Cast resin transformers HARMONY TM

Similar documents
DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

SPECIFICATION GUIDE. ABB Power Technology, S.A. Zaragoza, SPAIN. ABB Power Technologies Distribution Transformers

ELECTRICAL NETWORKS SPECIFICATION TECHNICAL SPECIFICATION FOR A 230V/110V AND 400V/110V TRANSFORMER

TMC Transformers TMC

Title Substation Auxiliary Transformer from Rectifier Transformer Secondary. Reference Number PDS 01 (RIC Standard: EP SP)

MESP TECHNICAL SPECIFICATION FOR AN AUXILIARY OR ESSENTIAL SERVICES AND AUXILIARY TRANSFORMER FOR USE IN A RAILWAY SUBSTATION

K Factor Power Transformers

MESP TECHNICAL SPECIFICATION FOR AN ESSENTIAL SERVICES SUPPLY STEP UP TRANSFORMER

(

Basic Principles and Operation of Transformer

SPECIFICATION FOR STEP UP TRANSFORMER 0.415/11Kv and (630KVA & 1000KVA)

DATA SHEET FOR LIGHTING TRANSFORMER APPD. BY VDV PROJECT NO

.1 Provide dry type cast-resin 11kV/0.420kV transformers in accordance with the Contract Documents.

Arild Furnes,ATPA OGP/Petrobras workshop, Dry type transformers-ideal for FPSO - Transformers for electrical and drive systems

Brown University Revised 2/1/2006 Facilities Design & Construction Requirements SECTION 16461C - DRY TYPE TRANSFORMERS

save energy, it is precious SYNERGY transformers Mfg. of all types of Distribution / Power & Furnace Transformers

Convincing technology creates compact performance

ELETTROMECCANICA. Since english OIL IMMERSED DISTRIBUTION TRANSFORMERS

PURCHASE SPECIFICATIONS 500KVA DRY TYPE TRANSFORMER FOR OIL RIG APPLICATIONS

Trasfor 3E Series. Reliable Answers to Your Questions. Made in Switzerland

OIL-IMMERSED ARC-SUPPRESSION COILS

CAST RESIN DRY TRANSFORMER

INSTALLATION, OPERATION AND MAINTENANCE GUIDE

COMPANY PROFILE... 1 QUALITY CERTIFICATES... 2 APPLICATIONS... 3

siemens.com/transformers Convincing technology creates compact performance The GEAFOL Basic: the optimum foundation for power distribution

MGM Transformer. Vacuum Pressure Impregnated (VPI) Dry-Type Substation Transformer Specification Guide

CONSULTANT PROCEDURES & DESIGN GUIDELINES Liquid-Filled Utility Transformers UNIVERSITY OF MISSOURI

UNIVERSITY OF MISSOURI Liquid-Filled Utility Transformers 2016 Q1

Distribution transformers Part 2 Ground mounted transformers not closecoupled

SGMF(T) series. Onsite Mobile AC High Voltage Test System. Applications:

Neutral Earthing. For permanent or temporary neutral earthing in HV systems

UBC Technical Guidelines Section Edition Medium-Voltage Transformers Page 1 of 5

MESP TECHNICAL SPECIFICATION FOR A 1500V DC RECTIFIER TRANSFORMER

TECHNICAL DESCRIPTION TD-77A/3 170 KV COMPACT GAS INSULATED INTEGRATED SUBSTATION MODULES

SINGLE PHASE BUCK & BOOST TRANSFORMERS INSTRUCTION MANUAL

TECHNICAL SPECIFICATION FOR POWER TRANSFORMER

Your safety first! This is the reason why our manual begins with the following guidelines:

About us. Vision. To lead our field in innovation, quality and customer service.

75 kva Isolation Transformer V Delta Primary Voltage - 480Y/277 Secondary Voltage - NEMA 3R

36kV VOLTAGE TRANSFORMERS (OUTDOOR TYPE)

Introduction. Centrado leading-edge transformer. Introduction

Dry-type Transformer. High Reliability Maintenance-free Environmentally Friendly

Series P. Applications

Test Report CESI A6/ Approved Page 1. MF Trasformatori s.r.l. - Calcinato (BS) Italy

Climatic, Environmental and Fire Behaviour (C2 E2 F1) Test of Cast Resin Transformer

SECTION TRANSFORMERS

Onsite Mobile AC High Voltage Test System

Electrical Description

2.7. IT system floor-standing distribution cabinet Series -IPS-F/EDS

Reference Number PPS 05 - (RIC Standard: EP SP)

SHORE TO SHIP FREQUENCY

10/2 Product overview. 10/3 4AC3 0, 4AC3 1 bell transformers. 10/5 4AC AC3 6 transformers for permanent loads. 10/8 4AC2 4 power supply units

TECHNICAL INFORMATION

High Performance Current Transducer IT 200-S ULTRASTAB = A. ε L

The GEAFOL Neo: the optimum foundation for power distribution siemens.com/transformers

Cast Resin Transformers

Schedule of Accreditation issued by United Kingdom Accreditation Service 2 Pine Trees, Chertsey Lane, Staines-upon-Thames, TW18 3HR, UK

Flexible AC current probes

nical catalogue Tech

SHARDA Make Harmonics Filter

Current clamps for AC current

GE Ventilated Dry-Type Transformers. Secondary Substation Transformers - 5 and 15kV Class

MANUFACTURING GUIDELINES FOR PLC (LEVEL-1 AUTOMATION)

KNOW MORE ABOUT THE TRANSFORMERS. Glossary Transformers

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

Ritz Instrument Transformers GmbH. Welcome

Tesar s.r.l. Installation and maintenance manual. Installation, use and maintenance. Manual. Page :1\20

PFCC-1000 series. Powerful Flexibility Durability - Quality. Medium Voltage Metal Enclose 5,15,25,35kV Power Factor Correction & Harmonic Filter

500 kva Isolation Transformer - 480V Delta Primary - 400Y/231 Wye Secondary - NEMA 3R

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

VI 3 - i TABLE OF CONTENTS

MODULOBLOC TRANSFORMERS

STAR ELECTRIC COMPANY

For ultra-high precision measurement of current: DC, AC, pulsed..., with galvanic separation between primary and secondary. Applications.

ISOLATING TRANSFORMERS FOR TLC PLANTS

Voltage Transformers type UMZ User s Manual, Operation and Maintenance

SRA 2250/6 RESISTOR ARS-01 RESISTOR AUTOMATICS

PRESENTATION ON IS 1180 (Part 1): 2014 DISTRIBUTION TRANSFORMERS SHYAM KUMAR SCIENTIST B ELECTROTECHNICAL BUREAU OF INDIAN STANDARDS

and cured to reduce hot spots and seal out moisture. The assembly shall be installed on vibration-absorbing pads.

SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

DISTRIBUTION TRANSFORMERS

MODEL INFORMATION. Model AWRMS TM 200. Automated Winding Resistance Measurement System

Compliant to DOE 10, CFR Part 431 (effective as of January 1 st, 2016)

POWER TRANSFORMERS CATALOGUE

General Electricity Company of Libya

75 kva Isolation Transformer - 480V Delta Primary - 208V Delta Secondary - NEMA 3R

STS Fully automatic. Large graphic display. Primary injection testing capabilities: up to 3000 A, with the optional module BUX 3000

C20.en. Power contactors for AC and DC CT1115 and CT1130. Connect - Contact - Control

SB 50 Connectors - up to 120 amps

Company Directive ENGINEERING SPECIFICATION EE SPEC: 5/5. Relating to 11kV Distribution Transformers

The NOVA Recloser shall be designed and tested in accordance with the following standards as applicable:

COMBINED METERING TRANSFORMERS (OUT DOOR TYPE) FOR 11kV & 33kV SYSTEMS

OUTDOOR VOLTAGE TRANSFORMERS (Indoor units available) Description:

Transformers Contents Page

5 kva Isolation Transformer - 115V Primary Voltage - 230V Secondary Voltage - Single Phase - NEMA 3R

Title: Southern States Type SLS Smart Sectionalizer Solid Dielectric Three Phase Sectionalizer. Product Specification Guide TABLE OF CONTENTS

51-SDMS-04 SPECIFICATIONS FOR. DISTRIBUTION TRANSFORMERS UP TO 36 kv WITH ALUMINUM WINDINGS FOR DUAL SECONDARY 400/230 V AND 230/133 V

Efacec work every day to anticipate solutions for a sustainable world in the new energy era.

T/3000 T/3000. Substation Maintenance and Commissioning Test Equipment

Technical Specifications

Transcription:

Cast resin transformers HARMONY TM

HARMONY TM the optimum solution for higher performance At a time when we are all seeking to preserve our way of life, the production of equipment whilst ensuring safety and protecting the environment is our prime objective. HARMONY TM series, with its 60 oblique winding and its eclusive casting system, provides a real answer to the problems set with regard to safety and protection of personnel, equipment and the environment. Ecellent classification according to standard HD 464 S (tests performed at CESI laboratory in Italy). - F Fire behaviour. Harmony is non-flammable and self-etinguishing - C2 Insensitive to thermal shocks. Harmony withstands to loads and overloads changes. Dielectric tests and measurement of partial discharges 0 pc. - E2 Insensitive to corrosive environments. Harmony resists to polluted environments and humidity. Well adaptation to disturbed electrical environments. Recycle of components. No release of toic or corrosive products and opaque smokes in the event of pyrolysis. The Harmony eclusive casting system has obtained an ecellent classification according to standard NF F 6-0 (tests performed at National Test Laboratory in Trappes) confirming the non-toicity of decomposition products as well as the low quantities of opaque smoke produced in case of fire. General specifications Three-phase transformers 50 Hz, class F dry type cast resin, cooled naturally by air AN, for continuous indoor service (insulation outdoors, cooling AF, available on request). - winding generally consists of aluminium foils pre-impregnated with hot polymerised resin. If necessary, ventilation ducts can be added, consisting of a pre-formed stainless steel or aluminium element. - winding generally consists of an aluminium circular section enamelled wire, wound using an ALSTOM patented method. This 60 oblique winding, named pyramidal, is then cast under vacuum into an eclusive casting system developed in our laboratories. This system comprises 3 components none of which include any halogens (epoy resin, anhydride hardener, mineral fillers), endowing it with a compact and homogeneous structure. Standards The HARMONY TM transformers are in accordance with standards : - IEC 726 et IEC 76- to 76-5 - HD 464.S + A2 and HD 538. S - NF C 52-726 and NF C 52-5

Electrical characteristics Dimensions and weights Rated power () (*) kva 60 250 400 630 800 000 250 600 2000 2500 rated voltage () kv 5,5 0 5 20 and dual 0/20 5/20 Rated insulation level () kv 7,2 for 5,5 2 for 0 7,5 for 5 24 for 20 kv Off-load secondary voltage () V 40 between phase, 237 between phase and neutral Adjustment () % ± 2,5 Vector group () Dyn (delta, star neutral brought out) Losses (W) no-load 650 880 200 650 2000 2300 2800 300 4000 5000 on-load (à 75 C) 2360 3320 4800 6800 8200 9600 450 4000 7500 20000 on-load (à 20 C) 2700 3800 5500 7800 9400 000 300 6000 20000 23000 Impedance voltage UCC % 6 No-load current Io % 2,5 2,,7,4,3,3,3,3,2, Voltage drop at full load cos ϕ %,85,69,55,4,35,27,22,8,8,0 cos ϕ 0,8 % 4,87 4,77 4,68 4,59 4,55 4,50 4,47 4,44 4,44 4,38 Efficiencies Charge 00% cos ϕ % 97,95 98,6 98,35 98,52 98,60 98,69 98,74 98,82 98,8 98,89 cos ϕ 0,8 % 97,45 97,7 97,95 98,6 98,25 98,36 98,43 98,53 98,52 98,62 Charge 75% cos ϕ % 98,22 98,42 98,59 98,74 98,80 98,88 98,93 99,00 98,99 99,05 cos ϕ 0,8 % 97,79 98,03 98,24 98,43 98,50 98,6 98,66 98,76 98,75 98,82 Noise level db(a) Acoustic power LWA 62 65 68 70 72 73 75 76 78 8 Acoustic pressure at m. LPA 50 53 55 57 58 59 6 62 63 66 Dimensions and weights IP 00 (2) H mm 65 295 375 585 625 670 735 795 228 2325 L mm 275 280 425 460 550 670 845 850 2030 2205 l mm 80 80 885 885 955 955 990 990 00 60 D mm 520 520 670 670 670 670 820 820 820 820 Weight kg 809 993 335 75 2055 252 320 3895 5065 6395 Dimensions and weights IP 3(2) H mm 620 620 830 830 2040 2040 2240 2240 2400 2530 L mm 620 620 830 830 2040 2040 2240 2240 2250 2550 P mm 850 850 925 925 995 995 030 030 40 200 Weight kg 95 95 25 25 255 255 300 300 445 495 () Other characteristics available on request. (*) The rated power is defined for continuous service with natural air cooling (AN). For special constraints, it can be increased by 40% by adding forced ventilation (AF). Details available on request. (2) These values are indicated for single 7,2 24 kv and 40 V voltages. As an eample, they can be used for 5/20 or 0/20 kv dual voltage transformers, ecept for 600 kva with protective enclosure (use dimensions of 2000 kva enclosure). For all other characteristics, these dimensions are not valid: details available on request. Transformer without enclosure - IP00 Lifting hole Neutral Protective enclosure - IP3 Removable lifting lugs Orientable lugs Tap changer link H H Removable panel Pulling holes M 2 2 Ø D D 25 (200) L l = 50 (80) - 2 = 38 (60) In italic : dimensions for 2000 and 2500 KVA D L Ø 25 (200) D P

Layout and connection guide Off-circuit tap changer links mounted on the front face are mandatory. Check that the ventilation system of the premises fully dissipates all losses. Transformer without enclosure (IP00) Since unprotected transformer (IP00) is installed inside premises, the following provisions must be taken : - Make sure that, when the transformer is energised, no person can touch it, even when it is equipped with plug-in bushings. - Eliminate all risk that drops of water can fall onto the transformer (in particular condensation on piping). - Comply with the minimum clearances to the walls of the room appropriate for the insulation voltages. Choice of and connections 6 possibilities are proposed. Details on all other configurations available on request. Standard 2 3 4 Fig. 5 and 6 : connection by plug-in terminals. 5 6 Minimum Distances minimales distances au to parois walls Insulation Solid walls Walls consisting (Rep.X) of meshing (Rep.Y) kv mm mm 7,2 90 300 2 20 300 7,5 ou 24 220 300 In accordance with standard NF C 3.00. Should it not be possible to comply these distances, please consult us. When the is brought out through the bottom, cable trenches must be provided also complying with the same distances (curvature of cable inside trench). y y Front face Meshing Transformer with IP 3 enclosure Indoor installation does not require any special precautions, ecept the compliance with a minimum clearance to the walls of the room. No special fire protection requirements are necessary (fire barrier ). Choice of and connections 7 possibilities are proposed. Details on all other configurations available on request. Standard 2 3 4 5 6 7 ;;;; 200mm Distance to ceiling 500mm Obstacle : wall, partition, or switchboard Fig. 5,6 and 7 : connection by plug-in terminals Fig.7: connection is provided by busbars. Connection by busducts is possible on request.

Equipments Standard equipment Transformer without enclosure (IP00) 3 connecting lugs at top of windings. 4 connecting lugs at top of windings. Off-circuit voltage regulation tap changer links. 4 swivel rollers. 4 lifting holes. earthing terminal at bottom. rating plate secured to side. Transformer with IP 3 enclosure Transformer without enclosure (IP00) protective enclosure IP3 (ecept the bottom IP2) removable : - anticorrosion treatment and final coat RAL 7038 grey colour. - 2 removable lifting lugs for handling transformer complete with its enclosure. - earthing terminal at bottom. - panel bolted to the front face, removable to gain access to the connections, equipped with 2 handles facilitating handling. - locking system for removable panel, lock not supplied. - removable panel earthing braid (to be connected on installation). - rating plate secured to the removable panel. - electrocution warning triangle. - undrilled anti-magnetic plate on the ceiling enabling cables to be lead through on the side and another on the side. Optional equipment or (and) connecting lugs at bottom. 3 plug-in bushings with 24 kv fied parts connected to connecting lugs. 3 plug-in bushings with straight or elbow connectors (in this case, it is imperative that the characteristics of the cable be indicated). plug-in bushing locking system, lock not provided. 4 busbar bushings (on protective enclosure only). protective cover (on protective enclosure only). thermal protection device : - 6 thermostatic detectors (2/phase) led back to a terminal block secured to the top part of the transformer. The contact can be of the open or closed type, or, - 6 PTC thermistors (2/phase) led back to a terminal block, associated to an electronic converter with 2 contacts ( for alarm, for tripping) separated delivery. Note : The characteristics and options indicated are preferential and not restrictive, others adaptations available on request.