The all-in-one solution for wireless recording and stimulating in vivo

Similar documents
Wireless Neural Loggers

TBSI W256 System Manual Version 1.0

TBSI W32 System Manual Version 3.0

from signals to sources asa-lab turnkey solution for ERP research

CerePlex W. Instructions for Use. 630 Komas Drive Suite 200 Salt Lake City UT USA P F

An 8-Channel General-Purpose Analog Front- End for Biopotential Signal Measurement

KMT - Kraus Messtechnik GmbH

TDT Biological Amplifier User s Guide? TDT

ISOBE5600. Data sheet. Isolated Probe Systems. - ISOBE5600 Isolation system - ISOBE5600 Transient recorder. Features and Benefits

APPENDIX E: IWX214 HARDWARE MANUAL

1510A PRECISION SIGNAL SIMULATOR

KMT - Kraus Messtechnik GmbH

SL Handheld Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

Telemetrie-Messtechnik Schnorrenberg

Extracellular recording with microelectrode arrays for all applications

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE EXT-02 B EXTRACELLULAR AMPLIFIER

Your reference in Neuroscience Research. Neuroscience Suite

SL Headmic Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

CAEMAX D x telemetry. digital modular convenient. Modular, multi-channel telemetry system for a variety of applications. productive testing

Weld Checkers. Resistance welding derives it s ability to form a proper weld nugget from the simple formula

Bio-signal research. Julita de la Vega Arias. ACHI January 30 - February 4, Valencia, Spain

Digital Telemetry Solutions

C4000. inline control. Photometric Converter. Real-time photometric converter. Factory zero for scattered light sensors

Making Your Tour. State of the Art. TourGuide 2020-D

Spectrum Analyzer. Spectrum Analyzer. Antenna Panel Inputs. Auxiliary Antenna Inputs. Two models available: 24 GHz and 8 GHz OSCOR

SL Lavalier Set. Product specification FEATURES SPECIFICATIONS DELIVERY INCLUDES

Analog Technologies. Noise Measurement Amplifier ATNMA2 Noise Measurement Amplifier

Optimized testing of electric drives

Digital Telemetry Solutions

HL 675 Data / Impulse Transmitter set User Manual

Analysis of static and time-variable magnetic fields

Green ADVANTAGES. Spectrum Analyzer Two models available: 24 GHz and 8 GHz SPECTRUM ANALYZER. Antenna Panel Inputs. Auxiliary Antenna Inputs OSCOR

MT32 Telemetry. KMT - Kraus Messtechnik GmbH. Multi channel telemetry system for rotating application. Powering (rotor) by battery or inductive

Typical Doppler Signal Amplifier Application Note AN-04

GV-700 VIBE PORT. Installation and. Operating Manual

Electroencephalograph EEG-1200J/K

No part of this document may be reproduced or transmitted without the express written permission of Multi Channel Systems MCS GmbH.

EMG Sensor Shirt. Senior Project Written Hardware Description April 28, 2015 ETEC 474. By: Dylan Kleist Joshua Goertz

QUICK SETUP GUIDE SECULIFE HITAM

TG 500 DRAHTLOSSYSTEM TG 500 PROFESSIONAL WIRELESS SYSTEM GREAT PERFORMER. CAT_TG500_17-07_EN_210x280_RZ.indd :17

potentiostat/galvanostat/impedance analyser

WMS 450 Wireless Microphone System

PDL 650. Acoustic PD Fault Localization in High-Voltage Equipment

SpeechLine Digital Wireless SL Headmic Set

Digital 6000 SK 6000 Bodypack transmitter

Neurophysiology Research

ni.com Sensor Measurement Fundamentals Series

Biomedical Sensor Systems Laboratory. Institute for Neural Engineering Graz University of Technology

SpeechLine Digital Wireless SL Lavalier Set

HL 670 Data / Impulse Transmitter set User Manual. Version 07/2010

Chapter 4 4. Optoelectronic Acquisition System Design

NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING

PSM1000. In-Ear Personal Monitoring Systems. PSM1000 In-Ear Personal Systems THE SOUND OF CONFIDENCE.

EMC/EMI MEASURING INSTRUMENTS & ACCESSORIES SHORT-FORM CATALOG 2011

ISO-80. Isolated Differential Amplifier. INSTRUCTION MANUAL. Serial No. World Precision Instruments

Narda EMF drive test solution

CTP16-Rotate. KMT - Kraus Messtechnik GmbH

TS-900/800 SERIES INFRARED WIRELESS CONFERENCE SYSTEM

NHT 3DL. The new landmark meter for electromagnetic safety. Percipere Aestimare et Inquirere

Your partner for reliable detection technology

MPD 600. High-End Measurement and Analysis System for Partial Discharges (PD)

Stimulus Generator Manual STG 4004 and STG 4008

AVL X-ion. Adapts. Acquires. Inspires.

VLR-502 Wireless System. Owner s Guide

ELECTRONIC DESIGN & ENGINEERING. ICP_FM3 Versatile DC AC IEPE Signal Conditioning. 1 ICP_FM3 Introduction

Portable Wideband Jamming System - PWJ1 Developed and manufactured in Germany

Exposure Level Tester ELT-400

Bechrasoft Srl. Price List. Model Description Internal Price. Vehicle 4G GPS WIFI Cell Phone Jammer TG-101A 6 405,00

SL TS 133 GN Set DW FEATURES

Why partial discharge testing makes good sense

FAG Detector II the mobile among data collectors. Technical Product Information

Weld Checkers RESISTANCE WELDING

Ground vibration testing: Applying structural analysis with imc products and solutions

Immunity Test System RIS 3000 / RIS 6000 acc. to IEC/EN

DEDICATED TO SPEECH. Experience Simplicity with SpeechLine Digital Wireless

MEA Amplifier for Inverse Microscopes Manual

SL TS 153 GN-L Set DW

Series GLET Accessory for dataloggers series GL in modular enclosure

Brain Computer Interface Control of a Virtual Robotic System based on SSVEP and EEG Signal

evolution wireless G4 ew 100 G4-835-S ew 100 G4-845-S ew 100 G4-865-S Vocal Set

potentiostat/galvanostat/impedance analyser

MAGNETIC FIELD METER Operator s Manual

UNIVERSITY OF CALIFORNIA College of Engineering Department of Electrical Engineering and Computer Sciences

TA-80. Digital Plug-on Transmitter

Potentiostat/Galvanostat/Zero Resistance Ammeter

MAGNETIC FIELD METER Operator s Manual

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

Test Plan for Hearing Aid Compatibility

SpeechLine Digital Wireless SL Boundary Set DW

OPERATING INSTRUCTIONS AND SYSTEM DESCRIPTION FOR THE TEC-B-01M VOLTAGE CLAMP MODULE FOR EPMS SYSTEMS. VERSION 1.2 npi 2014

GENERAL OPERATING INFORMATION

AD8232 EVALUATION BOARD DOCUMENTATION

CSM High-Voltage Measurement Systems

Analog Circuits and Systems

D10 Demonstration Board

Cable Identifier Reliable cable selection for energised and de-energised cables

*Most details of this presentation obtain from Behrouz A. Forouzan. Data Communications and Networking, 5 th edition textbook

MEA Amplifier for Upright Microscopes Manual

Selective and broadband high frequency field analysis

Wireless Animal Monitoring

Transcription:

Wireless-Systems The all-in-one solution for wireless recording and stimulating in vivo 4, 8, 16 or 32 channels Options for electrical and optical Lightweight headstages Excellent signal--noise ratio Parallel recordings possible Option access analog data

Energy-efficiency and flexibility Key advantage: Digital data transmission The Wireless-System converts Versatile software: Multi Channel Suite All devices of the Wireless-Systems are designed be recording continues, the headstage switches on The Wireless-System comes with the powerful and easy--use software package Multi energy-efficient. The standard battery of the headstage aumatically. Another possibility is turn off the Channel Suite. It consists of three programs and updates are available for free from converter and LED lights for video, permits continuous recording of all channels for approx. headstage completely via the data acquisition software. the MCS website. Systems is the all-in-one solution for digitized transmission, powerful receiver, 2 hours (details on back side). Recharging is then For switching on without any interference, just use the amplifying, recording, and analyzing in vivo interface board, and data acquisition Multi Channel Experimenter for data acquisition and online analysis. With an easy- realized via a USB charger. included infrared flashlight which does not disturb the data from 4, 8, 16 or 32 channels. software package. -use drag n drop interface, you simply create your virtual experiment adding e.g. For recording in animals insensitive weight, we also animal. data source, filters, spike detection, and recorder. Battery level and signal quality are The bandwidth is 1 Hz 5 khz, With its excellent signal--noise ratio, offer larger batteries, which provide longer recording Single channels can always be switched on and off for indicated here and your data is displayed in real-time. Modular setup of headstages sampled at up 40 khz per channel it is the ideal solution for recording times. Please contact Multi Channel Systems for more recording via software. This allows you adjust energy Multi Channel Analyzer for offline analysis. You just import the recorded data and The wireless headstages are built accord- simultaneously. With a resolution of 16 bit, spikes, LFP, EEG, ECG, EMG, and ECoG. information on battery options. and sampling rate whenever you like. define your in-depth analysis with additional instruments. The Multi Channel Analyzer ing your needs. The level-based con- the accuracy of your data is guaranteed. Additional inputs the interface board also supports synchronized video input for behavioral research with freely moving struction makes cusm-built headstages The systems include everything you need: allow the synchronization of your data with For power-saving, the headstage switches stand-by possible. Your headstage can consist of Small-sized headstage with integrated A/D external devices. mode as soon as the data acquisition is spped. When animals. Both, the video data and electrophysiological recordings are displayed in parallel and you can easily skip through the data from one event the next. levels for amplification and A/D conver- Multi Channel DataManager for data export for further analysis with third- sion, electrical or optical, party programs. Data files are exported in HDF5 (e.g. Matlab, Python),.nex motion sensors and many more which (Neuroexplorer) or.ced (Spike 2). Independent of the file format, the export is done are currently under development. Wireless recording system The Wireless-System from Multi Channel the recorded signals in digital data already on the headstage. Headstage A/D converter and transmitter Digital Wireless Transmission Receiver Microprocessor Interface Board Connection computer Software Data visualization and analysis Aumatically when spping data acquisition Switching via control software quickly and a data compresssion is included. This guarantees an excellent signal-noise ratio which is independent Any PC or lapp can be used from the distance between sender and receiver. Active Recording Stand-By Switched Off Low battery Marginal battery In combination with a long transmission Aumatically when starting data acquisition range, the digital data transmission permits flexible long-term experiments Switching via infrared flashlight, included in the system in large environments. and optical MCS uniquely provides headstages for optical and electrical. You do not need give up valuable recording information while stimulating; the headstages allow you Analog output any data acquistion Various possibilities for battery placement and electrode connections record and stimulate simultaneously! The headstage for optical offers an interface For maximum flexibility, we offer headstages with 2 LEDs. So in addition 4 recording channels, you connections any type of probes. Just let us know Generally, the Wireless-Systems are com- can program 2 patterns for the connected plete work stations with data acquisition LEDs. Parallel experiments The headstage for electrical has 2 dedicated The Wireless-System offers the possibility channels with current output in addition either 8 or 14 recording channels. simultaneously and software from Multi Channel Systems. However, you have the option add an analog output of all channels. as well as electrical patterns can be You can then connect your existing data designed freely via the included software Multi Channel acquisition and analyze the data in your Experimenter. software. This gives you the flexibility integrate the MCS-Wireless-System in your existing set-up and use the peripheral equipment you are familiar with - while adding valuable, undisturbed in vivo data. record from up which probe you want use and we will provide the eight one setup animals corresponding connecr. Moreover, depending on your experiment, you can also a decide where position the battery of the headstage. reduced sampling rate). Up four receivers Either fix it on the headstage itself or use a special backpack can be run in parallel in the same room, for the cable-connected battery. Independent of your with a tal number of 16 headstages. decision, be sure that the battery is small and lightweight in with (at order not influence your experiment.

Energy-efficiency and flexibility Key advantage: Digital data transmission The Wireless-System converts Versatile software: Multi Channel Suite All devices of the Wireless-Systems are designed be recording continues, the headstage switches on The Wireless-System comes with the powerful and easy--use software package Multi energy-efficient. The standard battery of the headstage aumatically. Another possibility is turn off the Channel Suite. It consists of three programs and updates are available for free from converter and LED lights for video, permits continuous recording of all channels for approx. headstage completely via the data acquisition software. the MCS website. Systems is the all-in-one solution for digitized transmission, powerful receiver, 2 hours (details on back side). Recharging is then For switching on without any interference, just use the amplifying, recording, and analyzing in vivo interface board, and data acquisition Multi Channel Experimenter for data acquisition and online analysis. With an easy- realized via a USB charger. included infrared flashlight which does not disturb the data from 4, 8, 16 or 32 channels. software package. -use drag n drop interface, you simply create your virtual experiment adding e.g. For recording in animals insensitive weight, we also animal. data source, filters, spike detection, and recorder. Battery level and signal quality are The bandwidth is 1 Hz 5 khz, With its excellent signal--noise ratio, offer larger batteries, which provide longer recording Single channels can always be switched on and off for indicated here and your data is displayed in real-time. Modular setup of headstages sampled at up 40 khz per channel it is the ideal solution for recording times. Please contact Multi Channel Systems for more recording via software. This allows you adjust energy Multi Channel Analyzer for offline analysis. You just import the recorded data and The wireless headstages are built accord- simultaneously. With a resolution of 16 bit, spikes, LFP, EEG, ECG, EMG, and ECoG. information on battery options. and sampling rate whenever you like. define your in-depth analysis with additional instruments. The Multi Channel Analyzer ing your needs. The level-based con- the accuracy of your data is guaranteed. Additional inputs the interface board also supports synchronized video input for behavioral research with freely moving struction makes cusm-built headstages The systems include everything you need: allow the synchronization of your data with For power-saving, the headstage switches stand-by possible. Your headstage can consist of Small-sized headstage with integrated A/D external devices. mode as soon as the data acquisition is spped. When animals. Both, the video data and electrophysiological recordings are displayed in parallel and you can easily skip through the data from one event the next. levels for amplification and A/D conver- Multi Channel DataManager for data export for further analysis with third- sion, electrical or optical, party programs. Data files are exported in HDF5 (e.g. Matlab, Python),.nex motion sensors and many more which (Neuroexplorer) or.ced (Spike 2). Independent of the file format, the export is done are currently under development. Wireless recording system The Wireless-System from Multi Channel the recorded signals in digital data already on the headstage. Headstage A/D converter and transmitter Digital Wireless Transmission Receiver Microprocessor Interface Board Connection computer Software Data visualization and analysis Aumatically when spping data acquisition Switching via control software quickly and a data compresssion is included. This guarantees an excellent signal-noise ratio which is independent Any PC or lapp can be used from the distance between sender and receiver. Active Recording Stand-By Switched Off Low battery Marginal battery In combination with a long transmission Aumatically when starting data acquisition range, the digital data transmission permits flexible long-term experiments Switching via infrared flashlight, included in the system in large environments. and optical MCS uniquely provides headstages for optical and electrical. You do not need give up valuable recording information while stimulating; the headstages allow you Analog output any data acquistion Various possibilities for battery placement and electrode connections record and stimulate simultaneously! The headstage for optical offers an interface For maximum flexibility, we offer headstages with 2 LEDs. So in addition 4 recording channels, you connections any type of probes. Just let us know Generally, the Wireless-Systems are com- can program 2 patterns for the connected plete work stations with data acquisition LEDs. Parallel experiments The headstage for electrical has 2 dedicated The Wireless-System offers the possibility channels with current output in addition either 8 or 14 recording channels. simultaneously and software from Multi Channel Systems. However, you have the option add an analog output of all channels. as well as electrical patterns can be You can then connect your existing data designed freely via the included software Multi Channel acquisition and analyze the data in your Experimenter. software. This gives you the flexibility integrate the MCS-Wireless-System in your existing set-up and use the peripheral equipment you are familiar with - while adding valuable, undisturbed in vivo data. record from up which probe you want use and we will provide the eight one setup animals corresponding connecr. Moreover, depending on your experiment, you can also a decide where position the battery of the headstage. reduced sampling rate). Up four receivers Either fix it on the headstage itself or use a special backpack can be run in parallel in the same room, for the cable-connected battery. Independent of your with a tal number of 16 headstages. decision, be sure that the battery is small and lightweight in with (at order not influence your experiment.

Energy-efficiency and flexibility Key advantage: Digital data transmission The Wireless-System converts Versatile software: Multi Channel Suite All devices of the Wireless-Systems are designed be recording continues, the headstage switches on The Wireless-System comes with the powerful and easy--use software package Multi energy-efficient. The standard battery of the headstage aumatically. Another possibility is turn off the Channel Suite. It consists of three programs and updates are available for free from converter and LED lights for video, permits continuous recording of all channels for approx. headstage completely via the data acquisition software. the MCS website. Systems is the all-in-one solution for digitized transmission, powerful receiver, 2 hours (details on back side). Recharging is then For switching on without any interference, just use the amplifying, recording, and analyzing in vivo interface board, and data acquisition Multi Channel Experimenter for data acquisition and online analysis. With an easy- realized via a USB charger. included infrared flashlight which does not disturb the data from 4, 8, 16 or 32 channels. software package. -use drag n drop interface, you simply create your virtual experiment adding e.g. For recording in animals insensitive weight, we also animal. data source, filters, spike detection, and recorder. Battery level and signal quality are The bandwidth is 1 Hz 5 khz, With its excellent signal--noise ratio, offer larger batteries, which provide longer recording Single channels can always be switched on and off for indicated here and your data is displayed in real-time. Modular setup of headstages sampled at up 40 khz per channel it is the ideal solution for recording times. Please contact Multi Channel Systems for more recording via software. This allows you adjust energy Multi Channel Analyzer for offline analysis. You just import the recorded data and The wireless headstages are built accord- simultaneously. With a resolution of 16 bit, spikes, LFP, EEG, ECG, EMG, and ECoG. information on battery options. and sampling rate whenever you like. define your in-depth analysis with additional instruments. The Multi Channel Analyzer ing your needs. The level-based con- the accuracy of your data is guaranteed. Additional inputs the interface board also supports synchronized video input for behavioral research with freely moving struction makes cusm-built headstages The systems include everything you need: allow the synchronization of your data with For power-saving, the headstage switches stand-by possible. Your headstage can consist of Small-sized headstage with integrated A/D external devices. mode as soon as the data acquisition is spped. When animals. Both, the video data and electrophysiological recordings are displayed in parallel and you can easily skip through the data from one event the next. levels for amplification and A/D conver- Multi Channel DataManager for data export for further analysis with third- sion, electrical or optical, party programs. Data files are exported in HDF5 (e.g. Matlab, Python),.nex motion sensors and many more which (Neuroexplorer) or.ced (Spike 2). Independent of the file format, the export is done are currently under development. Wireless recording system The Wireless-System from Multi Channel the recorded signals in digital data already on the headstage. Headstage A/D converter and transmitter Digital Wireless Transmission Receiver Microprocessor Interface Board Connection computer Software Data visualization and analysis Aumatically when spping data acquisition Switching via control software quickly and a data compresssion is included. This guarantees an excellent signal-noise ratio which is independent Any PC or lapp can be used from the distance between sender and receiver. Active Recording Stand-By Switched Off Low battery Marginal battery In combination with a long transmission Aumatically when starting data acquisition range, the digital data transmission permits flexible long-term experiments Switching via infrared flashlight, included in the system in large environments. and optical MCS uniquely provides headstages for optical and electrical. You do not need give up valuable recording information while stimulating; the headstages allow you Analog output any data acquistion Various possibilities for battery placement and electrode connections record and stimulate simultaneously! The headstage for optical offers an interface For maximum flexibility, we offer headstages with 2 LEDs. So in addition 4 recording channels, you connections any type of probes. Just let us know Generally, the Wireless-Systems are com- can program 2 patterns for the connected plete work stations with data acquisition LEDs. Parallel experiments The headstage for electrical has 2 dedicated The Wireless-System offers the possibility channels with current output in addition either 8 or 14 recording channels. simultaneously and software from Multi Channel Systems. However, you have the option add an analog output of all channels. as well as electrical patterns can be You can then connect your existing data designed freely via the included software Multi Channel acquisition and analyze the data in your Experimenter. software. This gives you the flexibility integrate the MCS-Wireless-System in your existing set-up and use the peripheral equipment you are familiar with - while adding valuable, undisturbed in vivo data. record from up which probe you want use and we will provide the eight one setup animals corresponding connecr. Moreover, depending on your experiment, you can also a decide where position the battery of the headstage. reduced sampling rate). Up four receivers Either fix it on the headstage itself or use a special backpack can be run in parallel in the same room, for the cable-connected battery. Independent of your with a tal number of 16 headstages. decision, be sure that the battery is small and lightweight in with (at order not influence your experiment.

Wireless-Systems: Technical specifications Number of channels 4, 8, 16 or 32 Dimensions (W x D x H) (Width w/o antennas; height w/o battery) Type of headstage W2100-HS4 W2100-HS8 W2100-HS16 W2100-HS32 W2100-HS4-op W2100-HS8-ES2 W2100-HS14-ES2 W2100-HS-EEG/EMG/Temp Dimension 13 x 13 x 5.5 mm 15.5 x 15.5 x 6.7 mm 13 x 13 x 5.5 mm Weight (Headstage without battery) Type of headstage W2100-HS4 W2100-HS8 W2100-HS16 W2100-HS32 W2100-HS4-op W2100-HS8-ES2 W2100-HS14-ES2 W2100-HS-EEG/EMG/Temp Weight of headstage 1.9 g 2.8 g (OM), 3.1 g (SR) 2.9 g 3.7 g 1.9 g 3.7 g 3.7 g 3.0 g Battery Battery types and approx. weights (Standard batteries, other capacities available on request) Battery life (until recharge) Resolution Input voltage range Sampling rate (khz per channel) Lithium-Polymer, rechargeable Capacity e.g. 32 channels with 100 mah battery: approx. 1 hour 16 bit ± 12.4 mv Sampling rate (khz/ch) Type of headstage Weight of battery (cable or battery board) 30 mah 1.5 g; 1.5 g 100 mah (standard) 3.7 g; 3.8 g 200 mah 5.1 g; 6.7 g 300 mah 8.1 g; 8.7 g Number of selected channels 2 4 8 16 32 W2100-HS4 40 32 - - - W2100-HS8 40 40 25 - - W2100-HS16 40 40 25 25 - W2100-HS32 40 40 25 25 20 W2100-HS4-op 10 10 Bandwidth Distance for wireless link 1 Hz 5 khz (0.1 Hz on request) 5 m guaranteed (under normal lab conditions) Control interface USB 3.0 Software: Operating system Multi Channel Suite Windows 7 or 8 (English and German versions supported) Version 1.5.0 and higher

Distributed by: Multi Channel Systems MCS GmbH February 2016 Multi Channel Systems MCS GmbH Product information is subject change without notice. Products that are referred in this document may be either trademarks and/or registered trademarks of the respective owners. The publisher and the author make no claim these trademarks. Aspenhaustraße 21 72770 Reutlingen Germany Fon +49-7121-9 09 25 25 Fax +49-7121-9 09 25 11 sales@multichannelsystems.com www.multichannelsystems.com