified individually by separating them with slashes. 1. Transmitter 2. Sensor 3. Meter size 4. Material wetted parts 5. Process connection size 6. Process connection type 7. Sensor housing material 8. Process fluid temperature range 9. Mass flow and density accuracy 10. Design and housing 11. Ex approval 12. Cable entries 13. Communication type and I/O 14. Display 15. Options 10 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

General installation rules Explosion Proof Type Manual IECEx Installation 4 Installation 4.1 General installation rules DANGER Explosion hazard from electrostatic discharge or brush discharge Life-threatening injuries or ignition of explosive atmospheres Avoid actions that could lead to electrostatic discharges. For example, do not wipe the coated surface of the transmitter using a piece of cloth. Install the device in zone 1 or 21 so as to avoid the risk of electrostatic discharges and brush discharges caused by rapid dust flow. Modifying the coriolis mass flow meter as well as using unauthorized parts is prohibited and will void the certification. Only trained personnel may install and operate the device in an industrial environment. The instructions have to be read and understood by all persons authorized with the transport, storage, installation, electrical installation, commissioning, operation, maintenance and disposal of the Coriolis mass flow meter in hazardous areas. The respective applicable national safety regulations concerning the installation of the Coriolis mass flow meter in hazardous areas must be followed. Only media to which the wetted parts are sufficiently resistant may be used. The use of suitable cable glands must be ensured, see Threads for cable glands [} 12]. Ambient and medium temperature must not exceed the respective maximum values for the applicable specification by temperature classes [} 53]. The integral type and the remote-type transmitter must not be insulated. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 11 / 70

Explosion Proof Type Manual IECEx Installation Threads for cable glands 4.2 Threads for cable glands The terminal box in the transmitter for connecting the sensor is certified as Ex i. IP66/67- certified cable glands and blind plugs must be used for this connection. At a minimum, the allowable temperature range for cable glands and blind plugs must extend from -40 +80 C. Blind plugs for redundant bushings and cable glands are factory-installed. The housing of the transmitter is designed as type of protection Ex db. Optionally, the terminal box for the power supply and the inputs/outputs is also certified as Ex eb. Properly certified cable glands and blind plugs must be used for this purpose. At a minimum, the allowable temperature range for cable glands and blind plugs must extend from -40 +80 C. The type of protection is to be indicated on the nameplate's identification fields, see Nameplates [} 5]. If the device is to be operated without communication lines, properly classified and certified blind plugs must be installed. 1 2 3 M/N/W 4 5 Fig. 1: Threads for the cable glands of the transmitter 1 5 Thread position, see the following table M Marking of thread size: ISO M20 1.5 N or W Marking of thread size: ANSI 1/2" NPT 12 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Threads for cable glands Explosion Proof Type Manual IECEx Installation The following figure shows the relevant position of the MS code: Thread MS code Position 12 ISO M20 1.5 4 Thread position 1 2 3 4 5 Integral type Blind plug IP66/67, factoryinstalled Blind plug IP66/67, factoryinstalled Delivery state Remote type Metal cable gland IP66/67, factoryinstalled Blind plug IP66/67, factoryinstalled IECEx certified cable gland, minimum IP66/67, factory-added IECEx certified blind plug, minimum IP66/67, factory installed. For Fieldbus type, blind plug is only factory-added. IECEx certified cable gland, minimum IP66/67, factory-added Notes The user must install professionally a cable gland with minimum IP66/67 that is IECEx certified according to the type of protection used. Fieldbus type: In case of using the pulse or status output, the user must install professionally a cable gland with minimum IP66/67 that is IECEx certified according to the type of protection used. Elsewise the user must close professionally this thread with the factoryadded blind plug. The user must install professionally a cable gland with minimum IP66/67 that is IECEx certified according to the type of protection used. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 13 / 70

Explosion Proof Type Manual IECEx Installation Threads for cable glands Thread MS code Position 12 ANSI 1/2" NPT 2 Thread position 1 2 Integral type Blind plug IP66/67, factoryinstalled Blind plug IP66/67, factoryinstalled Delivery state 3 4 Remote type Metal cable gland IP66/67, factoryinstalled Blind plug IP66/67, factoryinstalled IECEx certified blind plug, minimum IP66/67, factory installed. For Fieldbus type, blind plug is only factory-added. 5 Notes The user must install professionally a cable gland with minimum IP66/67 that is IECEx certified according to the type of protection used. Fieldbus type: In case of using the pulse or status output, the user must install professionally a cable gland with minimum IP66/67 that is IECEx certified according to the type of protection used. Elsewise the user must close professionally this thread with the factoryadded blind plug. The user must install professionally a cable gland with minimum IP66/67 that is IECEx certified according to the type of protection used. The cable gland on the sensor is factory-installed. At a minimum, the allowable cable gland temperature must include the range from -50 +100 C for option L and the range -50 +80 C for option Y. 14 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Flameproof transmitter threads Explosion Proof Type Manual IECEx Installation 4.3 Flameproof transmitter threads Ex-certified models are equipped with an flameproof transmitter housing. 1 3 2 2 2 Fig. 2: Flameproof transmitter threads 1 Thread for display cover 2 Threads for cable glands or blind plugs 3 Thread for back cover Tab. 1: Technical data of flameproof threads Thread Display cover 2 Back cover 2 Cable glands ISO M20 1.5 ANSI 1/2" NPT Lead in mm Tolerance field Threads in engagement in mm 6g/6H 7 14 1.5 6H 10 15 1.814 acc. to ANSI B 1.20.1 Minimum screw-in depth in mm 6 13.605 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 15 / 70

Explosion Proof Type Manual IECEx Wiring General rules 5 Wiring 5.1 General rules DANGER Insufficient connection to the potential equalization system Life-threatening injuries from electric shock or ignition of explosive atmospheres Connect remote-type sensor via the grounding terminal outside of the housing to the potential equalization system, see Grounding connections and intrinsically safe circuits [} 17]. Connect transmitter to the potential equalization system via the grounding terminal outside of the housing, see Grounding connections and intrinsically safe circuits [} 17]. Connect grounding cable of power supply cable to the grounding screw in the terminal box, see Grounding connections and intrinsically safe circuits [} 17]. The relevant national standards must be considered for the electrical installation. Rotamass must be integrated into the potential equalization system of the hazardous area. The potential equalization must be ensured alongside the intrinsically safe circuit. The power supply must be established with a voltage 250 V at the terminals L/+ and N/-. The grounding screw in the terminal box must be mechanically firmly connected with the threaded hole. If the type of protection Ex eb is used, cable cross sections of 0.8 to 2.5 mm 2 must be used for the cables of the power supply and the cables of the inputs/outputs. The insulation of the cores must be stripped off 5 to 6 mm. The cable connections for the inputs/outputs must be established according to the connection tables. In the process, it must be ensured that the connection type matches the corresponding position of the MS code on the nameplate. The maximum input parameters of the intrinsically safe outputs must not be exceeded. 16 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

COM TP3 TP2 TP1 S2 - S2 + S1 - S1 + Grounding connections and intrinsically safe circuits Explosion Proof Type Manual IECEx Wiring 5.2 Grounding connections and intrinsically safe circuits 1 2 3 Fig. 3: Grounding connections on transmitter and sensor 1 Grounding screw in terminal box for grounding conductor 2 Grounding terminal on transmitter for potential equalization 3 Grounding terminal on sensor for potential equalization 1 2 3 4 5 6 D - D + D + D - S1 + S1 - S2 + S2 - TP1 TP2 TP3 3 2 1 Fig. 4: Connection terminal circuits (transmitter on the left side, sensor on the right side) 1 Driver circuit 2 Sensor circuits 3 measurement circuits 4 Signal grounding 5 Transmitter 6 Sensor IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 17 / 70

Explosion Proof Type Manual IECEx Wiring Transmitter connection terminals 5.3 Transmitter connection terminals 5.3.1 Configuration for HART communication 1 2 3 8 7 6 5 4 Fig. 5: Terminal box for connection to external devices for HART and for the transmitter power supply 1 Power supply connection terminals 2 Grounding screw in terminal box 3 Grounding terminal 4 I/O1 +/- 5 I/O2 +/- 6 I/O3 +/- 7 I/O4 +/- 8 WP The applicable operating instructions must be observed for connecting the cables. The connection type is defined according to the product variant ordered. The following figure shows the relevant position of the MS code: 18 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Transmitter connection terminals Explosion Proof Type Manual IECEx Wiring MS code Position 13 JA JB JC JD JE JF JG JH JJ JK JL JM JN JP JQ JR JS Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Active Iout1 Connection terminal assignment I/O1 +/- I/O2 +/- I/O3 +/- I/O4 +/- WP Iout1 Iout1 Iout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 NAMUR P/Sout1 NAMUR P/Sout2 Sin Sout Sin Sin Sin Iout2 P/Sout2 Sin Iout2 P/Sout2 Sin Iout2 Iout2 Iout2 Iout2 Write-protect Iout2 Active Iout2 Active P/Sout2 P/Sout2 P/Sout2 Active Internal pullup resistor P/Sout2 Active Iin Active Iin Active Iin Active Iin Iin Iin P/Sout2 P/Sout2 NAMUR Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Write-protect Iout1 Iout2 Iin P/Sout1 P/Sout2 Sin Sout Active or passive current output with HART communication Active or passive current output Active or passive current input pulse or status output Active or passive pulse or status output Status input Status output IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 19 / 70

Explosion Proof Type Manual IECEx Wiring Transmitter connection terminals 5.3.2 Configuration for Fieldbus communication 1 2 3 6 5 4 Fig. 6: Terminal box for connection to external devices for Fieldbus and for the transmitter power supply 1 Power supply connection terminals 2 Grounding screw in terminal box 3 Grounding terminal 4 I/O1 +/- 5 I/O2 +/- 6 WP +/- The applicable operating instructions must be observed for connecting the cables. The connection type is defined according to the product variant ordered. The following figure shows the relevant position of the MS code: MS code Position 13 F G Connection terminal assignment I/O1 +/- I/O2 +/- I/O3 +/- I/O4 +/- WP Foundation P/Sout1 Write-protect Fieldbus P/Sout1 Profibus PA Write-protect P/Sout1 pulse or status output (not available for all F ) digit 20 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Transmitter connection terminals Explosion Proof Type Manual IECEx Wiring 5.3.3 Configuration for Modbus communication 1 2 3 10 9 8 7 6 5 4 Fig. 7: Terminal box for connection to external devices for Modbus and for the transmitter power supply 1 Power supply connection terminals 2 Grounding screw in terminal box 3 Grounding terminal 4 I/O1 +/- 5 I/O2 +/- 6 I/O3 + 7 I/O3-8 I/O4 + 9 I/O4-10 WP The applicable operating instructions must be observed for connecting the cables. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 21 / 70

Explosion Proof Type Manual IECEx Wiring Transmitter connection terminals The connection type is defined according to the product variant ordered. The following figure shows the relevant position of the MS code: MS code Position 13 M0 M2 M3 M4 M5 M6 M7 Iin Connection terminal assignment I/O1 +/- I/O2 +/- I/O3 + I/O3 - I/O4 + I/O4 - WP Active P/Sout2 P/Sout2 Active P/Sout2 Active Internal pull-up resistor Iout1 Active Iin P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 P/Sout1 Modbus C Modbus B Modbus A Writeprotect Modbus C Modbus B Modbus A Writeprotect Modbus C Modbus B Modbus A Writeprotect Modbus C Modbus B Modbus A Writeprotect Modbus C Modbus B Modbus A Writeprotect Modbus C Modbus B Modbus A Writeprotect Modbus C Modbus B Modbus A Writeprotect Iout Iin P/Sout1 P/Sout2 Active current output, no HART Active or passive current input Active or passive pulse or status output Active or passive pulse or status output 22 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Installation diagrams Explosion Proof Type Manual IECEx Wiring 5.4 Installation diagrams 5.4.1 Integral type without intrinsically safe I/O outputs 1 2 4 3 I/O1+ I/O1- I/O2+ I/O2- I/O3+ I/O3- I/O4+ I/O4-1 Hazardous area 2 Safe area 3 Rotamass 4 Power supply 5 Potential equalization system 5 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 23 / 70

Explosion Proof Type Manual IECEx Wiring Installation diagrams 5.4.2 Integral type with intrinsically safe I/O outputs 1 2 4 3 I/O1+ I/O1- I/O2+ I/O2- I/O3+ I/O3- I/O4+ I/O4-5 5 5 5 1 Hazardous area 2 Safe area 3 Rotamass 4 Power supply 5 Associated apparatus 6 Potential equalization system 6 Multi-core cable connecting separated intrinsically safe circuits I/O1, I/O2, I/O3, I/O4 shall be type A or B in accordance with IEC 60079-14. 24 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Installation diagrams Explosion Proof Type Manual IECEx Wiring 5.4.3 Integral type for Fieldbus communication (intrinsically safe) 1 2 3 4 5 3 6 I/O1+ I/O1- I/O2+ I/O2- I/O3+ I/O3- I/O4+ I/O4-5 7 1 Hazardous area 2 Safe area 3 Terminator 4 Field device 5 Associated apparatus 6 Rotamass 7 Power supply 8 Potential equalization system 8 Cable connecting intrinsically safe circuit I/O1, I/O2 shall be type A or B in accordance with IEC 60079-14. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 25 / 70

Explosion Proof Type Manual IECEx Wiring Installation diagrams 5.4.4 Remote type without intrinsically safe I/O outputs Option L 1 2 3 5 6 4 I/O1+ I/O1- I/O2+ I/O2- I/O3+ I/O3- I/O4+ I/O4-1 Hazardous area 2 Hazardous area or safe area 3 Safe area 4 Sensor 5 Transmitter 6 Power supply 7 Potential equalization system D+/D- Driver circuit S1+/ S1-, S2+/S2- Sensor circuits TP1, TP2, TP3 measurement circuits 7 Multi-core cable connecting separated intrinsically safe circuits D+/D-, S1+/S1-, S2+/S2- and TP1/TP2/TP3 shall be type A or B in accordance with IEC 60079-14. 26 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Installation diagrams Explosion Proof Type Manual IECEx Wiring Option Y 1 2 3 5 4 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 COM L N I/O1+ I/O1 I/O2+ I/O2 I/O3+ I/O3 I/O4+ I/O4 6 1 Hazardous area 2 Hazardous area or safe area 3 Safe area 4 Sensor 5 Transmitter 6 Power supply 7 Potential equalization system D+/D- Driver circuit S1+/ S1-, S2+/S2- Sensor circuits TP1, TP2, TP3 measurement circuits 7 Multi-core cable connecting separated intrinsically safe circuits D+/D-, S1+/S1-, S2+/S2- and TP1/TP2/TP3 shall be type A or B in accordance with IEC 60079-14. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 27 / 70

Explosion Proof Type Manual IECEx Wiring Installation diagrams 5.4.5 Remote type with intrinsically safe I/O outputs Option L 1 2 3 5 6 4 I/O1+ I/O1- I/O2+ I/O2- I/O3+ I/O3- I/O4+ I/O4-7 7 7 7 1 Hazardous area 2 Hazardous area or safe area 3 Safe area 4 Sensor 5 Transmitter 6 Power supply 7 Associated apparatus 8 Potential equalization system D+/D- Driver circuit S1+/ S1-, S2+/S2- Sensor circuits TP1, TP2, TP3 measurement circuits 8 Multi-core cable connecting separated intrinsically safe circuits I/O1, I/O2, I/O3, I/O4 shall be type A or B in accordance with IEC 60079-14. Multi-core cable connecting separated intrinsically safe circuits D+/D-, S1+/S1-, S2+/S2- and TP1/TP2/TP3 shall be type A or B in accordance with IEC 60079-14. 28 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Installation diagrams Option Y Explosion Proof Type Manual IECEx 1 2 3 Wiring 5 4 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 COM L N I/O1+ I/O1 I/O2+ I/O2 I/O3+ I/O3 I/O4+ I/O4 6 7 7 7 7 1 Hazardous area 2 Hazardous area or safe area 3 Safe area 4 Sensor 5 Transmitter 6 Power supply 7 Associated apparatus 8 Potential equalization system D+/D- Driver circuit S1+/ S1-, S2+/S2- Sensor circuits TP1, TP2, TP3 measurement circuits 8 Multi-core cable connecting separated intrinsically safe circuits I/O1, I/O2, I/O3, I/O4 shall be type A or B in accordance with IEC 60079-14. Multi-core cable connecting separated intrinsically safe circuits D+/D-, S1+/S1-, S2+/S2- and TP1/TP2/TP3 shall be type A or B in accordance with IEC 60079-14. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 29 / 70

Explosion Proof Type Manual IECEx Wiring Installation diagrams 5.4.6 Remote type for Fieldbus communication (intrinsically safe) Option L 1 2 3 5 4 3 7 6 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 COM I/O1+ I/O1 I/O2+ I/O2 I/O3+ I/O3 I/O4+ I/O4 8 5 9 1 Hazardous area 2 Safe area 3 Terminator 4 Field device 5 Associated apparatus 6 Sensor 7 Transmitter 8 Power supply 9 Potential equalization system D+/D- Driver circuit S1+/ S1-, S2+/S2- Sensor circuits TP1, TP2, TP3 measurement circuits Cable connecting intrinsically safe circuit I/O1, I/O2 shall be type A or B in accordance with IEC 60079-14. Multi-core cable connecting separated intrinsically safe circuits D+/D-, S1+/S1-, S2+/S2- and TP1/TP2/TP3 shall be type A or B in accordance with IEC 60079-14. 30 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Installation diagrams Explosion Proof Type Manual IECEx Wiring Option Y 1 2 3 5 4 3 7 6 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 D+ D S1+ S1 S2+ S2 TP1 TP2 TP3 COM I/O1+ I/O1 I/O2+ I/O2 I/O3+ I/O3 I/O4+ I/O4 L N 8 5 1 Hazardous area 2 Safe area 3 Terminator 4 Field device 5 Associated apparatus 6 Sensor 7 Transmitter 8 Power supply 9 Potential equalization system D+/D- Driver circuit S1+/ S1-, S2+/S2- Sensor circuits TP1, TP2, TP3 measurement circuits 9 Cable connecting intrinsically safe circuit I/O1, I/O2 shall be type A or B in accordance with IEC 60079-14. Multi-core cable connecting separated intrinsically safe circuits D+/D-, S1+/S1-, S2+/S2- and TP1/TP2/TP3 shall be type A or B in accordance with IEC 60079-14. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 31 / 70

Explosion Proof Type Manual IECEx Operation, maintenance and repair General rules 6 Operation, maintenance and repair 6.1 General rules DANGER Life-threatening injuries from electric shock Switch off power supply. Secure power supply against inadvertent switch-on. Check that power supply is free of voltage. DANGER Life-threatening injuries from ignition of explosive atmospheres Wait 20 minutes before opening the housing until the capacitors have discharged and components have cooled off. Avoid electrostatically charging the device, e.g. by rubbing it with dry cloths. Modifying the coriolis mass flow meter as well as using unauthorized parts is prohibited and will void the certification. The locking screws of the covers may be loosened and tightened only with an Allen wrench. After closing and before commissioning, it must be checked whether the locking screws are tightened and the covers are closed. 32 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Replacing the sensor Explosion Proof Type Manual IECEx Operation, maintenance and repair 6.2 Replacing the sensor If a defective Rotamass TI sensor must be replaced, contact the Yokogawa service. Generally the MS code of a spare sensor can be different from the installed design. In this case the MS code of the sensor must be selected and checked. Integral type MS code position Meaning Check criteria between MS-Codes of installed design and spare sensor 1 Transmitter without hazardous area restriction 2 Sensor 3 Meter size if changed see 1 could differ with restriction see 2, value 3 is excluded 4 Material wetted parts without hazardous area restriction 5 Process connection size without hazardous area restriction 6 Process connection size without hazardous area restriction 7 Sensor housing material without hazardous area restriction 8 Medium temperature range if changed see 1 9 Mass flow and density accuracy without hazardous area restriction 10 Design and housing restriction to numeric values (0,1,2, ) 11 Ex approval must be identical 12 Cable entries without hazardous area restriction 13 Communication type and I/O without hazardous area restriction, except: intrinsic safe outputs JP JU, F ( odd), G1 must be identical 14 Display without hazardous area restriction 15 Options without hazardous area restriction, except option EPT must be identical 1 The Ex codes must be compared. If they are different then 2 is applicable. In case of no Ex-Code take the temperature specification from applicable Explosion Proof certificate or the applicable User s Manual for Explosion Proof Type. 2 The temperature specification of the spare sensor has to be evaluated according to MS- Code and Ex code Ex code [} 48]. In case of no Ex-Code take the temperature specification from applicable Explosion Proof certificate or the applicable User s Manual for Explosion Proof Type. Compare the temperature specification with the requirements of hazardous area and perform assessment. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 33 / 70

Explosion Proof Type Manual IECEx Operation, maintenance and repair Replacing the sensor Remote type MS code position Meaning Check criteria between MS-Codes of installed design and spare sensor 1 Transmitter without hazardous area restriction 2 Sensor 3 Meter size if changed see 1 could differ with restriction see 2, value 3 is excluded 4 Material wetted parts without hazardous area restriction 5 Process connection size without hazardous area restriction 6 Process connection size without hazardous area restriction 7 Sensor housing material without hazardous area restriction 8 Medium temperature range if changed see 1 9 Mass flow and density accuracy without hazardous area restriction 10 Design and housing 11 Ex approval must be identical restriction to alphabetic values (A,B, ); type B, D, F, K must not be changed to type A, C, E, J. 12 Cable entries without hazardous area restriction 13 Communication type and I/O without hazardous area restriction 14 Display without hazardous area restriction 15 Options without hazardous area restriction, except: option EPT, Y must be identical and see 1. If option T changes see 1. 1 The Ex codes must be compared. If they are different then 2 is applicable. In case of no Ex-Code take the temperature specification from applicable Explosion Proof certificate or the applicable User s Manual for Explosion Proof Type. 2 The temperature specification of the spare sensor has to be evaluated according to MS- Code and Ex code Ex code [} 48]. In case of no Ex-Code take the temperature specification from applicable Explosion Proof certificate or the applicable User s Manual for Explosion Proof Type. Compare the temperature specification with the requirements of hazardous area and perform assessment. 34 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Replacing the transmitter Explosion Proof Type Manual IECEx Operation, maintenance and repair 6.3 Replacing the transmitter If a defective Rotamass TI transmitter must be replaced, contact the Yokogawa service. Generally the MS code of a spare transmitter can be different from the installed design. In this case the MS code of the transmitter must be selected and checked. Integral type MS code position Meaning Check criteria between MS-Codes of installed design and spare transmitter 1 Transmitter without hazardous area restriction 2 Sensor value 3 is excluded 3 Meter size without hazardous area restriction 4 Material wetted parts without hazardous area restriction 5 Process connection size without hazardous area restriction 6 Process connection size without hazardous area restriction 7 Sensor housing material without hazardous area restriction 8 Medium temperature range without hazardous area restriction 9 Mass flow and density accuracy without hazardous area restriction 10 Design and housing restriction to numeric values (0,1,2, ) 11 Ex approval must be identical 12 Cable entries without hazardous area restriction 13 Communication type and I/O without hazardous area restriction, except: intrinsic safe outputs: JP JU; F ( odd), G1 must be identical 14 Display without hazardous area restriction 15 Options without hazardous area restriction, except: option EPT must be identical The transmitter replacement for an integral-type Rotamass 3 series instrument is not possible. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 35 / 70

Explosion Proof Type Manual IECEx Operation, maintenance and repair Replacing the transmitter Remote type MS code position Meaning Check criteria between MS-Codes of installed design and spare transmitter 1 Transmitter without hazardous area restriction 2 Sensor without hazardous area restriction 3 Meter size without hazardous area restriction 4 Material wetted parts without hazardous area restriction 5 Process connection size without hazardous area restriction 6 Process connection size without hazardous area restriction 7 Sensor housing material without hazardous area restriction 8 Medium temperature range without hazardous area restriction 9 Mass flow and density accuracy without hazardous area restriction 10 Design and housing restriction to alphabetic (A,B, ) 11 Ex approval without hazardous area restriction 12 Cable entries without hazardous area restriction 13 Communication type and I/O without hazardous area restriction 14 Display without hazardous area restriction 15 Options without hazardous area restriction, except: option EPT, Y must be identical. Remote transmitters as replacement for Rotamass 3 transmitters must be identified by the value 3 in the MS code position 2. 36 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Explosion Proof Type Manual IECEx Approvals and standards 7 Approvals and standards IECEx approval IECEx DEK 15.0016X Applied standards IEC 60079-0:2011 IEC 60079-1:2014 IEC 60079-7:2015 IEC 60079-11:2011 IEC 60079-31:2013 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 37 / 70

Explosion Proof Type Manual IECEx Technical data 8 Technical data This chapter features the ex-relevant technical data. Aside from the maximum surface temperature, the technical data of the integral type as well as the remote type transmitters are identical, regardless of product family. For the remote-type sensor the technical data are different, depending on the product family. Integral type [} 39] Remote type Nano [} 41] Supreme, Intense and Giga sensor [} 42] Prime and Hygienic sensor [} 43] CNG sensor [} 41], [} 42] LPG sensor [} 41], [} 42] Transmitter [} 44] Connecting cable [} 46] Connection to Rotamass 3 sensor [} 47] 38 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Integral type Explosion Proof Type Manual IECEx Technical data 8.1 Integral type The Ex marking is determined via the Ex approval product properties as well as inputs and outputs. Ex marking Ex approval MS code Position 11 IECEx approval for explosion group IIC and IIIC IECEx approval for explosion group IIB and IIIC 1 : even digit 2 : odd digit SF21 SF22 Inputs and outputs Nonintrinsically safe Intrinsically safe Nonintrinsically safe Intrinsically safe MS code Position 13 JA, JB, JC, JD, JE, JF, JG, JH, JJ, JK, JL, JM, JN M0, M2, M3, M4, M5, M6, M7 F 1 G0 JP, JQ, JR, JS F 2 G1 JA, JB, JC, JD, JE, JF, JG, JH, JJ, JK, JL, JM, JN M0, M2, M3, M4, M5, M6, M7 F 1 G0 JP, JQ, JR, JS F 2 G1 Ex marking Ex db ib IIC T6...T1 Gb or Ex db eb ib IIC T6...T1 Gb Ex ib tb IIIC T150 C Db Ex db ib [ia Ga] IIC T6...T1 Gb or Ex db eb ib [ia Ga] IIC T6...T1 Gb Ex ib tb [ia Da] IIIC T150 C Db Ex db ib IIB T6...T1 Gb or Ex db eb ib IIB T6...T1 Gb Ex ib tb IIIC T150 C Db Ex db ib [ia IIC Ga] IIB T6...T1 Gb or Ex db eb ib [ia IIC Ga] IIB T6...T1 Gb Ex ib tb [ia Da] IIIC T150 C Db Allowed temperature ranges Standard temperature range Medium temperature range -50 +150 C Maximum surface temperature +150 C Ambient temperature range -40 +60 C IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 39 / 70

Explosion Proof Type Manual IECEx Technical data Integral type Technical data Electrical data Operating voltage V AC Operating voltage V DC Maximum output Overvoltage category Maximum r.m.s. a.c. or d.c. voltage non-intrinsically safe circuits U m 20.4 28.8 V AC or 80 250 V AC 20.4 28.8 V DC or 90 130 V DC 10 W II 250 V Maximum input values for intrinsically safe current and pulse outputs (HART communication) Current output Voltage U i 30 V 30 V Pulse output Current I i 300 ma 300 ma Power P i 1.25 W 1.25 W Inductance L i 12 µh 12 µh Electrical capacitance C i 4.84 nf 14.6 nf The dielectric strength of at least 500 V a.c. r.m.s. between the intrinsically safe circuits and the enclosure is limited only by the overvoltage protection. Maximum input values for intrinsically safe Fieldbus and pulse output (Fieldbus communication) Fieldbus Voltage U i 30 V 30 V Pulse output Current I i 380 ma 300 ma Power P i 5.32 W 1.25 W Inductance L i 10 µh 12 µh Electrical capacitance C i 5 nf 14.6 nf FISCO field device The dielectric strength of at least 500 V a.c. r.m.s. between the intrinsically safe circuits and the enclosure is limited only by the overvoltage protection. Ambient conditions IP code of housing IP66/IP67 Relative humidity range 0 95 % Allowed pollution degree according to IEC 61010-1 4 (in operation) 40 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Remote type Explosion Proof Type Manual IECEx Technical data 8.2 Remote type 8.2.1 Nano, CNG, LPG sensor The Ex marking is determined via the Ex approval product property. The following figure shows the relevant position of the MS code: Ex marking Ex approval MS code Position 11 IECEx approval for explosion group IIC and IIIC IECEx approval for explosion group IIB and IIIC SF21 SF22 Ex marking Ex ib IIC T6...T1 Gb Ex ib IIIC T C 1 Db Ex ib IIB T6...T1 Gb Ex ib IIIC T C 1 Db 1 Maximum surface temperature according to the tables "Allowed temperatures" Allowed temperature ranges The allowed temperature ranges specified below are based on the technical performance parameters of Rotamass. In addition, temperature classes are relevant and must be taken into account for Ex applications. In case of CNG and LPG sensors with "Meter size" smaller than 34 these ranges are applicable. Standard temperature range Medium temperature range -50 +150 C Maximum surface temperature +150 C Ambient temperature range, with option L -50 +80 C Ambient temperature range, with option Y -35 +80 C Heat tracing temperature range 0 +150 C Mid-temperature range Medium temperature range -50 +260 C Medium temperature range, with option Insulation T -50 +260 C Ambient temperature range, with option L -50 +80 C Ambient temperature range, with option Y -35 +80 C Maximum surface temperature +260 C Maximum surface temperature, with option Insulation T +260 C Heat tracing temperature range 0 +220 C Ambient conditions IP code of housing IP66/IP67 Relative humidity range 0 95 % Allowed pollution degree according to IEC 61010-1 4 (in operation) IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 41 / 70

Explosion Proof Type Manual IECEx Technical data Remote type 8.2.2 Supreme, CNG, LPG, Intense and Giga sensor The Ex marking is determined via the Ex approval product property. The following figure shows the relevant position of the MS code: Ex marking Ex approval MS code Position 11 IECEx approval for explosion group IIC and IIIC IECEx approval for explosion group IIB and IIIC SF21 SF22 Ex marking Ex ib IIC T6...T1 Gb Ex ib IIIC T C 1 Db Ex ib IIB T6...T1 Gb Ex ib IIIC T C 1 Db 1 Maximum surface temperature according to the tables "Allowed temperatures" Allowed temperature ranges The allowed temperature ranges specified below are based on the technical performance parameters of Rotamass. For Ex applications, the Ex code and the classes are also relevant and must be taken into account. In case of CNG and LPG sensors with "Meter size" 34 these ranges are applicable. Standard temperature range Medium temperature range -50 +150 C Maximum surface temperature +150 C Ambient temperature range, with option L -50 +80 C Ambient temperature range, with option Y -35 +80 C Heat tracing temperature range 0 +150 C Low-temperature range Medium temperature -200 +150 C Maximum surface temperature +150 C Heat tracing temperature 0 +150 C Ambient temperature range, with option L -50 +80 C Ambient temperature range, with option Y -35 +80 C Mid-temperature range Medium temperature -50 +220 C Maximum surface temperature +220 C Heat tracing temperature 0 +220 C Ambient temperature range, with option L -50 +80 C Ambient temperature range, with option Y -35 +80 C High-temperature range Medium temperature 0 +350 C Maximum surface temperature +350 C Heat tracing temperature 0 +350 C Ambient temperature range, with option L -50 +80 C Ambient temperature range, with option Y -35 +80 C Technical data Ambient conditions IP code of housing IP66/IP67 Relative humidity range 0 95 % Allowed pollution degree according to IEC 61010-1 4 (in operation) 42 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Remote type Explosion Proof Type Manual IECEx Technical data 8.2.3 Prime and Hygienic sensor The Ex marking is determined via the Ex approval product property. The following figure shows the relevant position of the MS code: Ex marking Ex approval MS code Position 11 IECEx approval for explosion group IIC and IIIC IECEx approval for explosion group IIB and IIIC SF21 SF22 Ex marking Ex ib IIC T6...T1 Gb Ex ib IIIC T C 1 Db Ex ib IIB T6...T1 Gb Ex ib IIIC T C 1 Db 1 Maximum surface temperature according to the tables "Allowed temperatures" Allowed temperature ranges The allowed temperature ranges specified below are based on the technical performance parameters of Rotamass. For Ex applications, the Ex code and the classes are also relevant and must be taken into account. Standard temperature range Medium temperature range -50 +200 C Maximum surface temperature +200 C Ambient temperature range, with option L -50 +80 C Ambient temperature range, with option Y -35 +80 C Technical data Ambient conditions IP code of housing IP66/IP67 Relative humidity range 0 95 % Allowed pollution degree according to IEC 61010-1 4 (in operation) IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 43 / 70

Explosion Proof Type Manual IECEx Technical data Remote type 8.2.4 Transmitter The Ex marking is determined via the Ex approval product properties as well as inputs and outputs. Ex marking Tab. 2: Ex marking depending on the MS code for transmitters of remote types of all product families Ex approval IECEx approval for explosion group IIC and IIIC IECEx approval for explosion group IIB and IIIC 1 : even digit 2 : odd digit MS code Position 11 SF21 SF22 Inputs and outputs Nonintrinsically safe Intrinsically safe Nonintrinsically safe Intrinsically safe MS code Position 13 JA, JB, JC, JD, JE, JF, JG, JH, JJ, JK, JL, JM, JN M0, M2, M3, M4, M5, M6, M7 F 1 G0 JP, JQ, JR, JS F 2 G1 JA, JB, JC, JD, JE, JF, JG, JH, JJ, JK, JL, JM, JN M0, M2, M3, M4, M5, M6, M7 F 1 G0 JP, JQ, JR, JS F 2 G1 Ex marking Ex db [ia Ga] IIC T6 Gb or Ex db eb [ia Ga] IIC T6 Gb Ex tb [ia Da] IIIC T75 C Db Ex db [ia Ga] IIC T6 Gb or Ex db eb [ia Ga] IIC T6 Gb Ex tb [ia Da] IIIC T75 C Db Ex db [ia Ga] IIB T6 Gb or Ex db eb [ia Ga] IIB T6 Gb Ex tb [ia Da] IIIC T75 C Db Ex db [ia Ga] [ia IIC Ga] IIB T6 Gb or Ex db eb [ia Ga] [ia IIC Ga] IIB T6 Gb Ex tb [ia Da] IIIC T75 C Db 44 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Remote type Explosion Proof Type Manual IECEx Technical data Technical data Allowed temperatures Ambient temperature range -40 +60 C Maximum surface temperature +75 C Electrical data Operating voltage V AC 20.4 28.8 V AC or 80 250 V AC Operating voltage V DC 20.4 28.8 V DC or 90 130 V DC Maximum output 10 W Overvoltage category Maximum r.m.s. a.c. or d.c. voltage non-intrinsically safe circuits U m II 250 V Maximum input values for intrinsically safe current and pulse outputs (HART communication) Current output Voltage U i 30 V 30 V Pulse output Current I i 300 ma 300 ma Power P i 1.25 W 1.25 W Inductance L i 12 µh 12 µh Electrical capacitance C i 4.84 nf 14.6 nf The dielectric strength of at least 500 V a.c. r.m.s. between the intrinsically safe circuits and the enclosure is limited only by the overvoltage protection. Maximum input values for intrinsically safe Fieldbus and pulse output (Fieldbus communication) Fieldbus Voltage U i 30 V 30 V Pulse output Current I i 380 ma 300 ma Power P i 5.32 W 1.25 W Inductance L i 10 µh 12 µh Electrical capacitance C i 5 nf 14.6 nf FISCO field device The dielectric strength of at least 500 V a.c. r.m.s. between the intrinsically safe circuits and the enclosure is limited only by the overvoltage protection. Ambient conditions IP code of housing IP66/IP67 Relative humidity range 0 95 % Allowed pollution degree according to IEC 61010-1 4 (in operation) IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 45 / 70

Explosion Proof Type Manual IECEx Technical data Remote type 8.2.5 Connecting cable To connect the sensor with the transmitter, the following specifications must be adhered to for Ex applications: Complete cable range, with option L -50 +105 C range, with option Y Connection terminals/cable section -35 +80 C Maximum inductance Maximum capacitance D+/D-, S1+/ S1-, S2+/S2- < 0.03 mh < 90 nf TP1, TP2, TP3 < 158 mh < 11 µf Calculation of maximum allowed cable length for option L The supplied connecting cable has the following line constants: Line type Coaxial Connection terminals D+/D-, S1+/ S1-, S2+/S2- Core/core Capacitance in nf/km Core/shield Inductance in mh/km 120 132 0.175 AWG20 TP1, TP2, TP3 145 290 0.7 The resulting maximum allowed cable length is: Connection terminals D+/D-, S1+/ S1-, S2+/S2- D+/D-, S1+/ S1-, S2+/S2- Limitation Calculation Length limitation Inductance 0.03 mh / (0.175 mh/km) = 171 m Capacitance 90 nf / (132 nf/km) = 682 m TP1, TP2, TP3 Inductance 158 mh / (0.7 mh/km) = 226 km TP1, TP2, TP3 Capacitance 11 µf / (290 nf/km) = 38 km Maximum allowed cable length = 171 m See also installation diagrams, Remote type with intrinsically safe I/O outputs [} 28]. Calculation of maximum allowed cable length for option Y The supplied marine cable has the following line constants: Connection terminals Capacitance in nf/km Inductance in mh/km D+/D-, S1+/ S1-, S2+/S2-,TP1, TP2, TP3 81 0.315 Inductance and capacitance at terminals D+/D-, S1+/S1-, S2+/S2- are limiting. Limitation Calculation Length limitation Inductance 0.03 mh / (0.315 mh/km) = 95 m Capacitance 90 nf / (81 nf/km) = 1.1 km Maximum allowed cable length = 95 m 46 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16

Remote type Explosion Proof Type Manual IECEx Technical data 8.2.6 Connection to Rotamass 3 sensor If a Rotamass Essential or Ultimate transmitter was configured for use at a remote type Rotamass 3 sensor via the MS code, the maximum input and output values of the Rotamass 3 sensor must be observed; see the corresponding operating instructions. Tab. 3: Maximum output values, connection terminals Rotamass TI transmitter to Rotamass 3 sensor Connection terminals Voltage U o in V Current I o in ma Power P o in mw Inductance L o in mh Electrical capacitance C o in µf IIC IIB IIC IIB IIC IIB IIC IIB IIC IIB D+/D- 14.28 47 134.4 168 480 16 7.8 0.68 4.28 S1+/S1- or S2+/ S2-7.14 36.1 64.4 27 13.5 TP1, TP2, TP3 7.14 10.7 19.1 310 13.5 The medium temperature ranges of the Rotamass 3 sensor must be observed. The corresponding documentation of the Rotamass 3 is applicable to the respective sensor. The medium temperature range specified in this document applies to the transmitter, see Transmitter [} 44]. IM 01U10X02-00EN-R, 3rd edition, 2017-11-16 47 / 70

Explosion Proof Type Manual IECEx Technical data Ex code 8.3 Ex code The Ex code, in combination with the MS code positions 2 and 10, allows determining the maximum medium and ambient temperatures for every temperature class according to the Ex certificate. In each case, it is located on the additional nameplate of the sensor, except for Rotamass Nano and all high-temperature versions. No Ex code is available for these devices so that the medium temperature ranges must be taken directly from the chapter specification by temperature classes [} 53]. IECEx DEK 15.0016X Ex ib IIB T6...T1 Gb Ex ib IIIC T200 o C Db 3.68.67.65.63.39 SEE CERTIFICATE FOR DATA ENCLOSURE IP66/67 Fig. 8: Additional nameplate with Ex code Ex code design The Ex code is a 6-digit key with the following design: 3. 68. 67. 65. 63. 39 a. p6. p5. p4. p3. p2 a p6 p5 p4 p3 p2 Ambient temperature column number Line number of maximum process temperature for temperature class T6 Line number of maximum process temperature for temperature class T5 Line number of maximum process temperature for temperature class T4 Line number of maximum process temperature for temperature class T3 Line number of maximum process temperature for temperature classes T2 and T1 8.3.1 Determining the maximum temperatures based on the Ex code The specific example below is intended to explain how to determine the maximum medium and ambient temperatures based on the Ex code and the MS code. The complete tables of the medium temperature range are listed in the "Annex 1" of the Ex certificate. Option (L or Y ) determines table a or b for remote variants. This example presents only excerpts thereof. The following steps are performed to determine the maximum temperatures: Determining the maximum process temperature T pro,max based on the Ex code, positions p6...p2 Determining the maximum ambient temperature T amb pre based on the following criteria: MS code position 2 and 10 Ex code, position a Determined maximum process temperatures T pro,max 48 / 70 IM 01U10X02-00EN-R, 3rd edition, 2017-11-16