Different shapes of tracks in phlogopite, biotite and soda lime glass

Similar documents
Non-intrusive refractometer sensor

High-Speed Scalable Silicon-MoS 2 P-N Heterojunction Photodetectors

Rear Side Processing of Soda-Lime Glass Using DPSS Nanosecond Laser

arxiv: v1 [physics.ins-det] 13 Jul 2018

Fabrication of microstructures on photosensitive glass using a femtosecond laser process and chemical etching

EG2605 Undergraduate Research Opportunities Program. Large Scale Nano Fabrication via Proton Lithography Using Metallic Stencils

Life under low Reynolds numbers How do microorganisms swim?

Waveguiding in PMMA photonic crystals

Investigation of the Near-field Distribution at Novel Nanometric Aperture Laser

Supplementary information for Stretchable photonic crystal cavity with

arxiv: v2 [astro-ph.im] 22 Sep 2011

NANO MODIFICATION OF THE W(100)/ZrO ELECTRON EMITTER TIP USING REACTIVE ION ETCHING

Supplementary Note 1: Structural control of BCs. The availability of PS spheres in various

NANO 703-Notes. Chapter 9-The Instrument

True Three-Dimensional Interconnections

Observation of X-rays generated by relativistic electrons in waveguide target mounted inside a betatron

EXPERIMENTAL INVESTIGATION ON LASER BENDING OF METAL SHEETS USING PARABOLIC IRRADIATIONS

Single-mode fibre coupler as refractometer sensor

Development of High Granulated Straw Chambers of Large Sizes

Investigation of Scintillation Screens for High Energetic Heavy Ion Beams at GSI

LOPUT Laser: A novel concept to realize single longitudinal mode laser

Cavity QED with quantum dots in semiconductor microcavities

Introduction to TOTEM T2 DCS

Automatic scanning of nuclear emulsions with wideangle acceptance for nuclear fragment detection

Soft X-Ray Silicon Photodiodes with 100% Quantum Efficiency

101 W of average green beam from diode-side-pumped Nd:YAG/LBO-based system in a relay imaged cavity

Experience of synchrotron sources and optics modelling at Diamond Light Source

SINGLE EVENT EFFECTS TEST REPORT SEL: 125⁰C SET: 25⁰C. SEL: MeV cm 2 /mg SET: ( ) MeV cm 2 /mg. RADEF, University of Jyväskylä

SINGLE EVENT LATCH-UP TEST REPORT ADCLK925S

Title: Laser marking with graded contrast micro crack inside transparent material using UV ns pulse

Confocal Imaging Through Scattering Media with a Volume Holographic Filter

arxiv:physics/ v1 [physics.optics] 28 Sep 2005

Author(s) Osamu; Nakamura, Tatsuya; Katagiri,

M6 JETSTREAM. Innovation with Integrity. Large Area Micro X-ray Fluorescence Spectrometer. Micro-XRF

Characterization of Surface Structures using THz Radar Techniques with Spatial Beam Filtering and Out-of-Focus Detection

2. Pulsed Acoustic Microscopy and Picosecond Ultrasonics

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

Verification of a Developed Automatic Counting System for Cr-39 Detectors Using Different Image Resolutions

Supplementary Figure S1. Schematic representation of different functionalities that could be

- Near Field Scanning Optical Microscopy - Electrostatic Force Microscopy - Magnetic Force Microscopy

3D simulations of the experimental signal measured in near-field optical microscopy

SUPPLEMENTARY INFORMATION

200 MHz 350 MHz 750 MHz Linac2 RFQ2 202 MHz 0.5 MeV /m Weight : 1000 kg/m Ext. diameter : 45 cm

InGaAsP photonic band gap crystal membrane microresonators*

31th March 2017, Annual ILC detector meeting Tohoku University Shunsuke Murai on behalf of FPCCD group

Selective improvement of NO 2 gas sensing behavior in. SnO 2 nanowires by ion-beam irradiation. Supporting Information.

Study of irradiated 3D detectors. University of Glasgow, Scotland. University of Glasgow, Scotland

SEM Magnification Calibration & Verification: Building Confidence in Your Scale Bar

Transmission electron Microscopy

SUPERCONDUCTING GANTRY AND OTHER DEVELOPMENTS AT HIMAC

Shattered: Forensic Glass Analysis

The SIRAD irradiation facility at the INFN - Legnaro National Laboratory

Status of ITC-irst activities in RD50

MAPPING OF SEE-SENSITIVE REGIONS AND LOCATING OF ADDITIONAL FAILURE MODES RELEVANT FOR RHA IN DIGITAL ISOLATORS

A thin foil optical strain gage based on silicon-on-insulator microresonators

Magnesium and Magnesium-Silicide coated Silicon Nanowire composite Anodes for. Lithium-ion Batteries

Chromatic X-Ray imaging with a fine pitch CdTe sensor coupled to a large area photon counting pixel ASIC

Numerical analysis to verifying the performance of condenser magnetic lens in the scanning electron microscope.

Indiana University JEM-3200FS

Fabrication of Probes for High Resolution Optical Microscopy

ELECTRON MICROSCOPY AN OVERVIEW

A BASIC EXPERIMENTAL STUDY OF CAST FILM EXTRUSION PROCESS FOR FABRICATION OF PLASTIC MICROLENS ARRAY DEVICE

attosnom I: Topography and Force Images NANOSCOPY APPLICATION NOTE M06 RELATED PRODUCTS G

Initial Results from a Cryogenic Proton Irradiation of a p-channel CCD

Experimental and numerical investigation of tube sinking of rectangular tubes from round section

Administrative details:

Printing Beyond srgb Color Gamut by. Mimicking Silicon Nanostructures in Free-Space

Development of silicon detectors for Beam Loss Monitoring at HL-LHC

Real-Time Scanning Goniometric Radiometer for Rapid Characterization of Laser Diodes and VCSELs

Measurement of Microscopic Three-dimensional Profiles with High Accuracy and Simple Operation

CONTACT LASER ULTRASONIC EVALUATION OF CONSTRUCTION MATERIALS

Department of Astronomy, Graduate School of Science, the University of Tokyo, Hongo, Bunkyo-ku, Tokyo , Japan;

Title detector with operating temperature.

Grating-waveguide structures and their applications in high-power laser systems

FABRICATION AND CHARACTERIZATION OF NICKEL NANOWIRES

Compact Gap-coupled Microstrip Antennas for Broadband and Dual Frequency Operations

Vertical field effect transistors realized by cleaved-edge overgrowth

GaAs polytype quantum dots

Development of Personal Dosimeter Using Electronic Dose Conversion Method

Infra-Red Propagation Through Various Waveguide Inner Surface Geometries

Implementation of A Nanosecond Time-resolved APD Detector System for NRS Experiment in HEPS-TF

The design of a radio frequency quadrupole LINAC for the RIB project at VECC Kolkata

Mohammed A. Hussein *

Laser Beam Analysis Using Image Processing

Techniques for blade tip clearance measurements with capacitive probes

Use of Back Scattered Ionizing Radiation for Measurement of Thickness of the Catalytic Agent Active Material

Etching in Microsystem Technology

Surface Analysis of one Pound from the Egyptian Coins

DOING PHYSICS WITH MATLAB COMPUTATIONAL OPTICS. GUI Simulation Diffraction: Focused Beams and Resolution for a lens system

Beams and Scanning Probe Microscopy

Introduction To NDT. BY: Omid HEIDARY

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

Surface resistivity measurements and related performance studies of the Bakelite RPC detectors

Chapter 4 Imaging Lecture 17

Fabrication of Silicon Master Using Dry and Wet Etching for Optical Waveguide by Thermal Embossing Technique

CHAPTER TWO METALLOGRAPHY & MICROSCOPY

Development of Orderly Micro Asperity on Polishing Pad Surface for Chemical Mechanical Polishing (CMP) Process using Anisotropic Etching

The CMS Silicon Strip Tracker and its Electronic Readout

X-ray backscattering: Variable irradiation geometry facilitates new insights

CHIRPED FIBER BRAGG GRATING (CFBG) BY ETCHING TECHNIQUE FOR SIMULTANEOUS TEMPERATURE AND REFRACTIVE INDEX SENSING

Transcription:

Indian J. Phys. 83 (7), 977-983 (2009) Different shapes of tracks in phlogopite, biotite and soda lime glass Mohan Singh, Lakhwant Singh* and Bikram Singh Department of Physics, Guru Nanak Dev University, Amritsar-143 005, India E-mail : lakhwant@yahoo.com Abstract : Etched track opening geometries in Biotite, Phlogopite and soda-lime glass irradiated with swift heavy ions [ 197 Au(11.64 MeV/n), 136 Xe(11.56 MeV/n), 58 Ni(11.56 MeV/n)] at different angle of incidence have been studied using appropriate chemical etching technique. Different geometries (Hexagonal, irregular polygon, triangular in case of Biotite and Phlogopite, and circular & elliptical in case of soda lime glass detector) of heavy ion tracks are reported in the present investigations using optical microscope. The different shapes of these heavy ions track geometries are found to be related with various target-projectile parameters (viz : type of projectiles, energy, stopping power, angle of incidence of the projectile, density of defects and its reactivity with etchant, etching conditions and chemical structure of the detectors). The dependence of different shapes of heavy ion tracks in isotropic and anisotropic medium on the variation of radiation damage densities along the ion trajectories have also been discussed in the present paper. Keywords : Heavy ions; track geometries; phlogopite; biotite; soda-lime glass PACS Nos. : 61.72.Ff; 61.80.Jh; 91.60.Ed 1. Introduction Numerous studies on ion-beam science have focused on the morphology and mechanism of radiation damage in various classes of materials [1-5]. Probing the track structure is not only of academic interest where the nature of tracks is of fundamental importance but ion-track engineering may be developed to a stage allowing controlled fabrication of trackstructured nano-components for electrical and mechanical devices [6]. Chemically etched tracks in solid state nuclear track detectors have great applications in various field of science and technology e.g. radioprotection, medicine, biology, nano-technology [7-9]. In amorphous solid state detectors such as plastics and glasses, the only parameter that * Corresponding Author 2009 IACS

978 Mohan Singh, Lakhwant Singh and Bikram Singh affects the track opening shape is the angle of the projectile with the detector surface i.e. the dip angle [10, 11]. By the variation of dip angle the eccentricity of the elliptical etch pit opening change. Because of the complexities involved in the structure of crystalline materials the track opening shapes in these detectors have complicated geometries. The range of the penetrating ions in these types of detectors (e.g. micas) depends on the angle of incidence of the ion because of the anisotropic effect of layered crystals [12]. Such studies can provide valuable information about the parameters affecting the track shapes that may be used in making microfilters using solid state nuclear track [13-16]. The track opening geometries of heavy ions in various detectors mainly depends on the nature of the detectors. In the present work, track opening geometries of heavy ions [ 197 Au (11.64 MeV/n), 136 Xe (11.56 MeV/n), 58 Ni (11.56 MeV/n)] with different angles of incidence in micas (Biotite, Phlogopite) and soda lime are reported. 2. Detectors In the present work, the natural micacious mineral detectors [Biotite & Phlogopite] were collected from Nilore mica belt, India, while the soda-lime glass detector was procured from polar industrial corporation, Bombay, India. In these dark micas (Biotite & Phlogopite), all octahedrons are occupied with cations such as Mg and Fe. The schematic structure of Phlogopite is shown in Figure 1 [4, 5, 12]. Glass detector play an important role in track study due to particular advantages such as discrimination of light charged particle, freedom of mechanical rigidness, use prone to environmental change and aging effects [17]. Octohodral layer Octohodral layer Silicon Aluminium Magnesium Hydroxyl Figure 1. Schematic diagram of phlogopite mica (KMg 6 Si 6 Al 2 O 20 (OH, F) 4 ).

Different shapes of tracks in phlogopite, biotite and soda lime glass 979 3. Experimental details Freshly cleaved thin sheets (~250 μm) of biotite and phlogopite micas were cut into a number of disks of 3 cm diameter each. The basal plane [001] of the samples were irradiated with 136 Xe (11.56 MeV/n) ions at two different angle of incidence (45 0 and 90 0 ) from UNILAC heavy ion accelerator at GSI Darmstadt, Germany. Samples of soda-lime glass detector were also irradiated with heavy ions [ 58 Ni(11.56 MeV/n), 197 Au(11.64 MeV/n)] at the same angles of incidence (45 0, 90 0 ). The ion fluence in each exposure was kept low (10 4 ions/cm 2 ) to avoid the overlapping of etched tracks. The different irradiated samples were then etched with 40% HF acid at constant temperature of 27 o C for different etching times (4 min, 8 min, 12 min). These etched samples were scanned under the digital optical microscope (BIOLUX, with Scalar 1.0E). 4. Results and discussion The optical images of the heavy ions irradiated micas (Biotite and Phlogopite) and soda-lime glass with different energies and different angles of incidence are shown in the Figures (2-6). It is observed from these images that there are regular hexagonal tracks and irregular polygonal Figure 2. Optical images of heavy ions [ 136 Xe (11.56 MeV/n)] tracks in biotite mica incident at 45 0 and etched in 40% HF at room temperature (27 o C) for etching times (a) 4 min, (b) 8 min and (c) 12 min at magnification of 400X.

980 Mohan Singh, Lakhwant Singh and Bikram Singh tracks in Biotite. Hexagonal tracks are observed for ions having dip angle 90 o and and for inclined ions (45 0 ) at higher etching time. The irregular polygons geometries shift towards regular hexagonal track geometries with the increase of etching time (Figures 2 and 3). These optical images show that there is a triangular track along with the irregular polygons track geometries in Phlogopite mica (Figure 3b). The observation of optical images in biotite and Phlogopite leads to the conclusion that hexagonal tracks are formed by energetic ions entering the detector at dip angle 90 0, polygonal tracks are formed by energetic ions entering the detector at dip angle 45 0, and there is a shift of irregular polygonal track opening (45 0 angle of incidence) to regular hexagonal shape with the increase of etching time. Figure 3. Optical images of heavy ions [ 136 Xe (11.56 MeV/n)] tracks in phlogopite mica incident at 45 0 and etched in 40% HF at room temperature (27 o C) for etching times (a) 4 min, (b) 8 min and (c) 12 min at magnification of 400X. Triangular etch pits are also shown in (b). The orthogonally incident heavy ions leads to etched track hexagonal contour. Our observations support that, these types of hexagonal structure arise due to the natural hexagonal symmetry of the tetrahedral sheet. The triangular track observed in Figure 3b is a result of low energy fission fragments. These triangular structures are due to the natural triangular symmetry of the

Different shapes of tracks in phlogopite, biotite and soda lime glass 981 octahedral sheet. The variation of track geometries along the track is the result of discontinuity in the etchable radiation damage formation along the tracks. Irregular polygonal track geometries are produce when dip angle is not equal to 90 0. The range of the heavy ions and therefore the associated stopping power (or damage) vary strongly with the angle of incidence to the basal plane [12]. Such a dip angle dependence of the stopping power can affect the geometry of the polygonal tracks. If polygonal tracks were heavily etched, most of the polygonal tracks would change to the hexagonal tracks (Figures 2-4). This is analogous to the case of the isotropic detector where elliptical track opening becomes circular when the third phase of the track etching is reached [11]. Figures 5 and 6 show the track opening geometries of various heavy ions [ 58 Ni(11.56 MeV/n), 197 Au(11.64 MeV/n)] in soda-lime glass at different angles of incidence (45 0 and 90 0 ) with respect to the surface of the glass detector. These optical images are taken at different etching time and at 400X magnification using digital optical microsocope. This shows the circular and elliptical track opening geometries of the heavy Figure 4. Optical images of heavy ions [ 136 Xe (11.56 MeV/n)] tracks in biotite mica incident at 90 0 and etched in 40% HF at room temperature (27 o C) for etching times (a) 4 min, (b) 8 min and (c) 12 min at magnification of 400X.

982 Mohan Singh, Lakhwant Singh and Bikram Singh ion tracks. As Figure shows the track opening geometries change from circular to elliptical as the angle of incidence change from 90 0 to 45 0. The track in amorphous detectors does not clearly focus on the structure of the detector as compared to the track registration in crystalline detectors. Figure 5. Optical images of heavy ions [ 58 Ni (11.56 MeV/n)] tracks in soda-lime glass detector incident at 45 0 and etched in 40% HF at room temperature (27 o C) for etching times (a) 4 min, (b) 8 min and (c) 12 min at magnification of 400X. Figure 6. Optical images of heavy ions [ 197 Au (11.64 MeV/n)] tracks in soda-lime glass incident at 90 0 and etched in 40% HF at room temperature (27 o C) for etching times (a) 4 min, (b) 8 min and (c) 12 min at magnification of 400X.

Different shapes of tracks in phlogopite, biotite and soda lime glass 983 5. Conclusions The ion track geometries are found to be related with various target-projectile parameters (viz : type of projectiles, energy, stopping power, angle of incidence of the projectile, density of defects and its reactivity with etchant, etching conditions and chemical structure of the detectors). The density of the radiation damage is related to the stopping power which depends on the angle of incidence of the projectile in anisotropic medium (micas: Biotite and Phlogopite in present case): in turn the shape of the etched track in a particular etchant depends on the angle of incidence of the projectile. Different geometries (Hexagonal, irregular polygon, triangular in case of Biotite and Phlogopite, and circular & elliptical in case of soda lime glass detector) of heavy ion tracks at different angle of incidence are related to the anisotropic and isotropic behaviour of these detectors. References [1] R L Fleischer, P B Price and R M Walker Nuclear Tracks in Solids (Univ. of California Press, Berkeley, California) (1975) [2] D Snowden-Ifft, P B Price, L A Nagahara and A Fujishima Phys. Rev. Lett. 70 2348 (1993) [3] M Seider, U D Schwarz and R Wiesendanger Phys. Rev. B53 R16 180 (1996) [4] S R Hashemi-Nezhad Nucl. Instrum. Meth. B142 98 (1998) [5] M Lang, U A Glasmacher, B Moine, R Neumann and G A Wagner Nucl. Instrum. Meth. B218 466 (2004) [6] D Fink, P S Alegaonkar, A V Petrov, A S Berdinsky, V Rao, M Müller, K K Dwivedi and L T Chadderton Radiat. Meas. 36 605 (2003) [7] L T Chadderton and D W Fink Radiat. Eff. Defects Solids 152 87 (2000) [8] L T Chadderton Radiat. Meas. 36 13 (2003) [9] D Fink and L T Chadderton Radiat. Eff. Defects Solids 160 67 (2005) [10] R P Henke and E V Benton Nucl. Instrum. Meth. 97 483 (1971) [11] G Somogyi and S A Szalay Nucl. Instrum. Meth. 109 211 (1973) [12] L Singh, M Singh, K S Samra and R Singh Nucl. Instrum. Meth. B248 117 (2006) [13] S R Hashemi-Nezhad Nucl. Instrum. Meth. B234 533 (2005) [14] G Trees, M Ellinger, E U Khan, H A Khan, P Vater, R Brandt and M Kadner Nucl. Tracks 6 87 (1982) [15] G Trees, P Vater, E U Khan, H A Khan, R Brandt, M Kadner and R Spohr Proc. 11th int. conf. on SSNTD Bristol (1981) Suppl. 3 to Nucl. Tracks 723 (1982) [16] R Brandt, G Trees, H A Khan, P Vater and J Aerosol Science 14 228 (1964) [17] T Portwood, D L Henshaw and J Stejney Nucl. Tracks 12 109 (1986)