Philip Sperling. Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany.

Similar documents
Discover new dimensions in flexibility

Precision at its finest

v tome x m microfocus CT

Discover the difference in efficiency

Explore the Art of Detection

Manufacturing Metrology Team

Y.MU 2000 Precise inspection results for sampling and 100% inspection

APPLICATION OF THE DIGITAL RADIOGRAPHY IN WELD INSPECTION OF GAS AND OIL PIPELINES

Application Report 11/15/5471 Company: Kienle Spiess

X-Ray Tomography Inspection of SRF Cavities. Elvin Harms 15th International Conference on RF Superconductivity July 2011

Insight into the Inside

X-ray technology for electronics inspection

RADspeed Pro DIGITAL RADIOGRAPHIC SYSTEM. IBD-RADProAeroDR

XT H Series. X-ray and CT technology for industrial applications. nikon metrology I vision beyond precision

Explore the Art of Detection

XT H Series. X-ray and CT technology for industrial applications NIKON METROLOGY I VISION BEYOND PRECISION

XT V Series. X-ray and CT technology for electronics inspection. nikon metrology I vision beyond precision

Design, Development and Integration of a Large Scale Multiple Source X-ray Computed Tomography System

2D Digital Radiography 3D Computed Tomography Inspection Services Laboratories. xrayinspectionservice.com

ON THE WAY TO DIGITAL RADIOGRAPHY

Insight into the Inside

XT V Series. X-ray and CT technology for electronics inspection NIKON METROLOGY I VISION BEYOND PRECISION

Digital Radiography and X-ray Computed Tomography Slice Inspection of an Aluminum Truss Section

Alignment of the camera

Tomographic 3D-Radiometry for the Visualisation and Measurement of the Defects of Girth Seams

TECHNICAL DATA. OPTIV CLASSIC 322 Version 3/2013

Migrating from traditional to Digital Radiography in Aerospace

Bringing Answers to the Surface

Advances in X-Ray Technology for Semicon Applications Keith Bryant and Thorsten Rother

XT V Series. X-ray and CT technology for electronics inspection. nikon metrology I vision beyond precision

Moving from film to digital: A study of digital x-ray benefits, challenges and best practices

THE CR SPECIALISTS HD-CR CR 35 NDT

Maximizing clinical outcomes

Related topics Beam hardening, cupping effect, Beam hardening correction, metal artefacts, photon starvation

SMX-1000 Plus SMX-1000L Plus

Product Information Version 1.1. ZEISS Xradia 410 Versa Submicron X-ray Imaging: Bridge the Gap in Lab-based Microscopy

OPTIMIZING SPATIAL RESOLUTION WITH THE MECHANICAL DESIGN OF AN X-RAY COMPU1ED TOMOGRAPHY SCANNER

Fig.2: Scanner VistaScan for image plates

TECHNICAL DATA OPTIV CLASSIC 432

Variable microinspection system. system125

Digital Radiography : Flat Panel

DATA SHEET GLOBAL EVO. Bridge Coordinate Measuring Machines

Data. microcat +SPECT

Quality Control for X-Ray Systems A Tool Chain for NDT Applications

AUTOMATED AND QUANTITATIVE METHOD FOR QUALITY ASSURANCE OF DIGITAL RADIOGRAPHY IMAGING SYSTEMS

Digital Radiographic Inspection replacing traditional RT and 3D RT Development

X-ray Inspection Systems 2D AXI / 3D AXI / WAXI

inspexio SMX-225CT FPD HR

Geometric image distortion in flat-panel X-ray detectors and its influence on the accuracy of CT-based dimensional measurements

JEM-F200. Multi-purpose Electron Microscope. Scientific / Metrology Instruments Multi-purpose Electron Microscope

DEVELOPMENT CENTER X-RAY TECHNOLOGY EZRT XEYE. Radiation proof X-ray detectors for industrial applications

MULTIPLE NDT METHODS IN THE AUTOMOTIVE INDUSTRY P. Buschke, W.Roye, T. Dahmen GE Inspection Technologies, Huerth, Germany

BF-X2. In-line 3D automated X-ray inspection system for Semiconductor, Power module inspection

Uncertainty in CT Metrology: Visualizations for Exploration and Analysis of Geometric Tolerances

Freeze-fixation of bubbles for micro-ct imaging of liquid aerated food emulsions

1. Patient size AEC. Large Patient High ma. Small Patient Low ma

COMPUTED TOMOGRAPHY 1

P a n o r a m i c a n d C e p h a l o m e t r i c X - r a y s

OTC18 OVERHEAD TUBE CRANE SYSTEM

HIGH RESOLUTION COMPUTERIZED TOMOGRAPHY SYSTEM USING AN IMAGING PLATE

Leading in Desktop SEM Imaging and Analysis

Principles of CT scan

Digital Radiography for the Inspection of Small Defects

attocfm I for Surface Quality Inspection NANOSCOPY APPLICATION NOTE M01 RELATED PRODUCTS G

MC SIMULATION OF SCATTER INTENSITIES IN A CONE-BEAM CT SYSTEM EMPLOYING A 450 kv X-RAY TUBE

M6 JETSTREAM. Innovation with Integrity. Large Area Micro X-ray Fluorescence Spectrometer. Micro-XRF

RaySafe X2. Effortless measurements of X-ray

High Energy Digital Radiography & 3D-CT for Industrial Systems

Medical Imaging. Latest generation bucky room. system. radiology ahead

IQI-Sensitivity and Applications of Flat Panel Detectors and X-Ray Image Intensifiers A Comparison

Digital Radiology with Photon Counting Detectors

Xenon-Diamond 2.9/106 With beam splitter

(Refer Slide Time: 00:10)

AeroDR X60. Motorized X-ray System

FMT18 FLOOR MOUNTED SYSTEM

» There are many possible techniques for making good radiographs. » Following a defined procedure will simplify technique

PRODUCT CATALOGUE 20 17

Center for Nondestructive Evaluation 304 Wilhelm Hall Iowa State University Ames, Iowa 50010

Computed Radiography of Resistance Temperature Sensor for Indian PHWR

QUANTITATIVE COMPUTERIZED LAMINOGRAPHY. Suzanne Fox Buchele and Hunter Ellinger

New portable eddy current flaw detector and application examples

Module-4 Lecture-2 Perpendicularity measurement. (Refer Slide Time: 00:13)

Technology Offer. Summary. Details

X-RAY COMPUTED TOMOGRAPHY

ProX Intraoral X-ray. PLANMECA is proud to introduce a new intraoral X-ray unit to its comprehensive collection of imaging products- the ProX.

Film Replacement in Radiographic Weld Inspection The New ISO Standard

Reconstruction Filtering in Industrial gamma-ray CT Application

Next-generation Fast-Neutron/X-ray Scanner for Air Cargo Interrogation

Robotic X-ray inspection system

PRODUCT BROCHURE PROFILER R. Tactile sensor for roughness measurement on Leitz CMMs

Beam Analysis BeamWatch Non-contact, Focus Spot Size and Position monitor for high power YAG, Diode and Fiber lasers. Disruptive Technology

LMT F14. Cut in Three Dimensions. The Rowiak Laser Microtome: 3-D Cutting and Imaging

Dental Line. Digital Panoramic System. radiology ahead

ADVANCED MEDICAL SYSTEMS PTE LTD Singapore Malaysia India Australia

Advances in High Energy X-ray Digital Detector Arrays

High-Precision Internal Diameter Measurements Using Eddy Current Arrays

Procedures for Performing Cryoelectron Microscopy on the FEI Sphera Microscope

Chapter 7. Optical Measurement and Interferometry

Diamond X-ray Rocking Curve and Topograph Measurements at CHESS

Transcription:

A new generation of x-ray computed tomography devices for quality inspection and metrology inspection in the field of additive manufacturing and other sciences Philip Sperling Sales Science and New Materials, YXLON International GmbH, Essener Bogen 15, Hamburg, Germany. More info about this article: http://www.ndt.net/?id=22221 Abstract E-mail: philip.sperling@hbg.yxlon.com The new generation of computed tomography devices like the YXLON FF20 and FF35 achieve extremely precise X-ray inspection results in 2D and computed tomography (CT) for a wide range of applications while at the same time it offers user friendliness at highest level by a new intuitive touch interface control concept and further smart functionalities. Available in a single or dual tube configuration, it is perfect for very small to medium size parts inspection in the automotive, electronics, aerospace and material science industries and research. With this new generation of CT devices the operator will generate the best results to understand the smallest details in his test sample. Keywords: Radiographic testing (RT), Computed Tomography, Metrology, Additive Manufacturing 1. Introduction Computed tomography goes light years beyond regular 2-D X-ray technology to deliver accurate three-dimensional images of scanned objects, including their voids and areas of differing density. It has become one of the most important and powerful non-destructive testing (NDT) methods - an achievement resulting from the continuous improvement of CT scanning and reconstruction methods, the enabling of increased precision and resolution, the manufacturing of cheaper and more compact devices and finally innovative concepts allowing for highest user friendliness to simplify the execution of successful CT experiments with high quality results. Today s range of NDT applications is applied to nearly every industry, i.e. automotive, electronics, aerospace and material science. Here, CT is used for research and development, failure analysis, process and quality control, small series inspection, combined DR-CT inspection, defect and material analysis, assembly checks and, becoming more and more important, metrology, i.e. dimensional measurements. To comply with such a variety of demands, YXLON has developed the powerful FF35 CT with an optional dual-tube-configuration (nano-focus transmission tube and high power microfocus tube), which makes the FF35 CT extremely versatile. With a simple touch of a button, each tube can be adjusted independently. Intuitive system control is accomplished via two touchscreens displaying easy-to-understand graphics. Intelligent functionality supports the user: As an example, "IntelliGuard" avoids collision with X-ray tube and detector by automatically determining the outershape of the inspection item during a 360 rotation. CT trajectories such as HeliExtend (Helical CT scan and reconstruction method) provide consistently good image quality from top to bottom, and [ID206] 1

capture elongated specimen with a high magnification scan. A system health monitor provides information on various parameters. Additionally, one can access this health-state of the system and the progress of the CT (and reconstruction) from everywhere through remote monitoring software. 2. Experimental Method Experiments are performed by choosing one out of two different x-ray sources mounted side-by-side in the high precision laboratory CT system FF35. The nano-focus transmission x-ray tube with a maximum photon energy of 190 kv and a maximum output power of 15 W enables highest resolution by accessing sub-micron length scales. The more powerful directional x-ray source performs up to 225 kv and a maximum target power of 280 W. The FF35 CT is equipped with a 300 mm x 250 mm (w x h) flat panel detector with a pixel size of 139 µm and various scintillator materials. A granite base enables precise manipulation of the inspection part which can weight up to 30 kg. By using the horizontal scan field extension or the helical CT option for vertical scan field extension the maximum scan field can be 300 mm in diameter or 500 mm in height. The additional detector axis for movements along the beam direction (focus to detector distance (FDD)) allows for the optimal combination of magnification (up to factor 200 and more) and collected photons for highly resolved CT results with an optimal signal-to-noise ratio. Reconstruction of the CT volumes is carried out by a filtered back projection algorithm. Data quality can be improved by applying a numerous variety of correction filters for beam-hardening, ring-artefacts, noise, bad pixels, focal spot drift, and more. Figure 1: YXLON FF35 CT system. [ID206] 2

3. Challenges for Additive Manufacturing Different application examples from different industries will be presented during the presentation to show challenges, problems and typical defects for this production method. Figure 2: Flow measurement nozzle with internal defects. Figure 3: Air probe with internal defects (closed channels). Figure 4: Cranial implant with powder residue in the lattice structure. [ID206] 3

4. CT as a tool for process optimization During the presentation different examples how to use an industrial CT scanner like the YXLON FF35 as a tool for process optimization for the additive manufacturing production process will be shown. Figure 5: CT is not only a tool for quality assurance and metrology. With the right analysis it is able to optimize your design and printing process. 5. CT Metrology With the FF35 CT system we implemented several functions referring to the VDI/VDE 2630. Different functions will be presented like Air-Conditioning, the SD Measurement Report, the YXLON SD Measurement Gauge and the Health Monitor. Figure 1: Selected features of the FF35 Metrology CT system: SD Measurement Report and YXLON SD Measurement gauge. [ID206] 4

An example, a helicopter bell crank, will be presented to show the different types of measurements and analysis. Figure 1: Bell crank with different measurements. 6. Results With the results of representative applications from additive manufacturing it was demonstrated how the performance of a today s laboratory CT devices, such as the YXLON FF35 CT, can support the analysis and inspection tasks for quality assurance, metrology and process optimization for different industries. References [1] YXLON FF35, 12.10.2017, https://www.yxlon.com/products/x-ray-and-ct-inspectionsystems/yxlon-ff35-ct [ID206] 5