EDOF-IOLs: Are they all the same?

Similar documents
Improving Lifestyle Vision. with Small Aperture Optics

Dr. Magda Rau Eye Clinic Cham, Germany

Special Publication: Ophthalmochirurgie Supplement 2/2009 (Original printed issue available in the German language)

EDoF IOL. ZEISS AT LARA 829MP Next generation Extended Depth of Focus Intraocular Lens. NEW EDoF IOL from ZEISS

AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

IOL Types. Hazem Elbedewy. M.D., FRCS (Glasg.) Lecturer of Ophthalmology Tanta university

NEW. AT LISA tri 839MP and AT LISA tri toric 939MP from ZEISS The innovative trifocal IOL concept providing True Living Vision to more patients

7 DO IT. A SAFER WAY TO TRIFOCALITY * : ELEVATED PHASE SHIFT (EPS) ** 7 DIFFRACTIVE RINGS FOR OPTIMAL LIGHT DISTRIBUTION AND LESS DISTURBANCE

Financial disclosure. Alcon, Zeiss, J&J AMO, Physiol, Thea, Allergan, Santen, Dompe, Cutting Edge) Race for Progress!

Treatment of Presbyopia during Crystalline Lens Surgery A Review

Long-term quality of vision is what every patient expects

Centre Hospitalier Universitaire et Psychiatrique de Mons-Borinage. B-Flex Multifocal. Dr Emmanuel Van Acker Belgium

Financial Disclosure. Acufocus. Presbyopia Surgery. Inlay Concept 8/14/17. Presbyopia Correction: The Holy Grail of Ophthalmology

SEE BEYOND WITH FULLRANGE OPTICS. Developed by Hanita Lenses

Quality of Vision With Multifocal Progressive Diffractive Lens: Two-Year Follow-up

Advances in the design and

Maximum Light Transmission. Pupil-independent Light Distribution. 3.75D Near Addition Improved Intermediate Vision

Choices and Vision. Jeffrey Koziol M.D. Friday, December 7, 12

NOW. Approved for NTIOL classification from CMS Available in Quar ter Diopter Powers. Accommodating. Aberration Free. Aspheric.

Choices and Vision. Jeffrey Koziol M.D. Thursday, December 6, 12

Crystalens AO: Accommodating, Aberration-Free, Aspheric Y. Ralph Chu, MD Chu Vision Institute Bloomington, MN

Multifocal Progressive Diffractive Lens to Improve Light Distribuition and Avoid Light Loss: Two Years Clinical Results

Research Article In Vitro Aberrometric Assessment of a Multifocal Intraocular Lens and Two Extended Depth of Focus IOLs

Forget Most Everything! The Surgical Management of Presbyopia 2/23/2016. Refraction vs. Diffraction. Presbyopic IOL s Patient Expectations

Unique Aberration-Free IOL: A Vision that Patients

MINI WELL A Better Vision

Sulcoflex. For when perfection is the only option! Pseudophakic Sulcus Fixated Secondary IOLs. Sulcoflex Aspheric. Sulcoflex Toric

Maximising Treatment Outcomes with Premium IOL Technology. Saturday 13 September 2014 XXXII Congress of the ESCRS London, UK.

ROTATIONAL STABILITY MAKES THE DIFFERENCE

PROGRESSIVE VISION WITHIN FULL ACCOMMODATIVE RANGE

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs

IOL Predictions for the Coming Year

NEW THE WORLD S FIRST AND ONLY SINUSOIDAL TRIFOCAL IOL

Clinical Update for Presbyopic Lens Options

RayOne Hydrophobic IOL. New design. New standard MADE IN UK

Comparison between clinical results of two diffractive multifocal lenses with the same platform but different additions

Product Portfolio. Sulcoflex Pseudophakic Supplementary IOLs. Your skill. Our vision.

Multifocal IOL Basics

PATIENT SELECTION THE RIGHT PATIENT UNDERPROMISE AND OVERDELIVER THE PERFECT SPECTACLE FREE TREATMENT. Desires Less Dependence on glasses

Patient information. Your options for cataract treatment Enjoy clear vision at all distances with multifocal IOLs

Evolution of Diffractive Multifocal Intraocular Lenses

Aberrations Before and After Implantation of an Aspheric IOL

CONTENTS. HYDROPHILIC IOLs. Bi-Flex PIL-MA hydrophilic preloaded P / PY 677PT / PTY 677PMY 677PMTY. Bi-Flex HL...

Easy to identify: The color-coded forceps and scissors make identification during September September September 2016

10/25/2017. Financial Disclosures. Do your patients complain of? Are you frustrated by remake after remake? What is wavefront error (WFE)?

*Simulated vision. **Individual results may vary and are not guaranteed. Visual Performance When It s Needed Most

day night convinced supreme contrast sensitivity THE IOL FOR DAY & NIGHT

the ne t generation Experts Uncover Innovative solutions for presbyopia, laser refractive cataract surgery IOLs, AMD, and more.

The design is distinctive. The outcomes are clear. Defocus tolerance 1 Glistening-free performance 1,2 Predictable outcomes 1

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

Raise your expectations. Deliver theirs.

Not everyone can do this. Introducing RayOne with patented Lock & Roll TM technology for the smallest fully preloaded IOL incision

Visual function after bilateral implantation of apodized diffractive aspheric multifocal intraocular lenses with a D3.0 D addition

LEAVE A LEGACY OF VISUAL FREEDOM. TECNIS PRESBYOPIA-CORRECTING IOLs

Glistening-Free Hydrophobic Acrylic IOL. Glistening-Free Hydrophobic Acrylic IOL

FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE

Retinal stray light originating from intraocular lenses and its effect on visual performance van der Mooren, Marie Huibert

American National Standard for Ophthalmics. Extended Depth of Focus Intraocular Lenses

WHY EDOF INTRAOCULAR LENSES? FOR EXCELLENT VISION QUALITY TO SUPPORT AN ACTIVE LIFESTYLE PATIENT INFORMATION. Cataract treatment

Accommodating IOL s History and Clinical Management

Diffractive Optics. Multifocal Lenses. Correction of Pseudophakic Presbyopia with Multifocal IOLs. Basic Designs

Evolution of the Cataract Patient

Surgical data reveals that Q-Factor is important for good surgical outcome

Multifocal and Accommodative

In vitro comparative optical bench analysis of a spherical and aspheric optic design of the same IOL model

CONSISTENT ADVANCES IN CATARACT SURGICAL

Vision for What They Love.

Roadmap to presbyopic success

Trust your eyes. Presbyopic treatment methods on the cornea. PresbyMAX Decision criteria and patient s acceptance

ASPIRA PUBLICATION LIST

Visual and Optical Performances of Multifocal Intraocular Lenses with Three Different Near Additions: 6-Month Follow-Up

IOL Review and FLACS Update

Through-Focus Optical Bench Performance of Extended Depth-of-Focus and Bifocal Intraocular Lenses Compared to a Monofocal Lens

Multifocal Intraocular Lenses for the Treatment of Presbyopia: Benefits and Side-effects

Disclosures. Opportunities for speciality contact lenses in the multifocal market. Principals. Prof James Wolffsohn

Wearable see-thru binocular simulator of multifocal and monovision presbyopic corrections

Schwind Amaris 1050 Smart Pulse Technology

THE XTRAFOCUS IS AN ELEGANT SOLUTION TO COMPLEX CASES.

FOR PRECISE ASTIGMATISM CORRECTION.

October 2017 Sponsored by Oculentis

Clinical Evaluation 3-month Follow-up Report

Amico Yasna Pars. What s Inside. Leader in Healthcare Specialty Markets. Ophthalmology Newsletter. Science & Technology Page 1

COMPARISON OF THE MEDICONTUR 860FAB

Binovision A new Approach for Seeing without Glasses

VISUAL ACUITY AND IMAGE QUALITY IN FIVE DIFFRACTIVE. Short title: Visual acuity and image quality in five diffractive intraocular lenses

Causes of refractive error post premium IOL s 3/17/2015. Instruction course: Refining the Refractive Error After Premium IOL s.

Preloaded. PreciSAL. EZ Toric

The complete choice in refractive lens solutions

The Appearance of Images Through a Multifocal IOL ABSTRACT. through a monofocal IOL to the view through a multifocal lens implanted in the other eye

The Miracle of Pi in Eye. Rajesh Khanna, MD

Advanced Technology IOLs

Design and qualification of a diffractive trifocal optical profile for intraocular lenses

Assessing Visual Quality With the Point Spread Function Using the NIDEK OPD-Scan II

Postoperative Wavefront Analysis and Contrast Sensitivity of a Multifocal Apodized Diffractive IOL (ReSTOR) and Three Monofocal IOLs

American Society of Cataract and Refractive Surgery

Customized intraocular lenses

Corneal Asphericity and Retinal Image Quality: A Case Study and Simulations

Comparative Study Between the High Order Aberrations Before and After Cataract Surgery Using Two Different Types of IOLS

Comparison of Contrast Sensitivity, Higher- Order Aberrations and Subjective Visual Function after Different Aspheric Intraocular Lenses Implantation

When I began my career as an ophthalmologist,

Transcription:

Gerd.Auffarth@med.uni-heidelberg.de www.ivcrc.com www.djapplelab.com EDOF-IOLs: Are they all the same? G. U. Auffarth International Vision Correction Research Centre (IVCRC), The David J. Apple International Laboratory for Ocular Pathology Department of Ophthalmology, Ruprecht-Karls-University of Heidelberg Chairman: G. U. Auffarth, MD, PhD, FEBO

IVCRC / DJ Apple Laboratory: Financial Disclosure 2017/2018 Acufocus 1 Alcon/Novartis 1,2,3,4 Alimera 1,2 Allergan 2,3,4 AMO/Johnson&Johnson 1,2,3,4 Bausch+Lomb 2,3 Carl Zeiss Meditec 1,2,3 Contamac 1 Glaukos 1,2,3 Hoya 1,2,3 HumanOptics 1,3 Kowa 1,2,3 LENSAR 1 Oculentis 1,2,3 Oculus 1,2,3 Ophtec 1 Physiol 1 Polytech 2,3 Powervision 1 Presbia 2,3,4 Rayner 1,2,3 RxSight 4 SIFI 1,2,3 Ursapharm 1,2,3 1 = Research Grants; 2 = Travel Expenses; 3 = Lecture Fees; 4 = Consulting

What are we measuring in EDOF? Near /Intermediate Visual Acuity? Defocus curve (subjectively)? Only Intermediate Visual Acuity? Through Focus Scan/ Defocus curve (Objectively)?

EDOF/EROV IOLs IOLs with mit verbesserter enhanced depth Tiefenschärfe of focus Tecnis Symfony EROV IOL (AMO, USA) Tecnis Symfony EROV IOL (Abbott, USA) Gesamt Ø 13.00 mm Optik Total Ø diameter 6.013.00 mm mm Design Optic diameter 1-stückig 6.00 mm Optik Design asphärisch, 1-piece achromatisch, Optic diffraktiv, aspherical, Echelette achromatic, Design Optikmaterial diffractive, hydrophobes Echelette design Acrylat Optic material hydrophobic acrylic Mini Well Ready (SIFI, Italy) Italien) Gesamt Total diameter Ø 10.75 10.75 mm mm Optik Ø 6,0 mm Optic diameter 6.00 mm Design 1-stückig Design 1-piece Optik Bkonvex, progressive, multifokal, Optic asphärisch biconvex progressive Optikmaterial hydrophiles multifocalacrylat aspherical Copolymer Optic material hydrophilic acrylic

EDOF/EROV IOLs IOLs with mit verbesserter enhanced depth Tiefenschärfe of focus Tecnis IC-8 Small Symfony Aperture EROV IOL (Acufocus, IOL (AMO, USA) USA) Gesamt Total diameter Ø 13.00 12.50 mm mm Optik OpticØ diameter 6.06.00 mm mm Design 1-stückig 1-piece Optik Optic asphärisch, Small aperture achromatisch, dimensions diffraktiv, 1.36 mm Echelette aperture Design Optikmaterial hydrophobes 3.23 mm total Acrylat diameter Optic material hydrophobic acrylic Mini LS 313 Well MF15 Ready Lentis (SIFI, Comfort Italien) (Oculentis, Germany) Gesamt Total diameter Ø 10.75 11.00 mm mm Optik Ø 6,0 mm Optic diameter 6.00 mm Design 1-stückig Design 1-piece Optik Bkonvex, progressive, multifokal, Optic asphärisch asymmetrical, sector Optikmaterial hydrophiles shaped refractive Acrylat Copolymer +1.5 Dpt. near addition Optic material hydrophilic acrylic

Visualising Optical Pathway of EDOF IOLs* *Data on file and Copyright: The David J Apple International Laboratory for Ocular Pathology, Dept. of Ophthalmology, University of Heidelberg, Germany PP2016CT1473

Visualising Optical Pathway of EDOF IOLs* *Data on file and Copyright: The David J Apple International Laboratory for Ocular Pathology, Dept. of Ophthalmology, University of Heidelberg, Germany

Visualising Optical Pathway of EDOF IOLs* Miniwell Ready Symfony ZXR00 Lentis 313 MF15 AT Lara 829 MP *Data on file and Copyright: The David J Apple International Laboratory for Ocular Pathology, Dept. of Ophthalmology, University of Heidelberg, Germany

EDOF-Concept Echelette design feature Achromatic technology + Symfony Mini Well

Extended Range of Vision IOL: Tecnis Symfony Prospective Cases series Aim: Analysis of functional outcome after bilateral implantation of the Tecnis Symfony Methods: 40 Centres worlswide 411 Eyes in 2 Groups: Micro-Monovision vs. Non-Monovision Clinical evaluation: Pre-OP and 4-8 weeks Post- OP Cochener B; Concerto Study Group. Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study. J Cataract Refract Surg. 2016 Sept;42(9):1268-1275

Extended Range of Vision IOL: Tecnis Symfony Mean UDVA: 0.95 in both groups, 0.94 in Micro-Monovision, 0.95 in Non-Monovision (p=0.485) Mean UIVA: 0.82 in both groups, 0.88 in Micro-Monovision, 0.79 in Non-Monovision (p=0.003) Mean UNVA: 0.69 in both Groups, 0.74 in Micro-Monovision, 0.67 in Non-Monovision (p=0.011) Cochener B; Concerto Study Group. Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study. J Cataract Refract Surg. 2016 Sept;42(9):1268-1275

Extended Range of Vision IOL: Tecnis Symfony Cochener B; Concerto Study Group. Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study. J Cataract Refract Surg. 2016 Sept;42(9):1268-1275

Extended Range of Vision IOL: Tecnis Symfony Halos: No to Mild 90.3% in both groups, 87.0% in Micro-Monovision, 91.6% in Non-Monovision Glare:No to Mild 93.0% in both groups, 96.0% in Micro-Monovision, 91.9% in Non-Monovision Starbust:No to Mild 97.3% in both groups, 96.4% in Micro-Monovision, 97.6% in Non-Monovision Cochener B; Concerto Study Group. Clinical outcomes of a new extended range of vision intraocular lens: International Multicenter Concerto Study. J Cataract Refract Surg. 2016 Sept;42(9):1268-1275

SIFI Mini Well Ready

Optical Concept SIFI Mini Well Ready +W (μm) -W (μm)

Defocus: SIFI Mini Well Ready MiniWell EDOF IOL Multifokale (diffraktive) IOL Monofokale IOL

Visual Acuity: Mini Well EDOF IOL* Prospective non-randomized clinical study, EC approval 27 eyes of 14 patients Preoperative SE: Median 0.50 D (range: -7.75 to 4.88 D) *Data on file: International Vision Correction Research Centre (IVCRC), : Presented ESCRS 2016

Enhanced Depth of Focus IOLs Performance: Intermediate Vision and Reading ability Evaluation with Salzburg Reading Desk (SRD)

Methods: Salzburg Reading Desk (SRD) Objective Evaluation of Reading Performance

SRD: Symfony / MiniWell EDOF IOL* Symfony Median uncorrected binocular (n=13) Near (40cm) Preferred Near Intermediate (80cm) Preferred Intermediate Visual Acuity (logmar) 0.10 0.13 0.11 0.11 Distance (cm) 40.30 39.50 79.20 62.80 Mini Well Letter Size (log-scaled) 1.25 1.25 1.25 1.00 Median distance-corrected binocular (n=13) Near (40cm) Preferred Near Intermediate (80cm) Preferred Intermediate Visual Acuity (logmar) 0.21 0.19 0.10 0.12 Distance (cm) 40.30 38.90 79.40 60.00 Letter Size (log-scaled) 1.50 1.50 1.25 1.00 *Data on file: International Vision Correction Research Centre (IVCRC), :Presented ESCRS 2016

Enhanced Depth of Focus IOLs Performance: Defocus curves

Results: Defocus Curve* Mini Well EDOF IOL 2.25 Dpt 3.0 Dpt 1.8 Dpt 2.7 Dpt Symfony EDOF IOL *Data on file: International Vision Correction Research Centre (IVCRC),

Enhanced Depth of Focus IOLs Side effects: Halo & Glare

Halo & Glare Simulator* Screenshot of patient s exam with Halo & Glare Simulator (Eyeland Design Network, Vreden, Germany) *Data on file: International Vision Correction Research Centre (IVCRC), : Presented ESCRS 2016

Results: Perception Halo Type of Halos* 100% 90% 80% Halo Type 70% 60% 50% 40% Starburst Halo None 30% 20% 10% 0% Miniwell Z7560CZ n=14 Symfony ZXR00 n=7 Panop x TFNT00 n=10 Aspira MC 6125 AS n=12 EDOF EDOF TRIFOCAL MONOFOCAL *Data on file: International Vision Correction Research Centre (IVCRC), : Presented ESCRS 2016

Results: Representation of Mean Values* *Data on file: International Vision Correction Research Centre (IVCRC), : Presented ESCRS 2016

Results: Representation of Maximum Values* *Data on file: International Vision Correction Research Centre (IVCRC), : Presented ESCRS 2016

IC-8 Extended Depth of Focus IOL Optic Design Single piece hydrophobic acrylic 6.00 mm optic diameter 12.50 mm overall diameter Mask PVDF & nano-particles of carbon 1.36 mm aperture 3.23 mm total diameter 3200 microperforations 5 microns thick A-constant: 120.5 Diopter Range: +20.0 D to +27.5 D (Equivalent to +18.0 D with a typical lens due to A-constant) Injector System 3.5 mm incision for capsular bag insertion, non-folding, single use 28

AcuFocus IC-8 IOL +2.0 D +1.0 D 0.0 D -1.0 D 21.0 D -2.0 D 11979-2 ISO Standard Bench testing by The Pilot Group 29

AcuFocus IC-8 IOL: Prospective Multicentre Trial* Results: The study comprised 105 patients. At 6 months, the UDVA, UIVA, and UNVA in eyes with the small-aperture IOL were 20/23, 20/24, and 20/30, respectively. Ninety-nine percent, 95%, and 79% of patients achieved 20/32 or better binocular UDVA, UIVA, and UNVA, respectively. *Dick HB, Piovella M, Vukich J, Vilupuru S, Lin L.Prospective multicenter trial of a small-aperture intraocular lens in cataract surgery. J Cataract Refract Surg. 2017 Jul;43(7):956-968

AcuFocus IC-8 IOL: Prospective Multicentre Trial* *Dick HB, Piovella M, Vukich J, Vilupuru S, Lin L.Prospective multicenter trial of a small-aperture intraocular lens in cataract surgery. J Cataract Refract Surg. 2017 Jul;43(7):956-968

Case: Male, 72 years old Diagnosis: OD/OS Hyperopia, Cataract OS: Pterygium, irregular Astigmatism Pre-OP Prescription: OD +3,25-0,75 076= 0,50 OS +3,75-0,75 123= 0,32 Patient wish for spectable independence

Case: Male, 72 years old OD/OS: FLACS (LensX) with implantation of: OD: Oculentis Mplus 20 OS: Acufocus IC-8

Case: Male, 72 years old

Case: Male, 72 years old Post-OP OD (1w) OS (1w) BIN UDVA 0,8 0,63++ 0,8-1,0 Refraction -0,50 sph -0,50-1,0 165 BCDVA 0,8 0,8 1,0 UNVA 0,63 0,5 0,63 Post-OP OD (1-2m) OS (1-2m) BIN UDVA 0,8 0,8 1,0 Refraction 0,25-0,5 160-0,25-1,0 140 BCDVA 1,0 1,0 1,25 UNVA 0,63 0,8 0,8

Lentis Comfort LS-313 MF15, Oculentis) Segmental refractive MIOL with Near Add of +1.50 D LS-313 MF15 Optic Design Material Near addition Optic size Overall length Available Diopters Aspherical surface posterior, sectorshaped nearvision segment anterior Optic and haptics with square edges, posterior 360 continuous barrier effect Copolymer consisting of acrylates with hydrophobic surface, UV absorbing +1.5 D 6.0 mm 11.0 mm -10.0 D to -1.0 D (1.0 D increments) ±0.0 D to +36.0 D (0.5 D increments)

Prospective clinical Study LS-313MF15 Visus UDVA [logmar] CDVA [logmar] UNVA [logmar] DCNVA [logmar] CNVA [logmar] Nah add [D] UIVA [logmar] DCIVA [logmar] CIVA [logmar] Präoperative Postoperative Median 0.41 0.25 - - - - - - - Min 1.30 0.60 - - - - - - - Max 0.04 0.06 - - - - - - - Median -0.01-0.07 0.43 0.45 0.03 2 0.16 0.18 0.05 Min 0.16 0.10 0.68 0.64 0.20 1.25 0.34 0.40 0.20 Max -0.14-0.22 0.16 0.16-0.12 3 0.04 0.02-0.10 Salzburg Reading Desk (uncorrected) Salzburg Reading Desk (diostance corrected) Subj. Near Intermediate 80 cm Subj Near Intermediat e 80 cm Near 40 cm Subj. Intermediate Near 40 cm Subj. Intermediate

Refractiv-segmental-multifokal (Low Add) Nahaddition + 1,5 Dpt. Defocus curve Oculentis MF15

Summary: EDOF IOLs Clinical results show excellent postoperative visual acuity both for distance and intermediate vision as well as good near visual acuity. High degree of Patient satisfaction. Very low incidence of optical phenomena (halos, glare) especially for Mini Well EDOF IOL reported. Refractive tolerance to sub 1.0 Dpt astigmatism or spherical ametropia with the Tecnis Symfony IOL and IC-8 IOL

Thank you!