International Journal of Engineering Research-Online A Peer Reviewed International Journal Articles available online

Similar documents
DC-Voltage fluctuation elimination through a dc-capacitor current control for PMSG under unbalanced grid voltage conditions

DC BUS VOLTAGE CONTROL OF PWM CONVERTERS IN PMSG IN WIND POWER SYSTEM Krishnamoorthy.M 1 Andal. S 2 M.Varatharaj 3

Extraction of Extreme Power and Standardize of Voltage and Frequency under Varying Wind Conditions

Voltage stability enhancement using an adaptive hysteresis controlled variable speed wind turbine driven EESG with MPPT

Tracking of Maximum Power from Wind Using Fuzzy Logic Controller Based On PMSG

GRID CONNECTED HYBRID SYSTEM WITH SEPIC CONVERTER AND INVERTER FOR POWER QUALITY COMPENSATION

ADVANCED CONTROL TECHNIQUES IN VARIABLE SPEED STAND ALONE WIND TURBINE SYSTEM

Pak. J. Biotechnol. Vol. 13 (special issue on Innovations in information Embedded and communication Systems) Pp (2016)

Design and Development of MPPT for Wind Electrical Power System under Variable Speed Generation Using Fuzzy Logic

STATCOM with FLC and Pi Controller for a Three-Phase SEIG Feeding Single-Phase Loads

A Fuzzy Controlled PWM Current Source Inverter for Wind Energy Conversion System

P. Sivakumar* 1 and V. Rajasekaran 2

*K.Rama Lingeswara Prasad1, *Dr.K.Chandra Sekhar2

Simulation of Solar Powered PMBLDC Motor Drive

ROBUST ANALYSIS OF PID CONTROLLED INVERTER SYSTEM FOR GRID INTERCONNECTED VARIABLE SPEED WIND GENERATOR

Voltage Regulated Five Level Inverter Fed Wind Energy Conversion System using PMSG

CONTROL SCHEME OF STAND-ALONE WIND POWER SUPPLY SYSTEM WITH BATTERY ENERGY STORAGE SYSTEM

POWER ISIPO 29 ISIPO 27

Analysis of Hybrid Renewable Energy System using NPC Inverter

New Direct Torque Control of DFIG under Balanced and Unbalanced Grid Voltage

Improved Transient Compensation Using PI-SRF Control Scheme Based UHVDC For Offshore Wind Power Plant

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Impact Factor: Student, SV University, Tirupati, India.

Modeling & Simulation of Permanent Magnet Synchronous Wind Generator Based Stand-alone System

B.Tech Academic Projects EEE (Simulation)

Grid Interconnection of Wind Energy System at Distribution Level Using Intelligence Controller

Application of Fuzzy Logic Controller in Shunt Active Power Filter

Power Quality Improvement of Distribution Network for Non-Linear Loads using Inductive Active Filtering Method Suresh Reddy D 1 Chidananda G Yajaman 2

Fuzzy Logic Based MPPT for Wind Energy System with Power Factor Correction

A Pv Fed Buck Boost Converter Combining Ky And Buck Converter With Feedback

Maximum Power Extraction from A Small Wind Turbine Using 4-phase Interleaved Boost Converter

FUZZY LOGIC CONTROLLER BASED UPQC FOR POWER QUALITY MITIGATION IN GRID CONNECTED WIND ENERGY CONVERSION SYSTEM

Analysis of Hybrid Renewable Energy System using NPC Inverter

System for Better Synchronism in DFIG Wind Energy Conversion System Using SMES Energy Storage

ANALYSIS OF GRID SYNCHRONISATION UNDER BALANCED AND UNBALANCED FAULTS USING PLL TECHNIQUES

Voltage Control Of Three Phase Ac/Dc Pwm Converters Using Feedback Linearisation

CURRENT FOLLOWER APPROACH BASED PI AND FUZZY LOGIC CONTROLLERS FOR BLDC MOTOR DRIVE SYSTEM FED FROM CUK CONVERTER

Harmonics Reduction in a Wind Energy Conversion System with a Permanent Magnet Synchronous Generator

Improvement of Power Quality Using Hybrid Active Power Filter in Three- Phase Three- Wire System Applied to Induction Drive

Control of grid connected inverter system for sinusoidal current injection with improved performance

Direct AC/AC power converter for wind power application

IJCSIET--International Journal of Computer Science information and Engg., Technologies ISSN

Optimal Operation of Low Cost Topology for Improving the Power Quality in the Wind Power Conversion System

IMPROVED SYNCHRONISM IN DFIG WIND ENERGY CONVERSION SYSTEM USING SMES ENERGY STORAGE

Power Quality Improvement of Grid Connected Wind Energy System by Statcom for Balanced and Unbalanced Linear and Nonlinear Loads

Sepic Topology Based High Step-Up Step down Soft Switching Bidirectional DC-DC Converter for Energy Storage Applications

Harnessing of wind power in the present era system

PI-VPI Based Current Control Strategy to Improve the Performance of Shunt Active Power Filter

LOW VOLTAGE RIDE - THROUGH CAPABILITY OF WIND FARMS

Self-Excitation and Voltage Control of an Induction Generator in an Independent Wind Energy Conversion System

Investigation of D-Statcom Operation in Electric Distribution System

IMPROVING EFFICIENCY OF ACTIVE POWER FILTER FOR RENEWABLE POWER GENERATION SYSTEMS BY USING PREDICTIVE CONTROL METHOD AND FUZZY LOGIC CONTROL METHOD

ANALYSIS OF POWER QUALITY IMPROVEMENT OF BLDC MOTOR DRIVE USING CUK CONVERTER OPERATING IN DISCONTINUOUS CONDUCTION MODE

Stability of Voltage using Different Control strategies In Isolated Self Excited Induction Generator for Variable Speed Applications

MPPT for PMSG Based Standalone Wind Energy Conversion System (WECS)

Design of Single-Stage Transformer less Grid Connected Photovoltaic System

MODELING AND ANALYSIS OF IMPEDANCE NETWORK VOLTAGE SOURCE CONVERTER FED TO INDUSTRIAL DRIVES

SIMULATION OF MPPT TECHNIQUE USING BOOST CONVERTER FOR WIND ENERGY CONVERSION SYSTEM

Three Phase PFC and Harmonic Mitigation Using Buck Boost Converter Topology

Aalborg Universitet. Design and Control of A DC Grid for Offshore Wind Farms Deng, Fujin. Publication date: 2012

THD Reduction in PMSG Based Wind Energy System Using 17 Level Modular Multilevel Converter

AC and DC fault ride through hybrid MMC integrating wind power

Laboratory Investigation of Variable Speed Control of Synchronous Generator With a Boost Converter for Wind Turbine Applications

CHAPTER 6 UNIT VECTOR GENERATION FOR DETECTING VOLTAGE ANGLE

MMC based D-STATCOM for Different Loading Conditions

PERFORMANCE ANALYSIS OF SVPWM AND FUZZY CONTROLLED HYBRID ACTIVE POWER FILTER

Performance Evaluation of PWM Converter Control Strategy for PMSG Based Variable Speed Wind Turbine

A NEW C-DUMP CONVERTER WITH POWER FACTOR CORRECTION FEATURE FOR BLDC DRIVE

Application of Matrix Converter in Wind Energy Conventional System Employing PMSG

Modeling and Simulation of Wind Farm with STATCOM in PSCAD/EMTDC Environment

M.Tech in Industrial Electronics, SJCE, Mysore, 2 Associate Professor, Dept. of ECE, SJCE, Mysore

A Novel Fuzzy Control Approach for Modified C- Dump Converter Based BLDC Machine Used In Flywheel Energy Storage System

UNIFIED POWER QUALITY CONDITIONER IN DISTRIBUTION SYSTEM FOR ENHANCING POWER QUALITY

Power Quality Improvement in Wind Energy Conversion System of Grid Interfacing Inverter using Hysteresis Band Current Controller

CHAPTER 6 ANALYSIS OF THREE PHASE HYBRID SCHEME WITH VIENNA RECTIFIER USING PV ARRAY AND WIND DRIVEN INDUCTION GENERATORS

Available online at ScienceDirect. Procedia Technology 21 (2015 ) SMART GRID Technologies, August 6-8, 2015

Development of an Experimental Rig for Doubly-Fed Induction Generator based Wind Turbine

Feed-Forward System Control for Solid- State Transformer in DFIG

Development of DC-AC Link Converter for Wind Generator

Multilevel Inverter Based Statcom For Power System Load Balancing System

Chhattisgarh Swami Vivekanand Technical University, Bhilai

Cascaded H-Bridge Five Level Inverter for Harmonics Mitigation and Reactive Power Control

A Modified Control Method For A Dual Unified Power Quality Conditioner

DESIGN OF A MODE DECOUPLING FOR VOLTAGE CONTROL OF WIND-DRIVEN IG SYSTEM

A Five Level Inverter for Grid Connected PV System Employing Fuzzy Controller

Modular Grid Connected Photovoltaic System with New Multilevel Inverter

A New Control Strategy for Three- Phase Inverter Applied To Induction Motor of Micro Grid

Adaptive ANN based STATCOM and DVR for optimal integration of wind energy with grid using permanent magnet synchronous generator

SINGLE PHASE BRIDGELESS PFC FOR PI CONTROLLED THREE PHASE INDUCTION MOTOR DRIVE

Modeling of Single Stage Grid-Connected Buck-Boost Inverter for Domestic Applications Maruthi Banakar 1 Mrs. Ramya N 2

Power Quality Improvement Wind/PV Hybrid System by using Facts Device

Usha Nandhini.M #1, Kaliappan.S *2, Dr. R. Rajeswari #3 #1 PG Scholar, Department of EEE, Kumaraguru College of Technology, Coimbatore, India

CONVERTERS IN POWER VOLTAGE-SOURCED SYSTEMS. Modeling, Control, and Applications IEEE UNIVERSITATSBIBLIOTHEK HANNOVER. Amirnaser Yazdani.

International Journal of Engineering Research and General Science Volume 5, Issue 2, March-April, 2017 ISSN

Masterthesis. Variable Speed Wind Turbine equipped with a Synchronous Generator. by Christian Freitag

SVPWM Buck-Boost VSI

Compensation of Unbalanced Sags/Swells by Single Phase Dynamic Voltage Restorer

ABSTRACT I. INTRODUCTION

FUZZY MPPT CONTROLLER FOR SMALL SCALE STAND ALONE PMSG WIND TURBINE

INSTANTANEOUS POWER CONTROL OF D-STATCOM FOR ENHANCEMENT OF THE STEADY-STATE PERFORMANCE

714 IEEE TRANSACTIONS ON ENERGY CONVERSION, VOL. 24, NO. 3, SEPTEMBER 2009

Transcription:

RESEARCH ARTICLE ISSN: 2321-7758 FUZZY LOGIC BASED PMSG WIND TURBINE SYSTEM WITH FAULT RIDE THROUGH TECHNIQUE K.SEETHA DEVI, 1* P.SELVARAJ, 2 J.BASKARAN 3 1 P.G Scholar, Adhiparasakthi engineering college, Melmaruvathur-603 319. 2 Assistant professor/eee, Adhiparasakthi engineering college, Melmaruvathur-603 319. 3 HOD/EEE, Adhiparasakthi engineering college, Melmaruvathur-603 319. Article Received: 22/01/2015 Article Revised on: 31/01/2015 Article Accepted on:05/02/2015 ABSTRACT K.SEETHA DEVI P. SELVARAJ This paper presents the PMSG-based wind turbine system configuration that includes not only an auxiliary converter to control ESS but also a coordinated control strategy that enhance the low voltage ride through capability to improve power quality. During normal operation, the line-side converter maintains the DC-link voltage constant. But during grid faults, a hierarchical coordinated control scheme works that includes line-side converter injecting reactive current into grid, energy storage system and braking chopper to control DC link voltage depending on the grid voltage sags. The feasibility and the effectiveness of the proposed system topology and hierarchical coordinated control strategy were verified using MATLAB/Simulink. Key Words - braking chopper (BC), energy storage system (ESS), fault ride through (FRT), generator side converter (GSC), line side converter (LSC),permanent magnet synchronous generator (PMSG), point of common coupling (PCC), low voltage ride through (LVRT), wind turbine (WT), Wind energy conversion system (WECS). KY Publications Dr.J.BASKARAN INTRODUCTION Among various renewable energy sources, the wind energy power generation has been concerned as one of the most rapidly growing energy source because of pollution free resource which has inexhaustible potential and also cost advantage over others. The main concern of wind is its irregularity in occurrence and so as to maximize the energy generated from wind turbine with better quality [1],[2]. When the wind power station is integrated to power grid, power quality issue arises like injection of harmonic, poor power factor and distortion from pure sine wave. One of the series issue for the operation is low voltage ride through capability to which the turbine are expected to comply with the requirement of grid code. Fig.1 [3] 117 K.SEETHA DEVI et al

(a) (b) 100 80 60 40 20 0 I r (%) 90 0 V (%) No trip 0.15 0.5 1 15 Fault operration May trip 60 85 Normal operation Time(s) V (%) Fig. 1. Denmark grid code (a) Low voltage ride through requirement. (b) Reactive current requirement. Wind energy conversion system (WECS) uses pitch angle control, drive train, generator and power converter to produce output power[4]. Variable speed wind turbine generator is used instead of fixed speed wind turbine which helps to increase the energy capture through maximum power point technique. Thereby, increasing efficiency and power quality of output power. The efficiency of variable speed wind turbine system improved significantly by using direct drive system [4].Direct drive wind energy conversion system use PMSG system which has lot of advantage over DFIG such as no gear box, high power density and simple control method except initial cost [4]. The threat to grid stability is controlled by pitch control and DC link voltage control, which results in low cost WECS and stable operation during fault [5] [6]. Wind turbine is protected from over speed and excess power through yaw scheme [7]. But, the energy captured is not optimum. WECS supplemented with energy storage system [8]. The system is proposed by electrolytic capacitor[9] which is replaced with reduced stage of energy conversion [10]. An LVRT strategy is proposed for variable speed PMSG wind turbine system using the method of dc link voltage control and feedback linearization theory [11]. Generator side converter is used for analysis instead of gride side converter using the MPPT strategy [12].Reactive power compensation by STATCOM and SVC on the transient stability limit is analysed with LVRT capability of an induction generator that estimates the required rating of different compensation devices after a fault which produces a result that STATCOM is efficient then SVC [13]. PI AND FUZZY LOGIC CONTROLLER WIND PMSG FILTER GRID AC DC C BC DC AC WIND TURBINE GSC CUK CONVERTER LSC L DC DC EDLC FUZZY LOGIC CONTROLLER Fig.2. Configuration of PMSG wind turbine system consisting of ESS and BC 118 K.SEETHA DEVI et al

SYSTEM CONFIGUGRATION In this paper, the variable speed wind turbine with full scale frequency converter is used for research on distributed power generation systems as shown in Fig 2. LSC controls the DC-link voltage constant. GSC controls the torque and the speed of WT. The two converters are connected by a DC link capacitor in order to have a separate control for each converter. This aspect requires additional infrastructure to convey the generated power with better power quality to the demand centres. Therefore fault ride through (FRT) technique is proposed for the system. By using the control mode during fault period, the ESS control the DC link, BC is used to smoothen the output voltage by dissipating the extra power and the LSC act as STATCOM by feeding reactive power into the grid. To have an efficient and a reliable control, the system is used with CUK converter, fuzzy logic controller and PI controller. MODELLING OF WIND TURBINE Wind turbine is a device that converts kinetic energy into electrical energy. The kinetic energy is obtained by the blade from the wind which is transformed into mechanical energy. The wind turbine cannot extract full energy from wind. The wind turbine s output power is given by, (1) level), R = Blade radius (in m), (it varies between 40-60 m),v w = Wind velocity (m/s) (velocity can be controlled between 3 to 30 m/s),c p =The power coefficient which is a function of both tip speed ratio (λ), and blade pitch angle (ߺ) (2) The common AC generator used for wind turbine are field excitation induction generator (FEIG), squirrel cage induction generator (SCIG), doubly fed induction generator (DFIG), permanent magnet synchronous generator (PMSG). The use of PMSG in WT shown in Fig 3, increased due to no field excitation loss, smaller physical size, low maintenance and use of power electronics converter with full rating. Therefore PMSG for WT is efficient then other generator [12]. CONTROL OF BACK-BACK CONVERTER A. GSC Control: GSC act as rectifier. Rectifiers are electronic devices which convert AC into DC through PI and fuzzy logic controller. IGBT switch bridge circuit works as a six pulse rectifier. Converting the variable frequency/variable amplitude AC output voltage of the generator to a DC voltage of a variable level, the WT generator can be operated at different speeds and frequencies other than its fixed synchronous speed. P w = Extracted power from the wind, ρ = Air density, (approximately 1.2 kg/m 3 at at sea Fig.3. PMSG in wind turbine. 119 K.SEETHA DEVI et al

Fig.4. Switch connection for generator side converter GSC is used to control the torque or speed of the wind turbine. The GSC performs vector control in which the fuzzy logic and PI controller combine to control the inner current control loop and outer speed control loop shown in Fig 4. The reference speed is commutated by multiplying the previous value by a constant k, in which the constant k depends on the system inertia constant (H s ) and the sampling period of the speed controller (T). The new speed reference ω* new can be expressed as (i)= k (i), i=1, 2,...,n ( (0) = ω init_ft ) (3) where ω init_ft is the initial value of the generator speed after the fault occurrence, i is i th sampling time, and n is the number of sample speeds during the fault duration ΔT, which is calculated by n = ( ) (4) B. LSC Control LSC act as inverter. An Inverter is a device that converts DC to three phase AC electricity, which can be fed directly into the mains grid because LSC operate in sync with the utility grid and produce electricity that is identical to utility grid power. The inverter used here is IGBT-diode based bridge configuration inverter. The IGBT switch of the bridge are controlled by the PWM pulses through both the PI and fuzzy logic controller. The line side converter controls the DC link voltage at normal condition. Under fault condition the LSC act as STATCOM by injecting the required reactive power into grid according to the grid code. Fuzzy logic controller and PI controller combine to control the current in the inner loop and voltage in the outer loop. The voltage at the point of common coupling (PCC) is given by E PCC = E g + Z g I LSC (5) where I LSC is the LSC compensated current. During unbalanced grid sags, the positive- and negativesequence components are adopted for the LSC [19]. The negative and positive sequence is calculated from DC link output voltage [20].Fuzzy logic controller is used to control the DC link voltage by controlling the cuk converter. During the grid sag, ESS controls the dc-link voltage. Hence, an initial error, ΔVdc_I_int, of the integral regulator is set to zero. ΔVdc_I_int=0. (6) V.CONTROL OF ESS AND BC The ESS and the BC are used to suppress the output power fluctuation in normal conditions. But during fault condition, the ESS and BC controls DC link voltage instead of LSC. A. DC- link voltage control. During grid sags, the dc-link voltage of the back-to-back converter is controlled by the ESS through FLC as shown in Fig 6. The outer fuzzy logic voltage controller produces a current reference for an inner current controller. Dynamic equation of DC link voltage is expressed as 120 K.SEETHA DEVI et al

P gen - P BC - P ESS = C (7) where C is the dc-link capacitance, P gen is the generator power, P BC is the power dissipated by the BC, and P ESS is the power of the ESS,ESS voltage is V ESS, and the EDLC current I ESS, as P ESS = V ESS I ESS (8) The I* ESS is given as, =K P2 ( -V dc)+ ( -V dc)+ (9) where K p2 and K I2 are controller gains of the dc-link voltage control. The voltage controller s transfer function is given as (10) B. CUK converter control The CUK converter shown in Fig 5 used to control the EDLC through controller action. Since the CUK converter made of boost-buck principle, it consists of inductor both in the input and output side. This in turn helps to reduce the ripple loss. where K pc and K Ic are gains of the current control. The duty cycle is D ESS = (13) Fig.6. structure of EDLC D. BC control During fault period, the rest of power is dissipate through BC. The duty ratio P BC =P gen -P ESS (14) D s3 = P BC (15) where R bc is the braking resistance. Fig.5. cuk converter C. EDLC current control The wind turbine produce fluctuating power. So, to produce steady, smooth and continuous power, energy storage system EDLC shown in Fig 7 is used in between generator and grid. Current control for converter involves the estimation of voltage across inductance (11) where L f is the boost inductance, and D ESS is the duty cycle. The output of the current controller, =K pc ( - )+ ( - ) (12) VI. CONTROLLER A.PI controller PI controller shown in Fig 8 is used to control the IGBT switches of line side converter and grid side converter. A PI Controller (proportional-integral controller) is a special case of the PID controller in which the derivative (D) of the error is not used. e k p (proportional) Ki (integral) Fig.7. General diagram of PI controller u 121 K.SEETHA DEVI et al

FLC KNOWLEDGE BASE Rule Base Data Base Fuzzy Fuzzy FUZZIFICATION DECISION MAKING DEFUZZIFICATION Real Real d e (k) de(k)=e(k)-e(k-1) Input e (k) + - Error Amplifier Crisp value d(k)=d(k-1)+de(k) v ref vi v DC-DC e CONVERTER Fig. 8. Fuzzy logic controller. The combination of proportional and integral terms is important to increase the speed of the response and also to eliminate the steady state error. The PID controller block is reduced to P and I blocks as shown in figure. B. Fuzzy logic controller Fuzzy control system shown in fig 9 is used to control the cuk converter, generator side converter and line side converter. A fuzzy control system is a control system based on fuzzy logic a mathematical system that analyses analogy input values in terms of logical variables that take on continuous values between 0 and 1, in contrast to classical or digital logic, which operates on discrete values of either 1 or 0 (true or false, respectively). The objective of this dissertation is to control the output voltage of the Cuk converter. It also controls the switching pulse of the GSC and LSC converter combined with PT controller. Fuzzy control system design is based on empirical methods, basically a methodical approach to trial-and-error. The general process is as follows: -Document the system's operational specifications and inputs and outputs. -Document the fuzzy sets for the inputs. -Document the rule set. -Determine the defuzzification method. -Run through test suite to validate system, adjust details as required. -Complete document and release to production. SIMULATION OUTPUT In order to check the performance of the proposed system, the PMSG wind energy conversion system is constructed via MATLAB/SIMULINK. Fig.9. Performance of generator under unbalance sag simulation. (a) Generator speed. (b) Generator power. (c) q-axis generator current. (d) d-axis generators current. 122 K.SEETHA DEVI et al

Fig.10. Performance of ESS and BC under unbalanced sag. (a) DC- link voltage. (b)ess voltage.(c)ess power.(d)bc current. Figure.11.Performance of LSC under unbalanced sag. (a)grid voltage.(b)q-axis positive sequence current. (c)d-axis positive sequence current. (d)q-axis negative sequence current. (e)d-axis negative sequence current. (f)grid current. CONCLUSION This paper use combination of both the PI and fuzzy logic controller to control the GSC and LSC. The fuzzy logic control system alone to control the ESS. The BC is used to dissipate the excess power. The LVRT is achieved by using ESS and BC to control the DC-link voltage and LSC to inject the required reactive power to the grid according to grid code. This technique which is used in PMSG wind turbine system to produce power with less fluctuation is verified using MATLAB/SIMULINK. This simulation result shows that even though both PI and fuzzy logic controller are able to produce the same output power, the fuzzy logic controller helps to simplify the process as far as possible by eliminating the complexity involved in using the PI controller alone in the system. TABLE: PARAMETER OF PMSG PARAMETERS VALUES Rated power Generator current Stator resistance Stator inductance 1.5MW 0.9 A 0.18 Ω 8.5Mh Number of poles 4 Moment of inertia 0.00062 kg m 2 ESS voltage BC resistance 1200 V 100 Ω 123 K.SEETHA DEVI et al REFERENCES [1]. M. Liserre, R. Cardenas, M. Molinas, and J. Rodriguez, Overview of multi-mw wind turbines and wind parks, IEEE Trans. Ind. Electron., vol. 58, no. 4, pp. 1081 1095, Apr. 2011. [2]. A. Garces and M. Molinas, A study of efficiency in a reduced matrix converter for offshore wind farms, IEEE Trans. Ind.

Electron., vol. 59, no. 1, pp. 184 193, Jan. 2012. [3]. Chad Abbey and Geza Joos, Super capacitor energy storage for wind energy applications, IEEE transaction on industry applications vol 43, no. 3, may/ June 2007. [4]. Marco Liserre, Roberto Cárdenas, Marta Molinas and José Rodríguez, Overview of Multi-MW Wind Turbines and Wind Parks. IEEE transactions on industrial electronics, vol. 58, no. 4, April 2011. [5]. Akie Uehara, Alok Pratap, Tomonori Goya, Tomonobu Senjyu, Atsushi Yona, Naomitsu Urasaki and Toshihisa Funabashi, A Coordinated Control Method to Smooth Wind Power Fluctuations of a PMSG-Based WECS.. IEEE transactions on energy conversion, vol. 26, no. 2, June 2011. [6]. Mats Wang-Hansen, Robert Josefsson, and Haris Mehmedovic Frequency Controlling Wind Power Modelling of Control Strategies IEEE transactions on sustainable energy, vol. 4, no. 4, October 2013. [7]. Hamid Shariatpanah, Roohollah Fadaeinedjad and Masood Rashidinejad, A New Model for PMSG-Based Wind Turbine With Yaw Control. IEEE transactions on energy conversion, vol. 28, no. 4, December 2013. [8]. Gustavo Revel, Andres E. Leon, Diego M. Alonso and Jorge L. Moiola, Dynamics and Stability Analysis of a Power System With a PMSG-Based Wind Farm Performing Ancillary Services. IEEE transactions on circuits and systems: regular papers, vol. 61, no. 7, July 2014. [9]. Alejandro Garcés and Marta Molinas, A Study of Efficiency in a Reduced Matrix Converter for Offshore Wind Farms. IEEE transactions on industrial electronics, vol. 59, no. 1, January 2012. [10]. Mamadou Bailo Camara, Hamid Gualous, Frederic Gustin and Alain Berthon, Design and new control of DC/DC converters to share energy between super capacitors and batteries in hybrid vehicles, IEEE transaction on vehicular technology, vol 57, No. 5, September 2008. [11]. Ki-Hong, Yoon Cheul Jeung, Dong Choon Lee and Heung Geun Kim, LVRT scheme of PMSG wind power system based on feedback linearization, IEEE transaction on power electronics vol.27, No.5, may 2012. [12]. Nishad Mendis, Kashem M. Muttaqi and Sarath Perera, Management of Battery- Super capacitor Hybrid Energy Storage and Synchronous Condenser for Isolated Operation of PMSG Based Variable-Speed Wind Turbine Generating Systems, IEEE transactions on smart grid, vol. 5, no. 2, march 2014. [13]. Marta Molinas, Jon Are Suul and Tore Undeland, Low voltage ride through of wind farm with cage generators: STATCOM versus SVC, IEEE transactions on power electronics, vol 23, No. 3, may 2008. [14]. Li Wang, Senior Member and Dinh-Nhon Truong Dynamic Stability Improvement of Four Parallel-Operated PMSG-Based Offshore Wind Turbine Generators Fed to a Power System Using a STATCOM IEEE transactions on power delivery, vol. 28, no. 1, January 2013. [15]. Li Wang and Mi Sa-Nguyen Thi Stability Enhancement of Large-Scale Integration of Wind, Solar, and Marine-Current Power Generation Fed to an SG-Based Power System Through an LCC-HVDC Link, IEEE transactions on sustainable energy, vol. 5, no. 1, January 2014. [16]. Kuang Li, Jinjun Liu, Zhaoan Wang and Biao Wei, Strategies and operating point optimization of STATCOM control for voltage unbalance mitigation in three phase three wire system, IEEE transaction of power delivery, vol 22, No. 1, January 2007. [17]. Yuanye Xia, Khaled H. Ahmed and Barry W. William, "Wind Turbine Power Coefficient Analysis of a New Maximum Power Point Tracking Technique, IEEE transactions on industrial electronics, vol. 60, no. 3, march 2013. 124 K.SEETHA DEVI et al

[18]. Thanh Hai Nguyen and Dong-Choon Lee, Advanced Fault Ride-Through Technique for PMSG Wind Turbine Systems Using Line- Side Converter as STATCOM, IEEE transactions on industrial electronics, vol. 60, no. 7, July 2013 [19]. H.-S. Song and K. Nam, Dual current control scheme for PWM converter under unblanced input voltage conditions, IEEE Trans. Ind. Appl., vol. 46, no. 5, pp. 953 959, Oct. 1999. [20]. J.-I. Jang and D.-C. Lee, High performance control of three-phase PWM converters under nonideal source voltage, in Proc. IEEE ICIT, Dec. 2006, pp. 2791 2796. 125 K.SEETHA DEVI et al

126 K.SEETHA DEVI et al