Storing, Handling, and Cutting Steel Panels

Similar documents
E-Z BUILD STEEL BARN 12' 12' 12' 16' 12' 20'

Five Star Panel Installation Instructions

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

Tuff-Rib Install Guide

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

INSTALLATION INSTRUCTIONS LS X 12-2 X 7 1/2 FRAME LOAFING SHED

METAL ROOFING INSTALLATION GUIDE

Steel Roofing & Siding INSTALLATION GUIDE

GIRTS ON BACK OF BUILDING

Best Buy Metals Toll Free / Phone / Fax

DETAIL MANUAL for Standing Seam / Image II

Tuff-Rib. Installation Manual. Nationwide supplier of quality metal roofing. Toll-Free (800) S. Lee Hwy. Cleveland, TN 37311

REGAL. Installation Manual

Installation Guide. Step 3. Valley Flashing. Step 7. Transition Flashings and Accessories. Step 6. Hip and Ridge Installation

Tuff Rib Panel Installation Specifications

Chapter 16: Roof Steel

INSTALLATION INSTRUCTIONS 12' x 18' x 7' FRAME (12 x 20 x 7 ROOF COVERAGE) 2 SQUARE CARPORT

Table of Contents. Notes to Designer/User Map of Typical Roof Conditions Fastener Placement Fastener Selection...

Chapter 51: Sidewall Overhang(s) Only - Enclosed

Terrabella Shake & Shingle Znap Ver. 2.0

2 ½ Corrugated Panel Installation Specifications

PBR Panel Installation Specifications

Straight Rib Series Metal Roofing Panel Installation Guide

Table of Contents. Fasteners... 4 Venting Preparation Installation with Battens - DECRA Tile & DECRA Shake 1

DETAIL MANUAL. Metal Roofing Wholesalers. Classic Rib Roofing Panels

INSTALLATION GIUDE.

CertainTeed. Shake / Slate Installation Guide

Gambrel Barn with Overhang Manual

LUX INSTALLATION GUIDE. LUX Panel V Groove Installation. Installation Guide. February

A. B. MARTIN. Roofing Supply, llc. ABM Panel Installation & Trim Guide.

CARPORT INSTALLATION INSTRUCTIONS FOR 4 1/2 ON CENTER FRAMES

installation guide 7 8 Corrugated corrugated metal panel

Phone (662) Fax (662) DETAIL MANUAL. and guide to Reed s Metals products

Roof Only Lean-to Instruction Manual

GLOSSARY OF TERMS SECTION 8

TIOGA Table of Contents

Gambrel Barn Construction Manual 8x8 through 16x24 Units

Shed Assembly Instructions

INSTALLATION INSTRUCTIONS SUBURBAN SERIES CARPORT 25 X 20 X 6 LENGTH CAN BE EXTENDED IN 4 1/2 INCREMENTS HEIGHT CAN BE EXTENDED IN 1 INCREMENTS

Installation Instructions

7 X 10 X 6 SHELTER 7 X 16 X 6 SHELTER 12 X 10 X 6 SHELTER 12 X 16 X 6 SHELTER

DUTCH GABLE FREESTANDING CARPORT

MANUAL. Perma-Loc & Secure-Seam. Standing Seam Roofing Panels & Accessories. and guide to Town and Country Metals products

Table of Contents Light Gauge Metal Roof & Wall Panels

Table of Contents. Installation Guide for Profile with Hidden Fasteners 3. Installation Steps 4, 5. Prestige Series Moldings 6, 7. Other Accessories 8

Horizon-Loc. Installation Details 16" COVERAGE C GUID_INSTL_HLOC_160606

4-SIDED NAVAJO SHELTER ARIZONA MODEL INSTALLATION INSTRUCTIONS

WEB TRUSS ASSEMBLY MANUAL

Ultra-Rib Installation Manual

Installation Manual. Future Roof Shingle / Slate Products

Precut Value Shed Manual Gambrel Barn

GABLE ROOF CARPORT RECOMMENDED INSTRUCTION MANUAL

SteelChief Installation Instructions for pre-assembled panel form sheds GABLE ROOF

HOW TO Fix Onduline Corrugated Bitumen Sheets

installation guide Villa

Sheet Steel Facts. Most common head design for self-drilling, self-tapping screws.

MUELLER

ASSEMBLY INSTRUCTIONS FOR VERTICALLY SHEETED CARPORTS

CARPORT INSTALLATION INSTRUCTIONS FOR 4 1/2 ON CENTER FRAMES

UNIVERSAL INSTALLATION INSTRUCTIONS FOR CARPORTS

or Ordering Installation and Self-Help Guide

E N G L I S H GARDEN SHED. Assembly Instructions. Suitable for Models WITH VARYING DEPTHS

Ledger Board Lean-to Instruction Manual

POST FRAME CONSTRUCTION MANUAL

Installation Instructions Split Shake, Staggered Shake, Shingle, Perfection Shingle, and Shapes

Ledger Board Lean-to Instruction Manual

Chapter 23. Garage Construction

Classic Saltbox Manual

ASSEMBLY INSTRUCTIONS FOR VERSATUBE VERTICALLY SHEETED 2 x3 SINGLE SLOPE LOAFING SHED 12 W X 18 2 / 30 2 / 42 2 L X 8 / 10 6 ON CENTER FRAMES

CARPORT INSTALLATION INSTRUCTIONS FOR 4 1/2 ON CENTER FRAMES

UNIVERSAL ASSEMBLY INSTRUCTIONS FOR VERSATUBE FRONTIER GARAGE BUILDINGS

steel siding Residential Helpful Hints

Metal Roof Installation Manual. Chapter 14: Fasteners

IMPORTANT -- SPECIAL INSTALLATION INSTRUCTIONS

401 SW 33rd Ave Ocala, FL

DUTCH GABLE CARPORT RECOMMENDED INSTRUCTION MANUAL

Roofing Training - Basics. Sandy Wesch

Installation Manual. Last Updated 4 February, Postal PO Box 932 Bayswater VIC

Installation Guide. Please read before installing SIPs Kit. 1 Method Statement for the erection of a SIPS Industries Kit Materials...

Installation Guide. Capped Cellular PVC Fencing. Table of Contents. Storage and Handling Tools Needed Fence Layout and Locating Posts

Table of Contents. Important Notices 3. Residential Roofing Application 4. Trims & Accessories 5. Trim Glossary 6, 7, 8. Estimating Material 9

INSTALLATION PROCEDURE

RIDGEMASTER PLUS CAUTION INSTALLATION INSTRUCTIONS ALWAYS WEAR SAFETY GLASSES TOOLS NEEDED GENERAL GUIDELINES FOR RIDGEMASTER PLUS AND HIPMASTER

DETAIL MANUAL. For R-Panel / PBR Panel. Metal Roofing Wholesalers

Installation Guidelines

westmansteel.com Installation Guide Proudly Canadian. Family Owned. Cambridge (ON) TF. (855) F. (855)

VENTED GABLE DETAIL ROOF PANEL GABLE FLASHING 24" C/C MAX. BUTYL SEALANT TAPE ROOF PURLIN FLASH AB-1, AB-2, AB-3, OR AB-4

Table of Contents. Roof to Head Wall w/ Side Flashing DECRA Shake XD Roof Overview Roof Penetration - Pipes & Vents...

WESTERN WAVE Panel. Vertical Installation and Technical Information

Hugger Installation. Roof Hugger, LLC P: P.O. Box 1027 F: Odessa, FL

ROOF CURB INSTALLATION INSTRUCTIONS: VERTICAL STANDING SEAM PANEL

IRONSTONE SLATE & FLASHING SPECIFICATIONS IRONSTONE SLATE

NAIMA. Insulation Between (filling) Purlins and Over Purlins. What Does Metal Building Insulation Do? Installation Instructions for New Construction

NEVADA ASSEMBLY INSTRUCTIONS

Pacifica Pool House. Assembly Manual. Toll Free: Hours: 9-5 Monday-Friday EST. Package ships as shown. Suncast Corporation

C e r t a i n T e e d S h i n g l e A p p l i c a t o r s M a n u a l. and Carriage House STEEP. Slope Application. (over 21/12)

TABLE OF CONTENTS A. PBR

Keystone Garage Assembly Manual

SPAN-LINE 36A. Panel Information. Flashing Profiles. Accessory Profiles. Testing Information. Design/Installation Considerations.

Transcription:

Storing, Handling, and Cutting Steel s Storing Specifically check your quantities, colors, and lengths All materials should be used as soon as possible Steel bundles should be stored indoors with enough of a slope to allow any moisture from condensation to drain out of the bundle Bare galvanized panels should be installed immediately and not be stored outside Condensation or rain water trapped on bare galvanized panels can form a wet storage stain, also known as white rust. Handling Do not slide steel panels across each other. To properly lift a panel from the bundle place hands underneath the under lap side of the panel and lift up and away from the bundle. Lifting steel onto roof or building grab the panel in the flat of the panel and not in the rib. Bending steel is best done with a hand seamer or a brake press. Cutting s Tin Snips Nibbler Shears Cutting steel is best done with a shears, tin snips, nibblers, or panel shears. Cut edge does not require paint touch up. Shears Do not use a circular saw to cut steel panels. Steel Installation: Proper lapping of Steel Underseat Proper Overseat Proper lapping of steel panel is very important in the panel s ability to prevent leaking. The anti-syphon drain channel must be clear of debris and obstructions for the panel s ability to minimize the potential of capillary action of water from getting under the steel panel.

Fastener Installation: Proper Fastener Tightness Undertight Proper Overtight Fastener tightness is critical in the longevity of the fastener s ability to help prevent leaks and structural load carrying capacity. Over-torquing of screws will reduce the screw s withdrawal capacity, regardless of the construction materials involved. Under-torquing of screws will increase the potential of roof leaks. Fastener location is critical for installers to minimize the potential of oil canning, dimples, and other appearance related issues. Note: Both professional and first time installers have fewer problems with oil canning, dimples, and other appearance related fastener seating problems if they install them on top of the rib. Drill/Drivers: The correct choice of the drill/driver is essential to ensure the fastener can perform properly. A battery powered or corded drill/driver with the proper rpm speed is recommended. Application RPM Speed s to wood 2,500 s to metal - self-drill 2,000 s to metal - self-tap 1,000 The use of higher drill/driver for wood applications can result in overtightening or stripping out the fastener. Attempting to install self-drill fasteners into steel substrates with faster drills/drivers can result in fastener failure due to the points burning up. Impact drivers are NOT recommended for fastening panels. With the higher torque produced by these drivers, fasteners can be easily over driven to the point of the washer being over tightened or the fastener breaking. Additionally, the impacting action can cause excessive paint damage to the fastener heads and thread strip out. Fastener Specifications: Roof: Screws can be installed on top of the rib or in the flat surface of the panel between the ribs. Wall: Screws can be installed on top of the rib or in the flat surface between ribs. Screwing of Steel s Roof Sheets Peak & Eave of roof sheets Wall sheets -Use 2" Woodgrip screws on rib top or screws in the flat. -Use Woodgrip screws installed in the flat surface -Use Woodgrip screws installed in the flat surface Note: Screw lengths may need to be adjusted. Note: If an alternative fastening method is used, then the material list may have to be altered for proper fastener lengths.

Hanging Sidewall Steel Note: Optional Bottom Trim May be installed at this time. BOTTOM TRIM Note: Positioning of the first panel is critical. The first panel installed establishes the alignment and layout of the entire wall. It is very important that the first panel is accurately positioned and squared before fastening it in place. Wall Steel Tip: When laying out the steel panel have the overlap side of the panel away from the main line of sight. Tip: You may want to start at a corner away from the prevailing wind. Fig. 1 Grade Board Cut the first rib off leaving ¼ of rib on the first sheet of side steel (Fig. 1). Position the first panel so it is square in the corner. Make sure the first sheet of sidewall steel is level and the top of the sheet is even with the top edge of the edge purlin. This should leave approximately 3 of grade board exposed at the bottom (Fig.2). Using 1 screws, secure the top and bottom of the steel panel at the lap next to the rib, to assure proper lap and seating of the steel panel. Securing the panel in this manner will assure all laps to be seated and will not allow the steel to grow or stretch as you are running it. Once all the panels are in place and secure only at the lap, snap a chalk line at each mid-girt location and finish fastening the wall with 2 screws on top of the rib. At the top and bottom of the panels use 1½ fasteners on both sides of each rib, for the length of the building. Fig. 2 Steel ¼" Post Composite Grade Board Grade Note: Do not put fasteners on the rib at the top and bottom of the panel. Doing this may crush the end of the panel. Hanging Endwall Steel Endwall panels are fastened in the same manner as the sidewall panels. The only difference is the gable sheets are always started from the middle of the building and run towards the corners. The panels should be measured and the gable angle cut off of the top before installing the panels. Start

Installing Post Frame Roof Steel Note: Install optional Eave Trim before roof steel is installed. Note: Install optional inside closure strips before placing each roof panel. Be careful not to stretch the closure strips. Nail a temporary 2 4 block on the outside of each end truss extending 4" to 6" beyond the heel of the truss on both ends. The length that you extend the 2 4 will determine the overhang length. Inside Closure Strip Edge Purlin Run a mason line the full length of the building between these blocks. This mason line determines the length of the eave. Cut the first rib off leaving ¼" of rib on the first roof sheet of roof steel. Lay down the first roof steel panel, squaring it with the mason line. The roof panels are installed similar to the wall panels in layout. Using screws, fasten roof at top and bottom of the sheet in the flat next to each rib. All intermediate fasteners can be put on the rib or in the flat when using screws. Temporary 2 4 Desired Steel Overhang Nail Mason Line End Truss Edge Purlin Scratches A scratch in the panel may only cause rust if it is deep enough to cut through the paint and zinc coat. Color-matched touch-up paint is available if you happen to scratch a panel. Perfect for scratches and nicks Beveled brush great for tiny spots or thin lines. Color matched spray paint available for accessories 25 colors: 1 oz 156-7869 Touch-Up Paint Color Matched Spray can

Installing Residential Roof Steel The first panel on the roof should be ¼" in from the rake end and can overhang the roof edge a minimum of ¾" or a maximum of 3". This method is used as long as the roof plane is square. The panels will run square when placed on the roof. If the roof plane is out of square, compensation will need to be made in the placement of the steel. Most builders place the panels true to the eaves and not true to the rake to compensate for being out of square. Running true to the rake means compensation for square has to be made at the eaves line. This is a noticeable step in the panel from sheet to sheet. This usually looks like the panel at the eaves line is ¼" longer or shorter than the previous panel. It also makes the panel look like it has not been cut square at the end. Measure the diagonals on the roof. If the measurements of A and B are the same, then your roof is square. If the measurements are not the same, then adjustments may need to be made to run your steel correctly. A B For Pro-Rib and Premium Pro-Rib panels, the fasteners at the top and the bottom of the panel should be placed in the flat next to the rib. The first panel should be placed so the overlap side of the panel is towards the rake end of the roof. Ridge Rake Eave Overlap Overlap

Installing Residential Roof Steel Where does my second panel get placed? Whether you are using exposed or hidden fastener panels, the next panel should overlap the previous panel and be flush at the eaves end of the panel. 2 Over Lap s Flush 1 Where do fasteners go on the next panel installed? On exposed fastener panels, the overlap should always be fastened top to bottom to ensure a good lap of the panels. Properly seated lap prevents any leakage from capillary action. What if my panels are not lapped correct? A panel that is overlapped too much will cast shadow lines that will be noticed to the point where you can see every panel lap on the roof. A panel that is not lapped enough could show light through the lap. Both cases could result in a leak or aesthetic appearance problems. What about the Hidden Fastener panel lap? Install your first panel square on your roof. Then, while making sure panels are flush at the eaves edge, lightly compress and snap panels together at the seam. Snap the panels from eaves to ridge. Fasteners should not be spaced more than 36" on center in the fastening flange. The eaves also need to be fastened between the ribs. Three common methods are: 1) 2 residential roofing screws evenly spaced between the Ribs at the Eaves. 2) Steel Roof Edge fastened 1' on center with a pancake head screw and tape mastic applied to the roof edge. 3) Notch and cut out both the overlap and underlap of the hidden fastener panel ¾" from the eaves edge. Bend that eaves edge of the panel back on the underside and hook it onto the steel roof edge. Fasten with pancake head screws 12" on center.