Electroencephalograph EEG-1200J/K

Similar documents
Electroencephalograph EEG-1200J/K

Neural Function Measuring System MEE-1000A 16/32 ch. Intraoperative Monitoring System

EEG-1200K Electrocephalograph

Neural Function Measuring System MEE /32 ch Intraoperative Monitoring System

SigCal32 User s Guide Version 3.0

ECG HOLTER INtUItIVe USeR INteRFAce Interactive Graphs Interactive Histograms navigation by extremes Fully Customizable R E LT O H CG E

SigCalRP User s Guide

from signals to sources asa-lab turnkey solution for ERP research

Panorama TELEPACK 608

Evaluation of exposure to pulsed magnetic fields by examining the variations in the spectrum and over time with ELT-400

The all-in-one solution for wireless recording and stimulating in vivo

//cerebro. //fall_16

S240. Real Time Spectrum Analysis Software Application. Product Brochure

Electroencephalograph-recorder Encephalan-EEGR-19/26 portable

Section 10: Radio Frequency Communication

PRODUCT DATA. PULSE Multichannel Sound Power Type 7748 Version 1.2

Product description: sp_walk400h_cardiolinespa_07_eng1.doc 1/2

NEUROLOGY. MEB-9400 EMG/EP measurement system Product Features & Technical Data

EC209 - Improving Signal-To-Noise Ratio (SNR) for Optimizing Repeatable Auditory Brainstem Responses

Selective and broadband high frequency field analysis

EG medlab. Three Lead ECG OEM board. Version Technical Manual. Medlab GmbH Three Lead ECG OEM Module EG01010 User Manual

Chroma. Optical Spectral Analysis and Color Measurement

TSA 6000 System Features Summary

Electroencephalograph-recorder Encephalan-EEGR-19/26

Request or Schedule an Appointment Health Link

Submittals Quick Reference Guide

Frequency and Time Domain Representation of Sinusoidal Signals

m+p Analyzer Revision 5.2

Agilent U8903A Audio Analyzer

Experiment 15: Diode Lab Part 1

Basic Tutorial of Circuit Maker

Laboratory Experiment #1 Introduction to Spectral Analysis

PHYC 500: Introduction to LabView. Exercise 9 (v 1.1) Spectral content of waveforms. M.P. Hasselbeck, University of New Mexico

TCM4 Series. Product line for transcutaneous monitoring

LAB #7: Digital Signal Processing

EndpointWorks. Plasma-Therm LLC

Analysis and simulation of EEG Brain Signal Data using MATLAB

BRAIN COMPUTER INTERFACE (BCI) RESEARCH CENTER AT SRM UNIVERSITY

PSM1000. In-Ear Personal Monitoring Systems. PSM1000 In-Ear Personal Systems THE SOUND OF CONFIDENCE.

Technological Advances in General Lighting. New Lightmeter for Solid State Lighting. State-of-the-Art LED Illuminance Meter

VIBXPERT. 2-Channel Vibration Analyzer. 102,400 lines of resolution. Weighs only 2.2 lbs. Simple joystick operation. Signal post processing

Experiment P36: Resonance Modes and the Speed of Sound (Voltage Sensor, Power Amplifier)

4.0 How to Turn On the Selenia Dimensions

RF Measurements You Didn't Know Your Oscilloscope Could Make

9/2/2013 Excellent ID. Operational Manual eskan SADL handheld scanner

DI-2108 USB Data Acquisition (DAQ) System

The new generation More comfortable even faster more precise SmartBalancer2 Perfect field balancing made easy

Copyright 2014 SOTA Imaging. All rights reserved. The CLIOSOFT software includes the following parts copyrighted by other parties:

NDT Supply.com 7952 Nieman Road Lenexa, KS USA

Top-Innovator EncoderAnalyzer. For testing encoders. Made in Germany Expect more. Winding testers

Analysis of static and time-variable magnetic fields

USB Multifunction Arbitrary Waveform Generator AWG2300. User Guide

ZONESCAN net Version 1.4.0

NEWS RELEASE IMEC REPORTS TWO WIRELESS PLATFORMS FOR BIOMEDICAL MONITORING

Crestron CLS-C6 Series ilux Integrated Lighting System User Guide

Faculty of Information Engineering & Technology. The Communications Department. Course: Advanced Communication Lab [COMM 1005] Lab 6.

LA-T LED ANALYSER EVALUATION KIT INSTRUCTION MANUAL. rev

APPENDIX E: IWX214 HARDWARE MANUAL

Take Control. Introduction. Control Principles

P08050 Remote EEG Sensing

EEL 4350 Principles of Communication Project 2 Due Tuesday, February 10 at the Beginning of Class

CHAPTER 7 INTERFERENCE CANCELLATION IN EMG SIGNAL

Continuously monitors and stores the levels of Electromagnetic fields Up to four simultaneous bands: GSM 900 / 1800 MHz / UMTS / Broadband 100 khz 3

Data Acquisition and Processing of a Distributed 3D Induced Polarisation Imaging system

RF NiceRF Wireless Technology Co., Ltd. Rev

Advanced Lab LAB 6: Signal Acquisition & Spectrum Analysis Using VirtualBench DSA Equipment: Objectives:

Audio Analyzer R&S UPV. Up to the limits

Nikon View DX for Macintosh

Guide to OPKUD and OPBOX Ultrasonic testing units Software Revision 3.0 / 2003

innovative technology to keep you a step ahead

Catalog

Advanced Test Equipment Rentals ATEC (2832)

ENSC327 Communication Systems Fall 2011 Assignment #1 Due Wednesday, Sept. 28, 4:00 pm

ZONESCAN net Version 1.4.1

VNS Therapy System Overview and Dosing

R&S NRPM Over-the-Air (OTA) Power Measurement Solution For 5G, WLAN IEEE ad and IEEE ay

Reference. TDS6000 Series Digital Storage Oscilloscopes

The Flash IIP Console is the heart of every FCR system. It s designed to maximize productivity in the busiest environments.

BME 405 BIOMEDICAL ENGINEERING SENIOR DESIGN 1 Fall 2005 BME Design Mini-Project Project Title

GDS BEAT FAQ. The GDS Bender Element Analysis Tool Frequently Asked Questions. GDS BEAT FAQ v1.2

D500. Defibrillator/Monitor NIBP. Temperature 1. Temperature 2 IBP 1 IBP 2. Capnography. Integrated Thermal Printer LCD

Understanding Digital Photography

m+p VibControl Sine Vibration Control

D372A Electroluminescent Lamp Driver IC

Intelligent and Flexible Monitor Circuits Detect & Record Load Profiles and Fault Events All Distribution Voltages All Conductor Types

Stepping Motor Station

Experiment P48: Transistor Lab 1 The NPN Transistor as a Digital Switch (Power Amplifier, Voltage Sensor)

K-DT1 Portable Radar Doppler Target User Manual

KODAK Dental Imaging Software. Quick Start Guide

EECS 307: Lab Handout 2 (FALL 2012)

PRODUCT SHEET. fnir 2000C Imager fnir2000s Imager fnir2000p Imager

LabVIEW Basics Peter Avitabile,Jeffrey Hodgkins Mechanical Engineering Department University of Massachusetts Lowell

Objectives. Abstract. This PRO Lesson will examine the Fast Fourier Transformation (FFT) as follows:

Product Introduction ML8720C. Area Tester ML8740B. Area Scanner

A Finite Impulse Response (FIR) Filtering Technique for Enhancement of Electroencephalographic (EEG) Signal

Helping you improve patient care. Welch Allyn Holter Systems

Using Wavemaker: A Guide to Creating Arbitrary Waveforms for Syscomp CircuitGear and Waveform Generators

New Features Guide. Version 3.00

TM1600. Circuit Breaker Analyzer System

Optimizing future wireless communication systems

Transcription:

Electroencephalograph EEG-1200J/K

EEG-1200 User-friendly Efficient Expandable Accurate

The possibilities are endless.

User-friendly Customizable new main menu You can register up to 10 examination protocol buttons per page on the main menu. Each button has user-defined settings for an examination. The settings can also be changed for different examination conditions. 3D Voltage mapping Fast review and advanced EEG analysis Whole head maps provide a complete overview and a better interpretation of the topography of EEG abnormalities. Just click on a detected pattern to obtain 3D maps of the whole head. Click on a particular view to obtain a series of maps showing the change over time. Note window Simple copying of waveform parts You can save up to 1000 sections of waveforms for comparison by dragging and dropping. Up to 100 copied waveforms can be registered as sample data for comparison with other patients. Zoom window You can easily magnify the waveforms by dragging them. Amplitude and latency of magnified waveforms can be measured and printed. Screen comment tags Up to 100 tags can be attached to an EEG file for later reference or messages to the reviewer. The tags can include Word documents, Excel spreadsheets, images and other files. DSA trendgraph Frequency components of EEG and the amplitudes of each frequency are displayed as a DSA (Density Spectral Array) trend graph on the review screen and EEG Scope. The DSA lets you find epileptic seizures of a specific EEG frequency band over a long period of time at a glance.

Efficient EEG Scope Data review during acquisition Comparison Mode: The EEG Scope function lets you look back into and review previous epochs of EEG while simultaneously monitoring current EEG acquisition. One side of a split screen shows previous EEG epochs and the other side shows the current EEG. Advanced EEG report generation Using NeuroReport (standard) NeuroReport has various item templates for reports and you can create customized reports for different examination types, physicians or other criteria. You can also create an EMU examination report which has screen comments automatically assigned to seizure events. Reports are saved in a database and you can quickly search for reports by patient information, measurement values and other criteria. Junction box: JE-921A All-in-one solution: One junction box for routine EEG and PSG. This advanced junction box integrates 32 channel EEG input and SpO 2 /CO 2 inputs. JE-921A provides the highest signal quality and maximum reliability. Extra PSG sensor capability Input jacks for analog signals from external instruments such as CPAP Unique technology Built-in SpO 2 /CO 2 inputs 4 channels DC input

Expandable A variety of electrode junction boxes Nihon Kohden introduced the world s first 192 channel system. You can also choose 64 or 128 channel electrode junction boxes for surface, subdural and depth electrodes. A 10-10 system electrode junction box and smaller, mini flat junction boxes are also available to enhance the patient s comfort. The JE-207A, JE-209A, and JE-212A electrode junction boxes have a high sampling rate up to 10 khz. 192 channels JE-212A junction box with JE-213A and two JE-214A mini junction boxes 128 channels JE-209A junction box with JE-213A and JE-214A mini junction boxes 128 channels JE-209A junction box with JE-210A mini junction box 64 channels JE-207A junction box with JE-213A mini junction box 64 channels JE-207A junction box with JE-208A mini junction box EEG input over a LAN network The QI-122A input box converter connects any junction box to the EEG over a LAN network. This provides LAN connectivity and expandability for an EEG system in the EMU. Wireless Input Unit: WEE-1000K Up to 64 channels EEG, ECG, EMG, Resp, SpO 2 data can be sent to the EEG unit by wireless transmission. Data can be transmitted up to 100 m without walls 24 hours battery life (32 channel) / 18 hours battery life (64 channel) One junction box for EEG and PSG SpO 2 interface Seamless recording 60 min continuous backup of EEG data when a patient temporarily moves out of the wireless range Digital video recording is available with a QV-101AK digital video unit

Accurate Digital video software: Video-link QP-110AK Synchronized digital video for EEG systems Patient images synchronized with the EEG waveforms can be recorded The EEG waveforms and patient images can be saved to a hard drive Video clip and snapshot functions are available Spike detector software: Spike Detector QP-251AK On-line and off-line spike and seizure detection vastly improved with greater accuracy Group spikes with hierarchical clustering Detailed topographic and morphologic distribution of selected group Spatial propagation of a spike over time Compare left and right hemisphere discharges with side by side traces Audible or visual notification of spike detection * Product of Persys Development Corporation EEG mapping software: QP-220AK Real-time and basic EEG mapping software Real-time and off-line mapping Up to eight frequency maps (seven power/voltage maps at seven different frequency bands and one map of all frequency bands) Power/Voltage spectra for up to 32 channels of EEG waveform data Edge frequency, average frequency, median frequency or peak frequency for each spectrum is indicated with a mark Analysis software: EEGFocus QP-211AK and MULTIVIEW QP-214AK Review, mapping, remontaging, filtering and FFT Voltage and current source density mapping Automatic rejection of eye blink artifact without modifying the original data Automatic detection and averaging of similar waves Source imaging (available with EEGFocus) EEG examination support software: QP-150AK Seizure detection and review Voltage mapping and waveform view EEG TrendScope Sleep analysis software: Polysmith QP-260AK Display, store and analyze sleep data Reformatting of individual channel filters and sensitivities or montage Customize the system to best suit your needs Time-link trendgraphs superimposed on waveform data with epoch details

Composit ion e xamples Routine EEG composition Electroencephalograph PC unit Electrode junction box Flash lamp assembly Photic stimulator control unit Cart Stand LCD display EEG-1200J/K CC-120AJ/AK JE-921A LS-703A LS-120AJ/AK KE-122A KC-001A local purchase EMU composition Electroencephalograph EEG-1200J/K PC unit CC-120AJ/AK Input box converter QI-122A/AK 192 channel electrode junction box JE-212A Mini junction box JE-213A Mini junction box JE-214A Flash lamp assembly LS-703A Photic stimulator control unit LS-120AJ/AK Cart with printer table KD-029A Stand KC-001A LCD pole for dual display KH-122A LCD display local purchase Model Suffixes EEG-1200 has the following suffixies: J: 110-127 V AC operation K: 220-240 V AC operation EEGFocus is an original technology of MEGIS Software GmbH. Polysmith is a trademark of Neurotronics Inc. Windows and the Windows logo are registered trademarks of Microsoft Corporation. This brochure may be revised or replaced by Nihon Kohden at any time without notice. 5300 CAT.No.57-020 09.03. SZ. E Printed in Japan on FSC certified paper