Catenary and autotransformer coupled optimization for 2x25kV systems planning

Similar documents
AC INTERFERENCE OF TRANSMISSION LINES ON RAILWAYS: INFLUENCE OF TRACK-CONNECTED EQUIPMENT I. ABSTRACT

TECHNICAL MEMORANDUM

ACCURATE SIMULATION OF AC INTERFERENCE CAUSED BY ELECTRICAL POWER LINES: A PARAMETRIC ANALYSIS

Abstract. 1 Introduction

An Audio Frequency Model of a 2x25 kv Traction Line for High Speed Railway Systems

IFZONE PROJECT: IMPROVING CIRCULATION IN NEUTRAL SECTIONS. ADIF. Railway Technology Centre. Severo Ochoa, , Malaga, Spain.

Fast Front Transients in Transformer Connected to Gas Insulated Substations: (White+Black) Box Models and TDSF Monitoring

Analysis of Phenomena, that Affect the Distance Protection

JRC MODIFIED VOLTAGE CONTROL LAW FOR LOW FREQUENCY RAILWAY POWER SYSTEMS

Discussion on the Deterministic Approaches for Evaluating the Voltage Deviation due to Distributed Generation

Simulation and Analysis of Lightning on 345-kV Arrester Platform Ground-Leading Line Models

Voltage Sag Index Calculation Using an Electromagnetic Transients Program

The Effect of Fault States of the Twelve-pulse Rectifier During the Recuperation

Distance Protection of Cross-Bonded Transmission Cable-Systems

Identifying Long Term Voltage Stability Caused by Distribution Systems vs Transmission Systems

HV Substation Earthing Design for Mines

Harmonic and Unbalance Compensation Based on Direct Power Control for Traction Systems

Ballast Resistance Measurement Theory and Practice

Harmonic Distortion Levels Measured at The Enmax Substations

Busbars and lines are important elements

The power transformer

Optimal PMU Placement in Power System Considering the Measurement Redundancy

Fail Safe Operation of Audio Frequency Track Circuits for Railway Signalling C. Gautham Ram #1, A. Nithya #2, V. Jayashankar *3, P. R.

SAFETY ISSUES RELATED TO THE CONNECTION OF MV AND HV GROUNDING

C2-205 ANALYSIS AND SOLUTION OF TECHNICAL CONSTRAINTS IN THE SPANISH ELECTRICITY MARKET

Aggregated Rooftop PV Sizing in Distribution Feeder Considering Harmonic Distortion Limit

LARGE-SCALE WIND POWER INTEGRATION, VOLTAGE STABILITY LIMITS AND MODAL ANALYSIS

Ferroresonance Experience in UK: Simulations and Measurements

Analysis of lightning performance of 132KV transmission line by application of surge arresters

University of Zagreb Faculty of Electrical Engineering and Computing

Abstract. 1 Introduction

Fault Current Limiter Selection Considerations for Utility Engineers

The calculation of short-circuit current in the electrical design of traction substation

Effect of Controller Parameters on Pantograph-Catenary System

2 Grounding of power supply system neutral

Harmonic Analysis Model Based on 8-port Representation for Korean High Speed Railway

Ground Fault Isolation with Loads Fed from Separately Derived Grounded Sources

Basic Electronics Prof. Dr. Chitralekha Mahanta Department of Electronics and Communication Engineering Indian Institute of Technology, Guwahati

Active Smart Wires: An Inverter-less Static Series Compensator. Prof. Deepak Divan Fellow

Ground Fault Currents in Unit Generator-Transformer at Various NGR and Transformer Configurations

Improvement of Rotor Angle Stability and Dynamic Performance of AC/DC Interconnected Transmission System

Power Quality Notes 3-1 (AK)

Recent results on the Power Quality of Italian 2x25 kv 50 Hz railways

Lightning Flashover Rate of an Overhead Transmission Line Protected by Surge Arresters

Coordination of surge arresters in DC 3 kv railway traction system field tests

Extended Transmission Line Loadability Curve by Including Voltage Stability Constrains

When surge arres t ers are installed close to a power transformer, overvoltage TRANSFORMER IN GRID ABSTRACT KEYWORDS

A new method of DC power supply modelling for rapid transit railway system simulation Z.Y. Shao\ W.S. Chan", J. Allan* & B. Mellitt" Iz'rm'W, ^

Fatima Michael college of Engineering and Technology

A PARAMETRIC ANALYSIS OF AC INTERFERENCE CAUSED BY HIGH VOLTAGE POWER LINES ON NEIGHBORING RAILROAD TRACKS

A Novel Ground Fault Identification Method for 2 5 kv Railway Power Supply Systems

AEP s 765kV Transmission Line Model Validation for Short Circuit and System Studies. T. YANG, Q. QIU, Z. CAMPBELL American Electric Power USA

OVERVIEW OF IEEE STD GUIDE FOR VOLTAGE SAG INDICES

EE 741. Primary & Secondary Distribution Systems

EQ s & Frequency Processing

Maximum Allowable PV Penetration by Feeder Reconfiguration Considering Harmonic Distortion Limits

MV Network Operation Issues and Elimination of Phase Voltage Unbalance

Novel Simulation Method to Quantify Induced Voltage & Current between Parallel or Partially Parallel Proximity AC Transmission Circuits

ELECTRICAL POWER ENGINEERING

ENHANCEMENT OF POWER FLOW USING SSSC CONTROLLER

Neutral Reactor Optimization in order to Reduce Arc Extinction Time during Three-Phase Tripping

Stability Enhancement for Transmission Lines using Static Synchronous Series Compensator

MODERN COMPUTATIONAL METHODS FOR THE DESIGN AND ANALYSIS OF POWER SYSTEM GROUNDING

Improvement of Power System Distribution Quality Due to Using Dc-Converter Loads and Electric Arc Furnaces. H.A. Khalik, M. A. Aziz, and E. Farouk.

ISSN: X Impact factor: (Volume 3, Issue 6) Available online at Modeling and Analysis of Transformer

Testing Power Sources for Stability

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 4: (June 10, 2013) Page 1 of 75

Electrification Infrastructure Reducing Whole Life Cost

Research on the modeling of the impedance match bond at station track circuit in Chinese high-speed railway

UNIT 3: FIELD EFFECT TRANSISTORS

Case Study 1. Power System Planning and Design: Power Plant, Transmission Lines, and Substations

A Comparison of the Ladder and Full-Order Magnetic Models

Power Transmission of AC-DC Supply in a Single Composite Conductor

PRC Generator Relay Loadability. Guidelines and Technical Basis Draft 5: (August 2, 2013) Page 1 of 76

Transmission Line Models Part 1

Improving High Voltage Power System Performance. Using Arc Suppression Coils

Document C-29. Procedures for System Modeling: Data Requirements & Facility Ratings. January 5 th, 2016 TFSS Revisions Clean Open Process Posting

ESB National Grid Transmission Planning Criteria

Central Hudson Gas & Electric Corporation. Transmission Planning Guidelines

Simultaneous AC-DC Transmission Scheme Under Unbalanced Load Condition

Testing model data usability Excitation Systems PSS Limiters

POWER SYSTEM ANALYSIS TADP 641 SETTING OF OVERCURRENT RELAYS

Ferroresonance in MV Voltage Transformers: Pragmatic experimental approach towards investigation of risk and mitigating strategy

ADVANCED CONTROLS FOR MITIGATION OF FLICKER USING DOUBLY-FED ASYNCHRONOUS WIND TURBINE-GENERATORS

Electromagnetic Compatibility of Train Detection Infrastructure with Rail Vehicles

Chapter 8: Field Effect Transistors

GRID CODE COMPATIBLE PROTECTION SCHEME FOR SMART GRIDS

LONGITUDINAL INDUCTION VOLTAGE MEASUREMENT ON COMMUNICATION CABLES RUNNING PARALLEL TO OVERHEAD LINES

SIGNAL CONDITIONING FOR CRYOGENIC THERMOMETRY IN THE LHC

HARMONICS ANALYSIS USING SEQUENTIAL-TIME SIMULATION FOR ADDRESSING SMART GRID CHALLENGES

Experimental validation of the electric network model of the Italian 2x25 kv 50 Hz railway

ABB conductivity analyzer and probe package

Capstone Turbine Corporation Nordhoff Street Chatsworth CA USA Phone: (818) Fax: (818) Web:

Power Quality Issues in Traction Power Systems

Overvoltage Protection of Light Railway Transportation Systems

Gareth Evans STV. Peter Tabolt STV. Boston, MA. Philadelphia, PA. Simulation and Mitigation of Magnetic Field Created By Traction Power Systems

Survival Skills for Circuit Analysis

Evaluation of coupling between dc and ac transmission lines on the same right-of-way: Parametric analysis and mitigation methods

energies Article Carlos A. Platero 1, * ID, Jesús Serrano 1, Máximo López-Toledo 1 and Ricardo Granizo 2 ID

Understanding Power Splitters

Transcription:

Power Supply System Analysis, Design and Planning 113 Catenary and autotransformer coupled optimization for 2x25kV systems planning E. Pilo, L. Rouco & A. Fernández Instituto de Investigación Tecnológica, E.T.S. de Ingeniería ICAI, Univ. P. Comillas, Madrid, Spain Abstract In the design process of a 2x25kV power supply, the location and sizing of autotransformers and the choice of the catenary type are usually two aspects very closely interrelated. As a result, the number of autotransformers can normally be reduced or augmented if the catenary is upgraded or downgraded respectively. In this paper, coupling equations between these two aspects are described in detail. These equations are used to formulate a multi-attribute optimization problem in which the global efficiency of the investment is optimized. In this problem, the considered attributes are: (i) investment cost and (ii) a performance index that is defined in the paper. The optimization procedure gives a reduced set of catenary and autotransformers combinations that maximize efficiency. This optimal reduced set can be used as an input in the design process of power supply. For the solution of this problem, different dominancy criteria are evaluated. Furthermore, sensitivity studies are carried out during the optimization process to help in the search of catenary and autotransformers combinations. As a study case, the proposed optimization procedure has been used to obtain a reduced set of catenaries and autotransformers based in the catenary C-350, which has been used in the Madrid Barcelona French border new high-speed line. Keywords: power supply system, high speed railways, multi-attribute optimization, long-term infrastructure planning. 1 Introduction In the design process of a 2x25kV power supply, the location and sizing of autotransformers and the choice of the catenary type are usually two aspects very doi:10.2495/978-1-84564-498- 7/ 12

114 Power Supply, Energy Management and Catenary Problems closely interrelated. As a result, the number of autotransformers can normally be reduced or augmented if the catenary is upgraded or downgraded respectively. In this paper these relationships are analyzed and used to formulate a multi-attribute optimization problem in which the global efficiency of the investment is optimized [1]. Section 2 describes the power supply system of AC-electrified railways. In section 3 an equivalent model is used to represent bi-voltage 2x25kV and to analyze the relationships between catenary parameters and autotransformers separation. In section 4 the optimization problem is described. In section 5 the optimization procedure is applied to a real case. Finally, in section 6 the conclusions of this work are presented. 2 The power supply of AC electrified railways 2.1 General structure Figure 1 shows the general structure of power-supply systems of AC electrified railways: Three-phase high-voltage network Traction substation 1 Traction substation 2 Traction substation 3 Sector 1-L Sector 1-R Sector 2-L Sector 2-R Sector 3-L Sector 3-R Figure 1: Structure of the power supply system. As shown, the electrical system is divided in electrically-isolated singlephased sectors, which are fed from the three-phase network through a traction substation. These substations are connected between two of the three phases of the high-voltage network. Each of these sectors can use either mono-voltage system (1x25kV) or bi-voltage system (2x25kV). In mono-voltage systems [2], the feeding conductors are set to the specified voltage level (see Figure 2). V transp V feed POS Figure 2: Mono-voltage system configuration. In bi-voltage systems, a higher voltage is set between feeding conductors [3, 4]. This voltage is reduced by using autotransformers distributed along the

Power Supply System Analysis, Design and Planning 115 catenary (see Figure 3). In these systems, the term very often refers to the portion of catenary located between two consecutive autotransformers. Typical values for lengths are 10-15km. V transp V feed POS V feed NEG Figure 3: Bi-voltage system configuration. As this paper is focused on this system, it is assumed that all the sectors are fed using bi-voltage system. 2.2 Catenary The typical configuration of the catenary of an AC railway line is shown in Figure 4. The catenary contains several physical conductors that can be grouped into three groups: positive, negative and ground wires. In case of multiple tracks, other conductor arrangements are possible. Positive Negative Neutral Positive feeder Sustainer Negative Feeder Contact wire Return wire Rail Longitudinal section Transversal section Figure 4: Typical conductor distribution. The positive wires are the positive feeder, the sustainer wire and the contact wire. There is usually only one negative wire called negative feeder. The ground wires are the rail, the collector wire and the return wire. The conductors of each group are connected between them at regular intervals (typically 300m). Additionally, ground conductors are frequently connected to earth.

116 Power Supply, Energy Management and Catenary Problems 3 The effect of autotransformers and catenary upgrades 3.1 Base magnitudes In order to improve numerical stability, normally per unit magnitudes are used to carry out all the necessary calculations. Thus, the circuit can be divided into three zones based on their nominal voltage. Figure 5 shows the considered zones: (i) high-voltage zone, (ii) positive zone and (iii) negative zone. High voltage Positive zone K1:1 Ztr2 Train 1 Zthevenin Ztr1 Zcat Zcat Zcat Ztr3 Vthevenin K2:-1-1:1-1:1 Negative zone Figure 5: Zone division for base magnitudes selection. A base power S base has to be chosen and is common to all the zones (a typical value is 10MW). Furthermore, base voltages have to be selected for the three zones. If base voltages are exactly the voltages of every zone in a scenario without any kind of load, transformation ratios take values of 1 and 1. Base impedance and base currents can be determined from the base power and voltage of each zone. 3.2 The 1x25kV equivalent model of 2x25kV systems In [5] the behavior of bi-voltage systems is analyzed and a equivalent model is proposed to represent bi-voltage 2x25kV systems as if they were mono-voltage 1x25kV. This is the model used in the presented work. Figure 6 shows the approximated behavior of the circuit with a train consuming a current I, assuming: (i) that voltage drop along a in the positive and in the negative side have the same value but different sign and (ii) that, as far as autotransformers can be supposed ideal, it can be assumed that there are current flows only in the autotransformers that are immediately adjacent to the considered train. In this figure V n is the voltage drop along the n, I p,trans and In,trans are respectively the positive and negative currents in the transmission s, I p,train and I n,train are respectively the positive and negative currents in the of the train, L is the length of the of the train, x is the relative position of the train, expressed as a fraction of L.

Power Supply System Analysis, Design and Planning 117 Ip,trans AT1 Ip,train In,train AT2 V1 V2 V3 V4 I V5 V6 I0 xl VHV L -V1 -V2 -V3 -V4 -V5 -V6 In,trans In,train Transmission Transmission Transmission Cell of the train Downwards Downwards Figure 6: Approximated behavior of bi-voltage system. Based on these simplifications, the positive phase of the bi-voltage system can be represented as shown in Figure 7. In this model, two different contributions have been identified: (i) the equivalent impedance of the catenary z that depends only on the configuration of physical conductors and (ii) eqv, cat z that is associated to the separation between autotransformers. Zeqv,SS Zeqv,cat Positive Z Vthevenin Train High Voltage Network Transformer Catenary Ground Figure 7: Mono-voltage equivalent circuit of bi-voltage system. The parameters of this equivalent circuit are calculated as follows: z = z D (1) eqv, cat eqv, cat ss, train where the symbol ~ is used to refer per length unit magnitudes and D ss, train is the distance between the substation and the train The equivalent impedance z eqv, cat of the catenary can be obtained from the elements of the equivalent conductors impedance matrix [6], where the subindexes p and n represents the positive and negative conductors respectively. z eqv, cat z z z z = z + z + z + z pp nn pn np pp nn pn np The impedance z associated to the separation of autotransformers can be obtained as follows: (2)

118 Power Supply, Energy Management and Catenary Problems z ( 1 ) = L x x z + z z + z z + z z 2 pp pp np pn pp pn np z + z + z + z pp pn np nn The voltage drop associated to the impedance z is referred as voltage deviation from the equivalent model of the catenary. As shown in Figure 8, this voltage deviation starts and ends in in which is located the train. In other words, at the end of this all the voltage deviation is recovered and thus no extra voltage drop has to be added to the trains that are located downwards. Figure 8 summarizes the voltage drops in the sector in a scenario with only one train: (3) Traction Substation V SS 1 V AT1 -V AT2 2 VAT1-Vtrain 3 Z itrain A.T. 1 Train A.T. 2 X AT1 X train X AT2 (km) V CAT dv/dx=z eq,cat I train 1 2 3 (V) Figure 8: Voltage drops in a bi-voltage sector. It can be seen that the deviation impedance is proportional to the distance between autotransformers. Consequently, as far as the number of autotransformers is increased, the relative weight of the deviation is reduced. 3.3 Influence of catenary type and autotransformers distance on voltages Using the described model, sensitivity of the voltage drops to catenary upgrades or to autotransformer additions can be analyzed. These are two common investment decisions to be taken in the design process of the power supply in bi-voltage 2x25kV electrified railways. Figure 9 shows the effect of upgrading the catenary in the voltage drops along the catenary V. When upgrading the catenary, the most important effect is a cat reduction of voltage drops all along the sector. Additionally, the voltage drop due the separation autotransformers (corresponding to z ) can also be reduced. Figure 10 shows the effect of shortening the distance between consecutive autotransformers, which is typically achieved by adding extra autotransformers to the sector. Unlike the catenary upgrade, the benefits of this enhancement are limited to the whose distance has been reduced, due to the local influence of voltage deviations VDESV.

Power Supply System Analysis, Design and Planning 119 V (in kv) V (in kv) VSE VSE Vcat Vcat X (in m) X (in m) SS Train 1 Train 2 SS Train 1 Train 2 Figure 9: Effect of upgrading the catenary. V VDESV VDESV SS Train AT1 AT2 AT1 AT2 x Figure 10: Effect of shortening length of s. As it has been described, both catenary upgrades and autotransformer additions can be used to reduce voltage drops. 4 The optimization problem In the design process of AC-electrified railways, voltage limitations are commonly active, especially when evaluated in degraded situations (substation out of order). Thus, determining the most efficient way of reducing voltage drops is a key factor in the design of the power supply. As it has been described, catenary upgrades and autotransformer additions are often investment decisions that are exchangeable in order to reduce voltage drops, from a technical point of view. Therefore, economical criteria have to be considered to determine the most efficient combination of catenaries and autotransformer distributions. For that reason, a multi-criteria optimization problem has been formulated and solved. The goal of this optimization is to obtain a reduced repository of combinations of catenary types and autotransformer distributions, in which the efficiency of its elements is maximized. This set is to be used as an input in the

120 Power Supply, Energy Management and Catenary Problems design of the power supply system. To determine this repository, the considered attributes are: (i) investment cost and (ii) a efficiency index that is to be defined. In order to evaluate the efficiency of each {catenary,autotransformers} combination the efficiency index ZEQ is defined in eqn. (4). This index corresponds to the total equivalent impedance seen between the substation output and a train located in the further of the corresponding sector. In order to simplify the resulting expression, it has been assumed that autotransformers are uniformly distributed. n 1 L ZEQ = z eq, cat L+ x + n n z (4) where n is the number of autotransformers of this sector and L is the length of this sector. Expanding z in eqn. (4) becomes: n 1 L ZEQ = z eq, cat L+ x + ( pp eq, cat ) x( 1 x) L n n z z (5) n As ZEQ depends on the relative position x of the train in its, one of the following criteria for can be assumed: a. The train is located in the middle of its ( x = 0.5 ) b. The train is located where the index ZEQ reaches its maximum. It should be noted that ZEQ incorporates the effect of both catenary type and autotransformers in an equilibrated manner, as it corresponds to their contribution in the total voltage drops. The considered cost function is: C = C L+ C n (6) cat, n cat AT where C cat, n is the cost associated to catenary cat with n autotransformers, C cat is the per length unit cost of the catenary cat and C AT is the unitary cost of each autotransformer. To get the optimal repository the following steps have to be accomplished: a) Exploration of the possible catenary/autotransformer configurations. As the sustainers and the contact wires are fixed, the number of combinations is not excessive. Symmetry restrictions can also be used to reduce the search space. b) Eliminate dominated configurations (a configuration is dominated if it is worse in cost and in efficiency than another configuration). Relaxed dominancy criteria can also be applied in order the eliminate configurations (i) a bit cheaper but much lower efficiency or (ii) a bit more efficient but much more expensive. c) Within the resulting repository, chose the final configurations trying to cover uniformly the costs range.

Power Supply System Analysis, Design and Planning 121 5 Study case The proposed optimization procedure has been used to get a repository of catenaries and autotransformers based on the catenary C-350 that has been used in the Madrid Barcelona French border new high-speed line. The considered costs are summarized in Table 1. Table 1: Costs structure of the study case. Description Cost Observations Autotransformer 200 units Cost per autotransformer Fixed cost of catenary 29 units/km Includes installation of catenary towers, insulators, contact wires and sustainers Cost per added feeder 0.3 units/km/feeder Only in configurations with positive or negative feeder LA-110 conductor 0.716 units/km To be included only if used LA-180 conductor 0.832 units/km To be included only if used LA-280 conductor 0.95 units/km To be included only if used LA-380 conductor 0.125 units/km To be included only if used Figure 11 shows the 5 catenary/autotransformers combinations chosen (marked with arrows), that have been evaluated for sector 30km, 40km and 50km long. Figure 11: Effect of shortening length of s.

122 Power Supply, Energy Management and Catenary Problems Each curve represents the effect of adding up to 5 autotransformers to the catenary specified, for the given sector length. As shown in Figure 11, the efficiency gain of upgrading catenary (change to a lower curve of the same family) is normally a more efficient option than adding an extra autotransformer (go to the following point of the same curve). It can also be observed that the efficiency of adding autotransformers decreases very quickly and, thus, none of the chosen configurations uses more than 2 autotransformers. 6 Conclusions Using the mono-voltage equivalent model of bi-voltage systems, the existing relationships between the location of autotransformers and the choice of the catenary have been analyzed. Furthermore, a procedure has been proposed to obtain a reduced repository of combinations of catenary types and number of autotransformers in which efficiency and cost are optimized As a study case, the proposed optimization procedure has been used to obtain a reduced set of catenaries and autotransformers based in the catenary C-350, which has been used in the Madrid Barcelona French border new high-speed line. The solution obtained in the study case suggests that upgrading catenary is normally a much more efficient option than adding an extra autotransformer. The reason for that is that the marginal cost of using larger conductors in the catenary can be neglected compared to the marginal cost of adding an autotransformer. References [1] E. Pilo, Optimización del Diseño de la Electrificación de Trenes de Alta Velocidad, in IIT, vol. PhD: Univ. Pont. Comillas de Madrid, 2003. [2] J. D. Glover, A. Kusko, and S. M. Peeran, Train voltage analysis for AC railroad electrification, IEEE Transactions on Industry Applications, vol. IA-20, pp. 925-934, 1984. [3] R. J. Hill and I. H. Cevik, On-line simulation of voltage regulation in autotransformer-fed AC electric railroad traction networks, IEEE Transactions on Vehicular Technology, vol. 42, pp. 365-372, 1993. [4] P. H. Hsi, S. L. Chen, and R. J. Li, Simulating on-line dynamic voltages of multiple trains under real operating conditions for AC railways, IEEE Transactions on Power Systems, vol. 14, pp. 452-459, 1999. [5] E. Pilo, L. Rouco, and A. Fernández, A reduced representation of 2x25 kv electrical systems for high-speed railways., presented at IEEE/ASME Joint Rail Conference, Chicago, 2003. [6] E. Pilo, L. Rouco, A. Fernández, and A. Hernández-Velilla, A simulation tool for the design of the electrical supply system of high-speed railway lines, presented at IEEE PES Summer meeting 2000, Seattle, 2000.